| 1 |
IS 4985 (2021) |
UNPLASTICIZED PVC PIPES FOR POTABLE WATER SUPPLIES SPECIFICATION Fourth Revision |
- |
-
|
28000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(CLASSIFICATION OF PIPES) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 6.1.2(PVC Resin) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Minimum)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Mamimum)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. Variation) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Maximum)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 7.1.1.2(DIMENSIONS-PIPE-Ovality (Maximum)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 7.1.2.1(DIMENSIONS-PIPE-Average Thickness) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Minimum Length) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Minimum)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Maximum)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 7.2.1.2(a)-Table 5(DIMENSIONS-Sockets for elastomeric sealing ring joints-Minimum depth of engagement) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 7.2.1.2-Table 4(DIMENSIONS-Sockets for elastomeric sealing ring joints-Socket inner Diameter) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 8(SEALING RINGS) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 9.1(PIPE ENDS) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 10.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 10.1(Colour) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 10.1(Surface Finish) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 10.2(PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 10.4(PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 10.5(PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 10.6(PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 10.7(Sulphated Ash Content) |
- |
1500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)) |
- |
10000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)-for Integral Sealing Ring Sockets) |
- |
10000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Integral Sealing Ring Sockets) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 11.1.1(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Plumbing pipes) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 11.2(Resistance to External Blows at 0°C) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 7.1.3(mean outside diameter, outside diameter at
any point, and wall thickness of plumbing pipes) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 7.1.4(Length) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
| 10.3(Effect on Water Test) |
- |
2000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others:Rs.28000.00 |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 2 |
IS 1293 (2005) |
Plugs and socket- outlets of rated voltage up to and including 250 volts and rated current up to 16 amperes |
- |
-
|
17000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(RATINGS) |
- |
100 |
|
For BIS sample 1.5 times of BIS testing charges, For other: Rs.10000/- upto 10A, Rs.15000/- Above 10A. |
| 6.1(RATINGS) |
- |
100 |
|
- |
| 6.2(RATINGS) |
- |
100 |
|
- |
| 7(CLASSIFICATION) |
- |
100 |
|
- |
| 7.1(CLASSIFICATION) |
- |
100 |
|
- |
| 7.1.1 (CLASSIFICATION) |
- |
100 |
|
- |
| 7.1.2(CLASSIFICATION) |
- |
100 |
|
- |
| 7.1.3 (CLASSIFICATION) |
- |
100 |
|
- |
| 7.1.4(CLASSIFICATION) |
- |
100 |
|
- |
| 7.2(CLASSIFICATION) |
- |
100 |
|
- |
| 7.2.1(CLASSIFICATION) |
- |
100 |
|
- |
| 7.2.2 (CLASSIFICATION) |
- |
100 |
|
- |
| 7.2.3(CLASSIFICATION) |
- |
100 |
|
- |
| 7.2.4(CLASSIFICATION) |
- |
100 |
|
- |
| 7.2.5(CLASSIFICATION) |
- |
100 |
|
- |
| 7.3(CLASSIFICATION) |
- |
100 |
|
- |
| 8.1(MARKING) |
- |
200 |
|
- |
| 8.2(MARKING) |
- |
100 |
|
- |
| 8.3(MARKING) |
- |
100 |
|
- |
| 8.4(MARKING) |
- |
100 |
|
- |
| 8.5(MARKING) |
- |
100 |
|
- |
| 8.6(MARKING) |
- |
100 |
|
- |
| 8.7(MARKING) |
- |
200 |
|
- |
| 8.8(MARKING) |
- |
100 |
|
- |
| 9.1(CHECKING OF DIMENSIONS) |
- |
500 |
|
- |
| 9.2(CHECKING OF DIMENSIONS) |
- |
200 |
|
- |
| 9.3(CHECKING OF DIMENSIONS) |
- |
200 |
|
- |
| 10(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
200 |
|
- |
| 10.2(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
200 |
|
- |
| 10.2.1(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
100 |
|
- |
| 10.2.2(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
100 |
|
- |
| 10.3(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
200 |
|
- |
| 10.5(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
200 |
|
- |
| 10.6(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
100 |
|
- |
| 10.7(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
200 |
|
- |
| 10.4(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
100 |
|
- |
| 11(PROVISION FOR EARTHING) |
- |
200 |
|
- |
| 11.1(PROVISION FOR EARTHING) |
- |
100 |
|
- |
| 11.2(PROVISION FOR EARTHING) |
- |
200 |
|
- |
| 11.3(PROVISION FOR EARTHING) |
- |
100 |
|
- |
| 11.4(PROVISION FOR EARTHING) |
- |
100 |
|
- |
| 11.5(PROVISION FOR EARTHING) |
- |
200 |
|
- |
| 12(TERMINALS) |
- |
100 |
|
- |
| 12.1.1(TERMINALS) |
- |
100 |
|
- |
| 12.1.2(TERMINALS) |
- |
100 |
|
- |
| 12.2(TERMINALS) |
- |
200 |
|
- |
| 12.2.1(TERMINALS) |
- |
100 |
|
- |
| 12.2.2(TERMINALS) |
- |
100 |
|
- |
| 12.2.3(TERMINALS) |
- |
100 |
|
- |
| 12.2.4(TERMINALS) |
- |
100 |
|
- |
| 12.2.5(TERMINALS) |
- |
200 |
|
- |
| 12.2.6(TERMINALS) |
- |
200 |
|
- |
| 12.2.7(TERMINALS) |
- |
200 |
|
- |
| 12.2.8(TERMINALS) |
- |
200 |
|
- |
| 12.2.9(TERMINALS) |
- |
200 |
|
- |
| 12.2.10(TERMINALS) |
- |
200 |
|
- |
| 12.2.11(TERMINALS) |
- |
200 |
|
- |
| 12.3(TERMINALS) |
- |
200 |
|
- |
| 12.3.1(TERMINALS) |
- |
200 |
|
- |
| 12.3.2(TERMINALS) |
- |
200 |
|
- |
| 12.3.3(TERMINALS) |
- |
200 |
|
- |
| 12.3.4(TERMINALS) |
- |
200 |
|
- |
| 12.3.5(TERMINALS) |
- |
200 |
|
- |
| 12.3.6(TERMINALS) |
- |
200 |
|
- |
| 12.3.7(TERMINALS) |
- |
200 |
|
- |
| 12.3.8(TERMINALS) |
- |
200 |
|
- |
| 12.3.9(TERMINALS) |
- |
200 |
|
- |
| 12.3.10(TERMINALS) |
- |
500 |
|
- |
| 12.3.11 (a)(TERMINALS) |
- |
250 |
|
- |
| 12.3.11 (b)(TERMINALS) |
- |
250 |
|
- |
| 12.3.12 (TERMINALS) |
- |
500 |
|
- |
| 13.1(Construction of fixed Socket Outlets) |
- |
100 |
|
- |
| 13.2(Construction of fixed Socket Outlets) |
- |
100 |
|
- |
| 13.3(Construction of fixed Socket Outlets) |
- |
100 |
|
- |
| 13.4(Construction of fixed Socket Outlets) |
- |
100 |
|
- |
| 13.4(Construction of fixed Socket Outlets) |
- |
100 |
|
- |
| 13.4(Construction of fixed Socket Outlets) |
- |
100 |
|
- |
| 13.4(Construction of fixed Socket Outlets) |
- |
100 |
|
- |
| 13.4(Construction of fixed Socket Outlets) |
- |
100 |
|
- |
| 13.5(Construction of fixed Socket Outlets) |
- |
100 |
|
- |
| 13.7(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.7.1(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.7.2 (CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
200 |
|
- |
| 13.7.3 (CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
200 |
|
- |
| 13.8(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.9(Construction of fixed Socket Outlets) |
- |
100 |
|
- |
| 13.1(Construction of fixed Socket Outlets) |
- |
100 |
|
- |
| 13.11(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.12(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.13(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.14(Construction of fixed Socket Outlets) |
- |
200 |
|
- |
| 13.15(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.16(Construction of fixed Socket Outlets) |
- |
200 |
|
- |
| 13.17(Construction of fixed Socket Outlets) |
- |
100 |
|
- |
| 13.18(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.19(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.2(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.21(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
200 |
|
- |
| 13.22(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
200 |
|
- |
| 13.23(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
200 |
|
- |
| 14.1(Construction of Plugs & Portables socket outlet ) |
- |
100 |
|
- |
| 14.2(Construction of Plugs & Portables socket outlet ) |
- |
200 |
|
- |
| 14.3(Construction of Plugs & Portables socket outlet ) |
- |
200 |
|
- |
| 14.4(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.5(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.6(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.7(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
-- |
| 14.8(Construction of Plugs & Portables socket outlet ) |
- |
100 |
|
- |
| 14.9(Construction of Plugs & Portables socket outlet ) |
- |
100 |
|
- |
| 14.1(Construction of Plugs & Portables socket outlet ) |
- |
200 |
|
- |
| 14.11(Construction of Plugs & Portables socket outlet ) |
- |
200 |
|
- |
| 14.12(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.13(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.14(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.15(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.16(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.17(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.18(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.19(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
200 |
|
- |
| 14.21(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.22(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.23(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.23.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
200 |
|
- |
| 14.23.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
200 |
|
- |
| 14.24(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
200 |
|
- |
| 14.25(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
200 |
|
- |
| 15.0(Interlocked socket-outlets) |
- |
500 |
|
- |
| 16.1(Resistance to Ageing ) |
- |
500 |
|
- |
| 16.2(Resistance to Harmful Ingress of Water) |
- |
500 |
|
- |
| 16.2.1(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
200 |
|
- |
| 16.2.2(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
200 |
|
- |
| 16.2.3(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
200 |
|
- |
| 16.2.4(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
200 |
|
- |
| 16.3(Resistance to humidity) |
- |
500 |
|
- |
| 17.1(Insulation Resistance) |
- |
500 |
|
- |
| 17.1.1(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
500 |
|
- |
| 17.1.2(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
500 |
|
- |
| 17.2( Electric Strength) |
- |
500 |
|
- |
| 17.3(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
500 |
|
- |
| 18.0(Operation of Earthing Contacts) |
- |
200 |
|
- |
| 19.0(Temperature Rise ) |
- |
200 |
|
- |
| 20.0(Making & Breaking Capacity) |
- |
500 |
|
- |
| 21.0(Normal Operation) |
- |
200 |
|
- |
| 21.0(Normal Operation) |
- |
200 |
|
- |
| 21.0(Normal Operation) |
- |
200 |
|
- |
| 21.0(Normal Operation) |
- |
200 |
|
- |
| 22.1(Verification of Max withdrawal force) |
- |
100 |
|
- |
| 22.2(Verification of Minimum withdrawal force) |
- |
100 |
|
- |
| 23.1(Flexible cables & their connection ) |
- |
100 |
|
- |
| 23.2(Flexible cables & their connection ) |
- |
200 |
|
- |
| 23.3(Flexible cables & their connection ) |
- |
200 |
|
- |
| 23.4(Flexible cables & their connection ) |
- |
200 |
|
- |
| 24.1(a) Mechanical Strength
) |
- |
200 |
|
- |
| 24.2(For Portable single socket outlets/ plugs) |
- |
200 |
|
- |
| 24.3(MECHANICAL STRENGTH) |
- |
200 |
|
- |
| 24.4(For Portable socket outlets/ plugs) |
- |
200 |
|
- |
| 24.5(For Portable single socket outlets/ plugs) |
- |
200 |
|
- |
| 24.6(b) For screwed glands of accessories other than ordinary) |
- |
200 |
|
- |
| 24.7(For plug pins provided with insulating sleeves) |
- |
200 |
|
- |
| 24.8(c) For shuttered socket-outlets ) |
- |
100 |
|
- |
| 24.9(For portable multiple and combined socket outlets) |
- |
100 |
|
- |
| 24.1(For plugs) |
- |
200 |
|
- |
| 24.11(For portable socket outlets having means for suspension on a wall) |
- |
100 |
|
- |
| 24.12(For portable socket outlets having means for suspension on a wall) |
- |
100 |
|
- |
| 24.13(For portable socket outlets having means for suspension on a wall) |
- |
100 |
|
- |
| 24.14(MECHANICAL STRENGTH) |
- |
100 |
|
- |
| 24.14.1(e)Verification of the Non-removal of Covers or Cover-Plates ) |
- |
100 |
|
- |
| 24.14.2(f)Verification of the Removal of Covers or Cover-Plates ) |
- |
100 |
|
- |
| 24.15(Verification of the Removal of Covers or Cover-Plates ) |
- |
100 |
|
- |
| 24.16(Verification of the Removal of Covers or Cover-Plates ) |
- |
100 |
|
- |
| 24.17(Verification of the Removal of Covers or Cover-Plates ) |
- |
200 |
|
- |
| 24.18(Verification of the Removal of Covers or Cover-Plates ) |
- |
100 |
|
- |
| 25.1(RESISTANCE TO HEAT) |
- |
100 |
|
- |
| 25.2(RESISTANCE TO HEAT) |
- |
200 |
|
- |
| 25.3(RESISTANCE TO HEAT) |
- |
200 |
|
- |
| 25.4(RESISTANCE TO HEAT) |
- |
200 |
|
- |
| 26.1(Screws, current carrying parts and connections) |
- |
100 |
|
- |
| 26.2(Screws, current carrying parts and connections) |
- |
100 |
|
- |
| 26.3(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
| 26.4(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
| 26.5(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
| 26.6(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
| 26.7(Screws, current carrying parts and connections) |
- |
100 |
|
- |
| 27.1(Creepage distances, clearances and distances through sealing compound ) |
- |
200 |
|
- |
| 27.2(Creepage distances, clearances and distances through sealing compound ) |
- |
100 |
|
- |
| 27.3(Creepage distances, clearances and distances through sealing compound ) |
- |
100 |
|
- |
| 28.1.1(Glow-Wire Test ) |
- |
500 |
|
- |
| 28.1.2(Addiitional tests for plugs with pins provided with insulating sleeves) |
- |
500 |
|
- |
| 28.2(Resistance to Tracking) |
- |
500 |
|
- |
| 29.0(Resistance to Rusting) |
- |
200 |
|
- |
| 30.1(Addiitional tests on pins provided with insulating sleeves - Pressure Test at High Temperature) |
- |
200 |
|
- |
| 30.2(Addiitional tests on pins provided with insulating sleeves - Static Damp Heat Test) |
- |
200 |
|
- |
| 30.3(Addiitional tests on pins provided with insulating sleeves - Impact Test at Low Temperature) |
- |
200 |
|
- |
| 30.4(Addiitional tests on pins provided with insulating sleeves - Tests at Low Temperature) |
- |
200 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 3 |
IS 9873 : Part 9 (2017) |
Safety of Toys Part 9 Certain Phthalates Esters in Toys and Children's Products |
- |
-
|
6000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.0(Vinyl in toys or childcare articles - a) Bis-(2-ethlyhexyl) Phthalates (DEHP), b) Di-Butyl phthalate (DBP), c) Benzyl butyl Phthalate (BBP) - IS 9873 Part 6) |
- |
3000 |
|
- |
| 3.0(Vinyl in any part of the toy or childcare article that can be placed in mouth of a child under 4 years of age - a) Di-iso-Nonyl Phthalate (DINP), b) Di-iso-Decyl Phthalate (DIDP), c) Di-n-Octyl Phthalate (DNOP) - IS 9873 Part 6) |
- |
3000 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 4 |
IS 9873 : Part 3 (2020) |
Safety of Toys Part 3 Migration of Certain Elements ( Third Revision ) |
- |
-
|
5000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 - Table 1(Antimony (Sb) - Cl 7,8,9 of IS 9873-3 : 2017 and ISO 8124-3 : 2010) |
- |
625 |
|
- |
| 4.1 - Table 1(Arsenic (As) - Cl 7,8,9 of IS 9873-3 : 2017 and ISO 8124-3 : 2010) |
- |
625 |
|
- |
| 4.1 - Table 1(Barium (Ba) - Cl 7,8,9 of IS 9873-3 : 2017 and ISO 8124-3 : 2010) |
- |
625 |
|
- |
| 4.1 - Table 1(Cadmium (Cd) - Cl 7,8,9 of IS 9873-3 : 2017 and ISO 8124-3 : 2010) |
- |
625 |
|
- |
| 4.1 - Table 1(Chromium (Cr) - Cl 7,8,9 of IS 9873-3 : 2017 and ISO 8124-3 : 2010) |
- |
625 |
|
- |
| 4.1 - Table 1(Lead (Pb) - Cl 7,8,9 of IS 9873-3 : 2017 and ISO 8124-3 : 2010) |
- |
625 |
|
- |
| 4.1 - Table 1(Mercury (Hg) - Cl 7,8,9 of IS 9873-3 : 2017 and ISO 8124-3 : 2010) |
- |
625 |
|
- |
| 4.1 - Table 1(Selenium (Se) - Cl 7,8,9 of IS 9873-3 : 2017 and ISO 8124-3 : 2010) |
- |
625 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 5 |
IS 9573 : Part 1 (2017) |
Rubber hose for liquefied petroleum gas (Lpg) - Specification: Part 1 industrial application (Fourth Revision) |
- |
-
|
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.1 (General) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.2(Material) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.2.1(Lining) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.2.2(Reinforcement) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.2.3(Cover) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.3
Sub Clause 4.3.1
Table 1(Bore Size) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.3
Sub Clause 4.3.2 (a)(Thickness of Lining and Cover) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.3
Sub Clause 4.3.2 (b)(Thickness of Lining and Cover) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.3
Sub Clause 4.3.3(Length) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.1
Table 2 (i) (a)(Tensile Strength- Lining) |
- |
650 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.1
Table 2 (i) (b)(Tensile Strength- cover) |
- |
650 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.1
Table 2 (ii) (a)(Elongation at break- Lining) |
- |
650 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.1
Table 2 (ii) (b)(Elongation at break- cover) |
- |
650 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.2
(a)(Accelerated Ageing Test lining) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.2
(b)(Accelerated Ageing Test lining) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.2
(a)(Accelerated Ageing Test cover) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.2
(b)(Accelerated Ageing Test cover) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.3
(a)(Resistance of Lining to n-pentane) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.3
(b)(Resistance of Lining to n-pentane) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.5
Sub clause 4.5.1(Adhesion) |
- |
1500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.5
Sub clause 4.5.2(Low Temperature Flexibility) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.5
Sub clause 4.5.3(Flexibility of Hose) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.5
Sub clause 4.5.4(Ozone Resistance) |
- |
2000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.5
Sub clause 4.5.5
4.5.5.1(Proof pressure test) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.5
Sub clause 4.5.5
4.5.5.2(Bursting pressure) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.5
Sub clause 4.5.6(Electrical Continuity Test) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.5
Sub clause 4.5.7(Burning Behaviour) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 6 |
IS 9573 : Part 2 (2017) |
Rubber hose for liquefied petroleum gas (Lpg) - Specification: Part 2 domestic and commercial application (Fourth Revision) |
- |
-
|
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.2(Material) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.2.1(Lining) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.2.2 (a)(Reinforcement) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.2.2 (b)(Reinforcement) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.2.3(Cover) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.3
Sub Clause 4.3.1
Table 1(Bore Size) |
- |
150 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.3
Sub Clause 4.3.2 (a)(Thickness of Lining and Cover) |
- |
150 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.3
Sub Clause 4.3.2 (b)(Thickness of Lining and Cover) |
- |
150 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.3
Sub Clause 4.3.3(Length) |
- |
150 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.1
Table 2 (i) (a)(Tensile Strength- Lining) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.1
Table 2 (i) (b)(Tensile Strength- cover) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.1
Table 2 (ii) (a)(Elongation at break- Lining) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.1
Table 2 (ii) (b)(Elongation at break- Cover) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.2
(a)(Accelerated Ageing Test lining) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.2
(b)(Accelerated Ageing Test lining) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.2
(a)(Accelerated Ageing Test cover) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.2
(b)(Accelerated Ageing Test cover) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.3
(a)(Resistance of Lining to n-pentane) |
- |
1500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.4
Sub Clause 4.4.3
(b)(Resistance of Lining to n-pentane) |
- |
1500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.5
Sub clause 4.5.1(Adhesion) |
- |
1500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.5
Sub clause 4.5.2(Low Temperature Flexibility) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.5
Sub clause 4.5.3(Flexibility of Hose) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.5
Sub clause 4.5.4(Ozone Resistance) |
- |
2000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.5
Sub clause 4.5.5
4.5.5.1(Proof pressure test) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.5
Sub clause 4.5.5
4.5.5.2(Bursting pressure) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.5
Sub clause 4.5.6(Grip Strength Test) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 4.5
Sub clause 4.5.7(Burning Behaviour) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 7 |
IS 8323 (2018) |
Palm oil - Specification (First Revision) |
- |
-
|
18000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 5 and sub-clause 5.2(Description) |
- |
250 |
|
- |
| Clause 5 and sub-clause 5.2(Oil Soluble Colour) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.2.1(Clarity of Material) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.4(Aflatoxin) |
- |
1500 |
|
- |
| Clause 5 and sub-clause 5.3(Presence of non-edible oils and adultrants (Karanja Oil, Argemone Oil, Hydrocyanic acid, Mineral Oil, KUSUM OIL AND OTHER OILS CONTAINING CYANOGENIC COMPOUNDS, CASTOR OIL, NEEM OIL)) |
- |
5000 |
|
- |
| Clause 5 and sub-clause 5.5(Metal contaminants) |
- |
2000 |
|
- |
| Clause 5 and sub-clause 5.5(pesticide residues) |
- |
1500 |
|
- |
| Clause 5 and sub-clause 5.6(Propyl Gallate) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.6(Ascorbyl Esters) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.6(BHA) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.6(BHT) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.6(TBHQ) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/i(Moisture and insoluble impurities,percent by weight,Max, Refined Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/i(Moisture and insoluble impurities,percent by weight,Max, Raw Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/ii(Colour on the Lovibond scale, expressed as (Y + 5R), not deeper than, Refined Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/ii(Colour on the Lovibond scale, expressed as (Y + 5R), not deeper than, Raw Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/iii(Refractive index at 40°C, Refined Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/iii(Refractive index at 40°C, Raw Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/iv(Specific gravity at 30°C/30°C, Refined Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/iv(Specific gravity at 30°C/30°C, Raw Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/v(Saponification value, Refined Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/v(Saponification value, Raw Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/vi(Iodine value (Wijs), Refined Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/vi(Iodine value (Wijs), Raw Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/vii(Acid value, Max, Refined Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/vii(Acid value, Max, Raw Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/viii(Unsaponifiable matter, percent by mass, Max, Refined Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/viii(Unsaponifiable matter, percent by mass, Max, Raw Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/ix(Melting point,, Refined Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/ix(Melting point, Raw Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/x(Peroxide value, expressed as milliequivalents of oxygen per kg, Max,Refined Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/x(Peroxide value, expressed as milliequivalents of oxygen per kg, Max, Raw Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/xi(Flash point (Pensky-Martens), closed, °C, Min, Refined Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/xi(Flash point (Pensky-Martens), closed, °C, Min, Refined Grade, Raw Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/xii(Hexane, ppm, Max, Refined Grade) |
- |
1500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/xii(Hexane, ppm, Max, Raw Grade) |
- |
1500 |
|
- |
| Clause 5 and sub-clause 5.8.1.3 Table 2/i (Lead, mg/kg, Max) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8.1.3 Table 2/ii(Arsenic, mg/kg, Max) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8.1.3 Table 2/iii(Cadmium, mg/kg, Max) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8.1.3 Table 2/iv(Mercury (total) mg/kg, Max) |
- |
500 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 8 |
IS 4055 (2018) |
Maize (Corn) oil - Specification (First Revision) |
- |
-
|
18350 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 5 and sub-clause 5.2(Description) |
- |
250 |
|
- |
| Clause 5 and sub-clause 5.2(Peroxide Value) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.2(Oil Soluble Colour) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.2.1(Clarity of Material) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.4(Aflatoxin) |
- |
1500 |
|
- |
| Clause 5 and sub-clause 5.3(Presence of non-edible oils and adultrants (Karanja Oil, Argemone Oil, Hydrocyanic acid, Mineral Oil, KUSUM OIL AND OTHER OILS CONTAINING CYANOGENIC COMPOUNDS, CASTOR OIL, NEEM OIL)) |
- |
5000 |
|
- |
| Clause 5 and sub-clause 5.5(Metal contaminants) |
- |
2000 |
|
- |
| Clause 5 and sub-clause 5.5(pesticide residues) |
- |
2000 |
|
- |
| Clause 5 and sub-clause 5.6(Propyl Gallate) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.6(Ascorbyl Esters) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.6(BHA) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.6(BHT) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.6(TBHQ) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/i(Moisture and insoluble impurities,percent by weight,Max, Refined Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/i(Moisture and insoluble impurities,percent by weight,Max, Raw Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/ii(Colour on the Lovibond scale, expressed as (Y + 5R), not deeper than, Refined Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/ii(Colour on the Lovibond scale, expressed as (Y + 5R), not deeper than, Raw Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/iii(Refractive index at 40°C, Refined Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/iii(Refractive index at 40°C, Raw Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/iv(Specific gravity at 30°C/30°C, Refined Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/iv(Specific gravity at 30°C/30°C, Raw Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/v(Saponification value, Refined Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/v(Saponification value, Raw Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/vi(Iodine value (Wijs), Refined Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/vi(Iodine value (Wijs), Raw Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/vii(Acid value, Max, Refined Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/vii(Acid value, Max, Raw Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/viii(Unsaponifiable matter, percent by mass, Max, Refined Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/viii(Unsaponifiable matter, percent by mass, Max, Raw Grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/ix(Flash point (Pensky-Martens), closed, °C, Min, Refined Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/ix(Flash point (Pensky-Martens), closed, °C, Min, Refined Grade, Raw Grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/x(Hexane, ppm, Max, Refined Grade) |
- |
1500 |
|
- |
| Clause 5 and sub-clause 5.7/ Table 1/x(Hexane, ppm, Max, Raw Grade) |
- |
1500 |
|
- |
| Clause 5 and sub-clause 5.8.1.3 Table 2/i (Lead, mg/kg, Max) |
- |
400 |
|
- |
| Clause 5 and sub-clause 5.8.1.3 Table 2/ii(Arsenic, mg/kg, Max) |
- |
400 |
|
- |
| Clause 5 and sub-clause 5.8.1.3 Table 2/iii(Cadmium, mg/kg, Max) |
- |
400 |
|
- |
| Clause 5 and sub-clause 5.8.1.3 Table 2/iv(Mercury (total) mg/kg, Max) |
- |
400 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 9 |
IS 3491 (2018) |
Safflower seed oil - Specification (First Revision) |
- |
-
|
19100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.0(TYPES AND GRADES) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.1(Description) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.2(Clarity and adulteration) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.3(Non-edible oils presence) |
- |
5000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.4(aflatoxin) |
- |
1500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.5(Metal contaminants and pesticide residues) |
- |
4000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.6(permitted antioxidants and antioxidant synergists) |
- |
1500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.7, Table 1(Moisture and insoluble impurities) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.7, Table 1(Colour in a 1 inch cell on the Lovibond scale, expressed as (Y + 5R)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.7, Table 1(Refractive index at 40ºC) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.7, Table 1(Specific gravity at 30º/30ºC) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.7, Table 1(Saponification value) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.7, Table 1(Iodine value (Wijs) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.7, Table 1(Bellier turbidity temperature, °C) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.7, Table 1(Acid value) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.7, Table 1(Unsaponifiable matter,) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.7, Table 1(Flash point Pensky-Martens (closed), ºC) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.7, Table 1(Hexane) |
- |
1500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.8.1.3, Table 2(Pb) |
- |
400 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.8.1.3, Table 2(As) |
- |
400 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.8.1.3, Table 2(Cd) |
- |
400 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5.8.1.3, Table 2(Hg) |
- |
400 |
|
For BIS samples: 1.5 times of BIS testing charges |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 10 |
IS 547 (2018) |
Sesame oil - Specification (Third Revision) |
- |
-
|
19600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 5 and sub-clause 5.8.1.3 Table 2/iv(Mercury (total) mg/kg, Max) |
- |
400 |
|
- |
| Clause 5 and sub-clause 5.8.1.3 Table 2/iii(Cadmium, mg/kg, Max) |
- |
400 |
|
- |
| Clause 5 and sub-clause 5.8.1.3 Table 2/ii(Arsenic, mg/kg, Max) |
- |
400 |
|
- |
| Clause 5 and sub-clause 5.8.1.3 Table 2/i (Lead, mg/kg, Max) |
- |
400 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/xi(Hexane, ppm, Max, Solvent Extracted - raw grade) |
- |
1500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/xi(Hexane, ppm, Max, Solvent Extracted - refined grade) |
- |
1500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/x(Flash point (Pensky-Martens), closed, °C, Min, Solvent Extracted - raw grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/x(Flash point (Pensky-Martens), closed, °C, Min, Solvent Extracted - refined grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/ix(Bellier turbidity temperature, °C, Max, Expressed- raw grade II) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/ix(Bellier turbidity temperature, °C, Max ,Expressed- Raw grade I) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/viii(Unsaponifiable matter, percent by mass, Max, Solvent Extracted - raw grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/viii(Unsaponifiable matter, percent by mass, Max, Solvent Extracted - refined grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/viii(Unsaponifiable matter, percent by mass, Max, Expressed- refined grade II) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/viii(Unsaponifiable matter, percent by mass, Max, Expressed- Raw grade I) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/viii(Unsaponifiable matter, percent by mass, Max, Expressed- refined grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/vii(Acid value, Max, Solvent Extracted - raw grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/vii(Acid value, Max, Solvent Extracted - refined grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/vii(Acid value, Max, Expressed- refined grade II) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/vii(Acid value, Max, Expressed- Raw grade I) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/vii(Acid value, Max, Expressed- refined grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/vi(Iodine value (Wijs)) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/v(Saponification value) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/iv(Specific gravity at 30°C/30°C) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/iii(Refractive index at 40°C) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/ii(Colour on the Lovibond scale, expressed as (Y + 5R), not deeper than ,Solvent Extracted - raw grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/ii(Colour on the Lovibond scale, expressed as (Y + 5R), not deeper than Solvent Extracted - refined grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/ii(Colour on the Lovibond scale, expressed as (Y + 5R), not deeper than Expressed- raw grade II) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/ii(Colour on the Lovibond scale, expressed as (Y + 5R), not deeper than Expressed- Raw grade I) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/ii(Colour on the Lovibond scale, expressed as (Y + 5R), not deeper than Expressed- refined grade) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/i(Moisture and insoluble impurities,percent by weight,Max, Solvent Extracted - raw grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/i(Moisture and insoluble impurities,percent by weight,Max, Solvent Extracted - refined grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/i(Moisture and insoluble impurities,percent by weight,Max, Expressed- Raw grade II) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/i(Moisture and insoluble impurities,percent by weight,Max Expressed- Raw grade I) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.8/ Table 1/i(Moisture and insoluble impurities,percent by weight,Max Expressed- refined grade) |
- |
750 |
|
- |
| Clause 5 and sub-clause 5.7(TBHQ) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7(BHT) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7(BHA) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7(Ascorbyl Esters) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.7(Propyl Gallate) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.6(pesticide residues) |
- |
1500 |
|
- |
| Clause 5 and sub-clause 5.6(Metal contaminants) |
- |
1600 |
|
- |
| Clause 5 and sub-clause 5.5(Baudouin Test) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.3(Presence of non-edible oils and adultrants (Karanja Oil, Argemone Oil, Hydrocyanic acid, Mineral Oil, KUSUM OIL AND OTHER OILS CONTAINING CYANOGENIC COMPOUNDS, CASTOR OIL, NEEM OIL)) |
- |
5000 |
|
- |
| Clause 5 and sub-clause 5.4(Aflatoxin) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.2.1(Clarity of Material) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.2(Oil Soluble Colour) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.2(Peroxide Value) |
- |
500 |
|
- |
| Clause 5 and sub-clause 5.2(Description) |
- |
250 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 11 |
IS 543 (2018) |
Cottonseed oil - Specification (Third Revision) |
- |
-
|
24400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Description) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 5.7 (Table 1, S. no i)(Moisture and insoluble impurities) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 5.7 (Table 1, S. no ii)(Colour on the Lovibond scal) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 5.7 (Table 1, S. no iii)(Refractive index) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 5.7 (Table 1, S. no iv)(Specific gravity) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 5.7 (Table 1, S. no v)(Saponification value) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 5.7 (Table 1, S. no vi)(Iodine value) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 5.7(Table 1, S. no vii)(Acid value) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 5.7 (Table 1, S. no viii)(Unsaponifiable matter) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 5.7 (Table 1, S. no ix)(Polenske value) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 5.7 (Table 1, S. no x)(Flash point) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 5.7 (Table 1, S. no xi)(Hexane) |
- |
1500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 5.7 (Table 1, S. no xii)(Refining loss) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 5.8.1.3 (Table 2, S. no i)(Lead) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 5.8.1.3 (Table 2, S. no ii)(Arsenic) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 5.8.1.3 (Table 2, S. no iii)(Cadmium) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 5.8.1.3 (Table 2, S. no iv)(Mercury) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl. 7(MARKING) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 12 |
IS 542 (2018) |
Coconut oil - Specification (Third Revision) |
- |
-
|
19600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Description) |
- |
250 |
|
- |
| Cl. 5.7 (Table 1, S. no i)(Moisture and insoluble impurities) |
- |
750 |
|
- |
| Cl. 5.7 (Table 1, S. no ii)(Colour on the Lovibond scal) |
- |
500 |
|
- |
| Cl. 5.7 (Table 1, S. no iii)(Refractive index) |
- |
500 |
|
- |
| Cl. 5.7 (Table 1, S. no iv)(Specific gravity) |
- |
500 |
|
- |
| Cl. 5.7 (Table 1, S. no v)(Saponification value) |
- |
750 |
|
- |
| Cl. 5.7 (Table 1, S. no vi)(Iodine value) |
- |
600 |
|
- |
| Cl. 5.7(Table 1, S. no vii)(Acid value) |
- |
500 |
|
- |
| Cl. 5.7 (Table 1, S. no viii)(Unsaponifiable matter) |
- |
750 |
|
- |
| Cl. 5.7 (Table 1, S. no ix)(Polenske value) |
- |
500 |
|
- |
| Cl. 5.7 (Table 1, S. no x)(Flash point) |
- |
500 |
|
- |
| Cl. 5.7 (Table 1, S. no xi)(Hexane) |
- |
1500 |
|
- |
| Cl. 5.8.1.3 (Table 1, S. no i)(Lead) |
- |
500 |
|
- |
| Cl. 5.8.1.3 (Table 1, S. no ii)(Arsenic) |
- |
500 |
|
- |
| Cl. 5.8.1.3 (Table 1, S. no iv)(Mercury) |
- |
500 |
|
- |
| Cl. 7(MARKING) |
- |
250 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 13 |
IS 513 : Part 2 (2016) |
Cold reduced carbon steel sheet and strip: Part 2 high tensile and multi - Phase steel (Sixth Revision) |
- |
-
|
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(CARBON) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 6.0(SULPHUR) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 6.0(PHOSPHORUS) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 6.0(MANGANESE) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 6.0(SILICON) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 6.0(NITROGEN) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 6.0(MICRO ALLOYS) |
- |
3200 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 6.0(ALUMINIUM) |
- |
400 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl 7(UTM) |
- |
5150 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl 8.5(Workmanship) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl 8.6(Workmanship) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl 9(Workmanship) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl 10(Length, Width & Thickness) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 14 |
IS 170 (2020) |
Acetone — Specification ( Fifth Revision ) |
- |
-
|
11500 View breakup
Rs.11500/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl No 3.1( Description) |
- |
250 |
|
- |
| Cl No 3.2(Miscibility with Water) |
- |
1000 |
|
- |
| Cl 3.3 and 6.1 ANNEX A [ Table 1, Sl No. (i) ](Purity) |
- |
2500 |
|
- |
| Cl 3.3 and 6.1 [ Table 1, Sl No. (ii) ] ref to IS 8768(Colour) |
- |
500 |
|
- |
| Cl 3.3 and 6.1 [ Table 1, Sl No. (iii) ] ref to 6 of IS 82(Relative density, at 27/27 °C) |
- |
750 |
|
- |
| Cl 3.3 and 6.1 [ Table 1, Sl No. (iv) ] IS 1448 (Part 18) with the thermometer containing to the requirements given to Annex B(*Distillation range) |
- |
1000 |
|
- |
| Cl 3.3 and 6.1 [ Table 1, Sl No. (v) ] ref to IS 2362(Water content) |
- |
500 |
|
- |
| Cl 3.3 and 6.1 [ Table 1, Sl No. (vi) ] ref to 8 of IS 82(Residue on evaporation) |
- |
1000 |
|
- |
| Cl 3.3 and 6.1 ANNEX C [ Table 1, Sl No. (vii) ](Acidity (as CH3COOH),) |
- |
1000 |
|
- |
| Cl 3.3 and 6.1 ANNEX D [ Table 1, Sl No. (viii) ](Alkalinity) |
- |
1000 |
|
- |
| Cl 3.3 and 6.1 ANNEX E [ Table 1, Sl No. (ix) ](Permanganate test) |
- |
1000 |
|
- |
| Cl 3.3 and 6.1 ANNEX F [ Table 1, Sl No. (x) ](Alcoholic impurities) |
- |
1000 |
|
- |
| Cl 3.3 and 6.1 ANNEX A [ Table 1, Sl No. (xi) ](Benzene content) |
- |
2500 |
|
- |
| Cl 3.3 and 6.1 ANNEX A [ Table 1, Sl No. (xii) ](Methanol content) |
- |
2500 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 15 |
IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
- |
-
|
5000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(MATERIALS : CONDUCTOR) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 4.1.1(INSULATION : General Purjose Insulaiion) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 4.1.2(INSULATION : Heat Resisting Insulation) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 5.1(MATERIALS : FILLER AND INNER SHEATH) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 5.2(MATERIALS : FILLER AND INNER SHEATH) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 6.1(MATERIALS : ARMGURING) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 6.2(MATERIALS : ARMGURING) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 7.1.1(OUTER SHEATH : For Cables with General Purpose InsuIafion) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 7.1.2(OUTER SHEATH : For Cables with Heat Resisting InsuIalion) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 8.1(CONSTRUCTION : CONDUCTOR) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 8.2(CONSTRUCTION : CONDUCTOR) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 9.1(INSULATION ) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 9.2(INSULATION : Thickness of Insulation) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 9.3(INSULATION :Tolerance on Thickness of Insulation) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 9.4(INSULATION : Application of Insulation) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 10.1(CORE IDENTIFICATION) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 10.2(CORE IDENTIFICATION) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 10.3(CORE IDENTIFICATION) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 11.1(LAYING UP OF CORES) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 11.2(LAYING UP OF CORES) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 12.1(INNER SHEATH) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 12.2(INNER SHEATH) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 12.3(INNER SHEATH :Thickness of Inner Sheath) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 12.3.1(INNER SHEATH :Thickness of Inner Sheath) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.1.1(ARMOURING : Application) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.1.2(Armouring: Coverage ) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.1.3(ARMOURING : Direction of lay ) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.1.4(ARMOURING : Application) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.2(ARMOURING : Type of Armour) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.2.1(ARMOURING : Type of Armour) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.4(ARMOURING : Joints) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.5.1(ARMOURING : Resistance) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.5.2(ARMOURING : Resistance) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.6 b)(ARMOURING: Elongation ) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 13.6 g)(ARMOURING: Resistivity) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 14.1(OUTER SHEATH) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 14.2(OUTER SHEATH) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 14.3(OUTER SHEATH : Colour ) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 14.4.1(Thickness of Outer Sheath : Unarmowed Cables) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 14.4.2(Thickness of Outer Sheath : Armoured Cables) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 a) 1)(Tests on conductor : Annealing test ( for copper )) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 a) 3)(Tests on conductor : Wrapping test ( for aluminium )) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 a) 4)(Tests on conductor : Conductor resistance test) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 a) 4)(Resistance test - Neutral conductor ) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)1)(Phyaical tests for insulation : Tensile Test) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)1)(Phyaical tests for insulation : Elongation ) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)1)(Physical tests for sheath : Tensile stregth ) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)1)(Physical tests for sheath : Elongation ) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)3)(Phyaical tests for insulation : Shrinkage ) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)3)(Phyaical tests for Sheath : Shrinkage ) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)4)(Hot deformation : Insulation ) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)4)(Hot deformation : Sheath ) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)5)( Loss of mass in air oven- Insulation ) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)5)( Loss of mass in air oven- sheath ) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)6)(Heat shock test- Insulation ) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)6)(Heat shock test- sheath ) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)7)(Thermal stability- insulation ) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 d)7)(Thermal stability- Sheath ) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 e)(Insulation resistance test : IR Constant ) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 f)(High voltage test ( water immersion test )) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 g)(High voltage test at room temperature) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1 g)(High voltage test at room temperature) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.4 a)(Cold bend test- Insulation ( Optional test)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.4 a)(Cold bend test- Sheath ( Optional test)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.4 b)(Cold impact test- Insulation ( Optional test)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.4 b)(Cold impact test- Sheath ( Optional test)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.4 c)(Armour resistance test ( for other than mining cables ).- Optional test ) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 16.2(DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 16.3.1(High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 16.3.2(High Voltage Test ( Water Immersion Test ) : d.c. Test) |
- |
2000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 16.4(Flammability Test) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 16.5(Oxygen Index Test) |
- |
2000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 16.6(Flame Retardance Test on Single Cables) |
- |
1500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 16.7(Flame Retardance Test on Bunched Cables) |
- |
5000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 16.9(Test for Halogen Acid Gas Evolution) |
- |
2500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 16.1(Temperature Index) |
- |
3000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1.e(Insulation resistance Test- Insulation resistance At Maximum rated temperature temperature) |
- |
3000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1.e(Insulation resistance Test- Insulation resistance constant At Room temperature) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1.e(Insulation resistance Test- Volume Resistivity At Maximum rated temperature temperature) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 15.1.e(Insulation resistance Test- Volume Resistivity At Room temperature) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 16.4(Flammability Test- Un affected portion) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 16.4(Flammability Test- Period of Burning) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 9.3(Minimum Thickness of Reduce core insulation) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 9.2(Thickness of Reduce core insulation) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
| 3.1 Table 2
IS 8130(Number of wires in the conductor) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges, For others: Rs. 5000/- for single core unarmoured cable, Rs. 1500/- extra for each additional core, Rs. 1000/- extra for armoured cable, Rs. 10000/- for FR, Rs. 14000/- for FRLSH |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 16 |
IS 1110 (1990) |
Ferrosilicon (Bi-lingual) |
- |
-
|
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4.1, 7.2.1, 7.2.2 & 7.2.3, Table 1(Silicon- IS 1559 (Parts 1 to 7) or any other established instrumental/ chemical method) |
- |
1000 |
|
- |
| Cl. 4.1, 7.2.1, 7.2.2 & 7.2.3, Table 1(Carbon- IS 1559 (Parts 1 to 7) or any other established instrumental/ chemical method) |
- |
1000 |
|
- |
| Cl. 4.1, 7.2.1, 7.2.2 & 7.2.3, Table 1(Sulphur- IS 1559 (Parts 1 to 7) or any other established instrumental/ chemical method) |
- |
1000 |
|
- |
| Cl. 4.1, 7.2.1, 7.2.2 & 7.2.3, Table 1(Phosphorus- IS 1559 (Parts 1 to 7) or any other established instrumental/ chemical method) |
- |
1000 |
|
- |
| Cl. 4.1, 7.2.1, 7.2.2 & 7.2.3, Table 1(Aluminium- IS 1559 (Parts 1 to 7) or any other established instrumental/ chemical method) |
- |
1000 |
|
- |
| Cl. 4.1, 7.2.1, 7.2.2 & 7.2.3, Table 1(Calcium- IS 1559 (Parts 1 to 7) or any other established instrumental/ chemical method) |
- |
1000 |
|
- |
| Cl. 4.1, 7.2.1, 7.2.2 & 7.2.3, Table 1(Titanium- IS 1559 (Parts 1 to 7) or any other established instrumental/ chemical method) |
- |
1000 |
|
- |
| Cl. 4.1, 7.2.1, 7.2.2 & 7.2.3, Table 1(Boron-IS 1559 (Parts 1 to 7) or any other established instrumental/ chemical method) |
- |
1000 |
|
- |
| Cl. 4.1, 7.2.1, 7.2.2 & 7.2.3, Table 1(Zirconium- IS 1559 (Parts 1 to 7) or any other established instrumental/ chemical method) |
- |
1000 |
|
- |
| Cl. 4.1, 7.2.1, 7.2.2 & 7.2.3, Table 1(Manganese-IS 1559 (Parts 1 to 7) or any other established instrumental/ chemical method) |
- |
1000 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 17 |
IS 2202 : Part 1 (1999) |
Wooden flush door shutters (Solid Core Type) - Specification: Part 1 plywood face panels (Sixth Revision) |
- |
-
|
10500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.1(Workmanship & finish - IS 2202(Pt-1)) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.2(Workmanship & finish - IS 2202(Pt-1)) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.3(Workmanship & finish - IS 2202(Pt-1)) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.1(Height - IS 4020 (Pt-2)) |
- |
150 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.1(Width- IS 4020 (Pt-2)) |
- |
150 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.1(Thickness - IS 4020 (Pt-2)) |
- |
150 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.1(Variation in thickness - IS 4020 (Pt-2)) |
- |
150 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.1( Squareness Test - IS 4020 (Pt-2)) |
- |
150 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.2( Twist, cupping & wrapping - IS 4020 (Pt-3)) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.3(Depth of deviation - IS 4020(Pt-4)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.4(Impact Indentation Test - IS 4020(Pt-5)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.4(Depth of indentation - IS 4020(Pt-5)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.5(Deflection at maximum load - IS 4020(Pt-6)) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.5(Residual deflection - IS 4020(Pt-6)) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.6(Deflection of the edge at maximum load - IS 4020(Pt-7)) |
- |
150 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.6(Residual deflection after removal of load - IS 4020(Pt-7)) |
- |
150 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.6(Lateral buckling during loading - IS 4020(Pt-7)) |
- |
150 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.6(Residual lateral buckling - IS 4020(Pt-7)) |
- |
150 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.7(Shock Resistance Test -IS 4020(Pt-8)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.7(Shock Resistance Test -IS 4020(Pt-8)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.8(Buckling Test - IS 4020(Pt-9)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.8(Initial deflection - IS 4020(Pt-9)) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.8(Residual deformation after 15 minutes of unloading - IS 4020(Pt-9)) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.9(Slamming Test - IS 4020(Pt-10)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.1(Misuse Test - IS 4020(Pt-11)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.11(Varying Humidity Test - IS 4020(Pt-12)) |
- |
3000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.11(Maximum departure from the general planeness - IS 4020(Pt-12)) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.11(The recovery of the original size after subjecting the door to high and low humidity- IS 4020(Pt-12)) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.12(End Immersion Test - IS 4020(Pt-13)) |
- |
1500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.13(Knife Test - IS 4020(Pt-14)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.14(Glue Adhesion Test - IS 4020(Pt-15)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.15(Screw Withdrawal Resistance test - IS 4020 (Pt-16)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.15(Screw Withdrawal Strength - IS 4020 (Pt-16)) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 18 |
IS 4985 (2000) |
Unplasticized pvc pipes for potable water supplies - Specification (Third Revision) |
- |
-
|
28000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11.2(Resistance to External Blows at 0°C) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.1.1(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Plumbing pipes) |
- |
10000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Integral Sealing Ring
Sockets) |
- |
10000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)-for Integral Sealing Ring
Sockets) |
- |
10000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
10000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)) |
- |
10000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 10.6(PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 10.5(PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 10.4(PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
1200 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 10.2(PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
700 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 10.1.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.1(PIPE ENDS) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 8(SEALING RINGS) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.2.1.2-Table 4(DIMENSIONS-Sockets for elastomeric sealing ring joints-Socket inner Diameter) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.2.1.2(a)-Table 5(DIMENSIONS-Sockets for elastomeric sealing ring joints-Minimum depth of engagement) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Maximum)) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Minimum)) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Minimum Length) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.2.1(DIMENSIONS-Socket) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.1.2.1(DIMENSIONS-PIPE-Average Thickness) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.1.1.2(DIMENSIONS-PIPE-Ovality (Maximum)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Maximum)) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. Variation) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Mamimum)) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Minimum)) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7(DIMENSIONS-PIPE-Nominal Diameter) |
- |
0 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 5(CLASSIFICATION OF PIPES) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause 10.7(Sulphated Ash Content) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 19 |
IS 1165 (2002) |
Milk Powder (Bi-lingual) |
- |
-
|
- View breakup
Rs.7500.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
17 Jun, 2024 |
- - |
| 20 |
IS 4246 (2002) |
Domestic gas stoves for use with liquefied petroleum gases - Specification (Fifth Revision) |
- |
-
|
9800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5 and 5 of IS 5116 .(IS 5116) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 5 and 5 of IS 5116 .(All copper and copper alloy parts shall pass mercurous nitrate test .) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 5 and 5 of IS 5116 .(IS 5116) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 5 and 5 of IS 5116 .(IS 5116) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 5 and IS 5116 .Surface of Glass Or Glass Ceramic(IS 5116) |
- |
250 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| IS 5116 .(Toughened glass shall fragment into small particles.) |
- |
500 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| IS 5116 .(The number of glass fragments contained in a square of side 50mm located in the area of the largest pieces shall be at least 40 numbers. (Test Method as per Cl.15.2)) |
- |
500 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 6 , DESIGN FOR MAINTENANCE(Cl 6.1) |
- |
150 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 6.2(The parts of burner shall not become disconnected during operation of appliance.the centers of adjoining burner shall not be less than 180 mm.) |
- |
150 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 7(Cl 7) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 4.1 of IS 5116(General) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 4.1.1(General) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 4.2 of IS 5116(General) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 5 (5.1 of IS 5116)(Materials) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 5 (5.1.1 of IS 5116)(Materials) |
- |
250 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 5 (5.2 of IS 5116)(Materials) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 5 (5.3 of IS 5116)(Materials) |
- |
200 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 5 (5.4 of IS 5116)(Materials) |
- |
300 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 5 (5.5 of IS 5116)(Materials) |
- |
200 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 5 (5.7 of IS 5116)(Materials) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 5.1 of IS 4246(Materials) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 6.1(Mechanical (Design for Maintenance)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 6.2(Mechanical (Design for Maintenance)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 6.3(Mechanical (Design for Maintenance)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 6.4(Mechanical (Design for Maintenance)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 6.5(Mechanical (Design for Maintenance)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 6.6(Mechanical (Design for Maintenance)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 7(Rigidity and Stability) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 8.1 (7.1 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 8.1 (7.2 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 8.1 (7.3 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 8.1 (7.3.1 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 8.1 (7.3.2 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 8.1 (7.3.3 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 8.1 (7.4.1 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 8.1 (7.4.2 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 8.1 (7.5 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 8.1 (7.6 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 8.1 (7.7 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 8.2(Mechanical (Workmanship and Finish)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 8.3(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 9 (8.1 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 9 (8.2 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 9 (8.3 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 9 (8.4 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 9 (8.5 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 9 (8.5.1 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 9 (8.6 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 9 (Cl 8.7 of IS 5116 )(Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(A 1.1 Min) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 9 (Cl 8.7 of IS 5116 )(Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(B 0.4 Min)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 9 (Cl 8.7 of IS 5116 )(Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(C 3.0 Min)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 9 (Cl 8.7 of IS 5116 )(Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(D 2.80 Min)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 9 (Cl 8.7 of IS 5116 )(Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(A1 1.2 Min)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 9 (Cl 8.7 of IS 5116 )(Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(B1 0.4 Min)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 9 (Cl 8.7 of IS 5116 )(Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(C1 3.0 Min)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 9 (Cl 8.8 of IS 5116 )(All controls or taps shall be easy to operate
at all temperatures normally attained in use.) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 9 (Cl 8.9 of IS 5116 )(Screws, nuts, etc, which regulate the
tension of taps valve or springs, shall not loosen
in operation of the appliance. It shall not be
possible to cause a leak during normal manual
operation of tap.) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 9 (Cl 8.10 of IS 5116 )(Screw-down valves shall be so designed
that it is impossible to withdraw completely the
valve stem in the normal operation of the tap.) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 9 (Cl 8.11 of IS 5116 )(Taps having an 'OFF' position shall have
positive stops at the 'OFF' and simmer position
except that special purpose taps (for appliance
incorporating auto or self ignition device), for
example, taps with simmering position in
between 'OFF' and 'ON' may have a movement
beyond the simmer position with a positive stop) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 9 (Cl 8.11.1 of IS 5116 )(Simmer flame shall be obtained by fixed
simmer orifice.) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 9 (8.12 of IS 5116)(Mechanical (Workmanship and Finish)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 10 (cl 9.1 of 1S 51 I6 )(The injector Jets shall be fixed calibrated
type and it shall not be possible to loosen them
without the use of tools. The dimensions of the
injector Jet shall conform to the following
requirements:
Across flats
6 mm. nominal
M 5 or 1BA) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 10 (cl 9.1 of 1S 51 I6 )(Projection from the face
of mounting) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 10 (cl 9.1 of 1S 51 I6 )(Threads
6 mm, Min) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 10 (cl 9.1.1 of 1S 51 I6 )(Injector Jet shall be made of metal, with or
without ceramic tip. The melting point of the
metal shall not be less than 650°C.) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 10 (cl 9.2 of 1S 51 I6 )(The size of the Jet in litres per hour of flow
of LPG at STP conditions shall be impressed
upon it.) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 11 (cl 10.1 of 1S 51 I6 )(The construction of the burners and the
assembly shall allow their dismantling from
the supports easily with or without the use of
tools (see Fig. 5 for guidance).) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 11 (cl 10.2 of 1S 51 I6 )(The burner supports shall be rigid and
shall be fixed in their place. Their construction
shall ensure the stability of the burners and
shall prevent their undue movement in a
horizontal plane.) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 11 (cl 10.3 of 1S 51 I6 )(The lightness of the joints in the burner
assembly shall not depend upon adhesives or any kind ot packmg) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 11 (cl 10.4 of 1S 51 I6 )(If primary air regulators are used, they
shall be so designed that they are not easily
maladjusted by the user and the construction
shall be such that primary air adjustment can
be made with the burner in place ( see Fig. 6 ).) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 11 (cl 10.5 of 1S 51 I6 )(If the burner is made and assembled in
two or more parts they shall be so designed to
provide proper self-locating arrangement so
that they are always re-assembled to its
original design preventing any maladjustment
in their assembly. This shall also be applicable
for primary air regulators.) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 11.2(For burners having centre flame,provision shall be made to protect the centre flame from pans resting directly on burner top and smothering the centre flame.) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 11 .3(The stove comprising two or more burners shall include one burner having a rating of at least 1490 kcal/h, based on net calorific value of the gas ( when using commercial butane).) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 12.1(The design of the pan supports shall be such that
it is practicable to support a pan of 100mm diameter,
over at least one top burner without the use of loose
rings, and such that 125 mm diameter vessel remains
stable over each burner. Prongs of the support shall
have suitable taper to accommodate round bottom
pans.) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 12.1.1(Loose pan supports shall be so designed that
it is not possible to place them firmly in other than
proper position.) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 13.1 (Cl 16 OF IS 5116)(All gas carrying parts of the appliance shall be
sound and these parts when connected, to form
a complete assembly shall also be soundagainst any gas leakage. The complete
assembly shall also be sound against any gas
leakage. The complete assembly shall be
checked at 14.71 kN/m2 (approx 150 gf/cm2).
The details of test are given in Annex J.) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 13.2 .1(The stove may be provided with a gas leak
indicator. If gas leak indicator is provided, it shall
conform to the requirements of IS 13432 (Part 1) or
IS 13432 (Part 2).) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 14.1 (18.1 of IS 5116)(Mechanical (Gas Inlet Connection)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 14.1(Cl 18.2 of IS 5116)(Where nozzles for flexible tubing are
fitted, they shall be so positioned as to facilitate
fitting of the tubing and also to prevent heating
of the tubing to more than 60°C. Shape of
nozzles is given in Fig. 7.) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 14.1 (18.2 of IS 5116)(Mechanical (Gas Inlet Connection)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 14.1 (18.2 of IS 5116)(Mechanical (Gas Inlet Connection)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 14.1 (18.2 of IS 5116)(Mechanical (Gas Inlet Connection)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 14.1 (18.2 of IS 5116)(Mechanical (Gas Inlet Connection)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 14.1 (18.2 of IS 5116)(Mechanical (Gas Inlet Connection)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 14.1 (18.2 of IS 5116)(Mechanical (Gas Inlet Connection)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 14.1(Cl 18.3 of IS 5116)(Screwed gas inlet and outlet connections
shall have threads specified in 17.3.) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 14.1(Cl 18.4 of IS 5116)(The pipe/tube used for main gas rail shall
be of mild steel. The wall thickness of main gas
rail shall be 1.6 mm + no Iimit/–0.15 mm.) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 14.1(Cl 18.4 of IS 5116)(The
external surface of the gas rail shall be treated
to resist corrosion.) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 14.1 (18.4 of IS 5116)(Mechanical (Gas Inlet Connection)) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 14.2(The position of the gas inlet shall allow
connection to a gas supply on either side of the
appliance. Inlet connection at the rear is also
permitted. It shall be possible to change gas inlet from
one side to other side easily by standard tools.) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl.15(When tested as specified in Annex C, the vertical
resultant deflection of the top surface measured at the
centre of length of the body, shall not exceed 2 mm
and the distance between the opposite sides
(lengthwise and widthwise) shall not change by more
than 5 mm.) |
- |
200 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 17.1(Each burner assembly under separate ‘ON/OFF’
control shall give + 8 percent of the manufacturers’
specified gas consumption in I/h or heat input in
kcaVh at 2942 kN/m2 (30 gf/cmz)) |
- |
150 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 17.1.2(Gas Consumption) |
- |
150 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl17.2.1(It shall be possible to reduce the consumption
rate of the burner to the following extent by providing
a fixed simmer orifice in the gas tap:
a) For burners up to 60 I/h gas rate, 35 percent
of the rated capacity; and) |
- |
150 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl17.2.1(b) For burners above 60 I/h gas rate, 22 I/h or 26
percent of the rated capacity whichever is
higher.) |
- |
150 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl17.2.2(When the gas consumption of a burner is
reduced to simmer as described in 17.2, the flame shall
not extinguish, blow off, strike back or form soot when
tested with commercial LPG at 2942 kN/m2
(30 gf/cm2) gas inlet pressure.) |
- |
150 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| cl 18.1(There shall be easy and safe access for lighting
and relighting each burner by a match stick and it
shall be easy to see that the burner is lighted. Where) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| cl 18.1(the burner or burners are lighted by automatic ignition
(battery of flint-operated) or by a pilot flame, it shall
not be possible for gas to be admitted to the main
burner without being smoothly ignited by the pilot
flame. Each burner should be at room temperature at
the beginning of the test and should be tested in turn) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| cl 18.2(If a flame is applied to any of the outer row of the
burner ports when the gas is flowing, flame travel shall
be complete. This applies for the all pressures from
2452 to 3432 kN/m2 (25 to 35 gf/cm2), taps being
fully opened and without a pan over the burner.) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl18.3(When the burner is ignited from a pilot flame
and / or by an electric/electronic method, the ignition
and flame travel shall be smooth at pressure from
2452 kN/m2 to 3432 kN/m2 (25 gf/cm2 to 35 gf/cm2)
with the burner tap turned full ‘ON’ and ignition shall
be effected without undue delay after turning on taps) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl18.4 (Cl14 of IS 5116)(Shall prevent gas from being supplied to
the main burner until the pilot flame, if
provided, is established;) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl18.4 (Cl14 of IS 5116)(Shall, after flame failure, stop all gas flow
to the main burner;) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl18.4 (Cl14 of IS 5116)(Shall be actuated only by a pilot flame, if
provided, to ignite the main burner
without failure or delay;) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl18.4 (Cl14 of IS 5116)(Shall open and close in times not
exceeding the following limits:Opening from cold
Closing from the
fully heated
condition
Time
Manually Non-manually
Operated, Operated,
seconds seconds
40 90
75 90) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl18.4 (Cl14 of IS 5116)(Shall be free from any weakness in design
which will give rise to failure to danger; and) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl18.4 (Cl14 of IS 5116)(Shall be protected against adjustment by
unauthorized persons.) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 18.4 (14.2 of IS 5116)(Ignition and Flame travel) |
- |
50 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 19.1(It shall be possible to operate the appliance with
taps fully open at gas inlet pressure from 2452 kN/m2
to 3432 kN/m2 (25 gflcmz to 35 gf/cm2) without the
flame extinguishing, blowing off or striking back and
without the formation of soot) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 19.1.1(When the gas consumption of a burner is
reduced to simmer after operating for half an hour at
full ‘ON’, the flame shall not extinguish, blow off,
strike back or form soot when tested with commercial
LPG at 2942 kN/m2 (30 gf/cm2) gas inlet pressure.) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 19.2(Pilot flames shall be stable, without lifting
or soot deposition, at gas inlet pressure from
2 452kN/m2to3432 kN/m2 (25 gf/cm2 to 35 gf7cm2).) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl19.3(The fixed minimum pilot rate shall be sufficient
to relight the main burnerat2452 kN/m2 (25 gf/cm2)
gas inlet pressure.) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl.20(The ignition of the burner flames, their operation and
turning ‘OFF’ shall not give rise to undue or excessive
noise during all the operations.) |
- |
150 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 21(Flash Back) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl 22(A vessel, 150 mm diameter, full of water, shall
be placed on the burner and the burner lighted at ‘ON’
position of the tap for one hour. After the test, no soot
(unburned carbon) shall be deposited on the burner
and on the bottom of the vessel. This applies for all
pressures from 2452 kN/m2 to 3432 kNlm2
(25 gf/cm2 to 35 gf/cm2)) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl.23(There shall be no extinction of the flames on any
of the burners operating at maximum consumption
when the appliance is placed in a general (not
localized) current of air with a velocity of 2 m/s, as
measured with a rotating vane anemometer. The
location of the appliance relative to neighboring walls
and the direction of the draught shall be varied to
correspond to likely conditions of appliance installation.
This applies for all pressures from 2452 kN/m2 to
3432 kN/m2 (25 gf/cm2 to 35 gf/cm2).) |
- |
150 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| Cl.24(Annexure E)(on no account the carbon monoxidel
carbon dioxide ratio of the exhaust gases of any burner.
operating at any consumption at which the burner is
stable at gas inlet pressure from 2452 kN/m2 to
3432 kN/m2 (25 gf/cm2 to 35 gf/cm2), exceed 0.02.) |
- |
250 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 24 (Annex - E)(Combustion (CO and CO2 ratio)) |
- |
250 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 25.1 ( 23.1 of IS 5116 )(Fire Hazard and Limiting Temperatures) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 25.1 ( 23.2 of IS 5116 )(Fire Hazard and Limiting Temperatures) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 25.1 ( 23.2.1 of IS 5116 )(Fire Hazard and Limiting Temperatures) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 25.1 ( 23.2.2 of IS 5116 )(Fire Hazard and Limiting Temperatures) |
- |
100 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 25.2(Fire Hazard and Limiting Temperatures) |
- |
200 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 26 (for burner 1)(Thermal Efficiency) |
- |
500 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 26 (for burner 2)(Thermal Efficiency) |
- |
1200 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 26 (for burner 3)(Thermal Efficiency) |
- |
1200 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 26 (for burner 4)(Thermal Efficiency) |
- |
1200 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
| 26 (for burner 5)(Thermal Efficiency) |
- |
1200 |
|
For BIS Samples: 1.5 times of BIS testing charges, For other: Rs. 9800/-, Rs. 1200/- extra for each additional burner. |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 21 |
IS 1239 : Part 1 (2004) |
Steel Tubes, Tubulars and Other Wrought Steel Fittings : Part 1 Steel Tubes (BI-LINGUAL) |
- |
-
|
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause - 6.1.1, Table-1( CARBON) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause - 6.1.1, Table-1(SULPHUR) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause - 6.1.1, Table-1(PHOSPHURS) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause - 6.1.1, Table-1(MANGANESE) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause - 6.1.1, Table-1(NITROGEN) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause - 6.1.1, Table-1(SILICON) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Clause - 6.1.1, Table-1( ALUMINIUM) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 12 AND AS PER IS 4736(MASS OF ZINC COATING) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 12 AND AS PER IS 4736(UNIFORMITY OF ZINC COATING) |
- |
750 |
|
For BIS samples: 1.5 times of BIS testing charges |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 22 |
IS 1659 (2004) |
Block boards - Specification (Fourth Revision) |
- |
-
|
9500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.3(Dimensional Requirements - Length - 8.1.4) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.3(Dimensional Requirements - Width - 8.1.4) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.3(Dimensional Requirements - Thickness - Annexure E) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.3(Dimensional Requirements - Edge Straightness - Annexure D) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.3(Dimensional Requirements - Squareness - Annexure D) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.3(Dimensional Requirements - Variation in thickness - Annexure E) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.2.1(Dimensional Changes caused by humidity - Change in Length - at 90% RH - Annexure F) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.2.1(Dimensional Changes caused by humidity - Change in Length - at 40% RH - Annexure F) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.2.1(Dimensional Changes caused by humidity - Change in Thickness - at 90% RH - Annexure F) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.2.1(Dimensional Changes caused by humidity - Change in thickness - at 40% RH - Annexure F) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.2.1(Dimensional Changes caused by humidity - Delamination - Annexure F) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.2.1(Dimensional Changes caused by humidity Change in local planeness - Annexure F) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.2.2 (Resistance to water - Annexure G, Annexure H [For BWP grade]) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.2.2 (Resistance to water - Annexure G, Annexure H [For MR Grade]) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.2.3(Adhesion of Plies - Annexure H) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.2.4(Mycological Test [for MR grade only] - Annexure J) |
- |
3000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.2.5(Modulus of rupture - AVERAGE - Annexure K) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.2.5(Modulus of rupture - MINIMUM INDIVIDUAL - Annexure K) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.2.5(Modulus of elasticity - AVERAGE - Annexure K) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.2.5(Modulus of elasticity - MINIMUM INDIVIDUAL - Annexure K) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 9.2.6(Spot test - Annexure L) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 23 |
IS 14151 : Part 2 (2008) |
Irrigation equipment - Sprinkler pipes - Specification: Part 2 quick coupled polyethylene pipes and fittings (Second Revision) |
- |
-
|
22000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| C. 4.1.1.1.1, IS 617-1994, Cl. 5, Table-1 , Desig 4600(Aluminium Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 55000(Aluminium Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 53000(Aluminium Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 52000(Aluminium Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 51300(Aluminium Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 40800(Aluminium Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31500 (Aluminium Content) |
- |
500 |
|
- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31000 (Aluminium Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 617-1994, Cl. 5, Table-1 , Desig 4600(Silicon Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 55000(Silicon Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 53000(Silicon Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 52000(Silicon Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 51300(Silicon Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 40800(Silicon Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31500 (Silicon Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31000 (Silicon Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.2, IS 513 (P-1)-2016, Cl. 7.3, Table-3 , Grade O (CR1)(Carbon Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.2, IS 513 (P-1)-2016, Cl. 7.3, Table-3 , Grade O (CR1)(Manganese Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.2, IS 513 (P-1)-2016, Cl. 7.3, Table-3 , Grade O (CR1)(Sulphur Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.2, IS 513 (P-1)-2016, Cl. 7.3, Table-3 , Grade O (CR1)(Phosphorous Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.2, IS 513 (P-1)-2016, Cl. 7.3, Table-3 , Grade O (CR1) Al-Si-Killed(Silicon Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.2, IS 513 (P-1)-2016, Cl. 7.3, Table-3 , Grade O (CR1) Si-Killed(Silicon Content) |
- |
500 |
|
--- |
| Cl. 4.1.1.2.1, IS 14151 (P-1)-1999, Cl. 4, IS 2530-1963, Cl. 16(Carbon Black Dispersion) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 617-1994, Cl. 5, Table-1 , Desig 4600(Magnesium Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 55000(Magnesium Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 53000(Magnesium Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 52000(Magnesium Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 51300(Magnesium Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 40800(Magnesium Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31500 (Magnesium Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31000 (Magnesium Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 617-1994, Cl. 5, Table-1 , Desig 4600(Iron Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 55000(Iron Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 53000(Iron Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 52000(Iron Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 51300(Iron Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 40800(Iron Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31500 (Iron Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31000 (Iron Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 617-1994, Cl. 5, Table-1 , Desig 4600(Manganese Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 55000(Manganese Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 53000(Manganese Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 52000(Manganese Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 51300(Manganese Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 40800(Manganese Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31500 (Manganese Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31000 (Manganese Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 617-1994, Cl. 5, Table-1 , Desig 4600(Zinc Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 55000(Zinc Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 53000(Zinc Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 52000(Zinc Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 51300(Zinc Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 40800(Zinc Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31500 (Zinc Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31000 (Zinc Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 617-1994, Cl. 5, Table-1 , Desig 4600(Titanium Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 55000(Titanium Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 53000(Titanium Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 52000(Titanium Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 51300(Titanium Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 40800(Titanium Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31500 (Titanium Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31000 (Titanium Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 55000(Chromium Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 53000(Chromium Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 52000(Chromium Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 51300(Chromium Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 40800(Chromium Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31500 (Chromium Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31000 (Chromium Content) |
- |
500 |
|
---- |
| C. 4.1.1.1.1, IS 617-1994, Cl. 5, Table-1 , Desig 4600(Copper Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 55000(Copper Content) |
- |
500 |
|
-- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 53000(Copper Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 52000(Copper Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 51300(Copper Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 40800(Copper Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31500 (Copper Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31000 (Copper Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 617-1994, Cl. 5, Table-1 , Desig 4600(Lead Content) |
- |
500 |
|
--- |
| C. 4.1.1.1.1, IS 617-1994, Cl. 5, Table-1 , Desig 4600(Tin Content) |
- |
500 |
|
--- |
| 4.1 .3(Workmanship and Appearance) |
- |
500 |
|
--- |
| 4.1.4(b)(Holding Attachments for Coupler Parts) |
- |
1000 |
|
- |
| 4.1.5(Rubber Ring) |
- |
500 |
|
-- |
| 4.2.3(Quick Coupled ~pe HDPE Fittings) |
- |
500 |
|
-- |
| 6.1.1, 6.1.1.1(Leakage Test) |
- |
1000 |
|
--- |
| 6.1.2, 6.1.2.1( Hydraulic Proof Test) |
- |
1000 |
|
---- |
| 6.1.3, 6.1.3.1(Weldability Test) |
- |
2000 |
|
--- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 24 |
IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
- |
-
|
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Annealing test (for copper)) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 4.1(Tensile test (for Al)-Before Stranding) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 4.1(Tensile test (for Al)- After Stranding) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 4.1(Wrapping test (for Al)) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 4.2(Conductor resistance test) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 10.11(Per sulphate test (for tinned Cu cable only)) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 9(Overall dimensions) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 9.1(Ovality) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 5.3(Thickness of Insulation) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 5.2(Application ) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 8.3(Thickness of Sheath) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) c) 1)(Tensile strength (Without ageing)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) c) 1)(Elongation (Without ageing)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) c) 3)(Tensile strength (After ageing)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) c) 3)(Elongation (After ageing)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) c) 3)(TS variation) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) c) 3)(Elongation variation) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) d) 1)(Sheath -Tensile strength (Without ageing)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) d) 1)(Sheath- Elongation (Without ageing)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) d) 3)(Sheath- Tensile strength (After ageing)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) d) 3)(Sheath- Elongation (After ageing)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) d) 3)(Sheath- TS variation) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) d) 3)(Sheath- Elongation variation) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) c) 2)(Loss of mass- Insulation ) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) d) 2)(Loss of mass- Sheath ) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) c) 4)(Shrinkage-Insulation) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) c) 4)(Cracks Observed) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) d) 4)(Shrinkage- Sheath ) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) d) 4)(Cracks Observed) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) c) 5)(Heat shock-Insulation ) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) d) 5)(Heat shock-Sheath ) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) c) 6)(Hot deformation - Indentation depth- Insulation) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) d) 6)(Hot deformation -Indentation depth - Sheath ) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) c) 7)(Thermal stability- Insulation ) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) d) 7)(Thermal stability- Sheath ) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1(Category Code) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) c) 8)(Cold bend for insulation) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) c) 9)(Cold impact for insulation) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) d) 8)(Cold bend for sheath) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 1 iii) d) 9)(Cold impact for sheath) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 10.5(Oxygen index) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 10.7(Temperature index) |
- |
3000 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 10.6(Halogen evolution) |
- |
5000 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 10.8(Smoke density rating) |
- |
3000 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 10.1(HV (water immersion)) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 10.1(HV (water immersion)) |
- |
1500 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 10.2(HV (room temperature)) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| table 1 e) 3) (Volume Resistivity - Room temp ) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| table 1 e) 3) (IR constant- Room temp ) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| table 1 e) 3) (IR constant- max. Temp) |
- |
200 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 10.4(Flammability test-Burning after flame removal) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 10.4(Flammability test- Unaffected portion) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 10.9(Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 11(Identification) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 11.1(Durability) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 11.2(Legibility) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 13(Cable code) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| (Cl.6.1.3 of IS 8130:2013)(Flexible Conductors (Classes 5)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| (Cl.6.1.3 of IS 8130:2013)( Flexible Conductors (Classes 5)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| (Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors(Class-2)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| (Cl.6.1.3 of IS 8130:2013)(Stranded compacted circular conductors and shaped conductors (Class 2)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| (Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors (Class-2)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| (Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors (Class-2)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| (Cl.6.1.3 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| (Cl.6.1 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| (Cl.6.1 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| (Cl.16.1)
(Cl.19.1)(Conductor- Diameter ) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| (Cl.16.1)
(Cl.19.1)(Conductor) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| (Cl.16.1)
(Cl.19.1)(Conductor) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| (Cl.16.1)
(Cl.19.1)(Conductor) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| (Cl. 18.1.3)
(Cl. 19.1.4)
(Cl. 20.1.3)
(Cl. 21.1.3)
(Cl. 22.1.3)(Assembly of cores ) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 12(CONSTRUCTION Core Identification) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 8.1(Sheath Material ) |
- |
100 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 7(Binder Tape) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 6.2(Filler) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 6.1(Filler) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 5.1(Insulation) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 4.4(Joints in Conductor) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 4.4(Joints in Conductor) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 4.1(Conductor - Material) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 4.1(Conductor - Material) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 4, IS 8130(Construction of conductor) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 2, IS 8130(No fo wire in a conductor) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 8.3(Minimum thickness of Sheath) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 8.3(Avarage thickness of Sheath) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 5.3(Minimum thickness of insulation) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| 5.3(Avarage thickness of insulation) |
- |
50 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
| Table 4(Copper purity test) |
- |
4000 |
|
For BIS samples: 1.5 times of BIS testing charges. For others: Rs. 10000/- for single core, Rs. 1000/- for each additional core, Rs. 10000/- for FR, Rs. 14000/- for FRLSH. |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 25 |
IS 12818 (2010) |
Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) |
- |
-
|
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1 (Ref. 3.4.1. of IS 10151)(Composition - The monomer content (VCM content) in the
resin - Annex A ofIS 10151) |
- |
500 |
|
- |
| 4.1.2 (Ref. Cl 5.1. of IS 4669)(Composition - Loss on heating ) |
- |
500 |
|
- |
| 4.1.2 (Ref. Cl 11 of IS 4669)(Composition -Sulphated ash content ) |
- |
1000 |
|
- |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Nominal Diameter) |
- |
100 |
|
- |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Mean Outer Diameter of Pipe) |
- |
100 |
|
- |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Outer Diameter at any point ) |
- |
100 |
|
- |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Mean Outer Diameter over Connection) |
- |
100 |
|
- |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Wall thickness) |
- |
100 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(DIMENSIONS - Casing Pipes) |
- |
100 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Nominal Diameter) |
- |
100 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Mean Outer Diameter of Pipe, Min) |
- |
100 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Mean Outer Diameter of Pipe , Max) |
- |
100 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Outer Diameter at any point , Min) |
- |
100 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Outer Diameter at any point, Max) |
- |
100 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Mean Outer Diameter over Connection) |
- |
100 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Wall thickness, Min) |
- |
100 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Wall thickness, Max) |
- |
100 |
|
- |
| 7.3.1(No.of Ribs) |
- |
100 |
|
- |
| 7.3.2(Rib height) |
- |
100 |
|
- |
| 7.4 Table 8 & 9
Fig 1(Effective length, l2) |
- |
100 |
|
- |
| 7.4 Table 8 & 9
Fig 1(Segmental length, l3) |
- |
100 |
|
- |
| 7.4 Table 8 & 9
Fig 1(Segmental length, l4) |
- |
100 |
|
- |
| 7.4 Table 8 & 9
Fig 1(Segmental length, l5) |
- |
100 |
|
- |
| 7.5 and Table 10
Fig 2A & 2B(Summation of slot lengths over internal circumference of the cross- section.) |
- |
100 |
|
- |
| 7.5 and Table 10
Fig 2A & 2B(Minimum number of slots on the circumference of the cross-section.) |
- |
100 |
|
- |
| 7.5 and Table 10
Fig 2A & 2B(Approximate Free Passage Area, in Percent (Mean Value) for Width of Slot (w)) |
- |
100 |
|
- |
| 8.1 to 8.3 and Table 11 &12
Fig 3A & 4A(THREADING OF SCREEN ANDCASING PIPES.
IS 554.) |
- |
100 |
|
- |
| 8.1 to 8.3 and Table 11 &12
Fig 3A & 4A(THREADING OF SCREEN ANDCASING PIPES.
IS 554.) |
- |
100 |
|
- |
| 8.4(Sealing rings - Hardness) |
- |
300 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
100 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
100 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
100 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
100 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
100 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
100 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
100 |
|
- |
| 9.1(Visual Appearance) |
- |
300 |
|
- |
| 9.2(Internal Diameter) |
- |
500 |
|
- |
| 9.3(Density
IS 12235 (Part 14)) |
- |
1000 |
|
- |
| 9.4 and Table 14(Resistance to External Blows at 0 ?C
IS 12235 (Part 9)) |
- |
1000 |
|
- |
| 9.5(Tensile Strength
IS 12235(Part 13)) |
- |
1500 |
|
- |
| 9.6(Vicat Softening Temperature
IS 12235 (Part 2).) |
- |
1000 |
|
- |
| 9.7(Effect on Water
a) Lead (first extraction)
b) Lead (Third extraction)
c) Dialkyl Tin C4 & higher homologues measured as Tin (Third extraction)
d) Cadmium (All three extracts)
e) Mercury (All three extracts)
f) Other Toxic Substances
) |
- |
2000 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 26 |
IS 13334 : Part 1 (2014) |
Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) |
- |
-
|
8150 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.6(Listeria monocytogenes) |
- |
500 |
|
- |
| 5.6(Spore count, Anaerobic (Sulfite reducing Clostridia)) |
- |
250 |
|
- |
| 5.6(Spore count, Aerobic (Bacillus cereus)) |
- |
250 |
|
- |
| 5.6(Salmonella) |
- |
500 |
|
- |
| 5.6(Coagulase positive Staphylococcus aureus) |
- |
500 |
|
- |
| 5.6(Escherichia coli) |
- |
500 |
|
- |
| 5.6(Coliform count ) |
- |
500 |
|
- |
| 5.6(Bacterial count) |
- |
500 |
|
- |
| 5.6(Scorched particles) |
- |
550 |
|
- |
| 5.6(Titratable acidity (lactic acid)) |
- |
550 |
|
- |
| 5.6(Total ash (on dry basis)) |
- |
550 |
|
- |
| 5.6(Insolubility index) |
- |
550 |
|
- |
| 5.6(Milk fat) |
- |
550 |
|
- |
| 5.6(Milk protein in milk solids not fat) |
- |
500 |
|
- |
| 5.6(Moisture) |
- |
500 |
|
- |
| 5.2(Absence of extraneous matter, added colour and added flavour) |
- |
300 |
|
- |
| 4(Description) |
- |
300 |
|
- |
| Cl 5.4(The flavour of the product or of the reconstituted
milk shall be pleasant and clean (see IS 10030).) |
- |
300 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 27 |
IS 513 : Part 1 (2016) |
Cold reduced carbon steel sheet and strip: Part 1 cold forming and drawing purpose (Sixth Revision) |
- |
-
|
14000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.0(CARBON) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.0(SULPHUR) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.0(PHOSPHORUS) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.0(MANGANESE) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.0(SILICON) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.0(NITROGEN) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.0(ALUMINIUM) |
- |
400 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 7.0(MICRO ALLOYS) |
- |
3200 |
|
For BIS samples: 1.5 times of BIS testing charges |
| 8(Mechanical and Physical Properties) |
- |
7150 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl 9.5(Workmanship) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl 9.6(Workmanship) |
- |
300 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl 10(Workmanship) |
- |
250 |
|
For BIS samples: 1.5 times of BIS testing charges |
| Cl 11(Length, Width & Thickness) |
- |
500 |
|
For BIS samples: 1.5 times of BIS testing charges |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 28 |
IS 14543 (2016) |
Packaged drinking water (Other Than Packaged Natural Mineral Water) - Specification (Second Revision) |
- |
-
|
18000 View breakup
Rs.18000.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.4 i)(Dieldrin) |
- |
125 |
|
N.A. |
| 5.4 i)(Aldrin) |
- |
125 |
|
N.A. |
| 5.4 i)(Malaoxon) |
- |
250 |
|
N.A. |
| 5.4 i)(Malathion) |
- |
250 |
|
N.A. |
| 5.4 i)(Methyl Paraoxon) |
- |
250 |
|
N.A. |
| 5.4 i)(Methyl Parathion) |
- |
250 |
|
N.A. |
| 5.4 i)(Atrazine) |
- |
250 |
|
N.A. |
| 5.4 i)(Alachlor) |
- |
250 |
|
N.A. |
| 5.4 i)(Isoproturon) |
- |
250 |
|
N.A. |
| 5.4 i)(Butachlor) |
- |
250 |
|
N.A. |
| 5.4 i)(2,4-D) |
- |
250 |
|
N.A. |
| 5.4 i)(phorate sulphone) |
- |
250 |
|
N.A. |
| 5.4 i)(Phorate sulphoxide) |
- |
250 |
|
N.A. |
| 5.4 i)(Phorate) |
- |
250 |
|
N.A. |
| 5.4 i)(Chlorpyrifos) |
- |
250 |
|
N.A. |
| 5.4 i)(Ethion) |
- |
250 |
|
N.A. |
| 5.4 i)(Monocrotophos) |
- |
250 |
|
N.A. |
| 5.4 i)(Endosulfan Sulphate) |
- |
83 |
|
N.A. |
| 5.4 i)(beta-Endosulfan) |
- |
83 |
|
N.A. |
| 5.4 i)(alpha-Endosulfan) |
- |
83 |
|
N.A. |
| 5.4 i)(Delta-HCH) |
- |
83 |
|
N.A. |
| 5.4 i)(beta-HCH) |
- |
83 |
|
N.A. |
| 5.4 i)(alpha-HCH) |
- |
83 |
|
N.A. |
| 5.4 i)(Gamma-HCH (Lindane)) |
- |
250 |
|
N.A. |
| 5.4 i)(p,p DDD) |
- |
42 |
|
N.A. |
| 5.4 i)(o,p DDD) |
- |
42 |
|
N.A. |
| 5.4 i)(p,p DDE) |
- |
42 |
|
N.A. |
| 5.4 i)(o,p DDE) |
- |
42 |
|
N.A. |
| 5.4 i)(p,p DDT) |
- |
42 |
|
N.A. |
| 5.4 i)(o,p DDT) |
- |
42 |
|
N.A. |
| 5.3 Table-3 ix
(Polynuclear aromatic hydrocarbons) |
- |
350 |
|
N.A. |
| 5.3 Table-3 viii
(Polychlorinated biphenyle (PCB)) |
- |
350 |
|
N.A. |
| 5.3 Table-3 vii
(Nickel (as Ni)) |
- |
200 |
|
N.A. |
| 5.3 Table-3 vi(Chromium (as Cr)) |
- |
200 |
|
N.A. |
| 5.3 Table-3 v
(Lead (as Pb)) |
- |
200 |
|
N.A. |
| 5.3 Table-3 iv
(Cyanide (as CN)) |
- |
250 |
|
N.A. |
| 5.3 Table-3 iii
(Arsenic (as As)) |
- |
200 |
|
N.A. |
| 5.3 Table-3 ii
(Cadmium (as Cd)) |
- |
200 |
|
N.A. |
| 5.3 Table-3 i
(Mercury (as Hg)) |
- |
200 |
|
N.A. |
| 5.3 Table-2 xxiv
(Borates (as B)) |
- |
100 |
|
N.A. |
| 5.3 Table-2 xxiii
(Antimony (as Sb)) |
- |
200 |
|
N.A. |
| 5.3 Table-2 xxii
(Sulphide (as H2S)) |
- |
100 |
|
N.A. |
| 5.3 Table-2 xxi
(Anionic surface active agents (as MBAS)) |
- |
100 |
|
N.A. |
| 5.3 Table-2 xx
(Mineral oil) |
- |
400 |
|
N.A. |
| 5.3 Table-2 xix
(Phenolic compounds (as C6H5OH)) |
- |
100 |
|
N.A. |
| 5.3 Table-2 xviii
(Residual free chlorine) |
- |
100 |
|
N.A. |
| 5.3 Table-2 xvii
(Sodium (as Na)) |
- |
200 |
|
N.A. |
| 5.3 Table-2 xvi
(Magnesium (as Mg)) |
- |
250 |
|
N.A. |
| 5.3 Table-2 xv
(Calcium (as Ca),) |
- |
250 |
|
N.A. |
| 5.3 Table-2 xiv
(Alkaliniity (as HCO3)) |
- |
250 |
|
N.A. |
| 5.3 Table-2 xiii
(Sulphate (as SO4),) |
- |
250 |
|
N.A. |
| 5.3 Table-2 xii
(Selenium (as Se),) |
- |
200 |
|
N.A. |
| 5.3 Table-2 xi
(Chloride (as Cl)) |
- |
250 |
|
N.A. |
| 5.3 Table-2 x
(Aluminium (as Al)) |
- |
200 |
|
N.A. |
| 5.3 Table-2 ix
(Silver (as Ag)) |
- |
200 |
|
N.A. |
| 5.3 Table-2 viii
(Zinc (as Zn)) |
- |
200 |
|
N.A. |
| 5.3 Table-2vii
(Fluoride (as F)) |
- |
250 |
|
N.A. |
| 5.3 Table-2 vi
(Nitrite (as NO2)) |
- |
250 |
|
N.A. |
| 5.3 Table-2 v
(Nitrate (as NO3)) |
- |
250 |
|
N.A. |
| 5.3 Table-2 iv
(Manganese (as Mn)) |
- |
200 |
|
N.A. |
| 5.3 Table-2 iii
(Iron (as Fe),) |
- |
200 |
|
N.A. |
| 5.3 Table-2 ii
(Copper (as Cu)) |
- |
200 |
|
N.A. |
| 5.3 Table-2 i
(Barium (as Ba)) |
- |
200 |
|
N.A. |
| 5.3 Table-1vi
(pH) |
- |
100 |
|
N.A. |
| 5.3 Table-1 v
(Total dissolved solids) |
- |
250 |
|
N.A. |
| 5.3 Table-1 iv(Turbidity) |
- |
200 |
|
N.A. |
| 5.3 Table-1 iii
(Taste) |
- |
100 |
|
N.A. |
| 5.3 Table-1 ii
(Odour) |
- |
100 |
|
N.A. |
| 5.3 Table-1 i
(Colour) |
- |
200 |
|
N.A. |
| 5.3(Description) |
- |
100 |
|
N.A. |
| 5.2.9(Vibrio parahaemolyticus) |
- |
500 |
|
N.A. |
| 5.2.9(Vibrio cholera) |
- |
500 |
|
N.A. |
| 5.2.8(Shigella) |
- |
500 |
|
N.A. |
| 5.2.8(Salmonella) |
- |
500 |
|
N.A. |
| 5.2.7(Yeast and Mould) |
- |
500 |
|
N.A. |
| 5.2.6(Aerobic Microbial Count at 37°C) |
- |
250 |
|
N.A. |
| 5.2.6(Aerobic Microbial Count at 20-22°C) |
- |
250 |
|
N.A. |
| 5.2.5(Pseudomonas Aeruginosa) |
- |
500 |
|
N.A. |
| 5.2.4(Sulphite Reducing Anaerobes) |
- |
500 |
|
N.A. |
| 5.2.3(Staphylococcus Aureus) |
- |
500 |
|
N.A. |
| 5.2.3(Faecal Streptococci) |
- |
500 |
|
N.A. |
| 5.2.2(Coliform) |
- |
500 |
|
N.A. |
| 5.2.1(Escherichia coli (or thermotolerant bacteria)) |
- |
500 |
|
N.A. |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 29 |
IS 2347 (2017) |
Domestic pressure cooker - Specification (Sixth Revision) |
- |
-
|
14000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Capacity) |
- |
750 |
|
- |
| 5.1.1(Body, Lid, Containers and Grid) |
- |
500 |
|
- |
| 5.1.2(Body, Lid, Containers and Grid) |
- |
500 |
|
- |
| 5.1.3(Body, Lid, Containers and Grid) |
- |
500 |
|
- |
| 5.1.4(Body, Lid, Containers and Grid) |
- |
500 |
|
- |
| 5.2(Safety Relief Device) |
- |
500 |
|
- |
| 5.3(Gasket) |
- |
500 |
|
- |
| 5.4(Handles and Knobs) |
- |
500 |
|
- |
| 5.5(Pressure Regulating Device) |
- |
500 |
|
- |
| 5.6(Vent Seal Pin for Pressure Regulating Device) |
- |
500 |
|
- |
| 5.7(Vent Pipe) |
- |
500 |
|
- |
| 5.8(Vent Pipe Nut) |
- |
500 |
|
- |
| 5.9(Spring) |
- |
500 |
|
- |
| 6(CONSTRUCTION) |
- |
500 |
|
- |
| 6.1(Pressure Regulating Device) |
- |
100 |
|
- |
| 6.1.1(Pressure Regulating Device) |
- |
100 |
|
- |
| 6.1.2(Pressure Regulating Device) |
- |
100 |
|
- |
| 6.1.3(Pressure Regulating Device) |
- |
100 |
|
- |
| 6.1.4(Pressure Regulating Device) |
- |
100 |
|
- |
| 6.1.5(Pressure Regulating Device) |
- |
100 |
|
- |
| 6.2(Safety Relief Device) |
- |
100 |
|
- |
| 6.2.1(Safety Relief Device) |
- |
100 |
|
- |
| 6.2.2(Safety Relief Device) |
- |
100 |
|
- |
| 6.3.1(Temperature Responsive Pressure Relief Device) |
- |
500 |
|
- |
| 6.3.2(The cooker shall satisfy the type test prescribed in Annex D.) |
- |
500 |
|
- |
| 6.4.1(Handles and Knobs) |
- |
100 |
|
- |
| 6.4.1.1(Handles and Knobs) |
- |
2000 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
200 |
|
- |
| 7.2(WORKMANSHIP AND FINISH) |
- |
200 |
|
- |
| 7.3(WORKMANSHIP AND FINISH) |
- |
200 |
|
- |
| 7.4(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| 8.1(Air Pressure Test) |
- |
750 |
|
- |
| 8.2(Proof Pressure Test) |
- |
750 |
|
- |
| 8.3(Operating Test for Pressure Regulating Device) |
- |
750 |
|
- |
| 8.4(Test for Safety Pressure Relief Device) |
- |
1000 |
|
- |
| 8.5(Bursting Pressure Test) |
- |
1500 |
|
- |
| 8.6.1(Tests for Removal of Lid under Pressure For Outer Lid Cooker) |
- |
500 |
|
- |
| 8.6.2(Tests for Removal of Lid under Pressure For inner Lid Cooker) |
- |
500 |
|
- |
| 8.8(Test for Spring Loaded Mechanism) |
- |
3000 |
|
- |
| 8.9(Test for Spring Loaded Mechanism) |
- |
2500 |
|
- |
| 8.10 (a)(Handles of the cooker- Resistance to Burning) |
- |
500 |
|
- |
| 8.10 (b)(Handles of the cooker- Heat Resistance) |
- |
500 |
|
- |
| 8.10 (c)(Handles of the cooker- Torque Strength) |
- |
500 |
|
- |
| 8.10 (d)(Handles of the cooker- Bending Strength) |
- |
500 |
|
- |
| 8.10 (e)(Handles of the cooker- Fatigue Resistance) |
- |
500 |
|
- |
| 8.10 (f)(Handles of the cooker- Thermal Insualtion Test) |
- |
500 |
|
- |
| 8.10 NOTES (3)(Handles of the cooker - Proof Pressure) |
- |
150 |
|
- |
| 8.10 NOTES (4)(Handles of the cooker) |
- |
150 |
|
- |
| 8.10 NOTES (5)(Handles of the cooker) |
- |
150 |
|
- |
| 8.10 NOTES (6)(Handles of the cooker) |
- |
150 |
|
- |
| 8.11.1 (a)(External Coating (powder coating or ceramic coating or high temperature resistant liquid coating)) |
- |
250 |
|
- |
| 8.11.1 (b)(External Coating (powder coating or ceramic coating or high temperature resistant liquid coating)) |
- |
250 |
|
- |
| 8.11.1 (c)(External Coating (powder coating or ceramic coating or high temperature resistant liquid coating)) |
- |
250 |
|
- |
| 8.11.1.1 (Thermal shock test for externally coated cooker) |
- |
250 |
|
- |
| 8.12.1(Internal Coating) |
- |
1000 |
|
- |
| 8.14(3 Ply Construction Cooker Body) |
- |
2500 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |
| 30 |
IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
- |
-
|
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Ratings) |
- |
500 |
|
- |
| 7.1.1(Accessories Classification) |
- |
50 |
|
- |
| 7.1.2(Accessories Classification) |
- |
50 |
|
- |
| 7.1.3(Accessories Classification) |
- |
50 |
|
- |
| 7.1.4(Accessories Classification) |
- |
50 |
|
- |
| 7.1.5(Accessories Classification) |
- |
50 |
|
- |
| 7.2.1(Socket-Outlets Classification) |
- |
50 |
|
- |
| 7.2.2(Socket-Outlets Classification) |
- |
50 |
|
- |
| 7.2.3(Socket-Outlets Classification) |
- |
50 |
|
- |
| 7.2.4(Socket-Outlets Classification) |
- |
50 |
|
- |
| 7.3(Plug Classification) |
- |
100 |
|
- |
| 8.1(MARKING) |
- |
100 |
|
- |
| 8.8(MARKING) |
- |
100 |
|
- |
| 8.9(MARKING) |
- |
100 |
|
- |
| 9.1(CHECKING OF DIMENSIONS) |
- |
500 |
|
- |
| 9.2(CHECKING OF DIMENSIONS) |
- |
200 |
|
- |
| 10.1(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
100 |
|
- |
| 10.1(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
100 |
|
- |
| 10.3(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
100 |
|
- |
| 10.4(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
100 |
|
- |
| 10.5(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
100 |
|
- |
| 10.6(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
100 |
|
- |
| 10.7(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
100 |
|
- |
| 11.1(PROVISIONS FOR EARTHING) |
- |
200 |
|
- |
| 11.2(PROVISIONS FOR EARTHING) |
- |
200 |
|
- |
| 11.3(PROVISIONS FOR EARTHING) |
- |
200 |
|
- |
| 11.4(PROVISIONS FOR EARTHING) |
- |
200 |
|
- |
| 11.5(PROVISIONS FOR EARTHING) |
- |
200 |
|
- |
| 11.6(PROVISIONS FOR EARTHING) |
- |
200 |
|
- |
| 12.1.1(TERMINALS) |
- |
100 |
|
- |
| 12.1.2(TERMINALS) |
- |
100 |
|
- |
| 12.2.1(TERMINALS) |
- |
100 |
|
- |
| 12.2.2(TERMINALS) |
- |
100 |
|
- |
| 12.2.3(TERMINALS) |
- |
100 |
|
- |
| 12.2.4(TERMINALS) |
- |
100 |
|
- |
| 12.2.5(TERMINALS) |
- |
100 |
|
- |
| 12.2.6(TERMINALS) |
- |
100 |
|
- |
| 12.2.7(TERMINALS) |
- |
100 |
|
- |
| 12.2.8(TERMINALS) |
- |
100 |
|
- |
| 12.2.9(TERMINALS) |
- |
100 |
|
- |
| 12.2.10(TERMINALS) |
- |
100 |
|
- |
| 12.2.11(TERMINALS) |
- |
100 |
|
- |
| 12.3.1(TERMINALS) |
- |
100 |
|
- |
| 12.3.2(TERMINALS) |
- |
100 |
|
- |
| 12.3.3(TERMINALS) |
- |
100 |
|
- |
| 12.3.4(TERMINALS) |
- |
100 |
|
- |
| 12.3.5(TERMINALS) |
- |
100 |
|
- |
| 12.3.6(TERMINALS) |
- |
100 |
|
- |
| 12.3.7(TERMINALS) |
- |
100 |
|
- |
| 12.3.8(TERMINALS) |
- |
100 |
|
- |
| 12.3.9(TERMINALS) |
- |
100 |
|
- |
| 12.3.10(TERMINALS) |
- |
300 |
|
- |
| 12.3.11(TERMINALS) |
- |
300 |
|
- |
| 12.3.12(TERMINALS) |
- |
300 |
|
- |
| 13.1(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
| 13.2(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
- |
| 13.3(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
- |
| 13.4(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.5(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
- |
| 13.6(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
- |
| 13.7(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.8(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
- |
| 13.9(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
- |
| 13.1(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
- |
| 13.11(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
- |
| 13.12(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
- |
| 13.13(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
- |
| 13.14(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.15(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
- |
| 13.16(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.17(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.18(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
- |
| 13.19(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
- |
| 13.2(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
- |
| 13.21(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.22(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 13.23(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
100 |
|
- |
| 14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
| 14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.3(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.4(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
| 14.5(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.6(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.7(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.8(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
| 14.9(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
| 14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
| 14.11(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.12(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.13(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
| 14.14(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
| 14.15(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
| 14.16(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
| 14.17(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.18(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.19(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
| 14.21(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.22(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
| 14.23(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 14.23.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
| 14.23.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
| 14.24(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
| 14.25(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
| 14.26(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
100 |
|
- |
| 15(INTERLOCKED SOCKET-OUTLETS) |
- |
300 |
|
- |
| 16.1(RESISTANCE TO AGEING,) |
- |
500 |
|
- |
| 16.2(RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
500 |
|
- |
| 16.3(Resistance to Humidity) |
- |
500 |
|
- |
| 17.1(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
200 |
|
- |
| 17.2(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
200 |
|
- |
| 17.3(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
200 |
|
- |
| 18(OPERATION OF EARTHING CONTACTS) |
- |
500 |
|
- |
| 19(TEMPERATURE RISE) |
- |
500 |
|
- |
| 20(BREAKING CAPACITY) |
- |
500 |
|
- |
| 21(NORMAL OPERATION) |
- |
200 |
|
- |
| 21(NORMAL OPERATION) |
- |
200 |
|
- |
| 21(NORMAL OPERATION) |
- |
200 |
|
- |
| 21(NORMAL OPERATION) |
- |
200 |
|
- |
| 22.1(Verification of the Maximum Withdrawal Force) |
- |
200 |
|
- |
| 22.2(Verification of Minimum Withdrawal Force) |
- |
200 |
|
- |
| 23.1(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
100 |
|
- |
| 23.1(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
100 |
|
- |
| 23.3(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
200 |
|
- |
| 23.4(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
500 |
|
- |
| 24.1(MECHANICAL STRENGTH
For all kinds of fixed socket-outlets
) |
- |
100 |
|
- |
| 24.1(MECHANICAL STRENGTH
For portable multiple and combined socket outlets
with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
100 |
|
- |
| 24.1(MECHANICAL STRENGTH
For surface mounting boxes) |
- |
100 |
|
- |
| 24.2(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
100 |
|
- |
| 24.2(MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
100 |
|
- |
| 24.2(MECHANICAL STRENGTH
For plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
100 |
|
- |
| 24.3(MECHANICAL STRENGTH
for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
100 |
|
- |
| 24.4(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
100 |
|
- |
| 24.4(MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
100 |
|
- |
| 24.4(MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
100 |
|
- |
| 24.5(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
100 |
|
- |
| 24.5(MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
100 |
|
- |
| 24.5(MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
100 |
|
- |
| 24.6(MECHANICAL STRENGTH
For screwed glands of accessories having an IP code higher than IP20) |
- |
100 |
|
- |
| 24.7(MECHANICAL STRENGTH
For plug pins provided with insulating sleeves) |
- |
100 |
|
- |
| 24.8(MECHANICAL STRENGTH
For shuttered socket-outlets) |
- |
100 |
|
- |
| 24.9(MECHANICAL STRENGTH
For portable multiple and combined socket outlets
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
100 |
|
- |
| 24.9(MECHANICAL STRENGTH
For portable multiple and combined socket outlets
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
100 |
|
- |
| 24.1(MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
100 |
|
- |
| 24.1(MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
100 |
|
- |
| 24.11(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
100 |
|
- |
| 24.12(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
100 |
|
- |
| 24.13(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
100 |
|
- |
| 24.14.1(MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
100 |
|
- |
| 24.14.2(MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
100 |
|
- |
| 24.14.3(MECHANICAL STRENGTH
For plugs and portable socket-outlets) |
- |
100 |
|
- |
| 24.15(MECHANICAL STRENGTH
) |
- |
100 |
|
- |
| 24.16(MECHANICAL STRENGTH
) |
- |
100 |
|
- |
| 24.16(MECHANICAL STRENGTH
For shroud of portable socket-outlets) |
- |
100 |
|
- |
| 25.1(RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
250 |
|
- |
| 25.1(RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
250 |
|
- |
| 25.2(RESISTANCE TO HEAT
Parts of insulating material necessary to retain
current-carrying parts of the earthing circuit in position,
as well as parts of the front surface zone of thermoplastic material) |
- |
250 |
|
- |
| 25.3(RESISTANCE TO HEAT
Parts of insulating material not necessary to retain current-carrying parts and parts of the earthing circuit in position, even though they are in contact with them) |
- |
250 |
|
- |
| 25.4(RESISTANCE TO HEAT
) |
- |
250 |
|
- |
| 26.1(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
| 26.2(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
| 26.3(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
| 26.4(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
| 26.5(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
| 26.6(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
| 26.7(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
| 27.1(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
250 |
|
- |
| 27.2(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
250 |
|
- |
| 27.3(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
250 |
|
- |
| 28.1.1(Resistance to Abnormal Heat and to Fire
Glow-Wire Test) |
- |
400 |
|
- |
| 28.1.2(Resistance to Abnormal Heat and to Fire
for plugs with pins provided with insulating sleeves) |
- |
400 |
|
- |
| 28.2(Resistance to Tracking
For accessories other than IP code higher than IPX0 parts of insulating material retaining live parts in position) |
- |
400 |
|
- |
| 29(RESISTANCE TO RUSTING) |
- |
500 |
|
- |
| 30.1(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Pressure Test at High Temperature) |
- |
300 |
|
- |
| 30.2(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Static Damp Heat Test) |
- |
500 |
|
- |
| 30.3(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Tests at Low Temperature) |
- |
500 |
|
- |
| 30.4(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Impact Test at Low Temperature) |
- |
500 |
|
- |
| 16.2.1(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
500 |
|
- |
| 16.2.1.1(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
500 |
|
- |
| 16.2.1.2(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
500 |
|
- |
| 16.2.2(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
500 |
|
- |
|
Complete
|
|
17 Jun, 2024 |
- - |