| 31 |
IS 303 (1989) |
Plywood for General Purposes - |
- |
-
|
7000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8(Dimensions & Tolerances - Length - Cl. 8) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 8(Dimensions & Tolerances - Width - Cl. 8) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 8(Dimensions & Tolerances - Thickness - Cl. 8) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 8(Dimensions & Tolerances - Squareness - Annexure C) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 8(Dimensions & Tolerances - Edge Straightness - Annexure C) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.2.1(Glue Adhesion - Water resistance test - 11.2.1.1 [for BWR Grade]) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.2.1(Glue Adhesion - Water resistance test - 11.2.1.1 [for MR Grade]) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.2.2(Glue Adhesion - Mycological test - 11.2.2, Part 7 of IS 1734 [for MR Garde only]) |
- |
2000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.3(Moisture Content - Part 1 of IS 1734) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.2, Table 1, Table 2(Quality Requirements - Cl. 5.2) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.4, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.4, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.4, Table 4(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Average) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.4, Table 4(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Minimum Individual) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.4, Table 4(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Average) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.4, Table 4(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Minimum Individual) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.4, Table 4(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Average) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.4, Table 4(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Minimum Individual) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 32 |
IS 456 (2000) |
Plain and reinforced concrete - Code of practice (Fourth Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
17 Jun, 2024 |
- - |
| 33 |
IS 1165 (2002) |
Milk powder - Specification (First Revision) |
- |
-
|
- View breakup
Rs.7500.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
17 Jun, 2024 |
- - |
| 34 |
IS 4159 (2002) |
Mineral filled sheathed heating elements - Specification (Third Revision) |
- |
-
|
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 4159:2002 &
IS 302-1:2008
(Classification) |
- |
200 |
|
NA |
| Cl.6 of IS 4159:2002 &
IS 302-1:2008
(Classification) |
- |
200 |
|
NA |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
50 |
|
NA |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
50 |
|
NA |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
50 |
|
NA |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
50 |
|
NA |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
50 |
|
NA |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
50 |
|
NA |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
50 |
|
NA |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
50 |
|
NA |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
50 |
|
NA |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
50 |
|
NA |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
50 |
|
NA |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
50 |
|
NA |
| Cl.8 of IS 4159:2002 & IS 302‐1:2008(Protection Against Electric Shock) |
- |
300 |
|
NA |
| Cl.10 of IS 4159:2002 &
IS 302-1:2008(Input & Current) |
- |
500 |
|
NA |
| Cl.11 of IS 4159:2002 & IS 302‐1:2008(Temperature Rise) |
- |
500 |
|
NA |
| Cl.11 of IS 4159:2002 & IS 302‐1:2008(Temperature Rise) |
- |
500 |
|
NA |
| Cl.13 of IS 4159:2002 & IS 302-1: 2008(Electrical Insulation and Leakage Current at Operating Temperature) |
- |
300 |
|
NA |
| Cl.13 of IS 4159:2002 & IS 302-1: 2008(Electrical Insulation and Leakage Current at Operating Temperature) |
- |
300 |
|
NA |
| Cl.15 of IS 4159:2002 & IS 302-1: 2008(Moisture Resistance) |
- |
500 |
|
NA |
| Cl.15 of IS 4159:2002 & IS 302-1: 2008(Moisture Resistance) |
- |
500 |
|
NA |
| Cl.16 of IS 4159:2002 & IS 302-1: 2008(Insulation Resistance & Electric Strength (after Humidity Treatment)) |
- |
800 |
|
NA |
| Cl.16 of IS 4159:2002 & IS 302-1: 2008(Insulation Resistance & Electric Strength (after Humidity Treatment)) |
- |
800 |
|
NA |
| Cl.18 of IS 4159:2002(Endurance Test
) |
- |
1500 |
|
NA |
| Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
100 |
|
NA |
| Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
100 |
|
NA |
| Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
100 |
|
NA |
| Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
100 |
|
NA |
| Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
100 |
|
NA |
| Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
100 |
|
NA |
| Cl.20 of IS 4159:2002 & IS 302-1: 2008(Stability & Mechanical Hazards
) |
- |
500 |
|
NA |
| Cl.21 of IS 4159:2002 & IS 302-1: 2008(Mechanical Strength) |
- |
500 |
|
NA |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
200 |
|
NA |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
200 |
|
NA |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
200 |
|
NA |
| Cl.23 of IS 4159:2002 &
IS 302-1: 2008(Internal Wiring
) |
- |
300 |
|
NA |
| Cl.24 of IS 4159:2002 &
IS 302-1: 2008(Component ) |
- |
200 |
|
NA |
| Cl.25 of IS 4159:2002 & IS 302-1: 2008(Supply connection & external flexible cables & cords) |
- |
500 |
|
NA |
| Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
300 |
|
NA |
| Cl.27 of IS 4159:2002 & IS 302-1: 2008(Provision for Earthing) |
- |
500 |
|
NA |
| Cl.27 of IS 4159:2002 & IS 302-1: 2008(Provision for Earthing) |
- |
500 |
|
NA |
| Cl.28 of IS 4159:2002 & IS 302-1: 2008(Screws & Connection ) |
- |
100 |
|
NA |
| Cl.28 of IS 4159:2002 & IS 302-1: 2008(Screws & Connection ) |
- |
100 |
|
NA |
| Cl.28 of IS 4159:2002 & IS 302-1: 2008(Screws & Connection ) |
- |
100 |
|
NA |
| Cl. 29 of IS 4159:2002 &
IS 302-1: 2008(Creepage Distances & Clearances) |
- |
200 |
|
NA |
| Cl. 29 of IS 4159:2002 &
IS 302-1: 2008(Creepage Distances & Clearances) |
- |
200 |
|
NA |
| Cl. 30 of IS 4159:2002 &
IS 302-1: 2008(Resistance to Heat, Fire and Tracking) |
- |
500 |
|
NA |
| Cl. 30 of IS 4159:2002 &
IS 302-1: 2008(Resistance to Heat, Fire and Tracking) |
- |
500 |
|
NA |
| Cl. 31 of IS 4159:2002 &
IS 302-1: 2008(Resistance to Rusting) |
- |
500 |
|
NA |
| Cl. 33.1 of IS 4159:2002(Finish Test
) |
- |
300 |
|
NA |
| 5(Ratings) |
- |
300 |
|
NA |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 35 |
IS 4989 : Part 4 (2003) |
Multipurpose aqueous film forming foam liquid concentrate for extinguishing hydrocarbon and polar solvent fires - Specification |
- |
-
|
- View breakup
Rs.31700/- (Provisional testing charges)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
17 Jun, 2024 |
- - |
| 36 |
IS 15410 (2003) |
Containers for packaging of natural mineral water and packaged drinking water - Specification |
- |
-
|
- View breakup
Rs.5800.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
17 Jun, 2024 |
- - |
| 37 |
IS 1258 (2005) |
Bayonet lamp holders (Fourth Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
17 Jun, 2024 |
- - |
| 38 |
IS 3087 (2005) |
Practicle boards of wood and other lingnocellulosic materials (medium density) for general purposes -Specification |
- |
-
|
10000 View breakup
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.15,000/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1 (i) Table 1(Density Variation (Flat Pressed Single Layer)) |
- |
750 |
|
NA |
| 1 (i) Table 1(Density Variation (Flat Pressed Three Layer grade 1)) |
- |
750 |
|
NA |
| 1 (i) Table 1(Density Variation (Flat Pressed Three Layer grade 2)) |
- |
750 |
|
NA |
| 1 (i) Table 1(Density Variation (Extrusion Pressed Solids) XPS) |
- |
750 |
|
NA |
| 1 (i) Table 1(Density Variation (Extrusion Pressed Tubular) XPS) |
- |
750 |
|
NA |
| 1 (ii) (a) Table 1(Water absorption, 2h soacking (Flat Pressed Single Layer)) |
- |
1000 |
|
NA |
| 1 (ii) (a) Table 1(Water absorption, 2h soacking (Flat Pressed Three Layer grade 1)) |
- |
1000 |
|
NA |
| 1 (ii) (a) Table 1(Water absorption, 2h soacking (Flat Pressed Three Layer grade 2)) |
- |
1000 |
|
NA |
| 1 (ii) (a) Table 1(Water absorption, 2h soacking (Extrusion Pressed Solids) XPS) |
- |
1000 |
|
NA |
| 1 (ii) (a) Table 1(Water absorption, 2h soacking (Extrusion Pressed Tubular) XPS) |
- |
1000 |
|
NA |
| 1 (ii) Table 1 (b)(Water absorption, 24h soacking (Flat Pressed Single Layer)) |
- |
1000 |
|
NA |
| 1 (ii) (b) Table 1 (Water absorption, 24h soacking (Flat Pressed Three Layer grade 1)) |
- |
1000 |
|
NA |
| 1 (ii) (b) Table 1 (Water absorption, 24h soacking (Flat Pressed Three Layer grade 2)) |
- |
1000 |
|
NA |
| 1 (ii) (b) Table 1 (Water absorption, 24h soacking (Extrusion Pressed Solids) XPS) |
- |
1000 |
|
NA |
| 1 (ii) (b) Table 1 (Water absorption, 24h soacking (Extrusion Pressed Tubular) XPS) |
- |
1000 |
|
NA |
| 1 (iii) (a) Table 1(Linear expression (swelling in water), Length (Flat Pressed Single Layer)) |
- |
750 |
|
NA |
| 1 (iii) (a) Table 1(Linear expression (swelling in water), Length (Flat Pressed Three Layer grade 1)) |
- |
750 |
|
NA |
| 1 (iii) (a) Table 1(Linear expression (swelling in water), Length (Flat Pressed Three Layer grade 2)) |
- |
750 |
|
NA |
| 1 (iii) (a) Table 1(Linear expression (swelling in water), Length (Extrusion Pressed Solids) XPS) |
- |
750 |
|
NA |
| 1 (iii) (a) Table 1(Linear expression (swelling in water), Length (Extrusion Pressed Tubular) XPS) |
- |
750 |
|
NA |
| 1 (iii) (b) Table 1(Linear expression (swelling in water), Width (Flat Pressed Single Layer)) |
- |
750 |
|
NA |
| 1 (iii) (b) Table 1(Linear expression (swelling in water), Width (Flat Pressed Three Layer grade 1)) |
- |
750 |
|
NA |
| 1 (iii) (b) Table 1(Linear expression (swelling in water), Width (Flat Pressed Three Layer grade 2)) |
- |
750 |
|
NA |
| 1 (iii) (b) Table 1(Linear expression (swelling in water), Width (Extrusion Pressed Solids) XPS) |
- |
750 |
|
NA |
| 1 (iii) (b) Table 1(Linear expression (swelling in water), Width (Extrusion Pressed Tubular) XPS) |
- |
750 |
|
NA |
| 1 (iv) Table 1(Thickness swelling, Width (Flat Pressed Single Layer)) |
- |
750 |
|
NA |
| 1 (iv) Table 1(Thickness swelling, Width (Flat Pressed Three Layer grade 1)) |
- |
750 |
|
NA |
| 1 (iv) Table 1(Thickness swelling, Width (Flat Pressed Three Layer grade 2)) |
- |
750 |
|
NA |
| 1 (iv) Table 1(Thickness swelling, Width (Extrusion Pressed Solids) XPS) |
- |
750 |
|
NA |
| 1 (iv) Table 1(Thickness swelling, Width (Extrusion Pressed Tubular) XPS) |
- |
750 |
|
NA |
| 1 (v) Table 1(Swelling in thickness due to surface absorption, (Flat Pressed Single Layer)) |
- |
750 |
|
NA |
| 1 (v) Table 1(Swelling in thickness due to surface absorption, (Flat Pressed Three Layer grade 1)) |
- |
750 |
|
NA |
| 1 (v) Table 1(Swelling in thickness due to surface absorption, (Flat Pressed Three Layer grade 2)) |
- |
750 |
|
NA |
| 1 (v) Table 1(Swelling in thickness due to surface absorption, (Extrusion Pressed Solids) XPS) |
- |
750 |
|
NA |
| 1 (v) Table 1(Swelling in thickness due to surface absorption, (Extrusion Pressed Tubular) XPS) |
- |
750 |
|
NA |
| 1 (vi) (a), Table 1(Modulus of rupture, Average (Flat Pressed Single Layer)) |
- |
750 |
|
NA |
| 1 (vi) (a), Table 1(Modulus of rupture, Average (Flat Pressed Three Layer grade 1)) |
- |
750 |
|
NA |
| 1 (vi) (a), Table 1(Modulus of rupture, Average (Flat Pressed Three Layer grade 2)) |
- |
750 |
|
NA |
| 1 (vi) (a), Table 1(Modulus of rupture, Average (Extrusion Pressed Solids) XPS) |
- |
750 |
|
NA |
| 1 (vi) (a), Table 1(Modulus of rupture, Average (Extrusion Pressed Tubular) XPS) |
- |
750 |
|
NA |
| 1 (vi) (b), Table 1(Modulus of rupture, Minimum (Flat Pressed Single Layer)) |
- |
750 |
|
NA |
| 1 (vi) (b), Table 1(Modulus of rupture, Minimum (Flat Pressed Three Layer grade 1)) |
- |
750 |
|
NA |
| 1 (vi) (b), Table 1(Modulus of rupture, Minimum (Flat Pressed Three Layer grade 2)) |
- |
750 |
|
NA |
| 1 (vi) (b), Table 1(Modulus of rupture, Minimum (Extrusion Pressed Solids) XPS) |
- |
750 |
|
NA |
| 1 (vi) (b), Table 1(Modulus of rupture, Minimum (Extrusion Pressed Tubular) XPT) |
- |
750 |
|
NA |
| 1 (vii) (a), Table 1(Modulus of elasticity, Average (Flat Pressed Single Layer)) |
- |
750 |
|
NA |
| 1 (vii) (a), Table 1(Modulus of elasticity, Average (Flat Pressed Three Layer grade 1)) |
- |
750 |
|
NANA |
| 1 (vii) (a), Table 1(Modulus of elasticity, Average (Flat Pressed Three Layer grade 2)) |
- |
750 |
|
NA |
| 1 (vii) (a), Table 1(Modulus of elasticity, Average (Extrusion Pressed Solids) XPS) |
- |
750 |
|
NA |
| 1 (vii) (a), Table 1(Modulus of elasticity, Average (Extrusion Pressed Tubular) XPT) |
- |
750 |
|
NA |
| 1 (vii) (b), Table 1(Modulus of elasticity, Minimum (Flat Pressed Single Layer)) |
- |
750 |
|
NA |
| 1 (vii) (b), Table 1(Modulus of elasticity, Minimum (Flat Pressed Three Layer grade 1)) |
- |
750 |
|
NA |
| 1 (vii) (b), Table 1(Modulus of elasticity, Minimum (Flat Pressed Three Layer grade 2)) |
- |
750 |
|
NA |
| 1 (vii) (b), Table 1(Modulus of elasticity, Minimum (Extrusion Pressed Solids) XPS) |
- |
750 |
|
NA |
| 1 (vii) (b), Table 1(Modulus of elasticity, Minimum (Extrusion Pressed Tubular) XPT) |
- |
750 |
|
NA |
| 1 (viii) (a), Table 1(Tensile strenath perpendicullr to surface, Upto 20mm thickness (Flat Pressed Single Layer)) |
- |
1500 |
|
NA |
| 1 (viii) (a), Table 1(Tensile strenath perpendicullr to surface,Upto 20mm thickness (Flat Pressed Three Layer grade 1)) |
- |
1500 |
|
NA |
| 1 (viii) (a), Table 1(Tensile strenath perpendicullr to surface, Upto 20mm thickness (Flat Pressed Three Layer grade 2)) |
- |
1500 |
|
NA |
| 1 (viii) (a), Table 1(Tensile strenath perpendicullr to surface, Upto 20mm thickness (Extrusion Pressed Solids) XPS) |
- |
1500 |
|
NA |
| 1 (viii) (b), Table 1(Tensile strenath perpendicullr to surface, Above 20mm thickness (Flat Pressed Single Layer)) |
- |
1500 |
|
NA |
| 1 (viii) (b), Table 1(Tensile strenath perpendicullr to surface,Above 20mm thickness (Flat Pressed Three Layer grade 1)) |
- |
1500 |
|
NA |
| 1 (viii) (b), Table 1(Tensile strenath perpendicullr to surface, Above 20mm thickness (Flat Pressed Three Layer grade 2)) |
- |
1500 |
|
NA |
| 1 (viii) (b), Table 1(Tensile strenath perpendicullr to surface, Above 20mm thickness (Extrusion Pressed Solids) XPS) |
- |
1500 |
|
NA |
| 1 (viii) (b), Table 1(Tensile strenath perpendicullr to surface, Above 20mm thickness (Extrusion Pressed Tubular) XPT) |
- |
1500 |
|
NA |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 39 |
IS 13428 (2005) |
Packaged natural mineral water specification (Second Revision) |
- |
-
|
16500 View breakup
Rs.16500.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1.1(Escherichia coli(or thermotolerant bacteria)) |
- |
450 |
|
N.A. |
| 6.1.2(Coliform , bacteria) |
- |
450 |
|
N.A. |
| 6.1.3(Faecal Streptococci ) |
- |
450 |
|
N.A. |
| 6.1.3(Staphylococcus Aureus) |
- |
450 |
|
N.A. |
| 6.1.4(Sulphite Reducing Anaerobes ) |
- |
450 |
|
N.A. |
| 6.1.5(Pseudomonas Aeruginosa ) |
- |
500 |
|
N.A. |
| 6.1.6(Yeast and Mould ) |
- |
450 |
|
N.A. |
| 6.1.7(Salmonella ) |
- |
500 |
|
N.A. |
| 6.1.7(Shigella) |
- |
500 |
|
N.A. |
| 6.1.8(Vibrio cholera ) |
- |
450 |
|
N.A. |
| 6.1.8(Vibrio parahemolyticus) |
- |
450 |
|
N.A. |
| 6.2 Table-1 i(Colour) |
- |
200 |
|
N.A. |
| 6.2 Table-1 ii(Odour) |
- |
100 |
|
N.A. |
| 6.2 Table-1 iii(Taste) |
- |
100 |
|
N.A. |
| 6.2 Table-1 iv(Turbidity) |
- |
200 |
|
N.A. |
| 6.2 Table-1 v(Total dissolved solids) |
- |
200 |
|
N.A. |
| 6.2 Table-1 vi(pH) |
- |
100 |
|
N.A. |
| 6.2 Table-2 i(Nitrate (as NO3)) |
- |
200 |
|
N.A. |
| 6.2 Table-2 ii(Nitrite (as NO2)) |
- |
200 |
|
N.A. |
| 6.2 Table-2 iii(Sulphide (as H2S)) |
- |
200 |
|
N.A. |
| 6.2 Table-2 iv(Manganese (as Mn)) |
- |
200 |
|
N.A. |
| 6.2 Table-2 v(Copper (as Cu)) |
- |
200 |
|
N.A. |
| 6.2 Table-2 vi(Zinc (as Zn)) |
- |
200 |
|
N.A. |
| 6.2 Table-2 vii(Flouride (as F)) |
- |
200 |
|
N.A. |
| 6.2 Table-2 viii(Barium (as Ba)) |
- |
20 |
|
N.A. |
| 6.2 Table-2 ix(Antimony (as Sb)) |
- |
200 |
|
N.A. |
| 6.2 Table-2 x(Borates (as B)) |
- |
200 |
|
N.A. |
| 6.2 Table-2 xi(Silver (as Ag)) |
- |
200 |
|
N.A. |
| 6.2 Table-2 xii(Chloride (as Cl)) |
- |
200 |
|
N.A. |
| 6.2 Table-2 xiii(Sulphate (as SO4),) |
- |
200 |
|
N.A. |
| 6.2 Table-2 xiv(Magnesium (as Mg)) |
- |
200 |
|
N.A. |
| 6.2 Table-2 xv(Calcium (as Ca)) |
- |
200 |
|
N.A. |
| 6.2 Table-2 xvi(Sodium (as Na)) |
- |
200 |
|
N.A. |
| 6.2 Table-2 xvii(Alkalinity (as HCO3)) |
- |
200 |
|
N.A. |
| 6.2 Table-2 xviii(Selenium (as Se)) |
- |
200 |
|
N.A. |
| 6.2 Table-2 xix(Mineral Oil) |
- |
500 |
|
N.A. |
| 6.2 Table-2 xx(Phenolic compounds (as C6H5OH)) |
- |
300 |
|
N.A. |
| 6.2 Table-2 xxi(Anionic surface active agents (as MBAS)) |
- |
300 |
|
N.A. |
| 6.2 Table-3 i(Arsenic (as As)) |
- |
200 |
|
N.A. |
| 6.2 Table-3 ii(Cadmium (as Cd)) |
- |
200 |
|
N.A. |
| 6.2 Table-3 iii(Cyanide (as CN)) |
- |
200 |
|
N.A. |
| 6.2 Table-3 iv(Chromium (as Cr)) |
- |
200 |
|
N.A. |
| 6.2 Table-3 v(Mercury (as Hg)) |
- |
200 |
|
N.A. |
| 6.2 Table-3 vi(Lead (as Pb) |
- |
200 |
|
N.A. |
| 6.2 Table-3 vii(Nickel (as Ni)) |
- |
200 |
|
N.A. |
| 6.2 Table-3 viii(Polychlorinated biphenyle (PCB)) |
- |
500 |
|
N.A. |
| 6.2 Table-3 ix(Polynuclear aromatic hydrocarbons) |
- |
500 |
|
N.A. |
| 6.3(o,p DDT) |
- |
100 |
|
N.A. |
| 6.3(p,p DDT) |
- |
100 |
|
N.A. |
| 6.3(o,p DDE) |
- |
100 |
|
N.A. |
| 6.3(p, DDE) |
- |
100 |
|
N.A. |
| 6.3(o,p DDD) |
- |
100 |
|
N.A. |
| 6.3(p,p DDD) |
- |
100 |
|
N.A. |
| 6.3(γ-HCH (Lindane)) |
- |
100 |
|
N.A. |
| 6.3(α-HCH) |
- |
100 |
|
N.A. |
| 6.3(β-HCH) |
- |
100 |
|
N.A. |
| 6.3(δ-HCH) |
- |
100 |
|
N.A. |
| 6.3(α Endosulfan) |
- |
100 |
|
N.A. |
| 6.3(β Endosulfan) |
- |
100 |
|
N.A. |
| 6.3(Endosulfan Sulphate) |
- |
100 |
|
N.A. |
| 6.3(Monocrotophos) |
- |
100 |
|
N.A. |
| 6.3(Ethion) |
- |
100 |
|
N.A. |
| 6.3(Chlorpyrifos) |
- |
100 |
|
N.A. |
| 6.3(Phorate) |
- |
100 |
|
N.A. |
| 6.3(Phorate sulphoxide) |
- |
100 |
|
N.A. |
| 6.3(phorate sulphone) |
- |
100 |
|
N.A. |
| 6.3(2,4-D) |
- |
100 |
|
N.A. |
| 6.3(Butachlor) |
- |
100 |
|
N.A. |
| 6.3(Isoproturon) |
- |
100 |
|
N.A. |
| 6.3(Alachlor) |
- |
100 |
|
N.A. |
| 6.3(Atrazine) |
- |
100 |
|
N.A. |
| 6.3(Methyl Parathion) |
- |
100 |
|
N.A. |
| 6.3(Methyl Paraoxon) |
- |
100 |
|
N.A. |
| 6.3(Malathion) |
- |
100 |
|
N.A. |
| 6.3(Malaoxon) |
- |
100 |
|
N.A. |
| 6.3(Aldrin) |
- |
100 |
|
N.A. |
| 6.3(Dieldrin) |
- |
500 |
|
N.A. |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 40 |
IS 15609 (2005) |
Polyethylene flexible pouches for the packing of natural mineral water and packaged drinking water - Specification |
- |
-
|
- View breakup
Rs.6250.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
17 Jun, 2024 |
- - |
| 41 |
IS 3601 (2006) |
Steel tubes for mechanical and general engineering purposes - Specification (Second Revision) |
- |
-
|
9500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Material) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 4.1(Sulphur-Percentage by mass) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 4.1(Phosphorus-Percentage by mass) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 6.0(Workmanship) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 8.0(Straightness) |
- |
600 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.2(Surface Protection) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 13.1.1(Yield Stress) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 13.1.2(Elongation) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 13.1.3(Tensile Strength) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 13.2(Flattening Test) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 13.3(Bend Test (Strip)) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 13.4(Bend Test (Whole Tube)) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 13.5(Drift Expansion Test) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 13.6(Crush Test) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 19.1.3(Height of Internal Fin) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 19.1.1, 24.1.1, 28.1.1, 33.1.1(Dimensions- Outside Dia) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 19.1.2, 24.1.2, 28.1.2, 33.1.2(Dimensions- Thickness) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 42 |
IS 8963 (2006) |
Chlorpyrifos, technical - (First Revision) specification |
- |
-
|
2400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2 Table 1(Water content) |
- |
400 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 3.2 Table 1(Acidity) |
- |
400 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 3.2 Table 1(Material insoluble in acetone) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 3.2 Table 1(Chlorpyrifos content) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 3.1(Description ) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 43 |
IS 15644 (2006) |
Safety of electric toys |
- |
-
|
26000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.0(Marking and instructions) |
- |
500 |
|
- |
| 8.0(Power Input) |
- |
500 |
|
- |
| 9.0(Heating and abnormal operation) |
- |
1000 |
|
- |
| 10.0(Electrical strength at operating temperature) |
- |
1500 |
|
- |
| 11.1(Moisture resistance) |
- |
2000 |
|
- |
| 11.2(Resistant to humidity) |
- |
1500 |
|
- |
| 12.0(Electric strength at room temperature) |
- |
1000 |
|
- |
| 13.0(Mechanical strength) |
- |
500 |
|
- |
| 14.1(Construction) |
- |
50 |
|
- |
| 14.2(Construction) |
- |
50 |
|
- |
| 14.3(Construction) |
- |
50 |
|
- |
| 14.4(Construction) |
- |
50 |
|
- |
| 14.5(Construction) |
- |
50 |
|
- |
| 14.6(Construction) |
- |
50 |
|
- |
| 14.7(Construction) |
- |
100 |
|
- |
| 14.8(Construction) |
- |
100 |
|
- |
| 14.9(Construction) |
- |
100 |
|
- |
| 14.1(Construction) |
- |
250 |
|
- |
| 14.11(Construction) |
- |
50 |
|
- |
| 14.12(Construction) |
- |
50 |
|
- |
| 14.13(Construction) |
- |
50 |
|
- |
| 14.14(Construction) |
- |
50 |
|
- |
| 15.1(Protection of cords and wires) |
- |
250 |
|
- |
| 15.2(Protection of cords and wires) |
- |
250 |
|
- |
| 16.0(Components) |
- |
500 |
|
- |
| 17 Table-1(Screws and connections) |
- |
250 |
|
- |
| 17 Table-1(Nominal daimeter of screws made of insulating material) |
- |
250 |
|
- |
| 18.0(Clearance and creepage distance) |
- |
500 |
|
- |
| 19.1(Ball pressure test IEC 60695-10-2) |
- |
500 |
|
- |
| 19.2.1(Glow wire test IEC 60695-2-11) |
- |
750 |
|
- |
| 19.2.2(Needle flame test) |
- |
1000 |
|
- |
| 20.0(Radiation, toxicity and similar hazards) |
- |
500 |
|
- |
| 9873 (Part-9) 3(Vinyl in any part of the toy or childcare article that can be placed in mouth of a child under 4 years of age - a) Di-iso-Nonyl Phthalate (DINP), b) Di-iso-Decyl Phthalate (DIDP), c) Di-n-Octyl Phthalate (DNOP) - IS 9873 Part 6) |
- |
2000 |
|
- |
| 9873 (Part-9) 3(Vinyl in toys or childcare articles - a) Bis-(2-ethlyhexyl) Phthalates (DEHP), b) Di-Butyl phthalate (DBP), c) Benzyl butyl Phthalate (BBP) - IS 9873 Part 6) |
- |
2000 |
|
- |
| 9873 (Part-9) 3(Vinyl in any part of the toy or childcare article that can be placed in mouth of a child under 4 years of age - a) Di-iso-Nonyl Phthalate (DINP), b) Di-iso-Decyl Phthalate (DIDP), c) Di-n-Octyl Phthalate (DNOP) - IS 9873 Part 6) |
- |
2000 |
|
- |
| 9873 (Part-9) 3(Vinyl in toys or childcare articles - a) Bis-(2-ethlyhexyl) Phthalates (DEHP), b) Di-Butyl phthalate (DBP), c) Benzyl butyl Phthalate (BBP) - IS 9873 Part 6) |
- |
2000 |
|
- |
| 9873 (Part-3) 4.1 - Table 1(Antimony (Sb) - Cl 7,8,9) |
- |
625 |
|
- |
| 9873 (Part-3) 4.1 - Table 1(Arsenic (As) - Cl 7,8,9 ) |
- |
625 |
|
- |
| 9873 (Part-3) 4.1 - Table 1(Barium (Ba) - Cl 7,8,9 ) |
- |
625 |
|
- |
| 9873 (Part-3) 4.1 - Table 1(Cadmium (Cd) - Cl 7,8,9) |
- |
625 |
|
- |
| 9873 (Part-3) 4.1 - Table 1(Chromium (Cr) - Cl 7,8,9 ) |
- |
625 |
|
- |
| 9873 (Part-3) 4.1 - Table 1(Lead (Pb) - Cl 7,8,9 ) |
- |
625 |
|
- |
| 9873 (Part-3) 4.1 - Table 1(Mercury (Hg) - Cl 7,8,9 ) |
- |
625 |
|
- |
| 9873 (Part-3) 4.1 - Table 1(Selenium (Se) - Cl 7,8,9 ) |
- |
625 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 44 |
IS 302 : Part 2 : Sec 3 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 3 electric iron (First Revision) |
- |
-
|
- View breakup
Rs.10000.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
17 Jun, 2024 |
- Except Cl.24 cycle test for components |
| 45 |
IS 1656 (2007) |
Milk - Cereal based complementary foods - Specification (Fourth Revision) |
- |
-
|
- View breakup
Rs.16350/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
17 Jun, 2024 |
- - |
| 46 |
IS 11536 (2007) |
Processed - Cereal based complementary foods - Specification (Second Revision) |
- |
-
|
- View breakup
Rs.16250.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
17 Jun, 2024 |
- - |
| 47 |
IS 14433 (2007) |
Infant milk substitutes - Specification (First Revision) |
- |
-
|
21100 View breakup
Rs.21100.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Description) |
- |
250 |
|
N.A. |
| 6.3(Flavour taste and odour) |
- |
250 |
|
N.A. |
| 6.4(Scorched particles) |
- |
250 |
|
N.A. |
| 6.5(Linoleate) |
- |
250 |
|
N.A. |
| 6.5(Vitamin E (for type 2 only)) |
- |
750 |
|
N.A. |
| 6.9.1(Bacterial count) |
- |
500 |
|
N.A. |
| 6.9.2(Coliform count) |
- |
500 |
|
N.A. |
| 6.9.3(Escherichia coli) |
- |
500 |
|
N.A. |
| 6.9.4(Staphylococcus Aureus) |
- |
500 |
|
N.A. |
| 6.9.5(Salmonella and shigella) |
- |
500 |
|
N.A. |
| 6.9.6(Yeast and mould count) |
- |
500 |
|
N.A. |
| 6.1(Moisture) |
- |
250 |
|
N.A. |
| 6.1(Milk protein) |
- |
250 |
|
N.A. |
| 6.1(Milk fat) |
- |
125 |
|
N.A. |
| 6.1(Total fat) |
- |
125 |
|
N.A. |
| 6.1(Total ash) |
- |
400 |
|
N.A. |
| 6.1(Acid insoluble ash) |
- |
400 |
|
N.A. |
| 6.1(Insolubility index) |
- |
200 |
|
N.A. |
| 6.1(Solubility) |
- |
200 |
|
N.A. |
| 6.1(Vitamin A (as Retinol)) |
- |
750 |
|
N.A. |
| 6.1(Iron) |
- |
250 |
|
N.A. |
| 6.1(Lead) |
- |
250 |
|
N.A. |
| 6.1(Arsenic) |
- |
250 |
|
N.A. |
| 6.1(Tin) |
- |
250 |
|
N.A. |
| 6.1(Cadmium) |
- |
250 |
|
N.A. |
| 6.1(Added Vitamin D (expressed as chole-calciferol)) |
- |
750 |
|
N.A. |
| 6.1(Thiamin) |
- |
750 |
|
N.A. |
| 6.1(Niacin) |
- |
750 |
|
N.A. |
| 6.1(Riboflavin) |
- |
750 |
|
N.A. |
| 6.1(Vitamin B6) |
- |
750 |
|
N.A. |
| 6.1(Vitamin B12) |
- |
750 |
|
N.A. |
| 6.1(Folic acid) |
- |
500 |
|
N.A. |
| 6.1(Pentothenic acid) |
- |
500 |
|
N.A. |
| 6.1(Biotin ) |
- |
500 |
|
N.A. |
| 6.1(Vitamin C) |
- |
750 |
|
N.A. |
| 6.1(Vitamin K) |
- |
750 |
|
N.A. |
| 6.1(Calcium) |
- |
300 |
|
N.A. |
| 6.1(Phosphorus) |
- |
300 |
|
N.A. |
| 6.1(Iodine) |
- |
500 |
|
N.A. |
| 6.1(Copper) |
- |
300 |
|
N.A. |
| 6.1(Manganese) |
- |
300 |
|
N.A. |
| 6.1(Zinc) |
- |
300 |
|
N.A. |
| 6.1(Sodium) |
- |
200 |
|
N.A. |
| 6.1(Potassium) |
- |
200 |
|
N.A. |
| 6.1(Chloride) |
- |
200 |
|
N.A. |
| 6.1(Magnesium) |
- |
200 |
|
N.A. |
| 6.1(Choline) |
- |
200 |
|
N.A. |
| 6.1(Selenium) |
- |
300 |
|
N.A. |
| 6.1(Vitamin E ( as alpha tocopherol compounds)) |
- |
750 |
|
N.A. |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 48 |
IS 302 : Part 2 : Sec 201 (2008) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 201 electric immersion water heaters (First Revision) |
- |
-
|
- View breakup
Rs.10000.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
17 Jun, 2024 |
- Except Cl.24 cycle test for components |
| 49 |
IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
-
|
- View breakup
Rs.45000/- for adapters
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
17 Jun, 2024 |
- Exlcuding clause 24 & clause 19.11.4.2. |
| 50 |
IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
-
|
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
1000 |
|
- |
| 8(Protection against live parts) |
- |
1500 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
2000 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
2000 |
|
- |
| 11(HEATING) |
- |
3000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
3000 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
2500 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
3000 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
3000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
2500 |
|
- |
| 18(ENDURANCE) |
- |
2000 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
2500 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
2000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
2000 |
|
- |
| 22(CONSTRUCTION) |
- |
1000 |
|
- |
| 23(INTERNAL WIRING) |
- |
1000 |
|
- |
| 24(COMPONENTS) |
- |
1000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
2000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
2000 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
2500 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
2500 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
2500 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 51 |
IS 10124 : Part 1 (2009) |
Fabricated PVC-U Fittings for Potable Water Supplies - Specification Part 1 General Requirements (Second Revision) |
- |
-
|
2500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Material) |
- |
100 |
|
For BIS samples 1.5 times of BIS testing charges |
| 4(Size of fitting) |
- |
100 |
|
For BIS samples 1.5 times of BIS testing charges |
| 5.1 Table-1 Fig.1(Dimension of Socket length) |
- |
100 |
|
For BIS samples 1.5 times of BIS testing charges |
| 5.1.2 Table-1(Dimensions of mean inside diameter at mid-point of socket depth) |
- |
100 |
|
For BIS samples 1.5 times of BIS testing charges |
| 5.1.3 (Out of Roundness Tolerance of Socket Inside Diameter) |
- |
150 |
|
For BIS samples 1.5 times of BIS testing charges |
| 5.2 Table-2 Fig.2(Dimensions of socket for elastomeric sealing ring) |
- |
150 |
|
For BIS samples 1.5 times of BIS testing charges |
| 6.1(Opacity test in accordance with IS 12235 (Part 3)) |
- |
750 |
|
For BIS samples 1.5 times of BIS testing charges |
| 6.2(Short Term Hydraulic Test in accordance with Annex A) |
- |
1250 |
|
For BIS samples 1.5 times of BIS testing charges |
| 8(Marking) |
- |
100 |
|
For BIS samples 1.5 times of BIS testing charges |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 52 |
IS 10124 : Part 2 (2009) |
Fabricated pvc - U fittings for potable water supplies - Specification: Part 2 specific requirements for sockets (Second Revision) |
- |
-
|
7000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2.1, Table-1, Fig-1(Nominal size) |
- |
100 |
|
NA |
| 3.2.1, Table-1, Fig-1(B) |
- |
100 |
|
NA |
| 3.2.1, Table-1, Fig-1(Minimum wall thickness for working pressure) |
- |
100 |
|
NA |
| 3.2.1, Table-1, Fig-1(Plumbing) |
- |
100 |
|
NA |
| Clause 3.2.2, and Fig. 2(Nominal size) |
- |
100 |
|
NA |
| Clause 3.2.2, and Fig. 2.(B) |
- |
100 |
|
NA |
| Clause 3.2.2, and Fig. 2.(Minimum wall thickness for working pressure) |
- |
100 |
|
NA |
| 3.2.2, and Fig. 2(Dimensions of Socket for Elastomeric Sealing Ring Joint) |
- |
100 |
|
NA |
| 10.3 of IS 4985 & Cl. 3.1 of IS 12235(P-4)(Effect on water: Lead (First Extraction)) |
- |
500 |
|
NA |
| 10.3 of IS 4985 & Cl. 3.1 of IS 12235(P-4)(Effect on water: Lead (Third Extraction)) |
- |
500 |
|
NA |
| 10.3 of IS 4985 & Cl. 3.1 of IS 12235(P-10)(Effect on water:Dialkyl tin C4 and
higher homologues
measured as tin (third
extraction)) |
- |
500 |
|
NA |
| 10.3 of IS 4985 & Cl. 3.2 of IS 12235(P-4)(Effect on water: Cadmium (all three extracts)) |
- |
500 |
|
NA |
| 10.3 of IS 4985 & Cl. 3.2 of IS 12235(P-4)(Effect on water: Mercury (all three extracts)) |
- |
500 |
|
NA |
| 10.3 of IS 4985 & Cl. 3.2 of IS 12235(P-10)(Other toxic substances such as 'di-n-octyl-tin- s-s bis iso-octyl mercapto acetate' and 'butyl stearate' (third extraction)) |
- |
500 |
|
NA |
| 10.7 of IS 4985(Sulphated Ash content, Annex-B of IS 4985) |
- |
1500 |
|
NA |
| 3.1(General) |
- |
500 |
|
NA |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 53 |
IS 710 (2010) |
Marine plywood - Specification (Second Revision) |
- |
-
|
13000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(DIMENSIONS) |
- |
160 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 6.2(DIMENSIONS) |
- |
160 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 6.3(DIMENSIONS) |
- |
180 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 7.1(WORKMANSHIP AND FINISH ) |
- |
60 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 7.2(WORKMANSHIP AND FINISH ) |
- |
60 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 7.3(WORKMANSHIP AND FINISH ) |
- |
60 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 7.5(WORKMANSHIP AND FINISH ) |
- |
60 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 9.1.1(MOISTURE CONTENT) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 9.1.2 , 9.1.2.1(Glue Adhesion in Dry State) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 9.1.2 , 9.1.2.2(Glue Adhesion in Dry State) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 9.1.3 , 9.1.3.1.1(Water resistance test) |
- |
2000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 9.1.3 , 9.1.3.1.2(Water resistance test) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 9.1.4(Tensile strength) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 9.1.5(Mycological test) |
- |
2000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 9.1.5 , 9.1.3.1.1(Mycological test) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 9.1.5 , 9.1.3.1.2(Mycological test) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 9.1.6 (Table 3)(Static bending strength) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 9.1.7 (Table 4)(Wet bending strength) |
- |
1500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 9.1.8(Retention of preservative) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 11.1(MARKING) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 11.2(MARKING) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| 6.3(DIMENSIONS) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.2, 9.1.2.1 (Cl. 9.1.2 (Glue Adhesion in Dry State), 9.1.2.1 ( Glue Shear Strength: Individual)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.2, 9.1.2.1 (Cl. 9.1.2 (Glue Adhesion in Dry State), 9.1.2.1 ( Glue Shear Strength: Average )) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.3, 9.1.3.1.1 (Cl. 9.1.3 (Water Resistance Test ), 9.1.3.1.1 (Glue Shear Strength: Average)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.3, 9.1.3.1.1 (Cl. 9.1.3 (Water Resistance Test) , 9.1.3.1.1 (Glue Shear Strength: Individual)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.4(Cl. 9.1.4 (Tensile Strength: Sum of the Tensile Strength in two directions)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.4 (Cl. 9.1.4 (Tensile Strength: Perpendicular to grain)) |
- |
400 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.4(Cl. 9.1.4 (Tensile Strength: Parallel to grain)) |
- |
400 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl.9.1.5,9.1.3.1.1 (Cl.9.1.5 (Mycological Test),9.1.3.1.1 ( Glue Shear Strength: Average)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl.9.1.5,9.1.3.1.1 (Cl.9.1.5 (Mycological Test),9.1.3.1.1 (Glue Shear Strength: Individual)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Rupture: Across the Face Grain: Minimum Individual)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Rupture: Across the Face Grain: Average)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Rupture: Along the Face Grain: Minimum Individual)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Rupture: Along the Face Grain: Average)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.6 (Table 3)(Cl. 9.1.6 (Table 3) (Modulus of Elasticity: Across the Face Grain: Minimum Individual)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Elasticity: Across the Face Grain: Average)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Elasticity: Along the Face Grain: Minimum Individual)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Elasticity: Along the Face Grain: Average)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Rupture: Across the Face Grain: Minimum Individual)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Rupture: Across the Face Grain: Average)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Rupture: Along the Face Grain: Minimum Individual)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Rupture: Along the Face Grain: Average)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.7 (Table 4)(Cl. 9.1.7 (Table 4) (Modulus of Elasticity: Across the Face Grain: Minimum Individual)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Elasticity: Across the Face Grain: Average)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Elasticity: Along the Face Grain: Minimum Individual)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
| Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Elasticity: Along the Face Grain: Average)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.13,000/- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 54 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
-
|
117000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.5(Components) |
- |
2000 |
|
- |
| 1.6(Power interface .) |
- |
5000 |
|
- |
| 1.7(Markings and instructions) |
- |
3000 |
|
- |
| 2.1(Protection from electric shock and energy hazards) |
- |
5000 |
|
- |
| 2.2(SELV circuits) |
- |
5000 |
|
- |
| 2.3(TNV circuits) |
- |
3000 |
|
- |
| 2.4(Limited current circuits) |
- |
6000 |
|
- |
| 2.5(Limited power sources .) |
- |
6000 |
|
- |
| 2.6(Provisions for earthing and bonding) |
- |
8000 |
|
- |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
3000 |
|
- |
| 2.8(Safety interlocks) |
- |
2000 |
|
- |
| 2.8.2/2.8.5(Interlock switches) |
- |
2000 |
|
- |
| 2.8.7(Switches and Relay) |
- |
1000 |
|
- |
| 2.9(Electrical insulation) |
- |
8000 |
|
- |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
1000 |
|
- |
| 2.10.4.2(Material Group and Comparative Tracking Index) |
- |
1000 |
|
- |
| 2.10.5.3(Insulating Compound as Solid Insulation) |
- |
500 |
|
- |
| 2.10.5.4(Opto-coupler) |
- |
100 |
|
- |
| 2.10.5.6(Thin sheet materials) |
- |
100 |
|
- |
| 2.10.5.11(SMPS Transformer and Inductor) |
- |
500 |
|
- |
| 2.10.5.12(Wires in wound components) |
- |
500 |
|
- |
| 2.10.5.13(Winding wire) |
- |
100 |
|
- |
| 2.10.5.14(Additional insulation in wound components) |
- |
200 |
|
- |
| 2.10.6(PCB material) |
- |
300 |
|
- |
| 2.10.8.2(Thermal conditioning (thermal ageing)) |
- |
2000 |
|
- |
| 2.10.8.4(Abrasion resistance test) |
- |
2000 |
|
- |
| 2.10.9(Thermal Cycling) |
- |
2000 |
|
- |
| 2.10.10(Test for Pollution Degree 1 environment and for insulating compound) |
- |
500 |
|
- |
| 2.10.11(Tests for semiconductor devices and for cemented joints) |
- |
200 |
|
- |
| 2.10.12(Enclosed and sealed parts) |
- |
200 |
|
- |
| 3.1(General) |
- |
500 |
|
- |
| 3.1.4(Internal wire) |
- |
500 |
|
- |
| 3.2(Connection to a mains supply) |
- |
1000 |
|
- |
| 3.2.4(Appliance inlet /connector) |
- |
500 |
|
- |
| 3.2.5(Non re-wirable plug with PVC sheathed cable) |
- |
500 |
|
- |
| 3.3(Wiring terminals for connection of external conductors) |
- |
1000 |
|
- |
| 3.4(Disconnection from the mains supply) |
- |
1000 |
|
- |
| 3.5(Interconnection of equipment) |
- |
1000 |
|
- |
| 4.1(Stability) |
- |
3000 |
|
- |
| 4.2(Mechanical strength) |
- |
1000 |
|
- |
| 4.2.8(Cathode Ray Tubes) |
- |
1000 |
|
- |
| 4.3(Design and construction) |
- |
2000 |
|
- |
| 4.3.8(Batteries) |
- |
500 |
|
- |
| 4.3.10(Dust, powders, liquids and gases) |
- |
3000 |
|
- |
| 4.3.11(Containers for liquids or gases) |
- |
500 |
|
- |
| 4.3.12(Flammable liquids) |
- |
1000 |
|
- |
| 4.3.13.2(Ionizing radiation) |
- |
1000 |
|
- |
| 4.3.13.3/ Annex Y(Effect of UV radiation on material/Ultraviolet conditioning test) |
- |
1000 |
|
- |
| 4.3.13.4(Human exposure to ultraviolet (UV) radiation) |
- |
1000 |
|
- |
| 4.3.13.5(LED, laser class) |
- |
1000 |
|
- |
| 4.4(Protection against hazardous moving parts) |
- |
2000 |
|
- |
| 4.5(Thermal requirements) |
- |
2000 |
|
- |
| 4.6(Openings in enclosures) |
- |
1000 |
|
- |
| 4.7(Resistance to fire) |
- |
2000 |
|
- |
| 5.1(Touch current and protective conductor curren) |
- |
2000 |
|
- |
| 5.2(Electric strength) |
- |
3000 |
|
- |
| 5.3(Abnormal operating and fault conditions) |
- |
3000 |
|
- |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
1000 |
|
- |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
1000 |
|
- |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
1000 |
|
- |
| 7.1(General) |
- |
1000 |
|
- |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
1000 |
|
- |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
1000 |
|
- |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
1000 |
|
- |
| Annex B(Motor tests under abnormal conditions) |
- |
2000 |
|
- |
| Annex C(Transformers) |
- |
2000 |
|
- |
| Annex DD(Requirements for the mounting means of a rack mounted equipment) |
- |
1000 |
|
- |
| Annex EE(Household and home/ office document/ media shredders) |
- |
1000 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 55 |
IS 4990 (2011) |
Plywood for concrete shuttering works - Specification (Third Revision) |
- |
-
|
- View breakup
Rs.14750.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
17 Jun, 2024 |
- - |
| 56 |
IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
- |
-
|
48000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
1000 |
|
- |
| 5(Classification of Luminaires') |
- |
1000 |
|
- |
| 6.0(Marking) |
- |
1500 |
|
- |
| 7.0(Construction) |
- |
3000 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
3000 |
|
- |
| 9.0(Provision for earthing) |
- |
5000 |
|
- |
| 10.0(Terminals) |
- |
3000 |
|
- |
| 11.0(External & Internal Wiring) |
- |
3000 |
|
- |
| 12.0(Protection against electric shock) |
- |
3000 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
8000 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
3000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
- |
| 17.0(Photometric Test) |
- |
2000 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 57 |
IS 13098 (2012) |
Automotive vehicles - Tubes for pneumatic tyres - Specification (First Revision) |
- |
-
|
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3/3.1 (for valve refer IS 9081)(MATERIALS, FORM AND FIT) |
- |
1000 |
|
N.A. |
| 3/3.3(Uniformity(The Thickness shall not vary from the arithmetic mean of the readings by ± 17.5 % at any point in longitudinal direction :-Crown centre,Base centre,Side wall - 1,Side wall - 2)) |
- |
250 |
|
N.A. |
| 4/4.1.1(Elongation at break (Class A' Tubes)) |
- |
1500 |
|
N.A. |
| 4/4.1.1(Elongation at break (Class B' Tubes)) |
- |
1500 |
|
N.A. |
| 4/4.1.2( Strength of Splice (Class A' Tubes)) |
- |
1500 |
|
N.A. |
| 4/4.1.2( Strength of Splice (Class B' Tubes)) |
- |
1500 |
|
N.A. |
| 4/4.1.3 Refer annex B(Set After Ageing(Class A' Tubes)) |
- |
2500 |
|
N.A. |
| 4/4.1.3 Refer annex B(Set After Ageing(Class B' Tubes)) |
- |
2500 |
|
N.A. |
| 4/4.1.4 Refer annex C(Accelerated Ageing(Both Class A and Class B)) |
- |
3000 |
|
N.A. |
| 5(AIR TIGHTNESS) |
- |
1500 |
|
N.A. |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 58 |
IS 15965 (2012) |
Pre - Painted aluminium zinc alloy metallic coated steel strip and sheet (Plain) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
17 Jun, 2024 |
- - |
| 59 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
-
|
- View breakup
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.55000.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
17 Jun, 2024 |
- Restricted to cap type B22d, E27, & E14 only |
| 60 |
IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
- |
-
|
- View breakup
Rs.60000.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
17 Jun, 2024 |
- Included w.e.f. 15-10-2020 |