| 721 |
IS 1580 (1991) |
Bituminous compounds for waterproofing and caulking purposes - Specification (Second Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.2.2 and 5 (water content) |
- |
|
|
|
| Clause 4.2.2 and 5 (ash content) |
- |
|
|
|
| Clause 4.2.2 and 5 (water content) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 722 |
IS 738 (1994) |
Wrought aluminium alloys, drawn tube for general engineering purposes - Specification (Third Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 8.1, Table 1 (Aluminium- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
|
|
|
| Cl. 8.1, Table 1 (Copper- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
|
|
|
| Cl. 8.1, Table 1 (Silicon- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
|
|
|
| Cl. 8.1, Table 1 (Zinc- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
|
|
|
| Cl. 8.1, Table 1 (Iron- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 723 |
IS 164 (2015) |
Ready mixed paint for road marking - Specification (Second Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.5, Table 1, S.no. x) (Flash point ) |
- |
|
|
|
| 5.1 (Composition) |
- |
|
|
|
| 5.2 (Application) |
- |
|
|
|
| Cl 5.3 (Durability) |
- |
|
|
|
| Cl. 5.4 (Lead Restriction) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. i) (Drying time, a) Surface dry) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. i) (Drying time, b) Hard dry) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. ii) (Consistency) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. iii) (Finish) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. iv) (Colour) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. v) (Wet opacity) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. vi) (Resistance to bleeding) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. vii) (Recoating property) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. viii) (Resistance to wear: a) For Grade 1) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. viii) (Resistance to wear: a) For Grade 2) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. ix) (Residue on sieve) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. xi) (xi) Mass) |
- |
|
|
|
| Cl 5.6 & Cl 5.6.2.1 (Optional Requirement for ECO-Mark, volatile organic compounds,) |
- |
|
|
|
| 5.6.2.2 ( Optional Requirement for ECO-Marktoxic metals such as cadmium, chromium (VI) and their compounds) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 724 |
IS 13334 : Part 2 (2014) |
Skimmed milk powder - Specification: Part 2 extra grade (First Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1 (ix) (Bacterial count (IS 5402)) |
- |
|
|
|
| Table 1 (x) (Coliform count (IS 5401 - Part 1)) |
- |
|
|
|
| Table 1 (xi) (Escherichia coli (IS 5887 - Part 1)) |
- |
|
|
|
| Table 1 (xii) (Coagulase positive Staphylococcus aureus (IS 5887 - Part 2)) |
- |
|
|
|
| Table 1 (xiii) (Salmonella (IS 5887 - Part 3)) |
- |
|
|
|
| Table 1 (xiv)(a) (Spore Count: a)Aerobic (Bacillus cereus) Type m (IS 5887 - Part 6)) |
- |
|
|
|
| Table 1 (xiv)(b) (Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type m (ISO 15213 : 2003)) |
- |
|
|
|
| Table 1 (xiv)(b) (Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type M (ISO 15213 : 2003)) |
- |
|
|
|
| Table 1 (xiv)(b) (Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type m (ISO 15213 : 2003)) |
- |
|
|
|
| Table 1 (xv) (Listeria monocytogenes (IS 14988 - Part 2 : 2001)) |
- |
|
|
|
| Table 1 (i) (Moisture (IS 116231or 16072)) |
- |
|
|
|
| Table 1 (ii) (Milk protein in milk solids not fat (IS 72192)) |
- |
|
|
|
| Table 1 (iii) (Milk fat (IS 117213) or Annex B) |
- |
|
|
|
| Table 1 (viii) (Scorched particles (equivalent to Disc B) (IS 13500)) |
- |
|
|
|
| Table 1 (vii) (Lactate content (IS 11202)) |
- |
|
|
|
| Table 1 (v) (Total ash (on dry basis), Annex B of IS 14433) |
- |
|
|
|
| Table 1 (iv) (Insolubility index (IS 12759)) |
- |
|
|
|
| Table 1 (vii) (Lactate content (IS 11202)) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 725 |
IS 4246 (2002) |
Domestic gas stoves for use with liquefied petroleum gases - Specification (Fifth Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 14.1(Cl 18.4 of IS 5116) (The pipe/tube used for main gas rail shall
be of mild steel. The wall thickness of main gas
rail shall be 1.6 mm + no Iimit/–0.15 mm.) |
- |
|
|
|
| Cl.24(Annexure E) (on no account the carbon monoxidel
carbon dioxide ratio of the exhaust gases of any burner.
operating at any consumption at which the burner is
stable at gas inlet pressure from 2452 kN/m2 to
3432 kN/m2 (25 gf/cm2 to 35 gf/cm2), exceed 0.02.) |
- |
|
|
|
| Cl.23 (There shall be no extinction of the flames on any
of the burners operating at maximum consumption
when the appliance is placed in a general (not
localized) current of air with a velocity of 2 m/s, as
measured with a rotating vane anemometer. The
location of the appliance relative to neighboring walls
and the direction of the draught shall be varied to
correspond to likely conditions of appliance installation.
This applies for all pressures from 2452 kN/m2 to
3432 kN/m2 (25 gf/cm2 to 35 gf/cm2).) |
- |
|
|
|
| Cl 22 (A vessel, 150 mm diameter, full of water, shall
be placed on the burner and the burner lighted at ‘ON’
position of the tap for one hour. After the test, no soot
(unburned carbon) shall be deposited on the burner
and on the bottom of the vessel. This applies for all
pressures from 2452 kN/m2 to 3432 kNlm2
(25 gf/cm2 to 35 gf/cm2)) |
- |
|
|
|
| Cl 21 (When operated at pressures 25-35 gmf/cm² there shall be no extinction of flame on any of the burner operating at the maximum of the burner when the appliance is placed in thenormal current of air with the velocity of 2 m/s as measured with a rotating vane anemometer.) |
- |
|
|
|
| Cl.20 (The ignition of the burner flames, their operation and
turning ‘OFF’ shall not give rise to undue or excessive
noise during all the operations.) |
- |
|
|
|
| Cl19.3 (The fixed minimum pilot rate shall be sufficient
to relight the main burnerat2452 kN/m2 (25 gf/cm2)
gas inlet pressure.) |
- |
|
|
|
| Cl 19.2 (Pilot flames shall be stable, without lifting
or soot deposition, at gas inlet pressure from
2 452kN/m2to3432 kN/m2 (25 gf/cm2 to 35 gf7cm2).) |
- |
|
|
|
| Cl 19.1.1 (When the gas consumption of a burner is
reduced to simmer after operating for half an hour at
full ‘ON’, the flame shall not extinguish, blow off,
strike back or form soot when tested with commercial
LPG at 2942 kN/m2 (30 gf/cm2) gas inlet pressure.) |
- |
|
|
|
| Cl 19.1 (It shall be possible to operate the appliance with
taps fully open at gas inlet pressure from 2452 kN/m2
to 3432 kN/m2 (25 gflcmz to 35 gf/cm2) without the
flame extinguishing, blowing off or striking back and
without the formation of soot) |
- |
|
|
|
| Cl18.4 (Cl14 of IS 5116) (Shall be protected against adjustment by
unauthorized persons.) |
- |
|
|
|
| Cl18.4 (Cl14 of IS 5116) (Shall be free from any weakness in design
which will give rise to failure to danger; and) |
- |
|
|
|
| Cl18.4 (Cl14 of IS 5116) (Shall open and close in times not
exceeding the following limits:Opening from cold
Closing from the
fully heated
condition
Time
Manually Non-manually
Operated, Operated,
seconds seconds
40 90
75 90) |
- |
|
|
|
| Cl18.4 (Cl14 of IS 5116) (Shall be actuated only by a pilot flame, if
provided, to ignite the main burner
without failure or delay;) |
- |
|
|
|
| Cl18.4 (Cl14 of IS 5116) (Shall prevent gas from being supplied to
the main burner until the pilot flame, if
provided, is established;) |
- |
|
|
|
| Cl18.3 (When the burner is ignited from a pilot flame
and / or by an electric/electronic method, the ignition
and flame travel shall be smooth at pressure from
2452 kN/m2 to 3432 kN/m2 (25 gf/cm2 to 35 gf/cm2)
with the burner tap turned full ‘ON’ and ignition shall
be effected without undue delay after turning on taps) |
- |
|
|
|
| cl 18.2 (If a flame is applied to any of the outer row of the
burner ports when the gas is flowing, flame travel shall
be complete. This applies for the all pressures from
2452 to 3432 kN/m2 (25 to 35 gf/cm2), taps being
fully opened and without a pan over the burner.) |
- |
|
|
|
| cl 18.1 (the burner or burners are lighted by automatic ignition
(battery of flint-operated) or by a pilot flame, it shall
not be possible for gas to be admitted to the main
burner without being smoothly ignited by the pilot
flame. Each burner should be at room temperature at
the beginning of the test and should be tested in turn) |
- |
|
|
|
| cl 18.1 (There shall be easy and safe access for lighting
and relighting each burner by a match stick and it
shall be easy to see that the burner is lighted. Where) |
- |
|
|
|
| Cl17.2.2 (When the gas consumption of a burner is
reduced to simmer as described in 17.2, the flame shall
not extinguish, blow off, strike back or form soot when
tested with commercial LPG at 2942 kN/m2
(30 gf/cm2) gas inlet pressure.) |
- |
|
|
|
| Cl17.2.1 (b) For burners above 60 I/h gas rate, 22 I/h or 26
percent of the rated capacity whichever is
higher.) |
- |
|
|
|
| Cl17.2.1 (It shall be possible to reduce the consumption
rate of the burner to the following extent by providing
a fixed simmer orifice in the gas tap:
a) For burners up to 60 I/h gas rate, 35 percent
of the rated capacity; and) |
- |
|
|
|
| Cl 17.1 (Each burner assembly under separate ‘ON/OFF’
control shall give + 8 percent of the manufacturers’
specified gas consumption in I/h or heat input in
kcaVh at 2942 kN/m2 (30 gf/cmz)) |
- |
|
|
|
| Cl.15 (When tested as specified in Annex C, the vertical
resultant deflection of the top surface measured at the
centre of length of the body, shall not exceed 2 mm
and the distance between the opposite sides
(lengthwise and widthwise) shall not change by more
than 5 mm.) |
- |
|
|
|
| Cl 14.2 (The position of the gas inlet shall allow
connection to a gas supply on either side of the
appliance. Inlet connection at the rear is also
permitted. It shall be possible to change gas inlet from
one side to other side easily by standard tools.) |
- |
|
|
|
| Cl 14.1(Cl 18.4 of IS 5116) (The
external surface of the gas rail shall be treated
to resist corrosion.) |
- |
|
|
|
| Cl 14.1(Cl 18.3 of IS 5116) (Screwed gas inlet and outlet connections
shall have threads specified in 17.3.) |
- |
|
|
|
| Cl 14.1(Cl 18.2 of IS 5116) (Where nozzles for flexible tubing are
fitted, they shall be so positioned as to facilitate
fitting of the tubing and also to prevent heating
of the tubing to more than 60°C. Shape of
nozzles is given in Fig. 7.) |
- |
|
|
|
| Cl 14.1(Cl 18 of IS 5116) (Nozzles shall be machined from free
cutting brass or mild steel.) |
- |
|
|
|
| Cl 13.1 (Cl 16 OF IS 5116) (All gas carrying parts of the appliance shall be
sound and these parts when connected, to form
a complete assembly shall also be soundagainst any gas leakage. The complete
assembly shall also be sound against any gas
leakage. The complete assembly shall be
checked at 14.71 kN/m2 (approx 150 gf/cm2).
The details of test are given in Annex J.) |
- |
|
|
|
| Cl 12.1.1 (Loose pan supports shall be so designed that
it is not possible to place them firmly in other than
proper position.) |
- |
|
|
|
| Cl 12.1 (The design of the pan supports shall be such that
it is practicable to support a pan of 100mm diameter,
over at least one top burner without the use of loose
rings, and such that 125 mm diameter vessel remains
stable over each burner. Prongs of the support shall
have suitable taper to accommodate round bottom
pans.) |
- |
|
|
|
| Cl 11 .3 (The stove comprising two or more burners shall include one burner having a rating of at least 1490 kcal/h, based on net calorific value of the gas ( when using commercial butane).) |
- |
|
|
|
| Cl 11.2 (For burners having centre flame,provision shall be made to protect the centre flame from pans resting directly on burner top and smothering the centre flame.) |
- |
|
|
|
| Cl 11 (cl 10.5 of 1S 51 I6 ) (If the burner is made and assembled in
two or more parts they shall be so designed to
provide proper self-locating arrangement so
that they are always re-assembled to its
original design preventing any maladjustment
in their assembly. This shall also be applicable
for primary air regulators.) |
- |
|
|
|
| Cl 11 (cl 10.4 of 1S 51 I6 ) (If primary air regulators are used, they
shall be so designed that they are not easily
maladjusted by the user and the construction
shall be such that primary air adjustment can
be made with the burner in place ( see Fig. 6 ).) |
- |
|
|
|
| Cl 11 (cl 10.3 of 1S 51 I6 ) (The lightness of the joints in the burner
assembly shall not depend upon adhesives or any kind ot packmg) |
- |
|
|
|
| Cl 11 (cl 10.2 of 1S 51 I6 ) (The burner supports shall be rigid and
shall be fixed in their place. Their construction
shall ensure the stability of the burners and
shall prevent their undue movement in a
horizontal plane.) |
- |
|
|
|
| Cl 11 (cl 10.1 of 1S 51 I6 ) (The construction of the burners and the
assembly shall allow their dismantling from
the supports easily with or without the use of
tools (see Fig. 5 for guidance).) |
- |
|
|
|
| Cl 10 (cl 9.2 of 1S 51 I6 ) (The size of the Jet in litres per hour of flow
of LPG at STP conditions shall be impressed
upon it.) |
- |
|
|
|
| Cl 10 (cl 9.1.1 of 1S 51 I6 ) (Injector Jet shall be made of metal, with or
without ceramic tip. The melting point of the
metal shall not be less than 650°C.) |
- |
|
|
|
| Cl 10 (cl 9.1 of 1S 51 I6 ) (Threads
6 mm, Min) |
- |
|
|
|
| Cl 10 (cl 9.1 of 1S 51 I6 ) (Projection from the face
of mounting) |
- |
|
|
|
| Cl 10 (cl 9.1 of 1S 51 I6 ) (The injector Jets shall be fixed calibrated
type and it shall not be possible to loosen them
without the use of tools. The dimensions of the
injector Jet shall conform to the following
requirements:
Across flats
6 mm. nominal
M 5 or 1BA) |
- |
|
|
|
| Cl 9 (Cl 8.11.2 of IS 5116 ) (The niting means adopted shall be
sufficiently robust to withstand normal use
without distortion or damage.) |
- |
|
|
|
| Cl 9 (Cl 8.11.1 of IS 5116 ) (Simmer flame shall be obtained by fixed
simmer orifice.) |
- |
|
|
|
| Cl 9 (Cl 8.11 of IS 5116 ) (Taps having an 'OFF' position shall have
positive stops at the 'OFF' and simmer position
except that special purpose taps (for appliance
incorporating auto or self ignition device), for
example, taps with simmering position in
between 'OFF' and 'ON' may have a movement
beyond the simmer position with a positive stop) |
- |
|
|
|
| Cl 9 (Cl 8.10 of IS 5116 ) (Screw-down valves shall be so designed
that it is impossible to withdraw completely the
valve stem in the normal operation of the tap.) |
- |
|
|
|
| Cl 9 (Cl 8.9 of IS 5116 ) (Screws, nuts, etc, which regulate the
tension of taps valve or springs, shall not loosen
in operation of the appliance. It shall not be
possible to cause a leak during normal manual
operation of tap.) |
- |
|
|
|
| Cl 9 (Cl 8.8 of IS 5116 ) (All controls or taps shall be easy to operate
at all temperatures normally attained in use.) |
- |
|
|
|
| Cl 9 (Cl 8.7 of IS 5116 ) (Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(C1 3.0 Min)) |
- |
|
|
|
| Cl 9 (Cl 8.7 of IS 5116 ) (Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(B1 0.4 Min)) |
- |
|
|
|
| Cl 9 (Cl 8.7 of IS 5116 ) (Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(A1 1.2 Min)) |
- |
|
|
|
| Cl 9 (Cl 8.7 of IS 5116 ) (Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(D 2.80 Min)) |
- |
|
|
|
| Cl 9 (Cl 8.7 of IS 5116 ) (Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(C 3.0 Min)) |
- |
|
|
|
| Cl 9 (Cl 8.7 of IS 5116 ) (Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(B 0.4 Min)) |
- |
|
|
|
| Cl 9 (Cl 8.7 of IS 5116 ) (Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(A 1.1 Min) |
- |
|
|
|
| Cl 9 (Cl 8.6 of IS 5116 ) (Each taper plug tap shall be spring-loaded
to maintain a gas-tight fit. Helical springs
fitted in taps and valves shall have flattened
ends, which shall be rounded before fitting.) |
- |
|
|
|
| Cl 9 (Cl 8.5 of IS 5116 ) (Taps shall be so made that in normal use
and with reasonable application of lubricant, the
gas passages do not become blocked (see Fig. 3).) |
- |
|
|
|
| Cl 9 (Cl 8.4 of IS 5116 ) (Preferably all taps (excluding pilot taps)
should lock in the 'OFF' position but in all cases
it shall be impossible for any handle or tap to
move accidentally, for example, by the weight
of plugs or handles or when caught by clothing.
If this requirement is satisfied by means of an
automatic locking device, the tap shall be easy
to operate with one hand.) |
- |
|
|
|
| Cl 9 (Cl 8.3 of IS 5116 ) (Where taps are fitted with adjustable stops,
there shall be means for locking the stops in
position. If screws are used for this purpose,
they shall not lead into gas passages) |
- |
|
|
|
| Cl 9 (Cl 8.2 of IS 5116 ) (The direction of rotation of a tap knob (handle) off-on-simmer shall be anticlockwise.) |
- |
|
|
|
| Cl 9 (Cl 8.2 of IS 5116 ) (Taps shall be designed so that when placed in any position on &viewed from a distance of 3 m, will definately indicate whether the valve is open or close or in intermediate position.) |
- |
|
|
|
| Cl 9 (Cl 8.2 of IS 5116 ) (All taps shall close in the same direction.) |
- |
|
|
|
| Cl 9 (Cl 8.2 of IS 5116 ) (The ON,OFF and any fixed position of tap handles shall be clearely & durably indicated or shall be obvious by design or position. Where it is not obvious which tap operates which burner , some indication shall be give) |
- |
|
|
|
| Cl 9 (Cl 8.1 of IS 5116 ) (The appliance shall have at least one tap for each burner.) |
- |
|
|
|
| Cl 8.2 of IS 4246 (The external finished surfaces shall be easily cleanable.) |
- |
|
|
|
| Cl 7 (Cl 7) |
- |
|
|
|
| Cl 6.6 (Cl 6.6) |
- |
|
|
|
| Cl 6.5 (Cl 6.5) |
- |
|
|
|
| Cl 6.4 (Cl 6.4) |
- |
|
|
|
| Cl 6.3 (Cl 6.3) |
- |
|
|
|
| Cl 6.2 (The parts of burner shall not become disconnected during operation of appliance.the centers of adjoining burner shall not be less than 180 mm.) |
- |
|
|
|
| Cl 6 , DESIGN FOR MAINTENANCE (Cl 6.1) |
- |
|
|
|
| IS 5116 . (The number of glass fragments contained in a square of side 50mm located in the area of the largest pieces shall be at least 40 numbers. (Test Method as per Cl.15.2)) |
- |
|
|
|
| IS 5116 . (Toughened glass shall fragment into small particles.) |
- |
|
|
|
| IS 5116 . (When a pan support for an uncovered burner is in contact withthe glass ceramic surface of the gas stove, the surface area ofthe pan support in contact with the glass ceramic surface shallbe at least 25 mm2.) |
- |
|
|
|
| IS 5116 . (IS 5116) |
- |
|
|
|
| Cl 5 and IS 5116 .Surface of Glass Or Glass Ceramic (IS 5116) |
- |
|
|
|
| Cl 5 and 5 of IS 5116 . (All copper and copper alloy parts shall pass mercurous nitrate test .) |
- |
|
|
|
| Cl 5 and 5 of IS 5116 . (IS 5116) |
- |
|
|
|
| Cl 8.3 (Except for burners, all other parts, namely, springs,
screws, bolts and nuts, pipes, pins, etc, which are
visible can be removed for maintenance shall be of
corrosion resistant material or treated to resist
corrosion appropriate to the conditions of use.) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 726 |
IS 733 (1983) |
Specification for wrought aluminium and aluminium alloy bars, rods and sections (For General Engineering Purposes) (Third Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 0.4, 5.1, Table 1 (Aluminium- IS 504 or by any other suitable instrumental method) |
- |
|
|
|
| Cl. 0.4, 5.1, Table 1 (Copper- IS 504 or by any other suitable instrumental method) |
- |
|
|
|
| Cl. 0.4, 5.1, Table 1 (Magnesium- IS 504 or by any other suitable instrumental method) |
- |
|
|
|
| Cl. 0.4, 5.1, Table 1 (Silicon- IS 504 or by any other suitable instrumental method) |
- |
|
|
|
| Cl. 0.4, 5.1, Table 1 (Aluminium- IS 504 or by any other suitable instrumental method) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 727 |
IS 158 (2015) |
Ready mixed paint, brushing, bituminous, black, acid, alkali and heat resisting - Specification (Fourth Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4.3, Table 1, S.no.xv) (Flash point ,) |
- |
|
|
|
| 4.1 (Composition) |
- |
|
|
|
| 4.2.1 (Lead Restriction) |
- |
|
|
|
| Cl 4.3, Table 1, S.no. i) (Drying time, Hard dry) |
- |
|
|
|
| Cl 4.3, Table 1, S.no. ii) (Consistency) |
- |
|
|
|
| Cl 4.3, Table 1, S.no. iii) (Finish) |
- |
|
|
|
| Cl 4.3, Table 1, S.no. iv) (Wet opacity) |
- |
|
|
|
| Cl 4.3, Table 1, S.no. v) (Colour) |
- |
|
|
|
| Cl 4.3, Table 1, S.no. vi) ( Mass) |
- |
|
|
|
| Cl 4.3, Table 1, S.no.xvi) (Keeping properties) |
- |
|
|
|
| Cl 4.3, Table 1, S.no.viii) (Flexibility and adhesion) |
- |
|
|
|
| Cl 4.3, Table 1, S.no. ix) (Stripping test ) |
- |
|
|
|
| Cl 4.3, Table 1, S.no. x) (Protection against corrosion under conditions of condensation) |
- |
|
|
|
| Cl 4.3, Table 1, S.no.xi) (Volatile matter, perce) |
- |
|
|
|
| Cl 4.3, Table 1, S.no.xii) (Resistance to acid) |
- |
|
|
|
| Cl 4.3, Table 1, S.no.xiii) (Resistance to alkali) |
- |
|
|
|
| Cl 4.3, Table 1, S.no.xiv) (Resistance to Heat) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 728 |
IS 14735 (1999) |
Unplasticized Polyvinyl Chloride (UPVC) Injection Moulded Fittings for Soil and Waste Discharge System for Inside and Outside Buildings Including Ventilation and Rain Water System - |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 (Colour of fittings) |
- |
|
|
|
| 7.1,Table 1 (Wall thickness) |
- |
|
|
|
| 7.2 ,Table 2&3 (Socket Dimensions) |
- |
|
|
|
| 10 (Workmanship) |
- |
|
|
|
| 11.1 (Solvent cement type or Rubber ring type) |
- |
|
|
|
| 11.2 (Socket and spigot configeration) |
- |
|
|
|
| 12.1 (Visual appearance) |
- |
|
|
|
| 12.2 (Stress relief test) |
- |
|
|
|
| 12.3 (Vicat softening tempewrature) |
- |
|
|
|
| Cl.13, IS 12235 (P-7)-2004, (Resistance to Sulphuric Acid) |
- |
|
|
|
| 16.1 (Impact test) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 729 |
IS 14151 : Part 1 (1999) |
Irrigation equipment - Sprinkler pipes - Specification: Part 1 polyethylene pipes (First Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.3 (Tensile Test) |
- |
|
|
|
| 7.2 (Reversion Test) |
- |
|
|
|
| 6.1 (VISUAL APPEARANCE) |
- |
|
|
|
| 5.1 table -1 (DIMENSIONS OF PIPES) |
- |
|
|
|
| 4.1.1 (density shall be between 940.4 kg/m’ and 958.4 kg/m3 (both inclusive) when determined at 27°C according to procedure prescribed in Annex A of IS 7328. The value of the density shall also not differ from the nominal value by more than 3 kg/m2 as per 5.2.1.1 of IS 7328.) |
- |
|
|
|
| Cl. 4.2 , IS 2530-1963, Cl. 10 (Cabon Black Content) |
- |
|
|
|
| 4.3 (Anti-oxidant) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 730 |
IS 281 (2009) |
Mild steel sliding door bolts for use with padlocks - Specification (Fourth Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 (SIZES) |
- |
|
|
|
| 6 (DIMENSIONS AND TOLERANCES-A) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-A) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-B) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-C) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-D) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-E) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-F) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-G) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-H) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-J) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-T) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-DIMENSIONS AND TOLERANCES-No. of Screw on Staple or Clip to accommodate Wood Screw N0 (IS 451)) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-No. of Rivets on bolts plates) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-No. of Rivets on Socket) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-No. of Screw holes on bolt) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-No. of Screw holes on Socket) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-No. of Screw holes on Staple) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-no. of 8m Sqire Holes for carriage bolts for plate and sockets) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-no. of 8m Sqire Holes for carriage bolts for Staple) |
- |
|
|
|
| 7.1 (MANUFACTURE-General) |
- |
|
|
|
| 7.2 (MANUFACTURE-Sliding Door Bolts, Plate Type) |
- |
|
|
|
| 7.3 (MANUFACTURE-Sliding Bolts, Clip or Bolt Type) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 731 |
IS 278 (2009) |
Galvanized steel barbed wire for fencing - Specification (Fourth Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 Table-1 (Sizes Diameter of Line wire) |
- |
|
|
|
| 5 Table-1 (Sizes Diamater of Point wire) |
- |
|
|
|
| 5 Table-1 (Sizes Mass of Completed barbed wire) |
- |
|
|
|
| 5 Table-1 (Sizes Distance between two barbs) |
- |
|
|
|
| 5 Table-1 (Sizes No. of Lays between the two consequtive barbs) |
- |
|
|
|
| 7.1 (Manufacture) |
- |
|
|
|
| 7.2 (Manufacture) |
- |
|
|
|
| 9.1 (Freedom from defects) |
- |
|
|
|
| 12.1 (Tensile Strength) |
- |
|
|
|
| 12.1 (Breaking load) |
- |
|
|
|
| 12.2.1 (Mass of zinc coating (line wire)) |
- |
|
|
|
| 12.2.2 (Mass of zinc coating (point wire)) |
- |
|
|
|
| 12.2 (Uniformity of zinc coating) |
- |
|
|
|
| 12.3 (Ductility) |
- |
|
|
|
| Cl. 6 . Table 1 of IS 7887 (Grade : 1,2,3,4,4M,6,6M,7,7M,8,8M,9,10,10M) (Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6 . Table 1 of IS 7887 (Grade : 1,2,3,4,4M,6,6M,7,7M,8,8M,9,10,10M) (Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6 . Table 1 of IS 7887 (Grade : 1,2,3,4,4M,6,6M,7,7M,8,8M,9,10,10M) (Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6 . Table 1 of IS 7887 (Grade : 1,2,3,4,4M,6,6M,7,7M,8,8M,9,10,10M) (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6 . Table 1 of IS 7887 (Grade : 1,2,3,4,4M,6,6M,7,7M,8,8M,9,10,10M) (Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 732 |
IS 10124 : Part 2 (2009) |
Fabricated pvc - U fittings for potable water supplies - Specification: Part 2 specific requirements for sockets (Second Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2.1, Table-1, Fig-1 (Minimum wall thickness for working pressure) |
- |
|
|
|
| Clause 3.2.2, and Fig. 2. (Minimum wall thickness for working pressure) |
- |
|
|
|
| 3.2.2, and Fig. 2 (Dimensions of Socket for Elastomeric Sealing Ring Joint) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 733 |
IS 10124 : Part 1 (2009) |
Fabricated PVC-U Fittings for Potable Water Supplies - Specification Part 1 General Requirements (Second Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 Table-1 Fig.1 (Dimension of Socket length) |
- |
|
|
|
| 5.2 Table-2 Fig.2 (Dimensions of socket for elastomeric sealing ring) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 734 |
IS 276 (2000) |
Austenitic - Manganese steel castings - Specification (First Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1,8.3, Table 1 (C) |
- |
|
|
|
| 8.1,8.3, Table 1 (Si) |
- |
|
|
|
| 8.1,8.3, Table 1 (Mn) |
- |
|
|
|
| 8.1,8.3, Table 1 (p) |
- |
|
|
|
| 8.1,8.3, Table 1 (S) |
- |
|
|
|
| 8.1,8.3, Table 1 (Cr) |
- |
|
|
|
| 8.1,8.3, Table 1 (Mo) |
- |
|
|
|
| 8.1,8.3, Table 1 (Ni) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 735 |
IS 1656 (2007) |
Milk - Cereal based complementary foods - Specification (Fourth Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.7.1 (Bacterial count) |
- |
|
|
|
| 5.7.2 (Coliform count) |
- |
|
|
|
| 5.7.3 (Escherichia coli) |
- |
|
|
|
| 5.7.4 (Staphylococcus aureus) |
- |
|
|
|
| 5.7.5 (Salmonella and shigella) |
- |
|
|
|
| 5.7.6 (Yeast and mould count) |
- |
|
|
|
| 4' 5.1 to 5.4 (Description) |
- |
|
|
|
| 5.8 (Moisture) |
- |
|
|
|
| 5.8 (Total protein) |
- |
|
|
|
| 5.8 (Fat) |
- |
|
|
|
| 5.8 (total Carbohydrates) |
- |
|
|
|
| 5.8 (Total Ash) |
- |
|
|
|
| 5.8 (Acid insoluble ash) |
- |
|
|
|
| 5.8 (Iron) |
- |
|
|
|
| 5.8 (Crude Fibre(on dry basis)) |
- |
|
|
|
| 5.8 (Zinc) |
- |
|
|
|
| 5.8 (Copper) |
- |
|
|
|
| 5.8 (Heavy metals, Lead) |
- |
|
|
|
| 5.8 (Arsenic) |
- |
|
|
|
| 5.8 (Tin) |
- |
|
|
|
| 5.8 (Cadmium) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 736 |
IS 210 (2009) |
Grey iron castings - Specification (First Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 (Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
|
|
|
| 7.1 (WORKMANSHIP AND FINISH) |
- |
|
|
|
| 10.1 (FREEDOM FROM DEFECTS) |
- |
|
|
|
| 10.2 (FREEDOM FROM DEFECTS) |
- |
|
|
|
| 13 (SIZE OF TEST BARS-Diameter) |
- |
|
|
|
| 13 (SIZE OF TEST BARS-Length) |
- |
|
|
|
| 15, Table 3 (TENSIL.E TEST- IS 1608 Part1 ) |
- |
|
|
|
| 16, Table 3 (Hardness Test) |
- |
|
|
|
| 17,Annex B (TRANSVERSE TEST) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 737 |
IS 208 (1996) |
Door Handles - Specification ( Sixth Revision ) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2 -Table 1- i (Ref. Cl 7.1 -Table 3 Grade 0 of IS 1079 : 2017) (Chemical composition - Carbon - IS 228) |
- |
|
|
|
| 4.2 -Table 1- iii (Ref. Cl 3.1, Table 1 Grade LCB-2 of IS 292 : 1983) (Chemical composition - Copper plus incidental nickel - IS 3685:1966) |
- |
|
|
|
| 4.2 -Table 1- iv (Ref. Cl 5.1, Table 1 Grade 5230 or 4600 of IS 617 : 1994) (Chemical composition - Copper - IS 504:1963, IS 7658:1975, IS 11035:1984) |
- |
|
|
|
| 4.2 -Table 1- v (Ref. Cl 6, Table 1 Grade 19000 of IS 737 : 2008) (Chemical composition - Aluminium - IS 504:1963) |
- |
|
|
|
| 4.2 -Table 1- vi (Ref. Cl 5.1, Table 1 Grade 63400 or 65032 of IS 733 : 1983) (Chemical composition - Aluminium - IS 504:1963) |
- |
|
|
|
| 4.2 -Table 1- vii (Ref. Cl 6.1 of IS 210 : 2009) (Chemical composition - Sulphur and/or Phosphorous) |
- |
|
|
|
| 4.2 -Table 1- viii (Ref. Cl 4.1, Table 1 of IS 742 : 1981) (Chemical composition - Aluminium- IS 2600:1964) |
- |
|
|
|
| 4.2 -Table 1- viii (Ref. Cl 4.1, Table 1 of IS 742 : 1981) (Chemical composition - Impurities-Nickel- IS 2600:1964) |
- |
|
|
|
| 3 (TYPES-Doors handle shall be of the following types according to the materials used:) |
- |
|
|
|
| 5.1 (MANUFACTURE- General) |
- |
|
|
|
| 6.1 Table2A & 2B and Fig 1,2,3,4 (DIMENSIONS - Size (A,B,C,D,E,F,G,H,I)) |
- |
|
|
|
| 6.1 Table2A & 2B and Fig 1,2,3,4 (DIMENSIONS - Size 1. No. in each Lug 2. No. in a plate when a continious plate is used 3. Size Designation of Counter-sunk Head Wood Screws
(as per IS 6760: 1972)) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 738 |
IS 1166 (1986) |
Specification for condensed milk, partly skimmed and skimmed condensed milk (Second Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.5.1.10.1 (Salmonella IS 5887 Part 3) |
- |
|
|
|
| Cl.5.1.10.1 (Shigella IS 5887 Part 7) |
- |
|
|
|
| Cl.5.1.10.2 (Coliform Count IS 5401 Part 1) |
- |
|
|
|
| Cl.5.1.10.3 (Yeast and Mould Count IS 5403) |
- |
|
|
|
| Cl.5.1.10.4 (Coagulase positive Staphylococcus aureus IS 5887 Part 2) |
- |
|
|
|
| Cl.5.1.10.5 (Escherichia coli IS 5887 Part 1) |
- |
|
|
|
| Table 1 (i) (Apendix B) (Total milk solids -Condensed Milk) |
- |
|
|
|
| Table 1 (ii) (IS : 11762-
1986) (Fat -Condensed Milk) |
- |
|
|
|
| Table 1 (iii) (Apendix C) (Sucrose -Condensed Milk) |
- |
|
|
|
| Table 1 (vi) (Apendix D) (Titratable acidity (as lactic acid) -Condensed Milk) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 739 |
IS 205 (1992) |
Non - Ferrous metal butt specification (Fourth Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1- Table 2,3,4,5 & Fig-1 & 2 (Dimensions- Type of Hinge 1.Length 2.Breadth 3.Butt Dia 4.Pin Dia 5.Thickness of Flap) |
- |
|
|
|
| 5.1- Table 2,3,4,5 & Fig-1 & 2 (Dimensions- 1. Holes for Screw Desination 2. No. of screw Holes) |
- |
|
|
|
| 6.1 (Manufacture- General) |
- |
|
|
|
| 6.2- Table 2,3,4,5 (Kunckles) |
- |
|
|
|
| 6.3 (Screw Holes) |
- |
|
|
|
| 6.3.1- Table 2,3,4,5 & Fig-1 & 2 (Screw Holes) |
- |
|
|
|
| 6.3.2- Table 2,3,4,5 (Number of Holes) |
- |
|
|
|
| 6.3.3 Fig-1 (Position of Holes) |
- |
|
|
|
| 4.1 -Table 1-Flap- i (Ref. Cl 5.1, Table 1 Designation 64430 or 65032 of IS 733 : 1983) (Chemical composition - Aluminium - IS 504) |
- |
|
|
|
| 4 -Table 1- Flap-ii (Ref. Cl 8.1, Table 1 of IS 319 : 1989) (Chemical composition - Copper - IS 3685:1966) |
- |
|
|
|
| 4 -Table 1- Flap-iii (Ref. Cl 3.1, Table 1 Grade LCB-2 of IS 292 : 1983) (Chemical composition - Copper plus incidental nickel - IS 3685:1966) |
- |
|
|
|
| 4 -Table 1- Flap-iv (Ref. Cl 6.1 , Table 1 Designation CuZn40 of IS 410 : 1977) (Chemical composition - Copper - IS 3635:1966) |
- |
|
|
|
| 4.1 -Table 1-Pin- i (Ref. Cl 5.1, Table 1 Designation 64430 of IS 733 : 1983) (Chemical composition - Aluminium - IS 504) |
- |
|
|
|
| 4.1 -Table 1-Pin- ii (Ref. Cl 6.1, Table 1 of IS 7608 : 1987) (Chemical composition - Tin - IS 4027:1967) |
- |
|
|
|
| 4.1 -Table 1-Pin- iii (Ref. Cl 6 of IS 280:1978- Cross ref. Cl. 6.1 -Table 1 of IS 7887 : 1992) (Chemical composition - Carbon - IS 228) |
- |
|
|
|
| 4.1 -Table 1-Pin- iv (Ref. Cl 4.1 -Table 1 of IS 4413 : 1981) (Chemical composition - Copper - IS 3685:1966) |
- |
|
|
|
| 4.1 -Table 1-Pin- v (Ref. Cl 7.1 -Table 1 of IS 6528 : 1995) (Chemical composition - Carbon - IS 228) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 740 |
IS 1165 (2002) |
Milk powder - Specification (First Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.5 (Bacterial count) |
- |
|
|
|
| 3.5.2 (Coliform count) |
- |
|
|
|
| 3.5.3 (Staphylococcus Aureus) |
- |
|
|
|
| 3.5.4 (Salmonella) |
- |
|
|
|
| 3.5.5 (Shigella) |
- |
|
|
|
| 3.1 (Description) |
- |
|
|
|
| 3.2 (Flavour and Taste) |
- |
|
|
|
| 3.4.5 (Moisture) |
- |
|
|
|
| 3.4.5 (Total solids) |
- |
|
|
|
| 3.4.5 (Fat) |
- |
|
|
|
| 3.4.5 (Insolubility index) |
- |
|
|
|
| 3.4.5 (Total ash) |
- |
|
|
|
| 3.4.5 (Titratable acidity (lactic acid)) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 741 |
IS 13592 (2013) |
Unplasticized Polyvinyl Chloride (PVC-U) Pipes for Soil and Waste Discharge System Inside and Outside Buiildings Including Ventilation and Rainwater System |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.5 (Surface colour of the pipes shall be dark shade of grey) |
- |
|
|
|
| Cl.7.1 (Mean outside diameter, outside diameter at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
|
|
|
| Cl.7.1 ( outside diameter at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
|
|
|
| Cl.7.1 ( wall thickness at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
|
|
|
| Cl.7.3.2 (Dimensions of sockets for solvent cementing and
grooved sockets of pipes shall be as given in Tables 3
and 4 respectively, read with Fig. 2 and 3.) |
- |
|
|
|
| Cl.8.1 (The internal and external surface of the pipes shall be
smooth and clean, and free from grooving and other
defects. The end shall be clearly cut and shall be square
with the axis of the pipe. The end may be chamfered
on the plain side.) |
- |
|
|
|
| Cl.8.2 (When tested by the method described in IS 12235
(Part 5), a length of pipe sample of 200 ± 20 mm shall
not alter in length by more than 5 percent. In the case
of socket ended pipes, this test shall be carried out on
the plain portion of pipe taken at least 100 mm away
from the root of the socket.) |
- |
|
|
|
| Cl8.3 (This test shall be carried out for socket end pipes only.
When tested by the method described in IS 12235
(Part 6), the test specimens shall not show blisters,
excessive delamination or cracking or signs of weld
line splitting.) |
- |
|
|
|
| Cl.8.4 (When determined in accordance with IS 12235 (Part 2),
the vicat softening temperature of the specimen shall
not be less than 79°C.) |
- |
|
|
|
| Cl. 9, IS 12235 Part 7 (Resistance to Sulphuric Acid) |
- |
|
|
|
| Cl.10.1 (When tested by method prescribed in IS 12235 (Part 9),the pipe shall have a true impact rate of not more than
10 percent. Mass of striker and height of fall shall be
as per Annex A.) |
- |
|
|
|
| Cl.10.2 (When determined in accordance with the method
described in IS 12235 (Part 13), the tensile strength at
break shall not be less than 45 MPa.) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 742 |
IS 8931 (1993) |
copper alloy fancy single taps, combination tap assembly and stop valves for water services |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 3 (TERMINOLOGY) |
- |
|
|
|
| Cl 4 (NOMINAL SIZES) |
- |
|
|
|
| Cl 6.6 (Screw Threads) |
- |
|
|
|
| Cl 6.7 (Waterway) |
- |
|
|
|
| Cl 6.9 (Body Seat) |
- |
|
|
|
| Cl 6.10 (Bonnet assembly) |
- |
|
|
|
| Cl 6.11 (Gland Packaging) |
- |
|
|
|
| Cl 6.12 (Flanges) |
- |
|
|
|
| Cl 6.13 (Knob) |
- |
|
|
|
| Cl 7.1 (Thickness) |
- |
|
|
|
| Cl 7.2 (Body) |
- |
|
|
|
| Cl 7.3 (Bonnet Assembly) |
- |
|
|
|
| Cl 7.3.3 (Washer Plate) |
- |
|
|
|
| Cl 9.2.1 (Water Tightness Characteristic) |
- |
|
|
|
| Cl 9.2.2 (Pressure Resistance Characteristic) |
- |
|
|
|
| Cl 9.2.3 (Hydraulic characteristic (Flow rate)) |
- |
|
|
|
| Cl 9.2.4 (Mechanical strength characteristic) |
- |
|
|
|
| Cl 7.2 (Body) |
- |
|
|
|
| Cl 7.3 (Bonnet Assembly) |
- |
|
|
|
| Cl 7.3.3 (Washer Plate) |
- |
|
|
|
| Cl 9.2.1 (Water Tightness Characteristic) |
- |
|
|
|
| Cl 9.2.2 (Pressure Resistance Characteristic) |
- |
|
|
|
| Cl 9.2.3 (Hydraulic characteristic (Flow rate)) |
- |
|
|
|
| Cl 9.2.4 (Mechanical strength characteristic) |
- |
|
|
|
| Clause 5.1, Table -1 (Cast Brass LCB-2 of IS 292 1983,Ingots, Cu + Ni) |
- |
|
|
|
| Clause 5.1, Table -1 (Cast Brass Grade DCB - 2 of IS 1264 : 1981, Die Casting, Cu) |
- |
|
|
|
| Clause 5.1, Table -1 (Leaded In Tin Bronze ,LTB-2 of IS 318, Sn) |
- |
|
|
|
| Clause 5.1, Table -1 (Brass, Tyape 1 half Hard of IS 319 : 2007, Grade -1 , Cu) |
- |
|
|
|
| Clause 5.1, Table -1 (Grade FIB of IS 6912 : 2005, Cu) |
- |
|
|
|
| Clause 5.1, Table -1 (Brass Rods Grade- CuZn 37 of IS 410 : 1977, Cu) |
- |
|
|
|
| Clause 5.1, Table -1 (Stainless Steel Grade- X04Cr17Ni12Mo2 of IS 4454(Pt-4) : 1975, C) |
- |
|
|
|
| Clause 5.1, Table -1 (Zinc base Alloys Grade- Zn Al 4 of IS 742 : 1981, Al) |
- |
|
|
|
| Clause 5.1, Table -1 (Cast Brass LCB-2 of IS 292 1983,Ingots, Cu + Ni) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 743 |
IS 13428 (2005) |
Packaged natural mineral water specification (Second Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1.1 (Escherichia coli(or thermotolerant bacteria)) |
- |
|
|
|
| 6.1.2 (Coliform , bacteria) |
- |
|
|
|
| 6.1.3 (Faecal Streptococci ) |
- |
|
|
|
| 6.1.3 (Staphylococcus Aureus) |
- |
|
|
|
| 6.1.4 (Sulphite Reducing Anaerobes ) |
- |
|
|
|
| 6.1.5 (Pseudomonas Aeruginosa ) |
- |
|
|
|
| 6.1.6 (Yeast and Mould ) |
- |
|
|
|
| 6.1.7 (Salmonella ) |
- |
|
|
|
| 6.1.7 (Shigella) |
- |
|
|
|
| 6.1.8 (Vibrio cholera ) |
- |
|
|
|
| 6.1.8 (Vibrio parahemolyticus) |
- |
|
|
|
| 6.2 Table-1 i (Colour) |
- |
|
|
|
| 6.2 Table-1 ii (Odour) |
- |
|
|
|
| 6.2 Table-1 iii (Taste) |
- |
|
|
|
| 6.2 Table-1 iv (Turbidity) |
- |
|
|
|
| 6.2 Table-1 v (Total dissolved solids) |
- |
|
|
|
| 6.2 Table-2 i (Nitrate (as NO3)) |
- |
|
|
|
| 6.2 Table-2 ii (Nitrite (as NO2)) |
- |
|
|
|
| 6.2 Table-2 iii (Sulphide (as H2S)) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 744 |
IS 204 : Part 2 (1992) |
Tower bolts - Specification: Part 2 non - Ferrous metals (Fifth Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 -Table 3- i (Ref. Cl 8, Table 1 Designation 63400 of IS 1285 : 2002) (Chemical composition - Aluminium - IS 504) |
- |
|
|
|
| 4 -Table 3- ii (Ref. Cl 5.1, Table 1 Designation 65032 of IS 733 : 1983) (Chemical composition - Aluminium - IS 504) |
- |
|
|
|
| 4 -Table 3- iii (Ref. Cl 6.1 , Table 1 Designation CuZn40 of IS 410 : 1977) (Chemical composition - Copper - IS 3635:1966) |
- |
|
|
|
| 4 -Table 3- iv (Ref. Cl 3.1, Table 1 Grade CB-2 of IS 292 : 1983) (Chemical composition - Nickel - IS 3685:1966) |
- |
|
|
|
| 4 -Table 3- v (Ref. Cl 8.1, Table 1 Grade II of IS 319 : 1974) (Chemical composition - Copper - IS 3685:1966) |
- |
|
|
|
| 4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981) (Chemical composition - Aluminium- IS 2600:1964) |
- |
|
|
|
| 4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981) (Chemical composition - Zinc- IS 2600:1964) |
- |
|
|
|
| 5.2.1 Table 1 (Particulars-Barrel Tower Bolts) |
- |
|
|
|
| 5.2.2 Table 2 (Particulars-Skeleton Tower Bolts) |
- |
|
|
|
| 6.1- Table 1 (Dimension of Barrel tower bolts-1.Size 2.Length of Bolt or Barrel-(A or B) 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Metal of Barrel (Brass or Zink Alloy/Aluminium alloy/Sheet Brass)-F 8.Dia of bore of barrel or socket- G ) |
- |
|
|
|
| 6.1- Table 1 (Dimension of barrel tower bolts-Minimum No. of equally Spaced holes in Barrel & Socket for wooden screw no 6) |
- |
|
|
|
| 6.2- Table 2 (Dimension of Skeleton Tower Bolts 1.Size 2.Length of Bolt -A 3.Length of Bolt Plate -B 4.Width of Bolt Plate or Staple-C 5.Dia of Bolt-D 6.Length of Staple-E 7.Thickness of Plate or Socket (Brass /Aluminium alloy or Zink Alloy)-F 8.Dia of bore of Plate or Staple-G 9.Dia of shank of Knob ) |
- |
|
|
|
| 6.2- Table 2 (Dimension of Skeleton Tower Bolts- Nos of Staples) |
- |
|
|
|
| 6.2- Table 2 (Dimension of Skeleton Tower Bolts-Minimum No. of Screw holes for wood screw no 4) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 745 |
IS 204 : Part 1 (1991) |
Tower bolts - Specification: Part 1 ferrous metals (Fifth Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Carbon - IS 228) |
- |
|
|
|
| 4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Manganese - IS 228) |
- |
|
|
|
| 4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Phosphorus - IS 228) |
- |
|
|
|
| 4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Sulphur - IS 228) |
- |
|
|
|
| 4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011) (Chemical composition - Carbon - IS 228) |
- |
|
|
|
| 4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011) (Chemical composition - Manganese - IS 228) |
- |
|
|
|
| 4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011) (Chemical composition - Phosphorus - IS 228) |
- |
|
|
|
| 4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011) (Chemical composition - Silicon - IS 228) |
- |
|
|
|
| 4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011) (Chemical composition - Carbon Equivalen(CE) - IS 228) |
- |
|
|
|
| 4 -Table 5- iii (Ref. Cl 6.1 of IS 210 : 2009) (Chemical composition - Sulphur and/or Phosphorous) |
- |
|
|
|
| 5.2.1 Table 1 (Particulars-Barrel Tower Bolts) |
- |
|
|
|
| 5.2.2 Table 2 (Particulars-Sami Barrel Tower Bolts) |
- |
|
|
|
| 5.2.3 Table 3 (Particulars-Riveted or Spot Welded Tower Bolts) |
- |
|
|
|
| 5.2.4 Table 4 (Particulars-Skeleton Tower Bolts) |
- |
|
|
|
| 6.1- Table 1 (Dimension of Barrel tower bolts-1.Size 2.Length of Bolt-A 3.Length of Barrel-B 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of mild steel sheet for barrel-F 8.Dia of bore of barrel or socket- G ) |
- |
|
|
|
| 6.1- Table 1 (Dimension of Barrel tower bolts-Minimum No. of equally Spaced Screw holes in Barrel and Socket for wood screw no 6) |
- |
|
|
|
| 6.2- Table 2 (Dimension of Sami Barrel Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Bolt Plate or Socket-F 8.Dia of bore of Bolt Plate or socket G ) |
- |
|
|
|
| 6.2- Table 2 (Dimension of Sami Barrel Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
|
|
|
| 6.3- Table 3 (Dimension of Riveted or Spot Welded Tower Bolts- 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7. Length of Strap-E" 8.Thickness of Back Plate -F 9.Thickness of Socket or Upper Plate and Strap- F" 10.Dia of bore of Bolt Plate or socket- G 11. Length of Alternative Socket-H ) |
- |
|
|
|
| 6.3- Table 3 (Dimension of Riveted or Spot Welded Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
|
|
|
| 6.4- Table 4 (Dimension of Skeleton Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Staple-E 7.Thickness of Plate or Staple -F 8.Dia of bore of Plate or Staple-G 9.Dia of shank of Knob-J) |
- |
|
|
|
| 6.4- Table 4 (Dimension of Skeleton Tower Bolts- Nos of Staples) |
- |
|
|
|
| 9 (PACKING) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 746 |
IS 1079 (2017) |
Hot rolled carbon steel sheet, plate and strip - Specification (Seventh Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8 (UTM) |
- |
|
|
|
| Cl 9 (Press) |
- |
|
|
|
| Cl 10 (Die Press) |
- |
|
|
|
| Cl 12 (Workmanship) |
- |
|
|
|
| Cl 13 (Length, Width & Thickness) |
- |
|
|
|
| 6.1 (Carbon %) |
- |
|
|
|
| 6.1 (Manganese %) |
- |
|
|
|
| 6.1 (Phosphorus %) |
- |
|
|
|
| 6.1 (Sulphur %) |
- |
|
|
|
| 6.1 ( Copper %) |
- |
|
|
|
| 6.1 ( Aluminium %) |
- |
|
|
|
| 6.1 ( Nitrogen%) |
- |
|
|
|
| 6.1 ( Nb) |
- |
|
|
|
| 6.1 (V) |
- |
|
|
|
| 6.1 ( Ti) |
- |
|
|
|
| 6.1 (Cr) |
- |
|
|
|
| 6.1 (Mo) |
- |
|
|
|
| 6.1 (Ni) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 747 |
IS 3854 (1997) |
Switches for domestic and similar purposes - Specification (Second Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 (Rating) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8.9 (Marking) |
- |
|
|
|
| 6 (Rating) |
- |
|
|
|
| 10 (Protection against Electric Shock) |
- |
|
|
|
| 11.1 (Provision for earthing) |
- |
|
|
|
| 12 (Terminals) |
- |
|
|
|
| 12.2.1 (Terminals) |
- |
|
|
|
| 12.2.2 (Connection of conductor) |
- |
|
|
|
| 12.2.3 (Mechanical strength of terminals) |
- |
|
|
|
| 12.2.4 (Resistance to corrosion) |
- |
|
|
|
| 12.2.5 (Undue damage to conductor) |
- |
|
|
|
| 12.2.7 (Insertion of conductor) |
- |
|
|
|
| 12.2.9 (Locking against accidental loosening) |
- |
|
|
|
| 12.2.11 (Distance between screw and conductor) |
- |
|
|
|
| 12.3.2 (Screwless terminals) |
- |
|
|
|
| 12.3.3 (Connectin of conductor) |
- |
|
|
|
| 12.3.4 (Material of terminals) |
- |
|
|
|
| 12.3.5 (Clamping) |
- |
|
|
|
| 12.3.7 (v) Interconnection of conductors [Cl. 12.3.7]) |
- |
|
|
|
| 12.3.11 (vi) Electrical & Thermal Stresses [Cl 12.3.11]) |
- |
|
|
|
| 12.3.12 (vii) Deflection Stresses [Cl. 12.3.12]) |
- |
|
|
|
| 13.1 (a) Insulating lining, barriers and the like [Cl 13.1]) |
- |
|
|
|
| 13.2 (b) Construction of switch [Cl 13.2]) |
- |
|
|
|
| 13.2 (i) Installation Test) |
- |
|
|
|
| 13.3 (c) Covers,cover plates and actuating members [Cl 13.3]) |
- |
|
|
|
| 13.4 (d) Ordinary switches [Cl 13.4]) |
- |
|
|
|
| 13.5 (e) Rotary switches [Cl 13.5]) |
- |
|
|
|
| 13.6 (f) Screws and other means [Cl 13.6]) |
- |
|
|
|
| 13.7 (g) Combination of switches or switches and socket outlets [Cl 13.7]) |
- |
|
|
|
| 13.8 (h) Assessories combined with switches [Cl. 13.8]) |
- |
|
|
|
| 13.9 (j) Switches other than ordinary switches [Cl. 13.9]) |
- |
|
|
|
| 13.1 (k) Switches to be installed in a box [Cl. 13.10]) |
- |
|
|
|
| 13.11 (l) Surface type switches other than ordinary switch [Cl. 13.11]) |
- |
|
|
|
| 13.12, 13.13, 13.14 (m) Inlet opening [Cl. 13.12.13.13 & 13.14]) |
- |
|
|
|
| 13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
| 13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
| 13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
| 13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
| 14 (Mechanism [Cl. 14]) |
- |
|
|
|
| 15.1 (Resistance to Ageing, to Harmful Ingress of water and to Humidity [Cl. 15]: Resistance to Ageing, [Cl. 15.1]) |
- |
|
|
|
| 15.2 (b)Resistance to Harmful ingress of water [Cl. 15.2]) |
- |
|
|
|
| 15.3 (c) Resistance to Humidity [Cl. 15.3]) |
- |
|
|
|
| 16.1 (Insulation resistance [Cl. 16.1]) |
- |
|
|
|
| 16.2 ( Electric Strength [Cl. 16.2]) |
- |
|
|
|
| 17 (Temperature- rise [Cl. 17]) |
- |
|
|
|
| 18 (Marking and breaking Capacity[Cl. 18]) |
- |
|
|
|
| 19 (Normal Operation [Cl. 19] a) General & Operation) |
- |
|
|
|
| 19 (b) Electric Strength) |
- |
|
|
|
| 19 (c)Temperature-rise ) |
- |
|
|
|
| 14.3 (d)Test for arcing and sparking [Cl 14.3]) |
- |
|
|
|
| 19.2 (Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
|
|
|
| 20 (Mechanical Strength Test [Cl. 20]) |
- |
|
|
|
| 21 (Resistance to Heat [Cl.21]) |
- |
|
|
|
| 22 (Screw, Current Carrying Part And Connection [Cl.22]) |
- |
|
|
|
| 22.1 (i) Screw & Nuts [Cl.22.1]) |
- |
|
|
|
| 22.4 (ii) Screw & rivets [Cl . 22.4]) |
- |
|
|
|
| 22.5 (iv) Current carrying part [Cl.22.5]) |
- |
|
|
|
| 23.2 (Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
|
|
|
| 24.1.1 (Resistance to Abnormal Heat & Fire [Cl.24.1] [Glow Wire Test] [Cl.24.1.1]) |
- |
|
|
|
| 24.2 (Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
|
|
|
| 6 (Rating) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 21 (Resistance to Heat [Cl.21]) |
- |
|
|
|
| 21 (Resistance to Heat [Cl.21]) |
- |
|
|
|
| 23.2 (Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
|
|
|
| 22.3 (iii) Electrical Connections [Cl.22.3]) |
- |
|
|
|
| 25 of IS 3854 : 1997 (Resistance to rusting) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 748 |
IS 1489 : Part 2 (2015) |
Portland - Pozzolana cement - Specification: Part 2 calcined clay based |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 -Table 2- i (Fineness 4031 Part 2) |
- |
|
|
|
| 7 -Table 2- ii- a (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
| 7 -Table 2- ii- b (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
| 7 -Table 2- iii- a (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
| 7 -Table 2-iii- b (Setting Time Final- 4031 Part 5) |
- |
|
|
|
| 7 -Table 2- iv- a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2- iv- b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2- iv- c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2- vi (Drying Shrinkage- IS 4031 Part 10) |
- |
|
|
|
| 6 - Table - 1 i (Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 ii (Magnesia - Cl 7.2 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 iii (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 iv (Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 v (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 vi ( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 749 |
IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 (Ratings) |
- |
|
|
|
| 6 (Ratings) |
- |
|
|
|
| 6 (Ratings) |
- |
|
|
|
| 7.1.1 (Accessories Classification) |
- |
|
|
|
| 7.1.2 (Accessories Classification) |
- |
|
|
|
| 7.1.3 (Accessories Classification) |
- |
|
|
|
| 7.1.4 (Accessories Classification) |
- |
|
|
|
| 7.2.1 (Socket-Outlets Classification) |
- |
|
|
|
| 7.2.2 (Socket-Outlets Classification) |
- |
|
|
|
| 7.2.3 (Socket-Outlets Classification) |
- |
|
|
|
| 7.2.4 (Socket-Outlets Classification) |
- |
|
|
|
| 7.3 (Plug Classification) |
- |
|
|
|
| 8.1 (MARKING) |
- |
|
|
|
| 8.8 (MARKING) |
- |
|
|
|
| 8.9 (MARKING) |
- |
|
|
|
| 9.1 (CHECKING OF DIMENSIONS) |
- |
|
|
|
| 9.2 (CHECKING OF DIMENSIONS) |
- |
|
|
|
| 10.1 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 10.1 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 10.4 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 10.5 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 10.6 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 10.7 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 11.1 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 11.2 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 11.3 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 11.4 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 11.5 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 11.6 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 12.1.1 (TERMINALS) |
- |
|
|
|
| 12.1.2 (TERMINALS) |
- |
|
|
|
| 12.2.1 (TERMINALS) |
- |
|
|
|
| 12.2.2 (TERMINALS) |
- |
|
|
|
| 12.2.3 (TERMINALS) |
- |
|
|
|
| 12.2.4 (TERMINALS) |
- |
|
|
|
| 12.2.5 (TERMINALS) |
- |
|
|
|
| 12.2.6 (TERMINALS) |
- |
|
|
|
| 12.2.7 (TERMINALS) |
- |
|
|
|
| 12.2.8 (TERMINALS) |
- |
|
|
|
| 12.2.9 (TERMINALS) |
- |
|
|
|
| 12.2.10 (TERMINALS) |
- |
|
|
|
| 12.2.11 (TERMINALS) |
- |
|
|
|
| 12.3.1 (TERMINALS) |
- |
|
|
|
| 12.3.2 (TERMINALS) |
- |
|
|
|
| 12.3.3 (TERMINALS) |
- |
|
|
|
| 12.3.4 (TERMINALS) |
- |
|
|
|
| 12.3.5 (TERMINALS) |
- |
|
|
|
| 12.3.6 (TERMINALS) |
- |
|
|
|
| 12.3.7 (TERMINALS) |
- |
|
|
|
| 12.3.8 (TERMINALS) |
- |
|
|
|
| 12.3.9 (TERMINALS) |
- |
|
|
|
| 12.3.10 (TERMINALS) |
- |
|
|
|
| 12.3.11 (TERMINALS) |
- |
|
|
|
| 12.3.12 (TERMINALS) |
- |
|
|
|
| 13.1 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.2 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.3 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.4 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.5 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.6 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.7 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.8 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.9 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.1 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.11 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.12 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.13 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.14 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.15 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.16 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.17 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.18 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.19 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.2 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.21 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.22 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.23 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 14.1 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.2 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.3 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.4 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.5 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.6 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.7 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.8 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.9 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.1 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.11 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.12 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.13 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.14 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.15 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.16 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.17 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.18 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.19 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.2 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.21 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.22 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.23 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.23.1 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.23.2 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.24 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.25 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.26 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 15 (INTERLOCKED SOCKET-OUTLETS) |
- |
|
|
|
| 16.1 (RESISTANCE TO AGEING,) |
- |
|
|
|
| 16.2 (RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
|
|
|
| 16.3 (Resistance to Humidity) |
- |
|
|
|
| 17.1 (INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
| 17.2 (INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
| 19 (TEMPERATURE RISE) |
- |
|
|
|
| 20 (BREAKING CAPACITY) |
- |
|
|
|
| 21 (NORMAL OPERATION) |
- |
|
|
|
| 21 (NORMAL OPERATION) |
- |
|
|
|
| 21 (NORMAL OPERATION) |
- |
|
|
|
| 22.1 (Verification of the Maximum Withdrawal Force) |
- |
|
|
|
| 22.2 (Verification of Minimum Withdrawal Force) |
- |
|
|
|
| 23.1 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
| 23.3 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
| 23.4 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
| 24.1 (MECHANICAL STRENGTH
For all kinds of fixed socket-outlets
) |
- |
|
|
|
| 24.1 (MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
| 24.1 (MECHANICAL STRENGTH
For surface mounting boxes) |
- |
|
|
|
| 24.2 (MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
| 24.2 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.2 (MECHANICAL STRENGTH
For plug
1) with enclosures, covers and bodies other than elastomeric or thermoplastic material) |
- |
|
|
|
| 24.2 (MECHANICAL STRENGTH
For plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.3 (MECHANICAL STRENGTH
for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
|
|
|
| 24.4 (MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
| 24.4 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.4 (MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.5 (MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
| 24.5 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.5 (MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.6 (MECHANICAL STRENGTH
For screwed glands of accessories having an IP code higher than IP20) |
- |
|
|
|
| 24.7 (MECHANICAL STRENGTH
For plug pins provided with insulating sleeves) |
- |
|
|
|
| 24.8 (MECHANICAL STRENGTH
For shuttered socket-outlets) |
- |
|
|
|
| 24.9 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
| 24.1 (MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
| 24.11 (MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
|
|
|
| 24.12 (MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
|
|
|
| 24.13 (MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
|
|
|
| 24.14.1 (MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
|
|
|
| 24.14.2 (MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
|
|
|
| 25.1 (RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
|
|
|
| 25.2 (RESISTANCE TO HEAT
Parts of insulating material necessary to retain
current-carrying parts of the earthing circuit in position,
as well as parts of the front surface zone of thermoplastic material) |
- |
|
|
|
| 25.3 (RESISTANCE TO HEAT
Parts of insulating material not necessary to retain current-carrying parts and parts of the earthing circuit in position, even though they are in contact with them) |
- |
|
|
|
| 25.4 (RESISTANCE TO HEAT
) |
- |
|
|
|
| 26.1 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
| 27.1 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
| 27.2 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
| 27.3 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
| 28.1.1 (Resistance to Abnormal Heat and to Fire
Glow-Wire Test) |
- |
|
|
|
| 28.1.2 (Resistance to Abnormal Heat and to Fire
for plugs with pins provided with insulating sleeves) |
- |
|
|
|
| 28.2 (Resistance to Tracking
For accessories other than IP code higher than IPX0 parts of insulating material retaining live parts in position) |
- |
|
|
|
| 29 (RESISTANCE TO RUSTING) |
- |
|
|
|
| 30.1 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Pressure Test at High Temperature) |
- |
|
|
|
| 30.2 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Static Damp Heat Test) |
- |
|
|
|
| 30.3 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Tests at Low Temperature) |
- |
|
|
|
| 30.4 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Impact Test at Low Temperature) |
- |
|
|
|
| 7.1.5 (Accessories Classification) |
- |
|
|
|
| 8.1 (MARKING) |
- |
|
|
|
| 10.1 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 23.2 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 750 |
IS 12818 (2010) |
Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.5 (Tensile Strength
IS 12235(Part 13)) |
- |
|
|
|
| 9.6 (Vicat Softening Temperature
IS 12235 (Part 2).) |
- |
|
|
|
| 9.3 (Density
IS 12235 (Part 14)) |
- |
|
|
|
| 9.1 ( Visual Appearance) |
- |
|
|
|
| 7.2 and Table 5, 6 & 7
Fig 1B (Wall thickness, Max) |
- |
|
|
|
| 7.2 and Table 5, 6 & 7
Fig 1B (Wall thickness, Min) |
- |
|
|
|
| 7.2 and Table 5, 6 & 7
Fig 1B (Mean Outer Diameter over Connection) |
- |
|
|
|
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B (Wall thickness) |
- |
|
|
|
|
Partial
|
|
- |
- - |