| 31 |
IS 15884 (2010) |
Alternating current direct connected static prepayment meters for active energy (Class 1 And 2) - Specification |
- |
-
|
253500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1(By Inspection) |
- |
0 |
|
- |
| 4.1.2(By Inspection) |
- |
0 |
|
- |
| 4.1.3(By Inspection) |
- |
0 |
|
- |
| 4.1.4(By Inspection) |
- |
0 |
|
- |
| 4.2(Mechanical Requirements) |
- |
0 |
|
- |
| 4.2.1(By Inspection) |
- |
0 |
|
- |
| 4.2.2(By Inspection) |
- |
0 |
|
- |
| 4.2.3(By Inspection) |
- |
0 |
|
- |
| 4.2.4(IS 13360 (Part 6/Sec 17) for a temperature of 135°C and a pressure of 1.8 MPa (Method A).) |
- |
0 |
|
- |
| 4.2.4(By Inspection) |
- |
0 |
|
- |
| 4.2.4(By inserting copper conductor of appropriate size) |
- |
0 |
|
- |
| 4.2.5(shall have a separate cover which can be sealed independently of the meter cover. The terminal cover shall enclose the actual terminals) |
- |
0 |
|
- |
| 4.2.5(The terminals their fixing screws, a suitable length of external insulated conductor and its insulation shall be enclosed by a cover with a provision for sealing. ) |
- |
0 |
|
- |
| 4.2.5(The fixing screws used on the terminal cover for fixing and sealing shall be held captive in the terminal cover.) |
- |
0 |
|
- |
| 4.2.5(When the meter is mounted on the meter board, no access to the terminals shall be possible without breaking the seal of the terminal cover.) |
- |
0 |
|
- |
| 4.2.6(By measurement) |
- |
1500 |
|
- |
| 4.2.7(Standard test fingure) |
- |
0 |
|
- |
| 4.2.10(Display of measured values) |
- |
3000 |
|
- |
| 4.2.10.1(By inspection) |
- |
3000 |
|
- |
| 4.2.10.2(By inspection) |
- |
3000 |
|
- |
| 4.2.10.3(By measurement) |
- |
3000 |
|
- |
| 4.2.10.4(By inspection) |
- |
3000 |
|
- |
| 4.2.10.5(By inspection) |
- |
3000 |
|
- |
| 4.2.10.6(By inspection) |
- |
3000 |
|
- |
| 4.2.10.7(By inspection) |
- |
3000 |
|
- |
| 4.2.10.8(Fig. 4, annexure F) |
- |
3000 |
|
- |
| 4.2.10.9(Fig. 5, annexure F) |
- |
3000 |
|
- |
| 4.2.11(By inspection) |
- |
0 |
|
- |
| 4.2.11.1(By inspection) |
- |
0 |
|
- |
| 5.4.6(As per IS 2071 (Part1)) |
- |
17500 |
|
- |
| 5.4.6.2(6 KV, As per cl 12.7.6.2 of IS 13779) |
- |
17500 |
|
- |
| 5.4.6.2(12.7.6.2 of IS 13779) |
- |
17500 |
|
- |
| 5.4.6.3(Table 15, power source 500 VA) |
- |
17500 |
|
- |
| 5.4.6.4(500±50V dc) |
- |
17500 |
|
- |
| 5.6(As per cl 4.6) |
- |
12500 |
|
- |
| 5.6.4(As per cl 4.6.3, Table 13) |
- |
12500 |
|
- |
| 5.6.3(I= open circuit
V= 115% of rated voltage
test period 60 000/k minutes) |
- |
12500 |
|
- |
| 5.6.7(Test shall be carried out at 0.05Ib and Ib at UPF load under reference conditions. Twenty error samples shall be taken at time-intervals of 30 minutes) |
- |
12500 |
|
- |
| 4.6.2(As per table 12) |
- |
12500 |
|
- |
| 5.4(As per 5.6.1) |
- |
10000 |
|
- |
| 5.4.1(As per 4.4.1.1) |
- |
10000 |
|
- |
| 4.4.2(Table 7) |
- |
10000 |
|
- |
| 5.4.2(As per 4.4.2.1) |
- |
10000 |
|
- |
| 5.4.3(Table 8, as per cl4.4.3) |
- |
12500 |
|
- |
| 5.4.4(Table 9, and cl 4.4.4) |
- |
12500 |
|
- |
| 5.4.5(As per cl 4.4.5) |
- |
12500 |
|
- |
| 5.5(Test of electromagnetic compatibility) |
- |
65000 |
|
- |
| 5.5.5(according to IEC 62052-11) |
- |
65000 |
|
- |
| 5.5.4(according to IS 14700
(Part 4/Sec 4)) |
- |
65000 |
|
- |
| 5.5.2(the load switch shall not
operate during the tests.) |
- |
65000 |
|
- |
| 5.5.2(according to IS 14700 (Part 4/Sec 2)) |
- |
65000 |
|
- |
| 5.5.6(Surge Immunity Test) |
- |
65000 |
|
- |
| 5.5.6(according to IEC 61000-
4-5) |
- |
65000 |
|
- |
| 5.3(Tests of Climatic Influences) |
- |
22500 |
|
- |
| 5.3.1(according to IS 9000
(Part 3/ Sec 1 to 5)) |
- |
22500 |
|
- |
| 5.3.2(according to IS 9000
(Part 2/Sec 1 to 4)) |
- |
22500 |
|
- |
| 5.3.3(according to IS 9000 (Part 5/Sec 1 and 2)) |
- |
22500 |
|
- |
| 5.3.3(As per cl 5.4.6) |
- |
22500 |
|
- |
| 5.3.3(Visual examination) |
- |
0 |
|
- |
| 5.2(Test of mechanical requirements) |
- |
17500 |
|
- |
| 5.2.3(As per IS 9000 (Part 8)) |
- |
17500 |
|
- |
| 5.2.2(As per IS 9000 (Part 7/Sec 1)) |
- |
17500 |
|
- |
| 5.2.1(As per cl 12.3.3 of IS 13779) |
- |
17500 |
|
- |
| 5.2.5(Protection against penetration of dust (IP5X)) |
- |
17500 |
|
- |
| 5.2.5(As per IS 12063) |
- |
17500 |
|
- |
| 5.2.5(500 V dc) |
- |
17500 |
|
- |
| 5.2.5(Protection against penetration of water (IP1X)) |
- |
17500 |
|
- |
| 5.2.5(As per IS 12063) |
- |
17500 |
|
- |
| 5.2.5(500 V dc) |
- |
17500 |
|
- |
| 5.2.4(As per IS 11000 (Part 2 / Sec1)) |
- |
17500 |
|
- |
| 4.6.3(Limits of error due to Ambient temperature Variation) |
- |
12500 |
|
- |
| 4.6.6.2.2(Performance requirement for load switching Utilization category UC2
(Annex G.)) |
- |
5000 |
|
- |
| 4.6.6.2 , annexure G -7(Performance requirements for Prepayment Meters with Load switching utilization category UC2 and UC3) |
- |
5000 |
|
- |
| 4.6.6.2 , annexure G -6(Performance requirements for Prepayment Meters with Load switching utilization category UC2 and UC3) |
- |
5000 |
|
- |
| 4.6.6.2 , annexure G -5(Performance requirements for Prepayment Meters with Load switching utilization category UC2 and UC3) |
- |
5000 |
|
- |
| 4.6.6.2 , annexure G -4(Performance requirements for Prepayment Meters with Load switching utilization category UC2 and UC3) |
- |
5000 |
|
- |
| 4.6.6.2 , annexure G -3(Performance requirements for Prepayment Meters with Load switching utilization category UC2 and UC3) |
- |
5000 |
|
- |
| 4.6.6.2 , annexure G -2(Performance requirements for Prepayment Meters with Load switching utilization category UC2 and UC3) |
- |
5000 |
|
- |
| 4.6.6.2 .1(Load switching capability) |
- |
5000 |
|
- |
| 4.6.6.1 , annexure D - 4.3(Test of crystal Controlled Clocks in Payment Meters) |
- |
5000 |
|
- |
| 4.6.6.1 , annexure D - 4.2(Test of crystal Controlled Clocks in Payment Meters) |
- |
5000 |
|
- |
| 4.6.6.1 , annexure D - 4.1(Test of crystal Controlled Clocks in Payment Meters) |
- |
5000 |
|
- |
| 4.6.6.1 , annexure D - 3.2.3(Test of crystal Controlled Clocks in Payment Meters) |
- |
5000 |
|
- |
| 4.6.6.1 ,annexure D - 3.2.2(Test of crystal Controlled Clocks in Payment Meters) |
- |
5000 |
|
- |
| 4.6.6.1 ,annexure D - 3.2.1(Test of crystal Controlled Clocks in Payment Meters) |
- |
5000 |
|
- |
| 4.2.12(Test on Token Carrier Interface) |
- |
3000 |
|
- |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 32 |
IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
Fixed General Purpose LED Luminaires |
-
|
52500 View breakup
Rs.52500/-
(5% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
| 6.0(Marking) |
- |
500 |
|
5% discount for BIS |
| 7.0(Construction) |
- |
3000 |
|
5% discount for BIS |
| 8.0(Creepage Distance and Clearances) |
- |
1000 |
|
5% discount for BIS |
| 9.0(Provision for earthing) |
- |
1000 |
|
5% discount for BIS |
| 10.0(Terminals) |
- |
2500 |
|
5% discount for BIS |
| 11.0(External & Internal Wiring) |
- |
1500 |
|
5% discount for BIS |
| 12.0(Protection against electric shock) |
- |
1500 |
|
5% discount for BIS |
| 13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
5% discount for BIS |
| 14.0(Resistance to Dust & Moisture) |
- |
12500 |
|
5% discount for BIS |
| 15.0(Insulation Resistance and Electric Strength) |
- |
5000 |
|
5% discount for BIS |
| 16.0(Resistance to Heat , fire and tracking) |
- |
2500 |
|
5% discount for BIS |
| 17.0(Photometric Test) |
- |
11500 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 33 |
IS 10322 : Part 5 : Sec 2 (2012) |
Luminaires: Part 5 particular requirements: Sec 2 recessed luminaires (First Revision) |
Recessed LED Luminaires |
-
|
60000 View breakup
Rs.60000/-
(5 % discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
| 6(Marking) |
- |
500 |
|
5% discount for BIS |
| 7(Construction) |
- |
3000 |
|
5% discount for BIS |
| 8(Creepage Distance and Clearances) |
- |
1000 |
|
5% discount for BIS |
| 9(Provision for earthing) |
- |
1000 |
|
5% discount for BIS |
| 10(Terminals) |
- |
2500 |
|
5% discount for BIS |
| 11(External & Internal Wiring) |
- |
2000 |
|
5% discount for BIS |
| 12(Protection against electric shock) |
- |
1000 |
|
5% discount for BIS |
| 13(Endurance Tests and Thermal Tests) |
- |
12000 |
|
5% discount for BIS |
| 14(Resistance to Dust and Moisture) |
- |
15000 |
|
5% discount for BIS |
| 15(Insulation Resistance and Electric Strength) |
- |
4000 |
|
5% discount for BIS |
| 16(Resistance to Heat , fire and tracking) |
- |
3000 |
|
5% discount for BIS |
| 17(Photometric Test) |
- |
15000 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 34 |
IS 10322 : PART 5 : SEC 3 (2012) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
Luminaires for Road and Street Lighting |
-
|
75000 View breakup
Rs.75000/-
(5% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
| 6.0(Marking) |
- |
500 |
|
5% discount for BIS |
| 7.0(Construction) |
- |
4500 |
|
5% discount for BIS |
| 8.0(Creepage Distance and Clearances) |
- |
1000 |
|
5% discount for BIS |
| 9.0(Provision for earthing) |
- |
1000 |
|
5% discount for BIS |
| 10.0(Terminals) |
- |
3000 |
|
5% discount for BIS |
| 11.0(External & Internal Wiring) |
- |
2000 |
|
5% discount for BIS |
| 12.0(Protection against electric shock) |
- |
1000 |
|
5% discount for BIS |
| 13.0(Endurance Tests and Thermal Tests) |
- |
19000 |
|
5% discount for BIS |
| 14.0(Resistance to Dust & Moisture) |
- |
20000 |
|
5% discount for BIS |
| 15.0(Insulation Resistance and Electric Strength) |
- |
5000 |
|
5% discount for BIS |
| 16.0(Resistance to Heat , fire and tracking) |
- |
3000 |
|
5% discount for BIS |
| 17.0(Photometric Test) |
- |
15000 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 35 |
IS 15636 (2012) |
Automotive vehicles - Pneumatic tyres for commercial vehicles - Diagonal and radial ply - Specification (First Revision) |
- |
-
|
100000 View breakup
Rs.100000/-
(5% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5, 8(Marking) |
- |
500 |
|
5% discount for BIS |
| 4..1(Tyre Dimensions) |
- |
2000 |
|
5% discount for BIS |
| 4.2(Endurance test) |
- |
75000 |
|
5% discount for BIS |
| 4.3.1(Load/Speed performance test) |
- |
13000 |
|
5% discount for BIS |
| 4,4,1(Tread -wear indicators) |
- |
1000 |
|
5% discount for BIS |
| 4.5(Tyre strength test (Plunger rest)) |
- |
8500 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 36 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
DC or AC Supplied Electronic Controlgear for LED Module |
-
|
45000 View breakup
Rs.45000/-
(5% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
500 |
|
5% discount for BIS |
| 8(Protection against accidental contact with live parts) |
- |
1500 |
|
5% discount for BIS |
| 9(Terminals) |
- |
2500 |
|
5% discount for BIS |
| 10(PROVISION FOR EARTHING) |
- |
1000 |
|
5% discount for BIS |
| 11(MOISTURE RESISTANCE) |
- |
5000 |
|
5% discount for BIS |
| 12(Electric Strength) |
- |
2000 |
|
5% discount for BIS |
| 13(Thermal endurance test for winding of ballasts) |
- |
6000 |
|
5% discount for BIS |
| 14(Fault conditions) |
- |
1500 |
|
5% discount for BIS |
| 15(Transformer heating) |
- |
4000 |
|
5% discount for BIS |
| 16(Construction) |
- |
8000 |
|
5% discount for BIS |
| 17(Creepage distance and clearances) |
- |
2000 |
|
5% discount for BIS |
| 18(Screws, current carrying parts and connections) |
- |
3000 |
|
5% discount for BIS |
| 19(Resistance to heat, fire and tracking) |
- |
5000 |
|
5% discount for BIS |
| 20(Resistance to corrosion) |
- |
3000 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 37 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
-
|
46000 View breakup
Rs.46000/-
(5 % discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
500 |
|
5% discount for BIS |
| 6(Interchangeability) |
- |
3000 |
|
5% discount for BIS |
| 7(Protection against accidental contact with live parts) |
- |
2000 |
|
5% discount for BIS |
| 8(Insulation Resistance and Electric Strength) |
- |
8500 |
|
5% discount for BIS |
| 9(MECHANICAL STRENGTH) |
- |
8500 |
|
5% discount for BIS |
| 10(cap temperature) |
- |
6000 |
|
5% discount for BIS |
| 11(Resistance to Heat) |
- |
5000 |
|
5% discount for BIS |
| 12(Resistance to Flame and Ignition) |
- |
5500 |
|
5% discount for BIS |
| 13(Fault conditions) |
- |
5000 |
|
5% discount for BIS |
| 14(Creepage distance and clearances) |
- |
2000 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 38 |
IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
LED Modules for General Lighting |
-
|
58500 View breakup
Rs.58500/-
(5% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
1000 |
|
5% discount for BIS |
| 8(Terminals) |
- |
3000 |
|
5% discount for BIS |
| 9(PROVISION FOR EARTHING) |
- |
2000 |
|
5% discount for BIS |
| 10(Protection against accidental contact with live parts) |
- |
3000 |
|
5% discount for BIS |
| 11(Mositure Resistance and Insulation) |
- |
10000 |
|
5% discount for BIS |
| 12(Electric Strength) |
- |
4000 |
|
5% discount for BIS |
| 13(Fault conditions) |
- |
4000 |
|
5% discount for BIS |
| 15(Construction) |
- |
10500 |
|
5% discount for BIS |
| 16(Creepage distance and clearances) |
- |
2000 |
|
5% discount for BIS |
| 17(Screws, current carrying parts and connections) |
- |
3000 |
|
5% discount for BIS |
| 18(Resistance to heat, fire and tracking) |
- |
8000 |
|
5% discount for BIS |
| 19(Resistance to corrosion) |
- |
8000 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 39 |
IS 16103 : Part 2 (2012) |
Led modules for general lighting: Part 2 performance requirements |
LED Modules for General Lighting – Performance |
-
|
280000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Dimensions) |
- |
1000 |
|
5% discount to BIS |
| 7(Module Power) |
- |
3000 |
|
5% discount to BIS |
| 8(Light Output) |
- |
22000 |
|
5% discount to BIS |
| 9(Chromaticity
Coordinates,
Correlated colour
temperature and
colour rendering) |
- |
21500 |
|
5% discount to BIS |
| 10(LED Module Life) |
- |
180000 |
|
5% discount to BIS |
| 12(Information for
Luminaire design) |
- |
5000 |
|
5% discount to BIS |
| 13(Test for Emission
(Radiated and Conducted)
of radio frequency
distribution) |
- |
40000 |
|
5% discount to BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 40 |
IS 16104 (2012) |
D.C. or A.C. supplied electronic control gear for led modules - Performance requirements |
A.C or D.C Supplied Electronic Controlgear for LED Modu |
-
|
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Classification) |
- |
250 |
|
5% discount to BIS |
| 6(Marking) |
- |
250 |
|
5% discount to BIS |
| 7.2(Output voltage and
Current) |
- |
2000 |
|
5% discount to BIS |
| 7.3(Capacitive Load
Requirement) |
- |
5000 |
|
5% discount to BIS |
| 7.4(Voltage surge during
switching and operation) |
- |
7500 |
|
5% discount to BIS |
| 8(Total Circuit
Power) |
- |
5000 |
|
5% discount to BIS |
| 9(Circuit Power
Factor) |
- |
5000 |
|
5% discount to BIS |
| 10(Supply Current) |
- |
5000 |
|
5% discount to BIS |
| 12(Operational test
for abnormal conditions) |
- |
5000 |
|
5% discount to BIS |
| 13(Endurance) |
- |
10000 |
|
5% discount to BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 41 |
IS 16107 : Part 1 (2012) |
Luminaires performance: Part 1 general requirements |
Luminaires Performance |
-
|
70000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2(Photometric and Electrical Data) |
- |
70000 |
|
5% Discount to BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 42 |
IS 16107 : Part 2 : Sec 1 (2012) |
Luminaires performance: Part 2 particular requirements: Sec 1 led luminaire |
Luminaires Performance |
-
|
250500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Total Input Power) |
- |
15500 |
|
5% Discount to BIS |
| 8(Light Output) |
- |
30000 |
|
5% Discount to BIS |
| 9(Chromaticity
Coordinates,
Correlated
colour temperature
and colour rendering) |
- |
30000 |
|
5% Discount to BIS |
| 10(LED Luminaire
Life) |
- |
175000 |
|
5% Discount to BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 43 |
IS 10322 : Part 5 : Sec 5 (2013) |
Luminaires: Part 5 particular requirements: Sec 5 floodlights (First Revision) |
LED Flood Lights |
-
|
45000 View breakup
Rs.45000/-
(5% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
| 6.0(Marking) |
- |
500 |
|
5% discount for BIS |
| 7.0(Construction) |
- |
5000 |
|
5% discount for BIS |
| 8.0(Creepage Distance and Clearances) |
- |
1500 |
|
5% discount for BIS |
| 9.0(Provision for earthing) |
- |
1500 |
|
5% discount for BIS |
| 10.0(Terminals) |
- |
1500 |
|
5% discount for BIS |
| 11.0(External & Internal Wiring) |
- |
1500 |
|
5% discount for BIS |
| 12.0(Protection against electric shock) |
- |
1500 |
|
5% discount for BIS |
| 13.0(Endurance Tests and Thermal Tests) |
- |
5000 |
|
5% discount for BIS |
| 14.0(Resistance to Dust & Moisture) |
- |
7500 |
|
5% discount for BIS |
| 15.0(Insulation Resistance and Electric Strength) |
- |
8000 |
|
5% discount for BIS |
| 16.0(Resistance to Heat , fire and tracking) |
- |
4000 |
|
5% discount for BIS |
| 17.0(Photometric Test) |
- |
7500 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 44 |
IS 10322 : Part 5 : Sec 6 (2013) |
Luminaires: Part 5 particular requirements: Sec 6 handlamps |
LED Hand Lamps |
-
|
55000 View breakup
Rs.55000/- (5% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
| 6.0(Marking) |
- |
500 |
|
5% discount for BIS |
| 7.0(Construction) |
- |
5000 |
|
5% discount for BIS |
| 8.0(Creepage Distance and Clearances) |
- |
2500 |
|
5% discount for BIS |
| 9.0(Provision for earthing) |
- |
2500 |
|
5% discount for BIS |
| 10.0(Terminals) |
- |
1500 |
|
5% discount for BIS |
| 11.0(External & Internal Wiring) |
- |
1500 |
|
5% discount for BIS |
| 12.0(Protection against electric shock) |
- |
1500 |
|
5% discount for BIS |
| 13.0(Endurance Tests and Thermal Tests) |
- |
5000 |
|
5% discount for BIS |
| 14.0(Resistance to Dust & Moisture) |
- |
20000 |
|
5% discount for BIS |
| 15.0(Insulation Resistance and Electric Strength) |
- |
10000 |
|
5% discount for BIS |
| 16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 45 |
IS 10322 : Part 5 : Sec 8 (2013) |
Luminaires: Part 5 particular requirements: Sec 8 emergency lighting |
Emergency Lighting |
-
|
100000 View breakup
Rs.100000/-
(5% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
| 6.0(Marking) |
- |
500 |
|
5% discount for BIS |
| 7.0(Construction) |
- |
5000 |
|
5% discount for BIS |
| 8.0(Creepage Distance and Clearances) |
- |
2500 |
|
5% discount for BIS |
| 9.0(Provision for earthing) |
- |
2500 |
|
5% discount for BIS |
| 10.0(Terminals) |
- |
2000 |
|
5% discount for BIS |
| 11.0(External & Internal Wiring) |
- |
2500 |
|
5% discount for BIS |
| 12.0(Protection against electric shock) |
- |
5000 |
|
5% discount for BIS |
| 13.0(Endurance Tests and Thermal Tests) |
- |
5000 |
|
5% discount for BIS |
| 14.0(Resistance to Dust & Moisture) |
- |
17500 |
|
5% discount for BIS |
| 15.0(Insulation Resistance and Electric Strength) |
- |
10000 |
|
5% discount for BIS |
| 16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
5% discount for BIS |
| 17.0(Functional Safety) |
- |
5000 |
|
5% discount for BIS |
| 18.0(Changeover Operation) |
- |
15000 |
|
5% discount for BIS |
| 19.0(High Temperature Operation) |
- |
15000 |
|
5% discount for BIS |
| 20.0(BATTERY CHARGERS FOR SELFCONTAINED EMERGENCY LUMINAIRES) |
- |
7500 |
|
5% discount for BIS |
| 21.0(TEST DEVICES FOR EMERGENCY OPERATION) |
- |
0 |
|
- |
| 22.0(REST MODE AND INIHIBITION MODE FACILITIES) |
- |
0 |
|
- |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 46 |
IS 16077 (2013) |
Thin - Film terrestrial photovoltaic (PV) modules - Design qualification and type approval |
THIN-FILM TERRESTRIAL PHOTOVOLTAIC (PV) MODULES |
-
|
805000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Marking) |
- |
0 |
|
N/A |
| 10.1(Visual inspection) |
- |
7500 |
|
5% discount for BIS |
| 10.2(Maximum power determination) |
- |
12500 |
|
5% discount for BIS |
| 10.3(Insulation test) |
- |
15000 |
|
5% discount for BIS |
| 10.4(Measurement of temperature coefficients) |
- |
55000 |
|
5% discount for BIS |
| 10.5(Measurement of NOCT) |
- |
55000 |
|
5% discount for BIS |
| 10.6(Performance at STC and NOCT) |
- |
60000 |
|
5% discount for BIS |
| 10.7(Performance at low irradiance) |
- |
60000 |
|
5% discount for BIS |
| 10.8(Outdoor exposure test) |
- |
32500 |
|
5% discount for BIS |
| 10.9(Hot-spot endurance test) |
- |
85000 |
|
5% discount for BIS |
| 10.10(UV preconditioning) |
- |
47500 |
|
5% discount for BIS |
| 10.11(Thermal cycling test) |
- |
65000 |
|
5% discount for BIS |
| 10.12(Humidity freeze test) |
- |
62500 |
|
5% discount for BIS |
| 10.13(Damp heat test) |
- |
45000 |
|
5% discount for BIS |
| 10.14(Robustness of termination test) |
- |
20000 |
|
5% discount for BIS |
| 10.15(Wet leakage current test) |
- |
25000 |
|
5% discount for BIS |
| 10.16(Mechanical load test) |
- |
27500 |
|
5% discount for BIS |
| 10.17(Hail test) |
- |
60000 |
|
5% discount for BIS |
| 10.18(Bypass diode thermal' test) |
- |
27500 |
|
5% discount for BIS |
| 10.19(Light Soaking) |
- |
42500.01 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 47 |
IS 302 : Part 2 : Sec 26 (2014) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 26 clocks (First Revision) |
Digital Clocks |
-
|
55000 View breakup
Rs.55000/- (5% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
500 |
|
5% discount for BIS |
| 7(Marking and instructions) |
- |
750 |
|
5% discount for BIS |
| 8(Protection against live parts) |
- |
1500 |
|
5% discount for BIS |
| 10(POWER INPUT AND CURRENT) |
- |
2500 |
|
5% discount for BIS |
| 11(HEATING) |
- |
4000 |
|
5% discount for BIS |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
2000 |
|
5% discount for BIS |
| 14(TRANSIENT OVERVOLTAGES) |
- |
3000 |
|
5% discount for BIS |
| 15(MOISTURE RESISTANCE) |
- |
7500 |
|
5% discount for BIS |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
2000 |
|
5% discount for BIS |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1250 |
|
5% discount for BIS |
| 19(ABNORMAL OPERATION) |
- |
2500 |
|
5% discount for BIS |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
1250 |
|
5% discount for BIS |
| 21(MECHANICAL STRENGTH) |
- |
1250 |
|
5% discount for BIS |
| 22(CONSTRUCTION) |
- |
1500 |
|
5% discount for BIS |
| 23(INTERNAL WIRING) |
- |
2000 |
|
5% discount for BIS |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
2000 |
|
5% discount for BIS |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
2000 |
|
5% discount for BIS |
| 27(PROVISION FOR EARTHING) |
- |
2000 |
|
5% discount for BIS |
| 28(SCREWS AND CONNECTIONS) |
- |
2000 |
|
5% discount for BIS |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
1000 |
|
5% discount for BIS |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
5000 |
|
5% discount for BIS |
| 31(RESISTANCE TO RUSTING) |
- |
2500 |
|
5% discount for BIS |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
3500 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 48 |
IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
-
|
160000 View breakup
Rs.80000/- for ≤ 5KVA
Rs.115000/- for ≥ 5KVA
(5% discount for BIS). Rs.1,85,000/- for > 10 KVA (for 3 phase)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
0 |
|
- |
| 4.6(Power interface) |
- |
5000 |
|
5% discount for BIS |
| 4.7(Marking & instructions) |
- |
2000 |
|
5% discount for BIS |
| 5.1(Protection against shock and energy hazards) |
- |
4000 |
|
5% discount for BIS |
| 5.2(Requirement of auxiliary circuits) |
- |
4000 |
|
5% discount for BIS |
| 5.3(Protective earthing and bonding) |
- |
7000 |
|
5% discount for BIS |
| 5.4(AC and DC power isolation) |
- |
3000 |
|
5% discount for BIS |
| 5.5(Over current and earth fault condition) |
- |
5000 |
|
5% discount for BIS |
| 5.6(Safety interlocks) |
- |
6000 |
|
5% discount for BIS |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
6000 |
|
5% discount for BIS |
| 6.1(Wiring, connections and supply) |
- |
12000 |
|
5% discount for BIS |
| 6.2(Connection to power) |
- |
13000 |
|
5% discount for BIS |
| 6.3(Wiring terminals for external power conductors) |
- |
10000 |
|
5% discount for BIS |
| 7.1(Enclosure) |
- |
1000 |
|
5% discount for BIS |
| 7.2(STABILITY) |
- |
2000 |
|
5% discount for BIS |
| 7.3(MECHANICAL STRENGTH) |
- |
2000 |
|
5% discount for BIS |
| 7.4(Construction details) |
- |
5000 |
|
5% discount for BIS |
| 7.5(Resistance to fire) |
- |
7000 |
|
5% discount for BIS |
| 7.6(Battery location) |
- |
3000 |
|
5% discount for BIS |
| 7.7(Temperature rise) |
- |
5000 |
|
5% discount for BIS |
| 8.1(General procision for earth leakage) |
- |
7000 |
|
5% discount for BIS |
| 8.2(Electric Strength) |
- |
8000 |
|
5% discount for BIS |
| 8.3(Abnormal operating and fault conditions) |
- |
15000 |
|
5% discount for BIS |
| 9.0(Connection to telecommunication networks) |
- |
28000 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 49 |
IS 16270 (2014) |
Secondary cells and batteries for solar photovoltaic application - General requirements and methods of test |
Storage Batteries |
-
|
601000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Condition of use) |
- |
0 |
|
- |
| 5.1(Mechanical Endurance) |
- |
0 |
|
- |
| 5.2(Charge efficiency) |
- |
0 |
|
- |
| 5.3(Deep discharge protection) |
- |
0 |
|
- |
| 5.4(Marking) |
- |
1000 |
|
5% discount for BIS |
| 5.5(Dafety) |
- |
0 |
|
- |
| 5.6(Documentation) |
- |
0 |
|
- |
| 6(Finctional Characteristics) |
- |
0 |
|
- |
| 7(General test conditions) |
- |
0 |
|
- |
| 8.1(Capacity test) |
- |
75000 |
|
5% discount for BIS |
| 8.2(Endurance test) |
- |
150000 |
|
5% discount for BIS |
| 8.3(Charge retention test) |
- |
75000 |
|
5% discount for BIS |
| 8.4(Cycle endurance in Photovoltaic application) |
- |
150000 |
|
5% discount for BIS |
| 8.5(Sulphation Test) |
- |
50000 |
|
5% discount for BIS |
| 8.6(Water loss test) |
- |
50000 |
|
5% discount for BIS |
| 8.7(Non spillability) |
- |
50000 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 50 |
IS 16221 : Part 2 (2015) |
Safety of power converters for use in photovoltaic power systems: Part 2 particular requirements for inverters |
- |
-
|
158500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
150000 |
|
5% discount for BIS |
| 5(Marking and documentation) |
- |
4000 |
|
5% discount for BIS |
| 6(Environmental requirements and conditions) |
- |
0 |
|
5% discount for BIS |
| 7(Protection against electric shock and energy hazards) |
- |
2000 |
|
5% discount for BIS |
| 8(Protection against Mechanical Hazards) |
- |
0 |
|
5% discount for BIS |
| 9(Protection against Fire Hazards) |
- |
2000 |
|
5% discount for BIS |
| 11(Protection against Liquid Hazards) |
- |
0 |
|
5% discount for BIS |
| 12(Protection against Chemical Hazards) |
- |
0 |
|
5% discount for BIS |
| 13(Physical Requirements) |
- |
500 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 51 |
IS 16444 (2015) |
AC static direct connected watthour smart meter class 1 and 2 - Specification |
- |
-
|
229500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| cl. 7.1 a) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
0 |
|
Charges Covered in Marking of smart meters Name plate Cl. 6.8 |
| cl. 7.1 b) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
0 |
|
Charges Covered in Marking of smart meters Name plate Cl. 6.8 |
| cl. 7.1 c) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
0 |
|
Charges Covered in Marking of smart meters Name plate Cl. 6.8 |
| cl. 7.1 d) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
0 |
|
Charges Covered in Marking of smart meters Name plate Cl. 6.8 |
| cl. 7.1 e) of of IS 13779(MARKING OF METERS : Name Plate
) |
- |
0 |
|
Charges Covered in Marking of smart meters Name plate Cl. 6.8 |
| cl. 7.1 f) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
0 |
|
Charges Covered in Marking of smart meters Name plate Cl. 6.8 |
| cl. 7.1 g) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
0 |
|
Charges Covered in Marking of smart meters Name plate Cl. 6.8 |
| cl. 7.1 h) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
0 |
|
Charges Covered in Marking of smart meters Name plate Cl. 6.8 |
| cl. 7.1 j) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
0 |
|
Charges Covered in Marking of smart meters Name plate Cl. 6.8 |
| cl. 7.1 k) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
0 |
|
Charges Covered in Marking of smart meters Name plate Cl. 6.8 |
| cl. 7.1 m) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
0 |
|
Charges Covered in Marking of smart meters Name plate Cl. 6.8 |
| cl. 7.1 p) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
0 |
|
Charges Covered in Marking of smart meters Name plate Cl. 6.8 |
| cl. 7.1 n) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
0 |
|
Charges Covered in Marking of smart meters Name plate Cl. 6.8 |
| 4.4.2.1 of IS 15844(Voltage range) |
- |
200 |
|
5% discount for BIS |
| 4.4.2.2 of IS 15844( Specified operating range
) |
- |
200 |
|
5% discount for BIS |
| 4.4.2.3 of IS 15844(Extended operating range) |
- |
200 |
|
5% discount for BIS |
| 4.4.2.4 of IS 15844( Limit range of operation) |
- |
200 |
|
5% discount for BIS |
| 4.4.2.5 of IS 15844(Withstand range) |
- |
200 |
|
5% discount for BIS |
| 4.4.2.6 of IS 15844(Abnormal voltage conditions) |
- |
1500 |
|
5% discount for BIS |
| 4.4.2.7 of IS 15844(Voltage dips and short interruptions) |
- |
2500 |
|
5% discount for BIS |
| 4.4.3 of IS 15844(Influence of Short-Time Overcurrents) |
- |
2500 |
|
5% discount for BIS |
| 6.8(BIS Standard Mark) |
- |
0 |
|
Charges Covered in Marking of smart meters Name plate Cl. 6.8 |
| 6.8(Marking of smart meters
Name plate) |
- |
500 |
|
5% discount for BIS |
| 6.3(Clearance and creepage distances) |
- |
200 |
|
5% discount for BIS |
| 11.0(Smart meter functional requirements) |
- |
5000 |
|
5% discount for BIS |
| 10.3(Test of Display) |
- |
200 |
|
5% discount for BIS |
| 8.0(Data Exchange for Electricity Meter Reading,
Tariff and Load Control Companion Specification (Verification up to two Port)) |
- |
42000 |
|
5% discount for BIS |
| 7.2, 10.4(Performance Requirements for Load Switching (UC1)) |
- |
8000 |
|
5% discount for BIS |
| 7.2, 10.4(Dielectric strength (G-8)) |
- |
4000 |
|
5% discount for BIS |
| 7.2, 10.4(Minimum switched current (G-7)) |
- |
2500 |
|
5% discount for BIS |
| 7.2, 10.4(Short circuit current carrying capacity (G-6)) |
- |
17000 |
|
5% discount for BIS |
| 7.2, 10.4(Fault current making capacity (G-5)) |
- |
17000 |
|
5% discount for BIS |
| 7.2, 10.4(Line to load voltage surge withstand (G-4)) |
- |
6000 |
|
5% discount for BIS |
| 7.2, 10.4(Electrical endurance (G-3)) |
- |
12000 |
|
5% discount for BIS |
| 7.2, 10.4(Normal operation (G-2)) |
- |
1500 |
|
5% discount for BIS |
| 6.5(Test of resistance to heat and fire) |
- |
2000 |
|
5% discount for BIS |
| Note 1c of Table 1(Remote disconnect/connect) |
- |
1000 |
|
5% discount for BIS |
| Note 1b of Table 1(Access and data read test) |
- |
800 |
|
5% discount for BIS |
| Note 1a of Table 1(Accuracy of the meter at pre-defined points) |
- |
200 |
|
5% discount for BIS |
| 6.5(Protection against penetration of dust and water) |
- |
4000 |
|
5% discount for BIS |
| 6.5(Spring Hammer test) |
- |
200 |
|
5% discount for BIS |
| 6.5(Shock test) |
- |
3500 |
|
5% discount for BIS |
| 6.5(Vibration test) |
- |
6000 |
|
5% discount for BIS |
| 6.9(Damp heat cyclic test) |
- |
5800 |
|
5% discount for BIS |
| 6.9(Cold test) |
- |
3000 |
|
5% discount for BIS |
| 6.9(Dry heat test) |
- |
1000 |
|
5% discount for BIS |
| 6.11(Surge Immunity test) |
- |
6000 |
|
5% discount for BIS |
| 6.11(Test of immunity to electrostatic discharge) |
- |
4000 |
|
5% discount for BIS |
| 6.11(Fast transient burst test) |
- |
10000 |
|
5% discount for BIS |
| 6.11(Radio interference measurement) |
- |
18000 |
|
5% discount for BIS |
| 6.10.7(Test of influence of immunity to earth fault) |
- |
2000 |
|
5% discount for BIS |
| 6.10.5(Test of influence of heating) |
- |
1500 |
|
5% discount for BIS |
| 6.10.4(Test of influence of self-heating) |
- |
1000 |
|
5% discount for BIS |
| 6.10.1(Test of power consumption) |
- |
600 |
|
5% discount for BIS |
| 6.12(Operation of Accessories) |
- |
500 |
|
5% discount for BIS |
| 6.12(Abnormal Magnetic Induction of External Origin 10mT) |
- |
1200 |
|
5% discount for BIS |
| 6.12(Magnetic induction of External Origin 0.5mT) |
- |
1200 |
|
5% discount for BIS |
| 6.12(Continuous Magnetic Induction of External Origin 0.2 Tesla) |
- |
1200 |
|
5% discount for BIS |
| 6.12(Continuous Magnetic Induction of External Origin 67 milli Tesla) |
- |
1200 |
|
5% discount for BIS |
| 6.12(DC & Even Harmonics in the ac current circuit) |
- |
1200 |
|
5% discount for BIS |
| 6.12(Voltage Unbalanced) |
- |
400 |
|
5% discount for BIS |
| 6.12(Reversed Phase Sequence) |
- |
400 |
|
5% discount for BIS |
| 6.12(Waveform 10% of 3rd Harmonics) |
- |
1000 |
|
5% discount for BIS |
| 6.12(Frequency Variation) |
- |
400 |
|
5% discount for BIS |
| 6.12(Voltage Variation) |
- |
400 |
|
5% discount for BIS |
| 6.12(Test of influence quantities) |
- |
0 |
|
Test wise charges as per added |
| 6.12(Test of repeatability of error ) |
- |
3000 |
|
5% discount for BIS |
| 6.12(Test of ambient temperature influence) |
- |
2000 |
|
5% discount for BIS |
| 6.12(Test of no-load condition) |
- |
500 |
|
5% discount for BIS |
| 6.12(Test of starting condition) |
- |
400 |
|
5% discount for BIS |
| 6.12(Test of meter constant) |
- |
1000 |
|
5% discount for BIS |
| 6.12(Test on limits of error due to variation of the current) |
- |
1800 |
|
5% discount for BIS |
| 6.10.6(Insulation resistance test) |
- |
500 |
|
5% discount for BIS |
| 6.10.6(ac high voltage test) |
- |
500 |
|
5% discount for BIS |
| 6.10.6(Impulse voltage test) |
- |
3000 |
|
5% discount for BIS |
| 6.8.1(Additional information) |
- |
0 |
|
Charges Covered in Marking of smart meters Name plate Cl. 6.8 |
| 6.8(Connection diagrams and terminal marking) |
- |
0 |
|
Charges Covered in Marking of smart meters Name plate Cl. 6.8 |
| 6.7(Output device) |
- |
1500 |
|
5% discount for BIS |
| 6.6(Display of measured values) |
- |
200 |
|
5% discount for BIS |
| 6.2.2(Insulating encased meter) |
- |
0 |
|
Charges Covered in General and constructional requirements Cl. 6.2 |
| 6.2.2(Terminal Cover(s)) |
- |
0 |
|
Charges Covered in General and constructional requirements Cl. 6.2 |
| 6.2.1(Heat Deflection Test) |
- |
0 |
|
Charges Covered in General and constructional requirements Cl. 6.2 |
| 6.2.1(Terminals, terminal block and protective earth ter-minal) |
- |
0 |
|
Charges Covered in General and constructional requirements Cl. 6.2 |
| 6.2(Communication module
Load switch) |
- |
0 |
|
Charges Covered in General and constructional requirements Cl. 6.2 |
| 6.2(Window) |
- |
0 |
|
Charges Covered in General and constructional requirements Cl. 6.2 |
| 6.2(Meter case) |
- |
0 |
|
Charges Covered in General and constructional requirements Cl. 6.2 |
| 6.2(General and constructional requirements) |
- |
2000 |
|
5% discount for BIS |
| Table 1 (Note 1)(Schedule of type tests) |
- |
0 |
|
Charges Covered in Note 1a, 1b, 1c of Table 1 |
| Table 1 (Note 1)(Schedule of type tests) |
- |
0 |
|
Charges Covered in Note 1a, 1b, 1c of Table 1 |
| 10.5(Test for Data Exchange Protocol) |
- |
0 |
|
Charges Covered in Data exchange protocol Cl. 8.0 |
| 10.6.2(Test for Smart meter communicability ) |
- |
10000 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 52 |
IS/IEC 61730 : PART 1 (2016) |
Photovoltaic (PV) Module Safety Qualification Part 1 Requirements for Construction ( First Revision ) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
19 Mar, 2023 |
- - |
| 53 |
IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
Audio, Video and Similar Electronic Apparatus — Safety |
-
|
52500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking and instructions) |
- |
1000 |
|
5% discount for BIS |
| 7(Heating under normal operating conditions) |
- |
3000 |
|
5% discount for BIS |
| 8(Constructional requirements with regard to the protection against electric shock) |
- |
8000 |
|
5% discount for BIS |
| 9(Electric shock hazard under normal operating conditions) |
- |
5000 |
|
5% discount for BIS |
| 10(Insulation requirements) |
- |
2000 |
|
5% discount for BIS |
| 11(Fault conditions) |
- |
5000 |
|
5% discount for BIS |
| 12(Mechanical strength) |
- |
2000 |
|
5% discount for BIS |
| 13(CLEARANCES and CREEPAGE DISTANCES) |
- |
1000 |
|
5% discount for BIS |
| 14(Components) |
- |
0 |
|
Nil |
| 15(TERMINALS) |
- |
2000 |
|
5% discount for BIS |
| 16(External flexible cords) |
- |
2000 |
|
5% discount for BIS |
| 17(Electrical connections and mechanical fixings) |
- |
5000 |
|
5% discount for BIS |
| 19(Stability and mechanical hazards) |
- |
3000 |
|
5% discount for BIS |
| 20(Resistance to fire) |
- |
2000 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 54 |
IS 9873 : Part 2 (2017) |
Safety of toys: Part 2 flammability (Third Revision) |
- |
-
|
3000 View breakup
Rs.3000/- (5% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2.2-5.2(Toys to be worn on the head-Beards, moustaches, wigs, etc. made from hair, pile, or material that behaves in a similar manner to hair (e.g. free-hanging ribbons, paper, cloth strands, or other flowing elements), which protrude 50 mm or more from the surface of the toy-Duration of the flame after the removal of the test flame) |
- |
500 |
|
5% discount for BIS |
| 4.2.2(a)-5.2(Toys to be worn on the head-Test relating to Beards, moustaches, wigs, etc. made from hair, pile, or material that behaves in a similar manner to hair (e.g. free-hanging ribbons, paper, cloth strands, or other flowing elements), which protrude 50 mm or more from the surface of the toy- if ignition occurs, the maximum burnt length of hair, pile, or material that behaves in a similar manner when the initial length was 150 mm or more) |
- |
500 |
|
5% discount for BIS |
| 4.2.2(b)-5.2(Toys to be worn on the head-Test relating to Beards, moustaches, wigs, etc. made from hair, pile, or material that behaves in a similar manner to hair (e.g. free-hanging ribbons, paper, cloth strands, or other flowing elements), which protrude 50 mm or more from the surface of the toy- if ignition occurs, the maximum burnt length of hair, pile, or material that behaves in a similar manner when the initial length was less than 150 mm) |
- |
500 |
|
5% discount for BIS |
| 4.2.3-5.3(Toys to be worn on the head-Beards, moustaches, wigs, etc. made from hair, pile, or material that behaves in a similar manner to hair (e.g. free-hanging ribbons, paper, cloth strands, or other flowing elements), which protrude less than 50 mm and more than 5 mm from the surface of the toy-Duration of the flame after the removal of the test flame) |
- |
500 |
|
5% discount for BIS |
| 4.2.4-5.3(Toys to be worn on the head-Full or partial moulded head masks-Duration of the flame after the removal of the test flame) |
- |
500 |
|
5% discount for BIS |
| 4.2.3-5.3(Toys to be worn on the head-Beards, moustaches, wigs, etc. made from hair, pile, or material that behaves in a similar manner to hair (e.g. free-hanging ribbons, paper, cloth strands, or other flowing elements), which protrude less than 50 mm and more than 5 mm from the surface of the toy- maximum distance between the upper edge of the burnt area and the point of application of the test flame) |
- |
500 |
|
5% discount for BIS |
| 4.2.4-5.3(Toys to be worn on the head-Full or partial moulded head masks-maximum distance between the upper edge of the burnt area and the point of application of the test flame) |
- |
500 |
|
5% discount for BIS |
| 4.2.5-5.4(Toys to be worn on the head-Flowing elements of toys to be worn on the head (except those covered by 4.2.2 and 4.2.3), hoods, headdresses, etc. and masks not covered by 4.2.4 which partially or fully cover the head (e.g. fabric and cardboard masks, eye masks, face masks)-rate of spread of flame) |
- |
1000 |
|
5% discount for BIS |
| 4.2.5-5.4(Toys to be worn on the head-Flowing elements of toys to be worn on the head (except those covered by 4.2.2 and 4.2.3), hoods, headdresses, etc. and masks not covered by 4.2.4 which partially or fully cover the head (e.g. fabric and cardboard masks, eye masks, face masks)-Test relating to flowing elements of toys to be worn on the head (except those covered by 4.2.2 and 4.2.3), hoods, headdresses, etc. and masks not covered by 4.2.4 which partially or fully cover the head (e.g. fabric and cardboard masks, eye masks, face masks), toy disguise costumes and toys intended to be entered or worn by a child
) |
- |
1000 |
|
5% discount for BIS |
| 4.3-5.4(Toys to be worn on the head-Toy disguise costumes and toys intended to be worn by a child in play-rate of spread of flame) |
- |
1000 |
|
5% discount for BIS |
| 4.3-5.4(Toys to be worn on the head-Toy disguise costumes and toys intended to be worn by a child in play-Test relating to flowing elements of toys to be worn on the head (except those covered by 4.2.2 and 4.2.3), hoods, headdresses, etc. and masks not covered by 4.2.4 which partially or fully cover the head (e.g. fabric and cardboard masks, eye masks, face masks), toy disguise costumes and toys intended to be entered or worn by a child) |
- |
1000 |
|
5% discount for BIS |
| 4.3(Toys to be worn on the head-Toy disguise costumes and toys intended to be worn by a child in play) |
- |
0 |
|
NIL. |
| 4.4-5.4(Toys intended to be entered by a child-rate of spread of flame) |
- |
1000 |
|
5% discount for BIS |
| 4.4-5.4(Toys intended to be entered by a child-rate of spread of flame-Test relating to flowing elements of toys to be worn on the head (except those
covered by 4.2.2 and 4.2.3), hoods, headdresses, etc. and masks not covered by 4.2.4 which partially or fully cover the head (e.g. fabric and cardboard masks, eye masks, face masks), toy disguise costumes and toys intended to be entered or worn by a child) |
- |
1000 |
|
5% discount for BIS |
| 4.4-5.4(Toys intended to be entered by a child-rate of spread of flame-Test relating to flowing elements of toys to be worn on the head (except those
covered by 4.2.2 and 4.2.3), hoods, headdresses, etc. and masks not covered by 4.2.4 which partially or fully cover the head (e.g. fabric and cardboard masks, eye masks, face masks), toy disguise costumes and toys intended to be entered or worn by a child
) |
- |
1000 |
|
5% discount for BIS |
| 4.4(Toys intended to be entered by a child-rate of spread of flame-Test relating to flowing elements of toys to be worn on the head (except those
covered by 4.2.2 and 4.2.3), hoods, headdresses, etc. and masks not covered by 4.2.4 which partially or fully cover the head (e.g. fabric and cardboard masks, eye masks, face masks), toy disguise costumes and toys intended to be entered or worn by a child
) |
- |
0 |
|
NIL. |
| 4.5-5.5(Soft-filled toys-rate of spread of flame ) |
- |
500 |
|
5% discount for BIS |
| 4.5-5.5(Soft-filled toys-Test for soft-filled toys
) |
- |
500 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 55 |
IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
- |
-
|
65000 View breakup
Rs.65000/- (5% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 20.4(General Test Requireements) |
- |
0 |
|
- |
| 20.5(Classification of Luminaires') |
- |
0 |
|
- |
| 20.6(Marking) |
- |
500 |
|
5% discount for BIS |
| 20.7(Construction) |
- |
10000 |
|
5% discount for BIS |
| 20.8(Creepage Distance and Clearances) |
- |
2500 |
|
5% discount for BIS |
| 20.9(Provision for earthing) |
- |
2500 |
|
5% discount for BIS |
| 20.10(Terminals) |
- |
2000 |
|
5% discount for BIS |
| 20.11(External & Internal Wiring) |
- |
2500 |
|
5% discount for BIS |
| 20.12(Protection against electric shock) |
- |
5000 |
|
5% discount for BIS |
| 20.13(Endurance Tests and Thermal Tests) |
- |
5000 |
|
5% discount for BIS |
| 20.14(Resistance to Dust & Moisture) |
- |
20000 |
|
5% discount for BIS |
| 20.15(Insulation Resistance and Electric Strength) |
- |
10000 |
|
5% discount for BIS |
| 20.16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 56 |
IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
- |
-
|
85000 View breakup
Rs.85000/- for Cell
Rs.75000/- for Battery
(5% discount for BIS)
Additional Rs.180000/- for Transportation test in Cell Lithium
(10% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
0 |
|
5% discount for BIS |
| 5(General Safety Considerations) |
- |
0 |
|
5% discount for BIS |
| 5.1(General) |
- |
0 |
|
5% discount for BIS |
| 5.2(Insulation and Wiring) |
- |
2000 |
|
5% discount for BIS |
| 5.3(Venting) |
- |
0 |
|
5% discount for BIS |
| 5.4(Temperature, Voltage and Current Management) |
- |
0 |
|
5% discount for BIS |
| 5.5(Terminal Contacts) |
- |
0 |
|
5% discount for BIS |
| 5.6(Assembly of Cells into batteries) |
- |
0 |
|
5% discount for BIS |
| 5.7(Quality Plan) |
- |
0 |
|
5% discount for BIS |
| 6(Tyoe Test amd Sample Size) |
- |
0 |
|
5% discount for BIS |
| 7(Specific requirements and tests) |
- |
0 |
|
5% discount for BIS |
| 7.1(Charging procedure for test purposes) |
- |
11000 |
|
5% discount for BIS |
| 7.2(Intended Use) |
- |
43500 |
|
5% discount for BIS |
| 7.3(Reasonably foreseeable misuse) |
- |
34500 |
|
5% discount for BIS |
| 8(Information for safety) |
- |
0 |
|
5% discount for BIS |
| 8.1(General) |
- |
0 |
|
5% discount for BIS |
| 8.2(Small Cell and battery safety information) |
- |
0 |
|
5% discount for BIS |
| 9(Marking) |
- |
0 |
|
5% discount for BIS |
| 9.1(Cell Marking) |
- |
0 |
|
5% discount for BIS |
| 9.2(Battery Marking) |
- |
0 |
|
5% discount for BIS |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
0 |
|
5% discount for BIS |
| 9.4(Other information) |
- |
0 |
|
5% discount for BIS |
| 10(Packaging) |
- |
0 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 57 |
IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
- |
-
|
80000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
0 |
|
- |
| 5(General Safety Considerations) |
- |
500 |
|
5% discount for BIS |
| 5.1(General) |
- |
500 |
|
- |
| 5.2(Insulation and Wiring) |
- |
1000 |
|
5% discount for BIS |
| 5.3(Venting) |
- |
500 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
500 |
|
- |
| 5.5(Terminal Contacts) |
- |
500 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
500 |
|
- |
| 5.7(Quality Plan) |
- |
500 |
|
- |
| 5.8(Battery Safety Components) |
- |
500 |
|
- |
| 6(Tyoe Test amd Sample Size) |
- |
0 |
|
- |
| 7(Specific requirements and tests) |
- |
27500 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
27500 |
|
5% discount for BIS |
| 7.2(Intended Use) |
- |
8000 |
|
5% discount for BIS |
| 7.3(Reasonably foreseeable misuse) |
- |
38000 |
|
5% discount for BIS |
| 8(Information for safety) |
- |
1000 |
|
5% discount for BIS |
| 8.1(General) |
- |
1000 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
1000 |
|
- |
| 9(Marking) |
- |
500 |
|
5% discount for BIS |
| 9.1(Cell Marking) |
- |
500 |
|
- |
| 9.2(Battery Marking) |
- |
500 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
500 |
|
- |
| 9.4(Other information) |
- |
500 |
|
- |
| 10(Packaging) |
- |
500 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 58 |
IS 14286 : Part 1 : Sec 1 (2019) |
Terrestrial photovoltaic (PV) modules - Design qualification and type approval: Part 1 test requirements: Sec 1 special requirements for testing of crystalline silicon photovoltaic (Pv) modules (Second Revision) |
Terrestrial Photovoltaic (PV) Modules |
-
|
750000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11.1(Visual inspection (MQT 01)) |
- |
7500 |
|
- |
| 11.2(Maximum power determination (MQT 02)) |
- |
7500 |
|
- |
| 11.3(Insulation test (MQT 03)) |
- |
15000 |
|
- |
| 11.4(Measurement of temperature coefficients (MQT 04)) |
- |
55000 |
|
- |
| 11.5(Measurement of nominal module operating temperature (NMOT)
(MQT 05)) |
- |
55000 |
|
- |
| 11.6(Performance at STC and NMOT
(MQT 06)) |
- |
60000 |
|
- |
| 11.7(Performance at low irradiance
(MQT 07)) |
- |
57500 |
|
- |
| 11.8(Outdoor exposure test (MQT 08)) |
- |
32500 |
|
- |
| 11.9(Hot-spot endurance test (MQT 09)) |
- |
80000 |
|
- |
| 11.1(UV preconditioning test
(MQT 10)) |
- |
37500 |
|
- |
| 11.11(Thermal cycling test (MQT 11)) |
- |
50000 |
|
- |
| 11.12(Humidity-freeze test (MQT 12)) |
- |
57500 |
|
- |
| 11.13(Damp heat test (MQT 13)) |
- |
42500 |
|
- |
| 11.14(Robustness of terminations
(MQT 14)) |
- |
20000 |
|
- |
| 11.15(Wet leakage current test (MQT 15)) |
- |
25000 |
|
- |
| 11.16(Static mechanical load test
(MQT 16)) |
- |
25000 |
|
- |
| 11.17(Hail test (MQT 17)) |
- |
52500 |
|
- |
| 11.18(Bypass diode thermal test (MQT 18)) |
- |
27500 |
|
- |
| 11.19(Stabilization (MQT 19)) |
- |
42500 |
|
- |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 59 |
IS 14286 : Part 1 : Sec 2 (2019) |
Terrestrial photovoltaic (PV) modules - Design qualification and type approval: Part 1 test requirements: Sec 2 special requirements for testing of thin - Film cadmium telluride (CdTe) based photovoltaic (Pv) modules (Second Revision) |
Terrestrial Photovoltaic (PV) Modules |
-
|
750000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11.19(Stabilization (MQT 19)) |
- |
42500 |
|
- |
| 11.18(Bypass diode thermal test (MQT 18)) |
- |
27500 |
|
- |
| 11.19
IS 14286( Stabilization ) |
- |
42500 |
|
- |
| 11.18
IS 14286( Bypass diode testing) |
- |
27500 |
|
- |
| 11.17, Table 3 & 4,
IS 14286( Hail test) |
- |
52500 |
|
- |
| 11.16
IS 14286( Static Mechanical load test) |
- |
25000 |
|
- |
| 11.15
IS 14286( Wet leakage current test) |
- |
25000 |
|
- |
| 11.14, Table 1
IS 14286( Robutness of terminations test - Retention of Junction Box on Mounting Surface - Test of Cord Anchorage) |
- |
20000 |
|
- |
| 11.13
IS 14286(Damp heat test) |
- |
42500 |
|
- |
| 11.12
IS 14286( Humidity-freeze test) |
- |
57500 |
|
- |
| 11.11
IS 14286( Thermal cycling test) |
- |
50000 |
|
- |
| 11.10
IS 14286( UV Preconditioning test ) |
- |
37500 |
|
- |
| 11.9
IS 14286( Hot-spot endurance test) |
- |
80000 |
|
- |
| 11.8
IS 14286( Outdoor exposure Test) |
- |
32500 |
|
- |
| 11.7
IS 14286( Performance at low irradiance) |
- |
57500 |
|
- |
| 11.6
IS 14286( Performance at STC and NMOT) |
- |
60000 |
|
- |
| 11.5
IS 14286( Measurement of nominal module operating temperature (NMOT)) |
- |
55000 |
|
- |
| 11.4
IS 14286( Measurement of temperature coefficients) |
- |
55000 |
|
- |
| 11.3
IS 14286( Insulation Test) |
- |
15000 |
|
- |
| 11.2
IS 14286( Maximum power determination) |
- |
7500 |
|
- |
| 11.1
IS 14286( Visual inspection) |
- |
7500 |
|
- |
| 5
IS 14286( Marking and Documentation) |
- |
0 |
|
- |
|
Complete
|
|
19 Mar, 2023 |
- - |
| 60 |
IS 14286 : Part 1 : Sec 3 (2019) |
Terrestrial photovoltaic (PV) modules - Design qualification and type approval: Part 1 test requirements: Sec 3 special requirements for testing of thin - Film amorphous silicon based photovoltaic (Pv) modules (Second Revision) |
- |
-
|
750000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5
IS 14286( Marking and Documentation) |
- |
0 |
|
- |
| 11.1
IS 14286( Visual inspection) |
- |
7500 |
|
- |
| 11.2
IS 14286( Maximum power determination) |
- |
7500 |
|
- |
| 11.3
IS 14286( Insulation Test) |
- |
15000 |
|
- |
| 11.4
IS 14286( Measurement of temperature coefficients) |
- |
55000 |
|
- |
| 11.5
IS 14286( Measurement of nominal module operating temperature (NMOT)) |
- |
55000 |
|
- |
| 11.6
IS 14286( Performance at STC and NMOT) |
- |
60000 |
|
- |
| 11.7
IS 14286( Performance at low irradiance) |
- |
57500 |
|
- |
| 11.8
IS 14286( Outdoor exposure Test) |
- |
32500 |
|
- |
| 11.9
IS 14286( Hot-spot endurance test) |
- |
80000 |
|
- |
| 11.10
IS 14286( UV Preconditioning test ) |
- |
37500 |
|
- |
| 11.11
IS 14286( Thermal cycling test) |
- |
50000 |
|
- |
| 11.12
IS 14286( Humidity-freeze test) |
- |
57500 |
|
- |
| 11.13
IS 14286(Damp heat test) |
- |
42500 |
|
- |
| 11.14, Table 1
IS 14286( Robutness of terminations test - Retention of Junction Box on Mounting Surface - Test of Cord Anchorage) |
- |
20000 |
|
- |
| 11.15
IS 14286( Wet leakage current test) |
- |
25000 |
|
- |
| 11.16(Static mechanical load test
(MQT 16)) |
- |
25000 |
|
- |
| 11.17, Table 3 & 4,
IS 14286( Hail test) |
- |
52500 |
|
- |
| 11.18
IS 14286( Bypass diode testing) |
- |
27500 |
|
- |
| 11.19
IS 14286( Stabilization ) |
- |
42500 |
|
- |
|
Complete
|
|
19 Mar, 2023 |
- - |