| 61 |
IS 6312 (1994) |
Polyethylene containers for the transport of materials - Specification (Second Revision) |
- |
-
|
- View breakup
Rs.9913/-
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
31 Dec, 2023 |
- Included w.e.f. 29.06.2017. |
| 62 |
IS 14182 (1994) |
Solvent cement for use with unplasticized polyvinyl chloride plastic pipe and fittings - Specifications |
- |
-
|
8600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 - Table 1 - v-a(Chemical Resistance - Change in mass, increase) |
- |
0 |
|
- |
| 4.1 - Table 1 - v-a(Chemical Resistance - Change in mass, Decrease) |
- |
0 |
|
- |
| 4.1 - Table 1 - v-b(Chemical Resistance - Change in flexural yield strength, Increase) |
- |
0 |
|
- |
| 4.1 - Table 1 - v-b(Chemical Resistance - Change in flexural yield strength, Decrease) |
- |
0 |
|
- |
| 4.2(Shall be thixotropic and consist substantially of solvents that will swell plastisized PVC polymers and stabilizers) |
- |
0 |
|
- |
| 4.3(Shall be capable of application by brush and shall contain no lumps or foreign matter or macroscopic undissolved particles that will adversely affect the ultimate joint strength or chemical resistance of the material ) |
- |
0 |
|
- |
| 4.4(Shall not show gelation and no evidence of stratification or separation that cannot be removed by stirring) |
- |
0 |
|
- |
| 4.5(When used under the conditions for which they are designed, non metallic materials in contact with or likely to come in contact with potable water shall not constitute a toxic hazard , shall not support microbial growth and shall not give rise to unpleasant taste or odour, cloudiness or discolouration of the water) |
- |
0 |
|
- |
| 4.6(Solvents systems consisting of blends of tetrahydrofuran and cyclohexanone have been found to be acceptable) |
- |
0 |
|
- |
| 4.7(Vinyl Chloride Polymer content - Annex A) |
- |
1100 |
|
- |
| 4.8(Dissolution - Capable of dissolving an additional unplastisized PVC granular, powder compound or resin) |
- |
400 |
|
- |
| 4.5(REQUIREMENTS) |
- |
300 |
|
VISUAL APPEARANCE |
| 4.9 and 6.1(Viscosity) |
- |
0 |
|
Test charges has already been taken in cl. no. 4.9 and 6.1. |
| 4.7 and 6.1(REQUIREMENTS - Vinyl Chloride Polymer Content) |
- |
0 |
|
Test charges has already been taken in cl. no. 4.7 |
| 4.9 and 6.1(Viscosity - Regular) |
- |
0 |
|
Test charges has already been taken in cl. no. 4.9 and 6.1. |
| 4.9 and 6.1(Viscosity - Medium) |
- |
0 |
|
Test charges has already been taken in cl. no. 4.9 and 6.1. |
| 4.9 and 6.1(Viscosity - Heavy ) |
- |
1100 |
|
- |
| 4.10 and 6.1(Lap Shear Strength - After 2 h curing time) |
- |
1100 |
|
- |
| 4.10 and 6.1(Lap Shear Strength - After 10 h curing time) |
- |
1100 |
|
- |
| 4.10 and 6.1(Lap Shear Strength - After 72 h curing time) |
- |
1600 |
|
- |
| 4.11 and 6.1(Hydrostatic Burst Strength - After 2 h curing time) |
- |
850 |
|
- |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 63 |
IS 14735 (1999) |
Unplasticized Polyvinyl Chloride (UPVC) Injection Moulded Fittings for Soil and Waste Discharge System for Inside and Outside Buildings Including Ventilation and Rain Water System - |
- |
-
|
10675 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 19(Marking) |
- |
0 |
|
Nil |
| 3(Type of Fitting) |
- |
0 |
|
Nil |
| 4(Size Designation) |
- |
0 |
|
Nil |
| 5(Colour of fittings) |
- |
300 |
|
Nil |
| 7.1,Table 1(Wall thickness) |
- |
500 |
|
Nil |
| 7.2 ,Table 2&3(Socket Dimensions) |
- |
0 |
|
Test Charges already taken in clause no. 7.1 |
| 7.3(Dimensions of waste trap(Nahani Trap) |
- |
0 |
|
Test Charges already taken in clause no. 7.1 |
| 8(Sealing Rings) |
- |
375 |
|
Nil |
| 10(Workmanship) |
- |
300 |
|
Nil |
| 11(Design requirements) |
- |
500 |
|
Nil |
| 11.1(Solvent cement type or Rubber ring type) |
- |
0 |
|
Test Charges already taken in clause no. 11 |
| 11.2(Socket and spigot configeration) |
- |
0 |
|
Test Charges already taken in clause no. 11 |
| 11.4,Table 5(Vent cowl) |
- |
0 |
|
Test Charges already taken in clause no. 11 |
| 11.5,Table 6(Pipe Clips) |
- |
0 |
|
Test Charges already taken in clause no. 11 |
| 12(Physical test requirements) |
- |
0 |
|
Nil |
| 12.1(Visual appearance) |
- |
300 |
|
Nil |
| 12.2(Stress relief test) |
- |
700 |
|
Nil |
| 12.3(Vicat softening tempewrature) |
- |
1100 |
|
Nil |
| Cl.13, IS 12235 (P-7)-2004, (Resistance to Sulphuric Acid) |
- |
2500 |
|
Test charge Rs. 2000/- plus specimen charge Rs.500/- = 2500/- (25 % discount is not applicable in specimen charge) |
| Cl.14, Annex A(Titanium Di-Oxide Content) |
- |
1200 |
|
Nil |
| Cl.15, Annex B(Sulphated Ash Content) |
- |
950 |
|
Nil |
| 16(Mechanical Properties) |
- |
0 |
|
Nil |
| 16.1(Impact test) |
- |
1100 |
|
Nil |
| 17(Watet tightness of joint) |
- |
850 |
|
Nil |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 64 |
IS 14333 (1996) |
High Density Polyethylene Pipe For Sewerage - |
- |
-
|
11475 View breakup
Rs.8681/-,
Rs.3044/- Raw material
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10(Marking) |
- |
0 |
|
Nil |
| 3(Designation) |
- |
0 |
|
Nil |
| 4(Colour) |
- |
300 |
|
Nil |
| 6(Dimensions of pipes) |
- |
250 |
|
Nil |
| 7(Visual Appearance) |
- |
300 |
|
Nil |
| 8.1(Hydraulic characteristics) |
- |
6400 |
|
Type test for 168 hrs = Rs. 4800/- and Acceptance test for 48 hrs = Rs. 1600/- |
| 8.2(Reversion) |
- |
1000 |
|
Test charges Rs. 700 plus specimen charges Rs.300/- (25 % discount is not applicable in specimen charges) |
| 8.3(Density) |
- |
500 |
|
Nil |
| 8.4(Melt Flow Rate) |
- |
1100 |
|
Nil |
| Cl. 8.5, IS 2530-1963, Cl. 10(Cabon Black Content) |
- |
925 |
|
Nil |
| Cl. 8.5, IS 2530-1963, Cl. 16(Carbon Black Dispersion) |
- |
700 |
|
Nil |
|
Complete
|
|
31 Dec, 2023 |
- Upto 600 mm DN and excluding Chemical resistance classification (Annexure-D) |
| 65 |
IS 14252 (2015) |
Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sack for filling sand – Specification (second revision) |
- |
-
|
19140 View breakup
Rs.16903/-
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Raw Material) |
- |
1050 |
|
Nil |
| 3.2(Tapes – Width
) |
- |
250 |
|
Nil |
| 3.2(Tapes – Linear Density
) |
- |
250 |
|
Nil |
| 3.3(Tying Cord) |
- |
0 |
|
Charges already taken |
| 3.3(Tying Cord) |
- |
0 |
|
Charges already taken |
| 3.3(Tying Cord) |
- |
0 |
|
Charges already taken |
| 3.4(Sack) |
- |
0 |
|
Charges already taken |
| 3.4.1(Seam) |
- |
0 |
|
Charges already taken |
| 3.4.1(Seam) |
- |
0 |
|
Charges already taken |
| 3.4.1(Seam) |
- |
0 |
|
Charges already taken |
| 3.4.1(Seam) |
- |
0 |
|
Charges already taken |
| 4.1 and Table 1 i a(Dimensions Outside Length) |
- |
250 |
|
Nil |
| 4.1 and Table 1 i b(Dimensions Outside Width) |
- |
0 |
|
Charges already taken in clause no. 4.1 and Table 1 i a |
| 4.1 and Table 1 ii(Ends per dm ) |
- |
250 |
|
Nil |
| 4.1 and Table 1 iii(Picks per dm ) |
- |
250 |
|
Nil |
| 4.2 and Table 1 iv(Mass of sack
) |
- |
300 |
|
Nil |
| 4.1 and Table 1 v a(Average breaking strength of fabric Warpway
) |
- |
1100 |
|
Nil |
| 4.1 and Table 1 v b(Average breaking strength of fabric Weftway
) |
- |
1100 |
|
Nil |
| 4.1 and Table 1 vi(Average Breaking strength of bottom seam ) |
- |
1100 |
|
Nil |
| 4.1 and Table 1 vii a(Elongation at break of fabric Lengthwise) |
- |
1100 |
|
Nil |
| 4.1 and Table 1 vii b(Elongation at break of fabric Widthwise ) |
- |
1100 |
|
Nil |
| 4.1 and Table 1 viii(Average breaking strength and elongation at break of UV stabilized HDPE/PP fabric after been exposed to UV radiation and weathering ) |
- |
10340 |
|
25% discount is not applicable in conditioning charges |
| 4.1 and Table 1 ix(Ash content ) |
- |
950 |
|
Nil |
|
Complete
|
|
31 Dec, 2023 |
- Included w.e.f. 29.06.2017. |
| 66 |
IS 14151 : Part 1 (1999) |
Irrigation equipment - Sprinkler pipes - Specification: Part 1 polyethylene pipes (First Revision) |
- |
-
|
23025.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.3(CLASSIFICATION OF PIPES) |
- |
0 |
|
Nil |
| 4.1(melt flow rating (MFR) shall not exceed 1.10 g/10 min.) |
- |
1100.00 |
|
Nil |
| 4.1.1(density shall be between 940.4 kg/m’ and 958.4 kg/m3 (both inclusive) when determined at 27°C according to procedure prescribed in Annex A of IS 7328. The value of the density shall also not differ from the nominal value by more than 3 kg/m2 as per 5.2.1.1 of IS 7328.) |
- |
1125.00 |
|
Test charges Rs. 500.00 plus specimen charges Rs. 625.00 |
| 4.1.2(The MFR of the material shall be between 0.2 to 1.1 (both inclusive) when tested at 190 T at a nominal load of 50 N by the method prescribed in 7 of IS 2530. The MFR of the material shall also be within 20% of the value declared by the manufacturer.’) |
- |
1100.00 |
|
Nil |
| Cl. 4.2 , IS 2530-1963, Cl. 10(Cabon Black Content) |
- |
925.00 |
|
Nil |
| 4.3(Anti-oxidant) |
- |
0 |
|
Test facility is not available |
| 5.1 table -1(DIMENSIONS OF PIPES) |
- |
500.00 |
|
Nil |
| 5.1.2(Ovality) |
- |
0 |
|
Charges already taken in clause no. 5.1 TABLE-1 DIMENSIONS OF PIPES |
| 6.1(VISUAL APPEARANCE) |
- |
300.00 |
|
Nil |
| 7.1 Table -2(Hydraulic Characteristics) |
- |
0 |
|
Charges is taken in clause no. 7.1 |
| 7.2(Reversion Test) |
- |
1000 |
|
Test charges Rs. 700.00 + specimen charges Rs. 300.00 |
| 7.3(Tensile Test) |
- |
1350.00 |
|
Test charges Rs. 1100.00 + specimen charges Rs. 250.00 |
| 7.4table-2(Fusion Compatibility Test) |
- |
0 |
|
Charges is taken in clause no. 7.4 a) Quality test, b) Acceptance test |
| 7.5(Density) |
- |
1125.00 |
|
Nil |
| 7.6(Melt now Rate (MFR)) |
- |
1100.00 |
|
Nil |
| (Cl.4.2)(Carbon black- b) Dispersion of carbon black) |
- |
700.00 |
|
NIL |
| Cl.5(Dimensions of pipe - i) Outside diameter) |
- |
0 |
|
Charges already taken in clause no. 5.1 TABLE-1 DIMENSIONS OF PIPES |
| Cl.5(Dimensions of pipe - ii) Wall thickness minimum) |
- |
0 |
|
Charges already taken in clause no. 5.1 TABLE-1 DIMENSIONS OF PIPES |
| Cl.5(Dimensions of pipe - ii) Wall thickness maximum) |
- |
0 |
|
Charges already taken in clause no. 5.1 TABLE-1 DIMENSIONS OF PIPES |
| Cl 7.1(Hydraulic Characteristics - Acceptance test) |
- |
1600.00 |
|
- |
| Cl 7.1(Hydraulic Characteristics - Quality test) |
- |
4800.00 |
|
- |
| Cl.7.2)(Reversion Test) |
- |
0 |
|
Charges already taken in clause no. 7.2 |
| Cl.7.3(Tensile Test- i) Tensile Strength) |
- |
0 |
|
Charges is already taken in clause no. 7.3 |
| Cl.7.3(Tensile Test - ii)Elongation at Break) |
- |
0 |
|
Charges is already taken in clause no. 7.3 |
| Cl.7.4(Fusion Compatibility Test- a) Quality test) |
- |
1600.00 |
|
- |
| Cl.7.4(Fusion Compatibility Test- b) Acceptance test) |
- |
4800.00 |
|
- |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 67 |
IS 13592 (2013) |
Unplasticized Polyvinyl Chloride (PVC-U) Pipes for Soil and Waste Discharge System Inside and Outside Buiildings Including Ventilation and Rainwater System |
- |
-
|
17800 View breakup
Type-A: Rs.12400/-, Rs.825/- for PVC Resin, Rs.21800/- for Alternate (Optional);
Type-B: Rs.12725/-, Rs.825/- for PVC Resin, Rs.21800/- for alternate
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.5(Surface colour of the pipes shall be dark shade of grey) |
- |
300 |
|
Nil |
| Cl6.3(The composition shall be based on PVC resin
having a K-value of 64 or greater when tested in
accordance with IS 4669) |
- |
1100 |
|
Nil |
| Cl.7.1(Mean outside diameter, outside diameter at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
500 |
|
Nil |
| Cl.7.1( outside diameter at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
0 |
|
Charges already taken in clause no. 7.1 |
| Cl.7.1( wall thickness at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
0 |
|
Charges already taken in clause no. 7.1 |
| Cl.7.2(Pipes shall be supplied in nominal lengths of 2, 3, 4 or
6 metres either plain or with socket for solvent
cementing/grooved socket. Tolerances on specified
length shall be + 10 mm and – 0 mm.The nominal length of the pipe with socket for solvent
cementing/grooved socket shall be as given in Fig. 1.) |
- |
0 |
|
Charges already taken in clause no. 7.1 |
| Cl.7.3.1(Minimum wall thickness of socket on pipes shall
be as given in Table 2 read with Fig. 2 and Fig. 3.) |
- |
0 |
|
Charges already taken in clause no. 7.1 |
| Cl.7.3.2(Dimensions of sockets for solvent cementing and
grooved sockets of pipes shall be as given in Tables 3
and 4 respectively, read with Fig. 2 and 3.) |
- |
0 |
|
Charges already taken in clause no. 7.1 |
| Cl.8.1(The internal and external surface of the pipes shall be
smooth and clean, and free from grooving and other
defects. The end shall be clearly cut and shall be square
with the axis of the pipe. The end may be chamfered
on the plain side.) |
- |
300 |
|
Nil |
| Cl.8.2(When tested by the method described in IS 12235
(Part 5), a length of pipe sample of 200 ± 20 mm shall
not alter in length by more than 5 percent. In the case
of socket ended pipes, this test shall be carried out on
the plain portion of pipe taken at least 100 mm away
from the root of the socket.) |
- |
1000 |
|
Test charges Rs. 700/- plus specimen charges Rs. 300/- (25% discount is not applicable in specimen charges) |
| Cl8.3(This test shall be carried out for socket end pipes only.
When tested by the method described in IS 12235
(Part 6), the test specimens shall not show blisters,
excessive delamination or cracking or signs of weld
line splitting.) |
- |
700 |
|
Nil |
| Cl.8.4(When determined in accordance with IS 12235 (Part 2),
the vicat softening temperature of the specimen shall
not be less than 79°C.) |
- |
1100 |
|
Nil |
| Cl.8.5(After the required
period of exposure, the tensile strengths of two samples when tested as per IS 12235 (Part 13) shall not show
difference of more than 20 percent of their initial tensile
strengths) |
- |
3500 |
|
Nil |
| Cl. 9, IS 12235 Part 7(Resistance to Sulphuric Acid) |
- |
2500 |
|
Test charges Rs. 2000/- plus specimen charges Rs. 500/- (25% discount is not applicable in specimen charges) |
| Cl.10.1(When tested by method prescribed in IS 12235 (Part 9),the pipe shall have a true impact rate of not more than
10 percent. Mass of striker and height of fall shall be
as per Annex A.) |
- |
1400 |
|
Test charges Rs. 1100/- plus specimen charges Rs. 300/- (25% discount is not applicable in specimen charges) |
| Cl.10.2(When determined in accordance with the method
described in IS 12235 (Part 13), the tensile strength at
break shall not be less than 45 MPa.) |
- |
2700 |
|
Test charges Rs. 2200/- plus specimen charges Rs. 500/- (25% discount is not applicable in specimen charges) |
| Cl.10.3(The axial shrinkage shall not exceed 2 percent when
determined in accordance with Annex B.) |
- |
700 |
|
Nil |
| Cl.11.(Jointing of solvent
cementing joints is to be carried out using solvent
conforming to IS 14182.
Apply a pressure of 0.05 MPa for a period of 15 min
and there should be no leakage at any joint.) |
- |
1000 |
|
Nil |
| Cl. 12, IS 12235 Part 11(Resistance to Di-Chloro-Methane ) |
- |
1000 |
|
Nil |
|
Complete
|
|
31 Dec, 2023 |
- 0.0 |
| 68 |
IS 13488 (2008) |
Irrigation equipment - Emitting pipe systems - Specification (First Revision) |
- |
-
|
13900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.2 (Ref. Cl 4.1.c.i of IS 12786 : 1989)(Density) |
- |
1125 |
|
Test charges Rs.500/- plus specimen charges Rs. 625/- (25% discount is not applicable in specimen charges) |
| 5.1.2 (Ref. Cl 4.1.c.iii of IS 12786 : 1989)(Volatile matter - Annex B of IS 12786:1989) |
- |
700 |
|
Nil |
| 5.1.2 (Ref. Cl 4.1.c & 4.2.a of IS 12786 : 1989)(Carbon Black content - IS 2530 : 1963) |
- |
925 |
|
Nil |
| 5.1.2 (Ref. Cl 4.2.b of IS 12786 : 1989)(The dispersion of Carbon Black content shall be satisfactory - IS 2530 : 1963) |
- |
700 |
|
Nil |
| 6.2.2(Fittings) |
- |
0 |
|
Nil |
| 6.3(General) |
- |
300 |
|
Nil |
| 6.3(General) |
- |
0 |
|
Charges already taken in clause no. 6.3 |
| 8.1.2(Uniformity of Emission Rate for Unregulated Emitting Pipes) |
- |
1000 |
|
Nil |
| 8.1.3(Uniformity of Emission Rate for Regulated Emitting Pipes) |
- |
0 |
|
Charges already taken in clause no. 8.1.2 |
| 8.2(Emission Rate of Emitting Unit as a Function of Inlet Pressure) |
- |
1000 |
|
Nil |
| 8.2.1(Unregu/Qt~d Emining Pipe) |
- |
0 |
|
Charges already taken in clause no. 8.2 |
| 8.2.2(Regulated Emitting Pipes) |
- |
0 |
|
Charges already taken in clause no. 8.2 |
| 8.3.1(Wall Thickness ofEmitting Pipe) |
- |
400 |
|
Nil |
| 8.3.2(Inside Diameter ofEmitting Pipe) |
- |
0 |
|
Charges already taken in clause no. 8.3.1 |
| 8.3.3(Flow Paths in Emitting Unit) |
- |
0 |
|
Charges already taken in clause no. 8.3.1 |
| 8.3.4(Spacing ofEmitter Units) |
- |
0 |
|
Charges already taken in clause no. 8.3.1 |
| 8.4.1(Resistance to Hydrostatic Pressure at Ambient Temperature) |
- |
1000 |
|
Nil |
| 8.4.2(Resistance to Hydrostatic Pressure at Elevated Temperature) |
- |
160 |
|
Nil |
| 8.5(Resistance to Tension at Elevated Temperature) |
- |
1100 |
|
Nil |
| 8.5(Resistance to Tension at Elevated Temperature) |
- |
0 |
|
Charges already taken in clause no. 8.5 |
| 8.5(Resistance to Tension at Elevated Temperature) |
- |
0 |
|
Charges already taken in clause no. 8.5 |
| 8.6(Resistance to Pull Out of Joints Between Fitting and Emitting
IS 13479) |
- |
400 |
|
Nil |
| 8.7.1(Resistance of PE Emitting Pipe to
Environmental Stress Cracking -Acceptance Test
Annex D of IS 12786) |
- |
1200 |
|
Nil |
| 8.7.2(Resistance of PE Emitting Pipe to
Environmental Stress Cracking - Type Test
Annex D of IS 12786) |
- |
1600 |
|
Nil |
| 8.8(Determination of Emitting Unit Exponent) |
- |
600 |
|
Nil |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 69 |
IS 13422 (1992) |
Disposable surgical rubber gloves specification |
- |
-
|
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.4(Sterility) |
- |
2000 |
|
Nil |
| 4(TYPES) |
- |
0 |
|
Nil |
| 5.2.1(General Characteristics and Dimensions) |
- |
250 |
|
Nil |
| 5.2.2 and Table 1
Fig. 1(Dimensions - Length) |
- |
250 |
|
Nil |
| 5.2.2 and Table 1
Fig. 1(Dimensions - Width) |
- |
250 |
|
Nil |
| 5.2.2 and Table 1
Fig. 1(Dimensions - Thickness of Finger) |
- |
250 |
|
Nil |
| 5.2.2 and Table 1
Fig. 1(Dimensions - Thickness of Palm) |
- |
0 |
|
Charges already taken in clause no. 5.2.2 |
| 5.2.2 and Table 1
Fig. 1(Dimensions - Thickness of Cuff) |
- |
0 |
|
Charges already taken in clause no. 5.2.2 |
| 5.3 and Table 2( Tensile Strength Before Ageing) |
- |
1350 |
|
Nil |
| 5.3 and Table 2( Elongation at Break Before Ageing) |
- |
0 |
|
Charges already taken in clause no. 5.3 |
| 5.3 and Table 2(Stress at 500% Elongation at Break Before Ageing) |
- |
5300 |
|
Test charges Rs. 1100/- plus conditioning charges Rs. 4200/- (25% discount is not applicable in conditioning charges) |
| 5.3 and Table 2( Tensile StrengthAfter Accelerated Ageing) |
- |
0 |
|
Charges already taken in clause no. 5.3 |
| 5.3 and Table 2( Elongation at Break After Accelerated Ageing) |
- |
0 |
|
Charges already taken in clause no. 5.3 |
| 5.5(Airtight Test) |
- |
1300 |
|
Test charges Rs. 1000/- plus specimen charges Rs. 300/- (25% discount is not applicable in conditioning charges) |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 70 |
IS 13487 (1992) |
Irrigation equipment - Emitters - Specification |
- |
-
|
4700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Construction and workmanship) |
- |
300 |
|
Nil |
| 7.2(Flow path in emitters) |
- |
300 |
|
Nil |
| 7.3.1(Resistance to Hydrostatic pressure) |
- |
1000 |
|
Nil |
| 7.3.2(Resistance to Hydrostatic pressure) |
- |
0 |
|
Charges already taken in clause no. 7.3.1 |
| 7.3.3(Resistance to Hydrostatic pressure) |
- |
0 |
|
Charges already taken in clause no. 7.3.1 |
| 7.4.1(Emitter Pull Out In-line emitters) |
- |
500 |
|
Nil |
| 7.4.2(Emitter Pull Out On-line emitters) |
- |
0 |
|
Charges already taken in clause no. 7.4.1 |
| 8.1.2(Uniformity of Emission Rate Unregulated emitters) |
- |
1000 |
|
Nil |
| 8.1.2(Uniformity of Emission Rate Unregulated emitters) |
- |
0 |
|
Charges already taken in clause no. 8.1.2 |
| 8.1.3(Uniformity of Emission Rate Regulated emitters) |
- |
0 |
|
Charges already taken in clause no. 8.1.2 |
| 8.1.3(Uniformity of Emission Rate Regulated emitters) |
- |
0 |
|
Charges already taken in clause no. 8.1.2 |
| 8.2.2(Emission rate as a function of inlet pressure Unregulated emitters) |
- |
1000 |
|
Nil |
| 8.2.3(Emission rate as a function of inlet pressure Regulated emitters) |
- |
0 |
|
Charges already taken in clause no. 8.2.2 |
| 8.3(Determination of Emitter Exponent) |
- |
600 |
|
Nil |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 71 |
IS 12818 (2010) |
Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) |
- |
-
|
14725 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(COLOUR) |
- |
250 |
|
Nil |
| 4.1.1 (Ref. 3.4.1. of IS 10151)(Composition - The monomer content (VCM content) in the
resin - Annex A ofIS 10151) |
- |
3000 |
|
Nil |
| 4.1.2 (Ref. Cl 5.1. of IS 4669)(Composition - Loss on heating ) |
- |
1100 |
|
Nil |
| 4.1.2 (Ref. Cl 11 of IS 4669)(Composition -Sulphated ash content ) |
- |
0 |
|
Nil |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Nominal Diameter) |
- |
1500 |
|
Nil |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Mean Outer Diameter of Pipe) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Outer Diameter at any point ) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Mean Outer Diameter over Connection) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Wall thickness) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.2 and Table 5, 6 & 7
Fig 1B(DIMENSIONS - Casing Pipes) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.2 and Table 5, 6 & 7
Fig 1B(Nominal Diameter) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.2 and Table 5, 6 & 7
Fig 1B(Mean Outer Diameter of Pipe, Min) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.2 and Table 5, 6 & 7
Fig 1B(Mean Outer Diameter of Pipe , Max) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.2 and Table 5, 6 & 7
Fig 1B(Outer Diameter at any point , Min) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.2 and Table 5, 6 & 7
Fig 1B(Outer Diameter at any point, Max) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.2 and Table 5, 6 & 7
Fig 1B(Mean Outer Diameter over Connection) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.2 and Table 5, 6 & 7
Fig 1B(Wall thickness, Min) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.2 and Table 5, 6 & 7
Fig 1B(Wall thickness, Max) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.3.1(No.of Ribs) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.3.2(Rib height) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.4 Table 8 & 9
Fig 1(Effective length, l2) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.4 Table 8 & 9
Fig 1(Segmental length, l3) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.4 Table 8 & 9
Fig 1(Segmental length, l4) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.4 Table 8 & 9
Fig 1(Segmental length, l5) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.5 and Table 10
Fig 2A & 2B(Summation of slot lengths over internal circumference of the cross- section.) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.5 and Table 10
Fig 2A & 2B(Minimum number of slots on the circumference of the cross-section.) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 7.5 and Table 10
Fig 2A & 2B(Approximate Free Passage Area, in Percent (Mean Value) for Width of Slot (w)) |
- |
0 |
|
Charges already taken in clause no. 7.1 Table 1 |
| 8.4(Sealing rings - Hardness) |
- |
375 |
|
Nil |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
250 |
|
Nil |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
0 |
|
Charges already taken in clause no. 8.4.1 |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
0 |
|
Charges already taken in clause no. 8.4.1 |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
0 |
|
Charges already taken in clause no. 8.4.1 |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
0 |
|
Charges already taken in clause no. 8.4.1 |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
0 |
|
Charges already taken in clause no. 8.4.1 |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
0 |
|
Charges already taken in clause no. 8.4.1 |
| 9.1(Visual Appearance) |
- |
300 |
|
Nil |
| 9.1( Visual Appearance) |
- |
0 |
|
Charges already taken in clause no. 9.1 |
| 9.2(Internal Diameter) |
- |
350 |
|
Nil |
| 9.3(Density
IS 12235 (Part 14)) |
- |
500 |
|
Nil |
| 9.4 and Table 14(Resistance to External Blows at 0 ?C
IS 12235 (Part 9)) |
- |
1400 |
|
Test charges Rs. 1100/- plus specimen charges Rs. 300/- (25% discount is not applicable in specimen charges) |
| 9.5(Tensile Strength
IS 12235(Part 13)) |
- |
1600 |
|
Test charges Rs. 1100/- plus specimen charges Rs. 500/- (25% discount is not applicable in specimen charges) |
| 9.6(Vicat Softening Temperature
IS 12235 (Part 2).) |
- |
1100 |
|
Nil |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 72 |
IS 12786 (1989) |
Irrigation equipment - Polyethylene pipes for irrigation laterals - Specification |
- |
-
|
9725.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.c.i (Density) |
- |
0 |
|
- |
| 4.1.c.iii (Volatile matter - Annex B ) |
- |
0 |
|
- |
| 4.1.c & 4.2.a (Carbon Black content - IS 2530 : 1963) |
- |
925 |
|
Nil |
| 4.2.b (The dispersion of Carbon Black content shall be satisfactory - IS 2530 : 1963) |
- |
700 |
|
Nil |
| 7.3(Tensile Test) |
- |
1350 |
|
Test Charges Rs. 1100/- + Specimen charges Rs. 250/- |
| 7.3(Elongation at Break) |
- |
0 |
|
Charges already taken in tensile test (Clause no. 7.3) |
| 7.4(SusceptibiIity to Environmental Stress
Cracking) |
- |
1200 |
|
Nil |
| 5 and Table 1(DIMENSIONS OF PIPES - outside diameters) |
- |
250 |
|
- |
| 5 and Table 1(DIMENSIONS OF PIPES - wall thickness shall) |
- |
0 |
|
Charges already taken in clause 5 and table 1 (DIMENSIONS OF PIPES - outside diameters) |
| 6.1(Visual Appearance) |
- |
300 |
|
- |
| 7.1(Hydraulic Characteristics) |
- |
3000 |
|
Quality test |
| 7.1(Hydraulic Characteristics) |
- |
1000 |
|
acceptance test |
| 7.2(Reversion Test) |
- |
1000 |
|
Testing charge 700.00+ specimen charge 300.00 |
| 5 and Table 1(DIMENSIONS OF PIPES - wall thickness shall) |
- |
0 |
|
- |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 73 |
IS 12785 (1994) |
Irrigation equipment - Strainer - Type filters - Specification (first revision) |
- |
-
|
11250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1(Zinc Coating - IS 4736) |
- |
0 |
|
Nil |
| 4.1.1(General) |
- |
500 |
|
Nil |
| 4.1.1(General) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.1(General) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.1(General) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.1(General) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.1(General - The hot dip galvanizing shall be done in accordance with IS 4736 with a minimum zinc coating) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.1(General - Thickness of powder coating
IS 5116.) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.2(General) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.2(General) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.3(General) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.4(General) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.2.1(Strainer Housing) |
- |
500 |
|
Nil |
| 4.2.2(Strainer Housing) |
- |
0 |
|
Charges already taken in clause no. 4.2.1 |
| 4.2.3(Strainer Housing) |
- |
0 |
|
Charges already taken in clause no. 4.2.1 |
| 4.3.1(Connections
IS 2643 : 1975.) |
- |
500 |
|
Nil |
| 4.3.2(Connections
IS 6418 : 1971) |
- |
0 |
|
Charges already taken in clause no. 4.3.1 |
| 4.3.3(Connections) |
- |
0 |
|
Charges already taken in clause no. 4.2.1 |
| 4.3.4(Connections) |
- |
0 |
|
Charges already taken in clause no. 4.2.1 |
| 6.1(MECHANiCAL TESTS) |
- |
1500 |
|
Nil |
| 6.1(MECHANiCAL TESTS) |
- |
0 |
|
Charges already taken in clause no. 6.1 |
| 6.2(MECHANiCAL TESTS ) |
- |
3750 |
|
Nil |
| 6.3(MECHANiCAL TESTS ) |
- |
1000 |
|
Nil |
| 6.4(MECHANiCAL TESTS ) |
- |
1000 |
|
nIL |
| 6.5(MECHANiCAL TESTS ) |
- |
2500 |
|
Nil |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 74 |
IS 12701 (1996) |
Rotational moulded polyethylene water storage tanks - specification (First Revision) |
- |
-
|
17150.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2.3(Carbon Black Content ) |
- |
925 |
|
Nil |
| 4.2.3(Carbon Dispersion Test) |
- |
700 |
|
Nil |
| 5(Types and Features ) |
- |
0 |
|
Nil |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
3050 |
|
Nil |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.3(Types and Features ) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.6(Types and Features ) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 6.1(Finish) |
- |
300 |
|
Nil |
| 7.1.1(Resistance to Deformation) |
- |
700 |
|
Nil |
| 7.1.2(Resistance to Deformation) |
- |
0 |
|
Charges already taken in clause no. 7.1.1 |
| 7.2(Resistance to Impact) |
- |
1100 |
|
Nil |
| 7.3(Test for Top Load Resistance) |
- |
900 |
|
Nil |
| 7.4(Tensile Strength) |
- |
1350 |
|
Testing charges Rs.1100/- + specimen charges Rs.250/- |
| 7.5(Flexural Modulus) |
- |
1600 |
|
Testing charges Rs.1100/- plus specimen charges Rs.500/- (25% discount is not applicable in specimen charges) |
| 7.6(overall Migration) |
- |
2200 |
|
Testing charges Rs.1700/- + specimen charges Rs.500/- |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 75 |
IS 12585 (1988) |
Specification for thermoplastic hoses (Textile Reinforced) for water - General purpose |
- |
-
|
6500 View breakup
Rs.4875/-
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 3(Types) |
- |
0 |
|
Nil |
| Cl 4.1(Construction) |
- |
300 |
|
Nil |
| Cl 4.2(Dimensions & Tolerances) |
- |
500 |
|
Nil |
| Cl 4.3.1 & Appendix A(Loss in Mass on Heating) |
- |
700 |
|
Nil |
| Cl 4.3.2(Adhesion) |
- |
1100 |
|
Nil |
| Cl 4.3.3(Pressure Requirements) |
- |
1700 |
|
Nil |
| Cl 4.3.4(Minimum Bend Radius) |
- |
700 |
|
Nil |
| Cl 4.3.5(Low Temperature Flexibility) |
- |
1500 |
|
Nil |
|
Complete
|
|
31 Dec, 2023 |
- 0.0 |
| 76 |
IS 12232 : Part 1 (1996) |
Irrigation equipment - Rotating sprinkler: Part 1 design and operational requirements (First Revision) |
- |
-
|
21200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Materials) |
- |
1350 |
|
Nil |
| 4.1(Materials) |
- |
0 |
|
Charges already taken in clause no. 4.1 |
| 4.1(Materials) |
- |
0 |
|
Charges already taken in clause no. 4.1 |
| 4.2.1(Construction and workmanship) |
- |
300 |
|
Nil |
| 4.2.2(Construction and workmanship) |
- |
0 |
|
Charges already taken in clause no. 4.2.1 |
| 4.2.3(Construction and workmanship) |
- |
0 |
|
Charges already taken in clause no. 4.2.1 |
| 4.3(Threaded connections
ISO 7-1.) |
- |
400 |
|
Nil |
| 4.4.1(Effective pressures) |
- |
400 |
|
Nil |
| 4.4.2(Actuating mechanism) |
- |
400 |
|
Nil |
| 6.1(Test of construction and parts) |
- |
300 |
|
Nil |
| 6.2.1(Threaded connections to riser) |
- |
400 |
|
Nil |
| 6.2.2(Nozzle threads intended for threaded
connection) |
- |
400 |
|
Nil |
| 6.3(Test of resistance to hydrostatic pressure at ambient temperature) |
- |
850 |
|
Nil |
| 6.4(Test of resistance to hydrostatic
pressure at high temperature) |
- |
1600 |
|
Nil |
| 6.5.1 a(Watertightness of sprinkler - flowrate < 250 Iih) |
- |
400 |
|
Nil |
| 6.5.2(Watertightness of nozzle connection) |
- |
400 |
|
Nil |
| 7.1(Test of uniformity of rotation speed) |
- |
400 |
|
Nil |
| 7.2(Test of uniformity of ftowrate ) |
- |
400 |
|
Nil |
| 7.3(Test of distribution characteristics) |
- |
1900 |
|
Nil |
| 7.4(Test of effective diameter of coverage) |
- |
400 |
|
Nil |
| 7.5(Test of trajectory height (for sprinklers
with low trajectory angle)) |
- |
400 |
|
Nil |
| 7.6(Test of range of effective pressure) |
- |
400 |
|
Nil |
| 8.1 and 6.1(Durability tests) |
- |
6550 |
|
Nil |
| 8.2 and 6.3(Durability tests) |
- |
850 |
|
Nil |
| 8.3 and 6.5.1(Durability tests) |
- |
400 |
|
Nil |
| 8.4(Durability tests) |
- |
400 |
|
Nil |
| 8.5(Durability tests) |
- |
400 |
|
Nil |
| 8.6(Durability tests) |
- |
1500 |
|
Nil |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 77 |
IS 15351 (2015) |
Agro textiles – Laminated high density polyethylene (HDPE) woven geomembrane for water proof lining – Specification (second revision) |
- |
-
|
196400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(HDPE Tapes) |
- |
2050 |
|
Nil |
| 3.2(HDPE Fabric) |
- |
1975 |
|
Nil |
| 5(MANUFACTURE) |
- |
300 |
|
Nil |
| 5.1(Lamination) |
- |
1050 |
|
Nil |
| 5.2(Panel Width) |
- |
250 |
|
Nil |
| 5.3(Joints/Seams) |
- |
200 |
|
Nil |
| 5.1.1 and 6.2(Thickness, mm- IS 7016: Part 1) |
- |
250 |
|
Nil |
| 5.1.1 and 6.2(Mass, g/sq m) |
- |
250 |
|
Nil |
| 5.1.1 and 6.2(Dimensions, mm- Annexure A of IS 11652) |
- |
250 |
|
Nil |
| 5.1.1 and 6.2(Length) |
- |
0 |
|
Charges already taken in dimension |
| 5.1.1 and 6.2(Width) |
- |
0 |
|
Charges already taken in dimension |
| 5.1.1 and 6.2(Carbon black content, Percent- IS 2530) |
- |
925 |
|
Nil |
| 5.1.1 and 6.2(Breaking Load on 20 cm X 10 cm Strip, Min ) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2(Before UV exposure IS 13162 (Part 5) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2(Strain at Maximum load, Percent-IS 13162 (Part 5) |
- |
1100 |
|
Nil |
| Table-1(Breaking load on 20 × 10 cm strip, N, Min after) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2( U.V exposure of 1000 h for warp and weft) |
- |
176000 |
|
Rs. 176000/- conditioning charges (25% discount is not applicable in conditioning charges) |
| 5.1.1 and 6.2(Impact failure load, at 1524 mm drop,) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2( Min, gram force at 50 percent failure-Annex C) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2(Tear resistance, N, Min-Method A1 of
IS 7016 (Part 3)) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2(Puncture resistance, N, Min-Annex D) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2(Bursting strength (Ball burst),N/cm², Min-) |
- |
1000 |
|
Nil |
| 5.1.1 and 6.2(IS 7016 (Part 6)) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2(Seam strength before UV exposure (N/mm), Min-IS 15060) |
- |
1100 |
|
Nil |
| Table-1(Seam strength after UV exposure N/mm, Min-Annex B and
IS 15060) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2(Hydrostatic resistance-Annex E) |
- |
2000 |
|
Nil |
| 5.1.1 and 6.2(Ash content, percent, Max-Annex F) |
- |
950 |
|
Nil |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 78 |
IS 16208 (2015) |
Textiles - High density polyethylene (HDPE)/polypropylene (PP) woven sacks for packaging 10 kg, 15 kg, 20 kg, 25 kg and 30 kg foodgrains - Specification |
- |
-
|
20580 View breakup
Rs.17155/-
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(TYPES) |
- |
300 |
|
Nil |
| 4.1(Raw Material) |
- |
1050 |
|
Nil |
| 4.2(Tapes – Width
IS 6192 and IS 11197) |
- |
250 |
|
Nil |
| 4.2(Tapes – Linear Density
) |
- |
500 |
|
Nil |
| 4.2(Construction) |
- |
250 |
|
Nil |
| 4.3(Sacks) |
- |
300 |
|
Nil |
| 4.3.1(Bottom Seam) |
- |
0 |
|
Charges already taken in clause no. 4.3 |
| 4.3.1( The two rows of stitches shall be separated from each other) |
- |
0 |
|
Charges already taken in clause no. 4.3 |
| 4.3.1( The outer stitch) |
- |
0 |
|
Charges already taken in clause no. 4.3 |
| 4.3.1( The stitching shall be done with double fold over seam to a depth ) |
- |
0 |
|
Charges already taken in clause no. 4.3 |
| 4.3.1(Stitches pass through a minimum of six layers of the fabric. ) |
- |
0 |
|
Charges already taken in clause no. 4.3 |
| 4.3.1(The number of stitches/dm) |
- |
0 |
|
Charges already taken in clause no. 4.3 |
| 4.3.2(Mouth) |
- |
0 |
|
Charges already taken in clause no. 4.3 |
| 4.4 and Table 1 i(Capacity) |
- |
250 |
|
Nil |
| 5.2 and Table 1 ii a(Dimensions Inside Length) |
- |
250 |
|
Nil |
| 5.2 and Table 1 ii b(Dimensions Inside Width) |
- |
0 |
|
Charges already taken in clause no. 5.2 |
| 5.2 and Table 1 iii(Ends per dm ) |
- |
250 |
|
Nil |
| 5.2 and Table 1 iv(Picks per dm ) |
- |
250 |
|
Nil |
| 5.1 and Table 1 v(Mass of sack ) |
- |
300 |
|
Nil |
| 5.2 and Table 1 vi a(Average breaking strength of fabric Lengthwise ) |
- |
1100 |
|
Nil |
| 5.2 and Table 1 vi b(Average breaking strength of fabric Widthwise ) |
- |
1100 |
|
Nil |
| 5.2 and Table 1 vi(Breaking strength of bottom seam ) |
- |
1100 |
|
Nil |
| 5.2 and Table 1 viii a(Elongation at break of fabric Lengthwise) |
- |
1100 |
|
Nil |
| 5.2 and Table 1 viii b(Elongation at break of fabric Widthwise ) |
- |
1100 |
|
Nil |
| 5.2 and Table 1 ix(Average breaking strength and elongation at break of UV stabilized HDPE/PP fabric after been exposed to UV radiation and weathering ) |
- |
10180 |
|
Rs. 10180/- Conditioning charges (25% discount is not applicable) |
| 5.2 and Table 1 x(Ash content ) |
- |
950 |
|
Nil |
|
Complete
|
|
31 Dec, 2023 |
- Included w.e.f. 29.06.2017. |
| 79 |
IS 9537 : Part 4 (1983) |
Specification for conduits for electrical installations: Part 4 pliable self - Recovering conduits of insulating materials |
- |
-
|
9700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Marking, IS 9537-4) |
- |
300 |
|
Nil |
| 6.1(Marking, IS 9537-4) |
- |
0 |
|
Nil |
| 6.1(Marking, IS 9537-4) |
- |
0 |
|
Nil |
| 6.1(Marking, IS 9537-4) |
- |
0 |
|
Nil |
| 6.2(Marking, IS 9537-4) |
- |
0 |
|
Nil |
| 6.2.1(Marking, IS 9537-4) |
- |
0 |
|
Nil |
| 6.3(Marking, Cl. 6.4 of IS 9537-1) |
- |
0 |
|
Nil |
| 7.1(Dimensions, (Minimum outside Diameter), IS 9537-4) |
- |
1000 |
|
Nil |
| 7.1(Dimensions (Maximum outside Diameter), IS 9537-4) |
- |
0 |
|
Charges already taken in clause no. 7.1 |
| 7.3.3(Uniformity of wall thickness, IS 9537-4) |
- |
0 |
|
Charges already taken in clause no. 7.1 |
| 9.2(Mechanical Properties (Bending test), Cl. 9.3 of IS 9537-1) |
- |
500 |
|
Nil |
| 9.2(Mechanical Properties (Bending test), Cl. 9.3 of IS 9537-1) |
- |
500 |
|
Nil |
| 9.3(Mechanical Properties (Compression Test), IS 9537-4) |
- |
1100 |
|
Nil |
| 9.4(Mechanical Properties (Impact Test), Cl. 9.4 of IS 9537-1) |
- |
1100 |
|
Nil |
| 9.5(Mechanical Properties (Collapse Test), IS 9537-4) |
- |
1000 |
|
Nil |
| 10(Resistance to heat) |
- |
700 |
|
Nil |
| 11(Resistance to burning, Cl. 11 of IS 9537-1) |
- |
700 |
|
Nil |
| 12(Electrical Strength, Cl. 12.1.1 of IS 9537-1) |
- |
1400 |
|
Test charges Rs. 1100/- Plus specimen charges Rs. 300/- (25 % discount is not applicable in specimen charges) |
| 12(Insulation Resistance, Cl. 12.1.2 of IS 9537-1) |
- |
1400 |
|
Test charges Rs. 1100/- Plus specimen charges Rs. 300/- (25 % discount is not applicable in specimen charges) |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 80 |
IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
- |
-
|
9700 View breakup
Rs.7425/-
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Marking) |
- |
0 |
|
Nil |
| 6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
Nil |
| 6.3(Standard Mark on Conduit) |
- |
0 |
|
Nil |
| 7.1.1(Maximum and minimum outside diameter of socket) |
- |
1000 |
|
Nil |
| 7.1.1 Table-2(Length of Socket end) |
- |
0 |
|
Charges already taken in clause no. 7.1.1 |
| 7.1.2(Maximum and minimum outside diameter of conduit) |
- |
0 |
|
Charges already taken in clause no. 7.1.1 |
| 7.2(Minimum inside diameter of conduit) |
- |
0 |
|
Charges already taken in clause no. 7.1.1 |
| 7.3(Length of conduit) |
- |
0 |
|
Charges already taken in clause no. 7.1.1 |
| 7.4(Unifomity of The wall Thickness) |
- |
0 |
|
Charges already taken in clause no. 7.1.1 |
| 8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
300 |
|
Nil |
| 9.2(Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
1000 |
|
Nil |
| 9.3(Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
1100 |
|
Nil |
| 9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
1100 |
|
Nil |
| 9.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
1000 |
|
Nil |
| 10(Resistance to Heat -Ball presure test) |
- |
700 |
|
Nil |
| 11(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
700 |
|
Nil |
| 12(Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
1400 |
|
Test Charges Rs. 1100/- plus specimen charges Rs. 300/- (25% discount is not applicable in specimen charges) |
| 13(Tests for external influence as per clause 13 of IS: 9537 (Part 1)-1980) |
- |
1400 |
|
Test Charges Rs. 1100/- plus specimen charges Rs. 300/- (25% discount is not applicable in specimen charges) |
|
Complete
|
|
31 Dec, 2023 |
- 0.0 |
| 81 |
IS 9537 : Part 2 (1981) |
Specification for conduits for electrical installations: Part 2 rigid steel conduits |
- |
-
|
4500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Marking, IS 9537-2) |
- |
0 |
|
Nil |
| 6.1(Marking, IS 9537-2) |
- |
0 |
|
Nil |
| 6.1(Marking, IS 9537-2) |
- |
0 |
|
Nil |
| 6.3(Marking, Cl. 6.4 of IS 9537-1) |
- |
0 |
|
Nil |
| 6.2(Marking, IS 9537-2) |
- |
0 |
|
Nil |
| 7.2.1(Dimensions, (Minimum outside Diameter), IS 9537-2) |
- |
1000 |
|
Nil |
| 7.2.2(Dimensions (Maximum outside Diameter), IS 9537-2) |
- |
0 |
|
Charges already taken in clause no. 7.2.1 |
| 7.3(Dimensions (Wall thickness), IS 9537-2) |
- |
0 |
|
Charges already taken in clause no. 7.2.1 |
| 7.3.3(Uniformity of wall thickness, IS 9537-2) |
- |
0 |
|
Charges already taken in clause no. 7.2.1 |
| 8.1(Construction, Cl. 8 of IS 9537-1) |
- |
300 |
|
Nil |
| 8.2(Construction, IS 9537-2) |
- |
0 |
|
Charges already taken in clause no. 8.1 |
| 9.2(Mechanical Properties (Bending test), Cl. 9.3 of IS 9537-1) |
- |
1000 |
|
Nil |
| 9.3(Mechanical Properties (Compression Test), IS 9537-2) |
- |
1100 |
|
Nil |
| 13(External Influences, IS 9537-2) |
- |
1100 |
|
Nil |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 82 |
IS 8521 : Part 1 (1977) |
Specification for industrial safety face shields: Part 1 with plastics visor |
- |
-
|
9450 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 3(General requirements & Specific requirements) |
- |
250 |
|
Nil |
| Cl 4(Visual and Dimensional Examination & Physical Requirements (Impact Resistance, Penetration Resistance, Visible Transmittance, Flammability & Disinfection)) |
- |
9200 |
|
Testing charges Rs. 8950/- plus specimen charges 250/- (25 % discount is not applicable in specimen charges) |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 83 |
IS 4985 (2021) |
UNPLASTICIZED PVC PIPES FOR POTABLE WATER SUPPLIES SPECIFICATION Fourth Revision |
- |
-
|
31925 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(CLASSIFICATION OF PIPES) |
- |
300 |
|
Nil |
| 7(DIMENSIONS-PIPE-Nominal Diameter) |
- |
500 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Minimum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Mamimum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. Variation) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Maximum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.1.1.2(DIMENSIONS-PIPE-Ovality (Maximum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.1.2.1(DIMENSIONS-PIPE-Average Thickness) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.2.1(DIMENSIONS-Socket) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.2.1(DIMENSIONS-Socket) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Minimum Length) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Minimum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Maximum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.2.1.2(a)-Table 5(DIMENSIONS-Sockets for elastomeric sealing ring joints-Minimum depth of engagement) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.2.1.2-Table 4(DIMENSIONS-Sockets for elastomeric sealing ring joints-Socket inner Diameter) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 8(SEALING RINGS) |
- |
250 |
|
- |
| 9.1(PIPE ENDS) |
- |
250 |
|
- |
| 9.1(PIPE ENDS) |
- |
0 |
|
Charges already taken in clause no. 7 |
| 10.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
300 |
|
Nil |
| 10.1.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
0 |
|
Charges already had taken in clause no. 10.1 |
| 10.2(PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
575 |
|
Nil |
| 10.4(PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
900 |
|
Test Charges Rs. 700/- plus Rs. 250 specimen charges (25% discount is not applicable in specimen charges) |
| 10.5(PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
1100 |
|
Nil |
| 10.6(PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
500 |
|
Nil |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)) |
- |
11000 |
|
Nil |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
850 |
|
Nil |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)-for Integral Sealing Ring
Sockets) |
- |
5000 |
|
Nil |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Integral Sealing Ring
Sockets) |
- |
850 |
|
Nil |
| 11.1.1(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Plumbing pipes) |
- |
850 |
|
Nil |
| 11.2(Resistance to External Blows at 0°C) |
- |
1000 |
|
Nil |
| Clause 10.7(Sulphated Ash Content) |
- |
950 |
|
Nil |
| 10.1(Colour) |
- |
0 |
|
- |
| 10.1(Surface Finish) |
- |
250 |
|
nil |
| 7.2.1.1 Table3(Angle of taper (Note-1)) |
- |
0 |
|
- |
| 10.7(Sulphated Ash Content) |
- |
0 |
|
The charges had already taken in the No. Clause 10.7 |
| 5(CLASSIFICATION OF PIPES) |
- |
0 |
|
- |
| 7(DIMENSIONS-PIPE-Nominal Diameter) |
- |
0 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Minimum)) |
- |
0 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. Variation) |
- |
0 |
|
- |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
0 |
|
- |
| 7.1.1.2(DIMENSIONS-PIPE-Ovality (Maximum)) |
- |
0 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
0 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
0 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Average Thickness) |
- |
0 |
|
- |
| 7.2.1(DIMENSIONS-Socket) |
- |
0 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Minimum Length) |
- |
0 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Minimum)) |
- |
0 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Maximum)) |
- |
0 |
|
- |
| 7.2.1.2(a)-Table 5(DIMENSIONS-Sockets for elastomeric sealing ring joints-Minimum depth of engagement) |
- |
0 |
|
- |
| 7.2.1.2-Table 4(DIMENSIONS-Sockets for elastomeric sealing ring joints-Socket inner Diameter) |
- |
0 |
|
- |
| 8(SEALING RINGS) |
- |
0 |
|
The charges had taken already in clause no. 08. |
| 10.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
0 |
|
- |
| 10.2(PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
0 |
|
The charges had already taken in the clause no. 10.2 |
| 10.4(PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
0 |
|
The charges had already taken in the clause No. 10.4 |
| 10.5(PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
0 |
|
The charges had already taken in the clause No. 10.5 |
| 10.6(PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
0 |
|
The charges had already taken in the clause No. 10.6 |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)) |
- |
0 |
|
- |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
0 |
|
- |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)-for Integral Sealing Ring Sockets) |
- |
0 |
|
- |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Integral Sealing Ring Sockets) |
- |
0 |
|
- |
| 11.1.1(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Plumbing pipes) |
- |
0 |
|
- |
| 11.2(Resistance to External Blows at 0°C) |
- |
1300 |
|
- |
| 10.3(Effect on Water Test) |
- |
3000 |
|
- |
| 6.1.2(PVC Resin) |
- |
1100 |
|
- |
| 15.4 (b)(Cold impact) |
- |
1100 |
|
- |
| 9.1(PIPE ENDS) |
- |
0 |
|
- |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 84 |
IS 4148 (1989) |
Surgical rubber gloves - Specification (First Revision) |
- |
-
|
15400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1(Manufacture) |
- |
250 |
|
Nil |
| 4.1.2(Manufacture) |
- |
0 |
|
Charges already taken |
| 4.1.3(Manufacture) |
- |
0 |
|
Charges already taken |
| 4.1.4(Manufacture) |
- |
0 |
|
Charges already taken |
| 4.2(Dimensions Fig 1 and Table 1) |
- |
250 |
|
Nil |
| 4.2(Dimensions Fig 1 and Table 1) |
- |
0 |
|
Charges already taken |
| 4.2(Dimensions Fig 1 and Table 1) |
- |
0 |
|
Charges already taken |
| 4.2(Dimensions Fig 1 and Table 1) |
- |
0 |
|
Charges already taken |
| 4.2(Dimensions Fig 1 and Table 1) |
- |
0 |
|
Charges already taken |
| 4.2(Dimensions Fig 1 and Table 1) |
- |
0 |
|
Charges already taken |
| 4.2(Dimensions Fig 1 and Table 1) |
- |
0 |
|
Charges already taken |
| 4.3(Thickness) |
- |
250 |
|
Nil |
| 4.4.1(Physical Properties) |
- |
1350 |
|
Test charges Rs. 1100/- plus Rs. 250/ Specimen charges (25% discount is not applicable in specimen charges) |
| 4.4.1(Physical Properties) |
- |
1350 |
|
Test charges Rs. 1100/- plus Rs. 250/ Specimen charges (25% discount is not applicable in specimen charges) |
| 4.4.2(After accelerated aging at 70 + 1OC for 240 h ) |
- |
6000 |
|
(25% discount is not applicable in Ageing charges) |
| 4.4.2(After accelerated aging at 70 + 1OC for 240 h ) |
- |
0 |
|
Test charges already taken |
| 4.4.3(After heat ageing in autoclave) |
- |
2500 |
|
(25% discount is not applicable in Ageing charges) |
| 4.4.3(After heat ageing in autoclave) |
- |
0 |
|
Charges already taken |
| 4.4.4(Tension Set) |
- |
1350 |
|
Test charges Rs. 1100/- plus Rs. 250/ Specimen charges (25% discount is not applicable in specimen charges) |
| 4.5(pH of Aqueous Extract ) |
- |
750 |
|
Nil |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 85 |
IS 3462 (1986) |
Unbacked Flexible Pvc Flooring |
- |
-
|
19800 View breakup
Rs.17238/-
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1(DIMENSIONS AND TOLERANCES-Liaear Dimension-Sheets or Rolls) |
- |
200 |
|
Nil |
| 5.1.2(DIMENSIONS AND TOLERANCES-Liaear Dimension-Tiles) |
- |
250 |
|
Nil |
| 5.2(DIMENSIONS AND TOLERANCES-Thickness) |
- |
0 |
|
Charge already taken in clause no. 5.1.1 (Combined charges) |
| 6. 1(COLOUR AND SURFACE CHARACTERISTICS) |
- |
250 |
|
Nil |
| 7.1-Table 1(iii)(REQUlREMENTS-rile size
) |
- |
0 |
|
Charge already taken |
| 7.1-Table 1(iv)(REQUlREMENTS-Dimensional stability
) |
- |
700 |
|
Nil |
| 7.1-Table 1(iv)(REQUlREMENTS-Squareness
) |
- |
0 |
|
Charge already taken |
| 7.1-Table 1(v)(REQUlREMENTS-Colour fastness to daylight
) |
- |
850 |
|
Nil |
| 7.1-Table 1(vi)(REQUlREMENTS-Curling
) |
- |
0 |
|
Charge already taken |
| 7.1-Table 1(vii)(REQUlREMENTS-Residual indenration
) |
- |
1400 |
|
Nil |
| 7.1-Table 1(viii)(REQUlREMENTS-Flexibility
) |
- |
1500 |
|
Nil |
| 7.1-Table 1(ix)(REQUlREMENTS-Resistance to various substances-Scratch width
) |
- |
1100 |
|
nil |
| 7.1-Table 1(x)(REQUlREMENTS-Resistance to various substances
) |
- |
0 |
|
Charge already taken in clause no. 7.1 (Combined charges) |
| 7.1-Table 1(xi)(REQUlREMENTS-Ply adhesion
) |
- |
1400 |
|
Test charges Rs. 1100/- plus Rs. 300/ Specimen charges (25% discount is not applicable in specimen charges) |
| 7.1-Table 1(xii)(REQUlREMENTS-Moisture movernent
) |
- |
700 |
|
Nil |
| 7.1-Table 1(xiii)(REQUlREMENTS-Heat ageing and exudation
) |
- |
10100 |
|
Test charges Rs. 1100/- plus Rs. 9000/- Conditioning charges (25% discount is not applicable in Conditioning charges) |
| 7.1-Table 1(xiii)(REQUlREMENTS-Elastic product) |
- |
1350 |
|
Test charges Rs. 1100/- plus Rs. 250/ Specimen charges (25% discount is not applicable in specimen charges) |
|
Complete
|
|
31 Dec, 2023 |
- Included w.e.f. 29.06.2017. |
| 86 |
IS 5175 (2014) |
Fibre ropes – Polypropylene split film, monofilament and multifilament (PP2) and polypropylene high- tenacity multifilament (PP3) – 3-, 4-, 8- and 12-strand ropes (third revision) |
- |
-
|
6300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4( Designation) |
- |
0 |
|
Nil |
| Cl 5(General Requirements) |
- |
3950 |
|
Nil |
| Cl 6 & Table 1,2 or 3(Reference Number.) |
- |
750 |
|
Nil |
| Cl 6 & Table 1,2 or 3(Linear Density) |
- |
500 |
|
Nil |
| Cl 6 & Table 1,2 or 3(Breaking Force) |
- |
1100 |
|
Nil |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 87 |
IS 4984 (2016) |
Polyethylene pipes for water supply - Specification (Fifth Revision) |
- |
-
|
42325 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1(Slow Crack Growth Rate) |
- |
5500 |
|
NIl |
| 8.9 table-6(Elongation at Break) |
- |
1100 |
|
Nil |
| 8.8(Tensile Strength for Butt-fusion) |
- |
1100 |
|
Nil |
| 8.7(Density) |
- |
500 |
|
Nil |
| 8.5 (Oxidation Induction Time) |
- |
2200 |
|
Nil |
| 8.4( Melt Flow Rate) |
- |
1100 |
|
Nil |
| 8.2(Longitudinal Reversion Test) |
- |
1100 |
|
Nil |
| 8.1.2 table -5(Internal Pressure Creep Rupture Test of Pipe Joints) |
- |
1600 |
|
Nil |
| 8,/8.1/8.1.1 table-5(PERFORMANCE REQUIREMENTS / Hydraulic Characteristics/ Internal Pressure Creep Rupture Test of Pipe) |
- |
22000 |
|
Nil |
| 7.4.1.2(Ovality) |
- |
250 |
|
Nil |
| 7.4 table -3 & 4(6.1 Dimensions) |
- |
250 |
|
Nil |
| 7.2(Length) |
- |
250 |
|
Nil |
| 6.2.1(6.1.1 Identification Stripes) |
- |
250 |
|
Nil |
| 6.2(Colour) |
- |
250 |
|
Nil |
| 6.1.4(PIPE DESCRIPTION) |
- |
250 |
|
Nil |
| 6.1.3 (PIPE DESCRIPTION) |
- |
0 |
|
Nil |
| 6, 6.1.2(PIPE DESCRIPTION) |
- |
0 |
|
Nil |
| 6, 6.1.1(PIPE DESCRIPTION) |
- |
0 |
|
Nil |
| 6, 6.1(PIPE DESCRIPTION) |
- |
0 |
|
Nil |
| 8.6(Overall migration) |
- |
2200 |
|
Nil |
| 8.3(Carbon black) |
- |
925 |
|
Nil |
| 5.3 (a)(Carbon Black Master Batch) |
- |
925 |
|
Nil |
| 5.2(Polyethylene Resin) |
- |
2000 |
|
Nil |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 88 |
IS 10124 : Part 2 (2009) |
Fabricated pvc - U fittings for potable water supplies - Specification: Part 2 specific requirements for sockets (Second Revision) |
- |
-
|
4450 View breakup
Rs.1444/-,
Rs.3075/- PVC Resin
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2.1, Table-1, Fig-1(Nominal size) |
- |
250 |
|
NIL |
| 3.2.1, Table-1, Fig-1(B) |
- |
0 |
|
CHARGES ALREADY TAKEN IN CLAUSE NO. 3.2.1 |
| 3.2.1, Table-1, Fig-1(Minimum wall thickness for working pressure) |
- |
0 |
|
CHARGES ALREADY TAKEN IN CLAUSE NO. 3.2.1 |
| 3.2.1, Table-1, Fig-1(Plumbing) |
- |
0 |
|
CHARGES ALREADY TAKEN IN CLAUSE NO. 3.2.1 |
| Clause 3.2.2, and Fig. 2(Nominal size) |
- |
250 |
|
NIL |
| Clause 3.2.2, and Fig. 2.(B) |
- |
0 |
|
CHARGES ALREADY TAKEN IN CLAUSE NO. 3.2.2 |
| Clause 3.2.2, and Fig. 2.(Minimum wall thickness for working pressure) |
- |
0 |
|
CHARGES ALREADY TAKEN IN CLAUSE NO. 3.2.2 |
| 3.2.2, and Fig. 2(Dimensions of Socket for Elastomeric Sealing Ring Joint) |
- |
0 |
|
CHARGES ALREADY TAKEN IN CLAUSE NO. 3.2.2 |
| 10.3 of IS 4985 & Cl. 3.1 of IS 12235(P-4)(Effect on water: Lead (First Extraction)) |
- |
3000 |
|
NIL |
| 10.3 of IS 4985 & Cl. 3.1 of IS 12235(P-4)(Effect on water: Lead (Third Extraction)) |
- |
0 |
|
NIL |
| 10.3 of IS 4985 & Cl. 3.1 of IS 12235(P-10)(Effect on water:Dialkyl tin C4 and
higher homologues
measured as tin (third
extraction)) |
- |
0 |
|
NIL |
| 10.3 of IS 4985 & Cl. 3.2 of IS 12235(P-4)(Effect on water: Cadmium (all three extracts)) |
- |
0 |
|
NIL |
| 10.3 of IS 4985 & Cl. 3.2 of IS 12235(P-4)(Effect on water: Mercury (all three extracts)) |
- |
0 |
|
NIL |
| 10.7 of IS 4985(Sulphated Ash content, Annex-B of IS 4985) |
- |
950 |
|
NIL |
|
Complete
|
|
31 Dec, 2023 |
- upto 600mm dia |
| 89 |
IS 7834 : Part 3 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 3 Specific requirements for 90 degree elbows |
- |
-
|
3500 View breakup
Rs.4219/-,
Rs.3075/- PVC Resin
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| cl 2.2.2(Dimensions) |
- |
500 |
|
NIL |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (first extraction) - Appendix C ) |
- |
3000 |
|
NIL |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (third extraction) - Appendix C) |
- |
0 |
|
NIL |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Dialkyl tin C4 and higher homologues measured as tin (third extraction) - Appendix C) |
- |
0 |
|
NIL |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Other toxic substances (third extraction) - Appendix C) |
- |
0 |
|
NIL |
|
Complete
|
|
31 Dec, 2023 |
- 0.0 |
| 90 |
IS 7834 : Part 1 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 1 General requirements |
- |
-
|
5625 View breakup
Rs.4219/-,
Rs.3075/- PVC Resin
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4(Minimum Thickness) |
- |
250 |
|
NIL |
| Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Minimum Socket Length) |
- |
250 |
|
NIL |
| Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Mean Socket Internal Diameter at Mid-Point of Socket Length) |
- |
0 |
|
NIL |
| Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Out-of-roundness tolerances of socket inside diameter) |
- |
0 |
|
NIL |
| Cl. 6.1(Stress Relief Test- Appendix A) |
- |
700 |
|
NIL |
| Cl. 6.2(Opacity- Appendix B) |
- |
575 |
|
NIL |
| Cl. 6.3(Effect on Water[(Lead ( first extraction )]- Appendix C) |
- |
3000 |
|
NIL |
| Cl. 6.3(Effect on Water[(Lead ( third extraction )]- Appendix C) |
- |
0 |
|
NIL |
| Cl. 6.3(Effect on Water [Dialkyl tin C4, and higher homologues, measured as tin ( third extraction )]- Appendix C) |
- |
0 |
|
NIL |
| Cl. 6.3(Effect on Water [Other toxic substances ( third extraction )]- Appendix C) |
- |
0 |
|
NIL |
| Cl. 6.4(Short-Term Hydraulic Test- Appendix D) |
- |
850 |
|
NIL |
|
Complete
|
|
31 Dec, 2023 |
- 0.0 |