| 31 |
IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
- |
-
|
26813 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Marking) |
- |
520 |
|
- |
| 7.1.2 Fig.2(Minimum outside diameter of conduit) |
- |
503 |
|
Dimension and Uniformity of thickness |
| 8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
520 |
|
- |
| 9.2(Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
1790 |
|
- |
| 9.3(Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
1790 |
|
- |
| 9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
10889 |
|
- |
| 9.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
1790 |
|
- |
| 10(Resistance to Heat -Ball presure test) |
- |
4193 |
|
- |
| 11(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
1154 |
|
- |
| 12(Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
1652 |
|
- |
| 7.1.1(Maximum and minimum outside diameter of socket) |
- |
503 |
|
- |
| 7.1.1 Table-2(Length of Socket end) |
- |
503 |
|
- |
| 7.1.2(Maximum and minimum outside diameter of conduit) |
- |
503 |
|
- |
| 7.2(Minimum inside diameter of conduit) |
- |
503 |
|
- |
| 7.4(Unifomity of The wall Thickness) |
- |
503 |
|
- |
|
Complete
|
|
- |
- - |
| 32 |
IS 781 (1984) |
Specification for cast copper alloy screw down bib taps and stop valves for water services (Third Revision) |
- |
-
|
- View breakup
Rs.23000/- (10% concession for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
- |
- - |
| 33 |
IS 204 : Part 1 (1991) |
Tower bolts - Specification: Part 1 ferrous metals (Fifth Revision) |
- |
-
|
3300 View breakup
Rs.3300/- (10% concession for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(General) |
- |
300 |
|
- |
| 5.2.1 Table 1(Particulars-Barrel Tower Bolts) |
- |
500 |
|
- |
| 5.2.2 Table 2(Particulars-Sami Barrel Tower Bolts) |
- |
300 |
|
- |
| 5.2.3 Table 3(Particulars-Riveted or Spot Welded Tower Bolts) |
- |
300 |
|
- |
| 5.2.4 Table 4(Particulars-Skeleton Tower Bolts) |
- |
300 |
|
- |
| 6.1- Table 1(Dimension of Barrel tower bolts-1.Size 2.Length of Bolt-A 3.Length of Barrel-B 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of mild steel sheet for barrel-F 8.Dia of bore of barrel or socket- G ) |
- |
300 |
|
- |
| 6.2- Table 2(Dimension of Sami Barrel Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Bolt Plate or Socket-F 8.Dia of bore of Bolt Plate or socket G ) |
- |
300 |
|
- |
| 6.3- Table 3(Dimension of Riveted or Spot Welded Tower Bolts- 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7. Length of Strap-E" 8.Thickness of Back Plate -F 9.Thickness of Socket or Upper Plate and Strap- F" 10.Dia of bore of Bolt Plate or socket- G 11. Length of Alternative Socket-H ) |
- |
300 |
|
- |
| 6.4- Table 4(Dimension of Skeleton Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Staple-E 7.Thickness of Plate or Staple -F 8.Dia of bore of Plate or Staple-G 9.Dia of shank of Knob-J) |
- |
300 |
|
- |
| 6.1- Table 1(Dimension of Barrel tower bolts-Minimum No. of equally Spaced Screw holes in Barrel and Socket for wood screw no 6) |
- |
300 |
|
- |
| 6.2- Table 2(Dimension of Sami Barrel Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
300 |
|
- |
| 6.3- Table 3(Dimension of Riveted or Spot Welded Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
300 |
|
- |
| 6.4- Table 4(Dimension of Skeleton Tower Bolts-Minimum No. of Screw holes for wood screw no 6) |
- |
300 |
|
- |
|
Complete
|
|
- |
- - |
| 34 |
IS 366 (1991) |
Electric iron - Specification (Fourth Revision) |
- |
-
|
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.0(Protection against access to live parts (as per Cl. 8 of IS 302-2-3 and IS 302-1)) |
- |
2500 |
|
- |
| 9.0(Power input and current (as per Cl. 10 of IS 302-2-3 and IS 302-1)) |
- |
2500 |
|
- |
| 9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
3000 |
|
- |
| 9.0(Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
4000 |
|
- |
| 9.0(Transient Overvoltage (as per of Cl. 14 of IS 302-2-3 and Table 6 of IS 302-1)) |
- |
2000 |
|
- |
| 9.0(Moisture Resistance (as per of Cl.15 of IS 302-2-3 and IS 302-1)) |
- |
2000 |
|
- |
| 7.0(Classification (as per Cl.6 of IS 302-2-3 and Cl.6.1 of IS 302-1)) |
- |
2000 |
|
- |
| 9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
2000 |
|
- |
| 9.0(Staibilty and mechanical hazards (as per of Cl.20 of IS 302-2-3 and IS 302-1) ) |
- |
5000 |
|
- |
| 9.0(Mechanical strength (as per of Cl.21 of IS 302-2-3 and IS 302-1) ) |
- |
2000 |
|
- |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
2000 |
|
- |
| 9.0(Terminals for external conductors (as per of Cl.26 of IS 302-2-3 and IS 302-1) ) |
- |
2000 |
|
- |
| 9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
2000 |
|
- |
| 9.0(Screw and connections (as per of Cl.28 of IS 302-2-3 and IS 302-1)) |
- |
2000 |
|
- |
| 9.0(Resistance to Heat and Fire (as per of Cl.30 of IS 302-2-3 and IS 302-1)) |
- |
4000 |
|
- |
| 9.0(Resistance to Rusting (as per of Cl.31 of IS 302-2-3 and IS 302-1)) |
- |
2500 |
|
- |
| 9.0(Clearances, creepage distances and solid insulation (as per of Cl.29 of IS 302-2-3 and IS 302-1)) |
- |
2500 |
|
- |
| 10.0(Measurement of Heating up time) |
- |
5000 |
|
- |
| 11.0(Measurement of sole plate temperature) |
- |
5000 |
|
- |
| 12.0(Measurement of Tempearture Distribution) |
- |
5000 |
|
- |
| 13.0(Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
5000 |
|
- |
| 14.0(Measurement of Cyclic fluctuation of temperature of hottest point ) |
- |
5000 |
|
- |
| 16.0(Measurement of Thermostatic staibility) |
- |
5000 |
|
- |
|
Complete
|
|
- |
- - |
| 35 |
IS 204 : Part 2 (1992) |
Tower bolts - Specification: Part 2 non - Ferrous metals (Fifth Revision) |
- |
-
|
4800 View breakup
Rs.4800/- (10% concession for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1- Table 1(Dimension of Barrel tower bolts-1.Size 2.Length of Bolt or Barrel-(A or B) 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Metal of Barrel (Brass or Zink Alloy/Aluminium alloy/Sheet Brass)-F 8.Dia of bore of barrel or socket- G ) |
- |
4500 |
|
- |
| 5.1(General) |
- |
300 |
|
- |
| 5.2.1 Table 1(Particulars-Barrel Tower Bolts) |
- |
300 |
|
- |
| 5.2.2 Table 2(Particulars-Skeleton Tower Bolts) |
- |
300 |
|
- |
| 6.1- Table 1(Dimension of barrel tower bolts-Minimum No. of equally Spaced holes in Barrel & Socket for wooden screw no 6) |
- |
300 |
|
- |
| 6.2- Table 2(Dimension of Skeleton Tower Bolts 1.Size 2.Length of Bolt -A 3.Length of Bolt Plate -B 4.Width of Bolt Plate or Staple-C 5.Dia of Bolt-D 6.Length of Staple-E 7.Thickness of Plate or Socket (Brass /Aluminium alloy or Zink Alloy)-F 8.Dia of bore of Plate or Staple-G 9.Dia of shank of Knob ) |
- |
300 |
|
- |
| 6.2- Table 2(Dimension of Skeleton Tower Bolts- Nos of Staples) |
- |
300 |
|
- |
| 6.2- Table 2(Dimension of Skeleton Tower Bolts-Minimum No. of Screw holes for wood screw no 4) |
- |
300 |
|
- |
| 6.2- Table 3(PACKING) |
- |
300 |
|
- |
|
Complete
|
|
- |
- - |
| 36 |
IS 205 (1992) |
Non - Ferrous metal butt specification (Fourth Revision) |
- |
-
|
4500 View breakup
Rs.4500/- (10% concession for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1- Table 2,3,4,5 & Fig-1 & 2(Dimensions- Type of Hinge 1.Length 2.Breadth 3.Butt Dia 4.Pin Dia 5.Thickness of Flap) |
- |
2400 |
|
- |
| 5.1- Table 2,3,4,5 & Fig-1 & 2(Dimensions- 1. Holes for Screw Desination 2. No. of screw Holes) |
- |
600 |
|
- |
| 6.1(Manufacture- General) |
- |
300 |
|
- |
| 6.2- Table 2,3,4,5 (Kunckles) |
- |
300 |
|
- |
| 6.3.1- Table 2,3,4,5 & Fig-1 & 2(Screw Holes) |
- |
300 |
|
- |
| 6.3.2- Table 2,3,4,5 (Number of Holes) |
- |
300 |
|
- |
| 6.3.3 Fig-1(Position of Holes) |
- |
300 |
|
- |
| 8.1(Packing - Each hinge shall be packed in card board boxes or in any other approved packing. The number of hinges in a package shall be as under) |
- |
300 |
|
- |
|
Complete
|
|
- |
- - |
| 37 |
IS 285 (1992) |
Laundry soaps - Specification (Third Revision) |
- |
-
|
13650 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.4, Table-1 (ix) Type-2 (Built soap) Gr-2(LSD/NSD content, IS 4955) |
- |
1050 |
|
- |
| 5.4, Table-1 (viii) Type-2 (Built soap) Gr-1 & Gr-2(Chloride (as sodium chloride), IS 286) |
- |
950 |
|
- |
| 5.4, Table-1 (viii) Type-1 (Pure soap)(Chloride (as sodium chloride), IS 286) |
- |
950 |
|
- |
| 5.4, Table-1 (vii) Type-1 (Pure soap)(Glycerol, IS 286) |
- |
1050 |
|
- |
| 5.4, Table-1 (vi) Type-1 (Pure soap)(Titre of total fatty acids, IS 286) |
- |
1350 |
|
- |
| 5.4, Table-1 (v) Type-2 (Built soap) Gr-1(Matter insoluble in alcohol, IS 286) |
- |
1050 |
|
- |
| 5.4, Table-1 (iv) (Free caustic alkali, as sodium hydroxide (NaOH), IS 286) |
- |
950 |
|
- |
| 5.4, Table-1 (iii) (Unsaponified fatty matter, IS 286) |
- |
1050 |
|
- |
| 5.4, Table-1 (ii) (Rosin acids, percent by mass of total fatty matter, IS 286 ) |
- |
1050 |
|
- |
| 5.4, Table-1 (i) Type-2 (Built soap) Gr-2(Total fatty matter, IS 286) |
- |
1350 |
|
- |
| 5.3(Odour and Lathering Properties, IS 286) |
- |
500 |
|
- |
| 5.1.1(Phenolic substances, IS 286) |
- |
950 |
|
- |
|
Complete
|
|
- |
- - |
| 38 |
IS 1746 (1992) |
Shoe polish, paste - Specification (Third Revision) |
- |
-
|
13050 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1(Odour) |
- |
850 |
|
- |
| 4.1.2(Colour) |
- |
850 |
|
- |
| 4.1.3(Consistency) |
- |
850 |
|
- |
| 4.1.4(Applicability) |
- |
850 |
|
- |
| 4.1.6(colour of water extract) |
- |
850 |
|
- |
| 4.2 (table 1 S.no(i))(Softeing point of non-volatile matter) |
- |
850 |
|
- |
| 4.2 (table 1 S.no(ii))(Ash of the non-volatile matter) |
- |
850 |
|
- |
| 4.2 (table 1 S.no(iii))(pH of water extract
) |
- |
850 |
|
- |
| 4.2 (table 1 S.no(iv))(Distillation range of
volatile portion
) |
- |
850 |
|
- |
| 4.2 (table 1 S.no(v))(Flash point of volatile portion,) |
- |
850 |
|
- |
| 4.2 (table 1 S.no(vi))(Non-volatile matter
) |
- |
850 |
|
- |
|
Complete
|
|
- |
- - |
| 39 |
IS 2074 (2015) |
Ready mixed paint, air drying, red oxide - Zinc chrome, priming - Specification (Third Revision) |
- |
-
|
9500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.1 (a)(Composition, Pigment, Cl 5.1.1) |
- |
500 |
|
- |
| Cl 5.1 (b)(Composition, Driers) |
- |
500 |
|
- |
| Cl 5.1 .1 (a)(Zinc chrome, (Type 2 of
IS 51), Annex B) |
- |
500 |
|
- |
| Cl 5.1 .1 (b)(Synthetic red oxides of iron (conforming to Grade 2 or
IS 44), (conforming to Grade 3
of IS 44), 6 of IS 6947
(Part 2)) |
- |
500 |
|
- |
| Cl 5.1 .1 (c)(Suitable extenders) |
- |
500 |
|
- |
| Cl 5.1.2(Volatile vehicle) |
- |
500 |
|
- |
| Cl 5.2(Material) |
- |
500 |
|
- |
| Cl 5.3(Compatibility with Thinner, IS 1872) |
- |
500 |
|
- |
| Cl 5.4(Freedom from Objectionable Impurities) |
- |
500 |
|
- |
| Cl 5.5(Lead Restriction, IS 101(Part 8/Sec 5)) |
- |
1000 |
|
- |
| 1 (i) (a) Table 1(Consistency, Annex C) |
- |
500 |
|
- |
| 1 (i) (b) Table 1(Viscosity by ford cup No. 4, IS 101 (Part1/sec5)) |
- |
500 |
|
- |
| 1 (ii) Table 1(Mass, IS 101 (Part1/sec7)) |
- |
500 |
|
- |
| 1 (iii) (a) Table 1(Drying time, Surface Dry, IS 101 (Part3/sec1)) |
- |
500 |
|
- |
| 1 (iii) (b) Table 1(Drying time, Hard Dry, IS 101 (Part3/sec1)) |
- |
500 |
|
- |
| 1 (iv) (a) Table 1(Finish, IS 101 (Part3/sec4)) |
- |
500 |
|
- |
| 1 (iv) (b) Table 1(Gloss, IS 101 (Part4/sec4)) |
- |
500 |
|
- |
| 1 (v) Table 1(Fineness of grind, IS 101 (Part 3/Sec 5)) |
- |
500 |
|
- |
| 1 (vi) Table 1(Colour, IS 101 (Part 4/Sec 2)) |
- |
500 |
|
- |
| 1 (vii) (a) Table 1(Flexibility and adhesion: Bend test (with 6.25 mm dia mandrel and in type 1 apparatus), Clause 2 of IS 101 (Part 5/Sec 2)) |
- |
800 |
|
- |
| 1 (vii) (b) Table 1(Scratch hardness (load 1 000g), Clause 3 of IS 101 (Part 5/Sec 2)) |
- |
500 |
|
- |
| 1 (viii) Table 1(Flash point, IS 101 (Part l/Sec 6)) |
- |
500 |
|
- |
| 1 (ix) Table 1(Volume solids, IS 101 (Part 8/Sec 6)) |
- |
800 |
|
- |
| 1 (x) (a) Table 1(Resistance to humidity under condition of condensation: Resistance to humidity, Clause 2 of IS 101 (Part 6/Sec 1)) |
- |
2000 |
|
- |
| 1 (x) (b) Table 1(Resistance to humidity under condition of condensation: Resistance to sea water (applicable for marine paints only), Annex D) |
- |
2000 |
|
- |
| 1 (x) (c) Table 1(Resistance to humidity under condition of condensation: Resistance to salt spray, Annex E) |
- |
2000 |
|
- |
| 1 (xi) Table 1(Accelerated storage stability test, Annex F) |
- |
2000 |
|
- |
|
Complete
|
|
- |
- - |
| 40 |
IS 3818 (1992) |
Continuous (Piano) hinges -Specification |
- |
-
|
20300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6 (Ref. Cl.9 of IS 1868:1996)(Anodic casting thickness (Cl. 9.2 of IS 1868:1996)) |
- |
2000 |
|
- |
| 4-Fig 1(DIMENSIONS AND TOLERANCES-Nominal Size) |
- |
300 |
|
- |
| 4-Fig 1(DIMENSIONS AND TOLERANCES-B) |
- |
300 |
|
- |
| 4-Fig 1(DIMENSIONS AND TOLERANCES-C) |
- |
300 |
|
- |
| 4-Fig 1(DIMENSIONS AND TOLERANCES-D) |
- |
300 |
|
- |
| 4-Fig 1(DIMENSIONS AND TOLERANCES-T) |
- |
300 |
|
- |
| 4-Fig 1(DIMENSIONS AND TOLERANCES-CSK Screw No.) |
- |
300 |
|
- |
| 4-Fig 1(DIMENSIONS AND TOLERANCES-minimum distance of screw holes from the end of flap) |
- |
300 |
|
- |
| 4-Fig 1(DIMENSIONS AND TOLERANCES- Other Dimensions) |
- |
300 |
|
- |
| 4-Fig 2(DIMENSIONS AND TOLERANCES-CoNTINUOUS ( PIANO) HINGIS TYPB III; 50 min NOMINAL SID) |
- |
300 |
|
- |
| 4-Fig 3(DIMENSIONS AND TOLERANCES-B) |
- |
300 |
|
- |
| 4-Fig 3(DIMENSIONS AND TOLERANCES-B1) |
- |
300 |
|
- |
| 4-Fig 3(DIMENSIONS AND TOLERANCES-B2) |
- |
300 |
|
- |
| 4-Fig 3(DIMENSIONS AND TOLERANCES-C) |
- |
300 |
|
- |
| 4-Fig 3(DIMENSIONS AND TOLERANCES-D) |
- |
300 |
|
- |
| 4-Fig 3(DIMENSIONS AND TOLERANCES-T) |
- |
300 |
|
- |
| 4-Fig 3(DIMENSIONS AND TOLERANCES-CSK Screw No.) |
- |
300 |
|
- |
| 5.1(MANUFACTURE) |
- |
300 |
|
- |
| 5.2(MANUFACTURE-Knuekles) |
- |
300 |
|
- |
| 5.2(MANUFACTURE-Knuekles) |
- |
300 |
|
- |
| 5.3(MANUFACTURE-Pins) |
- |
300 |
|
- |
| 5.3(MANUFACTURE-Pins) |
- |
300 |
|
- |
| 5.4(MANUFACTURE-Screw Holes) |
- |
300 |
|
- |
| 6(Finish) |
- |
300 |
|
- |
|
Complete
|
|
- |
- - |
| 41 |
IS 5487 (1992) |
Metal polish, liquid - Specification (First Revision) |
- |
-
|
14700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.8, Table-1 (vi) (Oleic acid content, IS 5487 ) |
- |
1500 |
|
- |
| 4.8, Table-1 (v) (Flash point (Abel), IS 1448 Part-20) |
- |
1000 |
|
- |
| 4.8, Table-1 (iv) (Cyanides, IS 5487) |
- |
1000 |
|
- |
| 4.8, Table-1 (iii) (Residue on 75miron IS Sieve, IS 5487) |
- |
1000 |
|
- |
| 4.8, Table-1 (ii) (Total ammonia (as NH3), IS 5487) |
- |
1000 |
|
- |
| 4.8, Table-1 (i) (Total solids (excluding oils and fatty matter), IS 5487) |
- |
1000 |
|
- |
| 4.7(Keeping Quality, IS 5487) |
- |
7000 |
|
- |
| 4.6(Acidity of the Aqueous Extract, IS 5487) |
- |
500 |
|
- |
| 4.5(Polishing Property, IS 5487) |
- |
500 |
|
- |
| 4.4(Stability, IS 5487) |
- |
500 |
|
- |
| 4.3(Consistency, IS 5487 ) |
- |
500 |
|
- |
|
Complete
|
|
- |
- - |
| 42 |
IS 8978 (1992) |
Specification for electric instantaneous water heaters (Second Revision) |
0 |
-
|
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.8 of IS 302-2-35:2017(Protection Against Access To Live Parts) |
- |
2500 |
|
- |
| Cl.10 of IS 302-2- 35:2011(Power Input & Current ) |
- |
2500 |
|
- |
| Cl.11 of 302-2-35:2017(Heating : Temperature rise of test corner) |
- |
3000 |
|
- |
| Cl.13 of IS 302-2-35:2017(Leakage Current & Electrical Strength at Operating Temperature ) |
- |
4000 |
|
- |
| Cl.14 of IS 302-2-35:2017(Transient Over Voltages ) |
- |
2000 |
|
- |
| Cl.15 of IS 302-2-35-2011(Moisture Resistance ) |
- |
4000 |
|
- |
| Cl.16 of IS 302-2-35:2017(Leakage Current and Electric Strength (After Humidity)) |
- |
4000 |
|
- |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation) |
- |
4000 |
|
- |
| Cl 22.26 ,Cl.22.28, Cl 22.29, Cl 22.30 , Cl 22.31, Cl 22.32 of
IS 302-1:2008(Construction : Supplymentry/ double / reinforced insulation for Class II/ Class III appliance ) |
- |
2000 |
|
- |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
2000 |
|
- |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
2000 |
|
- |
| Cl.28 of IS 302-2-35:2017(Screws and Connections
) |
- |
2000 |
|
- |
| Cl.30.1 of IS 302-1:2008(Resistance to Heat and Fire) |
- |
4000 |
|
- |
| Cl.31 of IS 302-2-35: 2011(Resistance to Rusting
) |
- |
2500 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
2500 |
|
- |
| Cl.29 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation) |
- |
2500 |
|
- |
| Cl.12 of IS 8978 : 1992(Endurance) |
- |
4000 |
|
- |
|
Complete
|
|
- |
- - |
| 43 |
IS 7231 (1994) |
plastic flushing cisterns for waterclosets and urinals |
- |
-
|
10400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.1(Cistern) |
- |
600 |
|
- |
| Cl 5.2(Cover) |
- |
300 |
|
- |
| Cl 5.3(Flush pipe) |
- |
900 |
|
- |
| Cl 5.3.1(Flush pipe connection to cistern.) |
- |
900 |
|
- |
| Cl 5.4(Inlet and overflow holes) |
- |
900 |
|
- |
| Cl 5.6(Operating mechanism / lever) |
- |
300 |
|
- |
| Cl 5.7(String (Chain)) |
- |
300 |
|
- |
| Cl 5.8(Overflow pipe) |
- |
300 |
|
- |
| Cl 7.1(Flushing Arrangements) |
- |
300 |
|
- |
| Cl 7.2(Working water level) |
- |
300 |
|
- |
| Cl 7.3(Freedom from self-siphonage) |
- |
300 |
|
- |
| Cl 7.4(Reduced water level) |
- |
300 |
|
- |
| Cl 7.5(Discharge capacity) |
- |
300 |
|
- |
| Cl 7.6 & 9.2(Discharge rate ) |
- |
1000 |
|
- |
| Cl 8.1(Distortion resistance test) |
- |
500 |
|
- |
| (Cl 8.2)(Dead load test) |
- |
500 |
|
- |
| (Cl 8.3)(Front thrust test) |
- |
500 |
|
- |
| (Cl 8.4)(Impact test) |
- |
500 |
|
- |
| (Cl 9.3)(Endurance test) |
- |
1000 |
|
- |
| (Cl.6)(Finish) |
- |
300 |
|
- |
|
Complete
|
|
- |
- - |
| 44 |
IS 13983 (1994) |
Stainless Steel Sinks For Domestic Purposes |
- |
-
|
13300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9(Marking) |
- |
300 |
|
- |
| 4(Type) |
- |
300 |
|
- |
| 6(Thickness of sheet/strip) |
- |
300 |
|
- |
| 6(Depth of bowl) |
- |
300 |
|
- |
| 6(Internal dimensions of the bowl) |
- |
600 |
|
- |
| 6(Bowl locating limits) |
- |
600 |
|
- |
| 6(Co-ordinating sizes) |
- |
1800 |
|
- |
| 7.1(Consruction and workmanship) |
- |
300 |
|
- |
| 7.1.1(Consruction and workmanship) |
- |
300 |
|
- |
| 7.2(Consruction and workmanship) |
- |
300 |
|
- |
| 7.2.1(Consruction and workmanship) |
- |
300 |
|
- |
| 7.3(Drainers) |
- |
300 |
|
- |
| 7.4(Waste outlet) |
- |
300 |
|
- |
| 7.5(Tap holes) |
- |
300 |
|
- |
| 7.6(Overflows) |
- |
300 |
|
- |
| 8(Finish) |
- |
300 |
|
- |
|
Complete
|
|
- |
- - |
| 45 |
IS 208 (1996) |
Door Handles - Specification ( Sixth Revision ) |
- |
-
|
- View breakup
Rs.3000/- (10% concession for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
- |
- Included w.e.f.
18.05.2018 |
| 46 |
IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- |
-
|
8276 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
1444 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
1444 |
|
- |
| 13.5.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
1271 |
|
- |
| 13.5.1 (mech)(Wrapping Test Aluminium Wires After Stranding) |
- |
1271 |
|
- |
| 13.5.2 (mech)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
1271 |
|
- |
| 13.5.2 (mech)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
1271 |
|
- |
| 13.6 (elec)(Resistance test-Aluminium wire before Stranding) |
- |
1652 |
|
- |
| 13.6 (elec)(Resistance test-Aluminium wire after stranding) |
- |
1652 |
|
- |
| 13.7.2 (chem)(Mass of Zinc coating) |
- |
1386 |
|
- |
| 13.7.2 (chem)(Uniformity of Zinc coating) |
- |
1386 |
|
- |
| 8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires Before Stranding) |
- |
559 |
|
Nominal Size |
| 13.3 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
1444 |
|
- |
| 8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires Before Stranding) |
- |
559 |
|
Nominal Size |
| 8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires After Stranding) |
- |
559 |
|
Nominal Size |
| 8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires After Stranding) |
- |
559 |
|
Nominal Size |
| 13.3 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
1444 |
|
- |
| 13.3 Table 1 (mech)(Breaking Load of Aluminium Wires After Stranding) |
- |
1444 |
|
- |
| 13.3 Table 2 (mech)(Breaking Load of Steel Wires After Stranding) |
- |
1444 |
|
- |
|
Complete
|
|
- |
- - |
| 47 |
IS 3975 (1999) |
Low carbon galvanized steel wires, formed wires and tapes for armouring of cables - Specification (Third Revision) |
- |
-
|
- View breakup
Rs.6775/- (10% concession for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
- |
- Included w.e.f.
18.05.2018 |
| 48 |
IS 3589 (2001) |
Steel pipes for water and sewage (168.3 To 2540 Mm Outside Diameter) - Specification (Third Revision) |
Upto 457mm |
-
|
15294 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1 Table 2 Table 3(Carbon Content IS 228) |
- |
4895 |
|
- |
| 9.1(Tensile test-Strength) |
- |
1790 |
|
Tensile Strength, Yield Strength and Elongation |
| 9.2.1(Flattening test for
ERW pipes ) |
- |
1525 |
|
- |
| 9.3(Guided bend test(For SAW Pipes)) |
- |
1790 |
|
- |
| 11.1, Table 5.(Mass) |
- |
520 |
|
- |
| 12.5(Strightness) |
- |
2234 |
|
Ovality and Straighness |
| 14.1(Visual inspection, Appearance and Workmanship) |
- |
520 |
|
Workmanship |
|
Complete
|
|
- |
- - |
| 49 |
IS 4199 (2001) |
Toilet soap, liquid - Specification (Third Revision) |
- |
-
|
11100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4.7.2.2(Dermatological Safety(Requirement for ECO MARK)) |
- |
700 |
|
- |
| Cl 4.7.2.1(Phosphate (Requirement for ECO MARK)) |
- |
700 |
|
- |
| Cl.4.6, 6.3.1 - Table 1 - Sl. No.iv)(Synthetic detergent) |
- |
700 |
|
- |
| Cl.4.6, 6.3.1 - Table 1 - Sl. No.iii)(Free caustic Alkali, as K2O) |
- |
700 |
|
- |
| Cl.4.6, 6.3.1 - Table 1 - Sl. No.ii)(Matter insoluble in alcohol) |
- |
700 |
|
- |
| Cl.4.6, 6.3.1 - Table 1 - Sl. No.i)(Total fatty matter) |
- |
700 |
|
- |
| Cl.4.5.1(Phenolic substances such as cresylic acid, if added) |
- |
700 |
|
- |
| Cl.4.4(Odour) |
- |
500 |
|
- |
| Cl.4.3(Sedimentation) |
- |
800 |
|
- |
| Cl.4.2(Storage) |
- |
4100 |
|
- |
| Cl.4.1(Description) |
- |
500 |
|
- |
|
Complete
|
|
- |
- - |
| 50 |
IS 4270 (2001) |
Steel tubes used for water wells specification (Third Revision) |
- |
-
|
16093 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2(phosphorus) |
- |
3795 |
|
Chemical Composition |
| Cl 6(Tensile Test & Flattening Test) |
- |
1790 |
|
Tensile Test |
| Cl 6(Tensile Test & Flattening Test) |
- |
1525 |
|
Flattening Test |
| Cl 7(Outer Diameter, Thickness, Mass & Straightness) |
- |
3705 |
|
Dimension Test |
| Cl 7(Outer Diameter, Thickness, Mass & Straightness) |
- |
1352 |
|
Straightness |
| Cl 12(Bituminous Coating & Galvanizing ) |
- |
1386 |
|
Coating Test |
| Cl 14(Workmanship) |
- |
520 |
|
- |
|
Complete
|
|
- |
- - |
| 51 |
IS 4454 : Part 4 (2001) |
Steel wires for mechanical springs: Part 4 stainless steel wire (Second Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
- |
- - |
| 52 |
IS 4159 (2002) |
Mineral filled sheathed heating elements - Specification (Third Revision) |
- |
-
|
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.8 of IS 4159:2002 & IS 302‐1:2008(Protection Against Electric Shock) |
- |
2000 |
|
- |
| Cl.10 of IS 4159:2002 &
IS 302-1:2008(Input & Current) |
- |
2500 |
|
- |
| Cl.13 of IS 4159:2002 & IS 302-1: 2008(Electrical Insulation and Leakage Current at Operating Temperature) |
- |
4000 |
|
- |
| Cl.15 of IS 4159:2002 & IS 302-1: 2008(Moisture Resistance) |
- |
4000 |
|
- |
| Cl.18 of IS 4159:2002(Endurance Test
) |
- |
4000 |
|
- |
| Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
2000 |
|
- |
| Cl.21 of IS 4159:2002 & IS 302-1: 2008(Mechanical Strength) |
- |
2000 |
|
- |
| Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
2000 |
|
- |
| Cl.27 of IS 4159:2002 & IS 302-1: 2008(Provision for Earthing) |
- |
2000 |
|
- |
| Cl.28 of IS 4159:2002 & IS 302-1: 2008(Screws & Connection ) |
- |
2000 |
|
- |
| Cl. 30 of IS 4159:2002 &
IS 302-1: 2008(Resistance to Heat, Fire and Tracking) |
- |
4000 |
|
- |
| Cl.20 of IS 4159:2002 & IS 302-1: 2008(Stability & Mechanical Hazards
) |
- |
5000 |
|
- |
| Cl. 29 of IS 4159:2002 &
IS 302-1: 2008(Creepage Distances & Clearances) |
- |
2500 |
|
- |
|
Complete
|
|
- |
- - |
| 53 |
IS 4246 (2002) |
Domestic gas stoves for use with liquefied petroleum gases - Specification (Fifth Revision) |
- |
-
|
14100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.24(Annexure E)(on no account the carbon monoxidel
carbon dioxide ratio of the exhaust gases of any burner.
operating at any consumption at which the burner is
stable at gas inlet pressure from 2452 kN/m2 to
3432 kN/m2 (25 gf/cm2 to 35 gf/cm2), exceed 0.02.) |
- |
300 |
|
- |
| Cl.23(There shall be no extinction of the flames on any
of the burners operating at maximum consumption
when the appliance is placed in a general (not
localized) current of air with a velocity of 2 m/s, as
measured with a rotating vane anemometer. The
location of the appliance relative to neighboring walls
and the direction of the draught shall be varied to
correspond to likely conditions of appliance installation.
This applies for all pressures from 2452 kN/m2 to
3432 kN/m2 (25 gf/cm2 to 35 gf/cm2).) |
- |
300 |
|
- |
| Cl 22(A vessel, 150 mm diameter, full of water, shall
be placed on the burner and the burner lighted at ‘ON’
position of the tap for one hour. After the test, no soot
(unburned carbon) shall be deposited on the burner
and on the bottom of the vessel. This applies for all
pressures from 2452 kN/m2 to 3432 kNlm2
(25 gf/cm2 to 35 gf/cm2)) |
- |
300 |
|
- |
| Cl 21(When operated at pressures 25-35 gmf/cm² there shall be no extinction of flame on any of the burner operating at the maximum of the burner when the appliance is placed in thenormal current of air with the velocity of 2 m/s as measured with a rotating vane anemometer.) |
- |
300 |
|
- |
| Cl.20(The ignition of the burner flames, their operation and
turning ‘OFF’ shall not give rise to undue or excessive
noise during all the operations.) |
- |
300 |
|
- |
| Cl19.3(The fixed minimum pilot rate shall be sufficient
to relight the main burnerat2452 kN/m2 (25 gf/cm2)
gas inlet pressure.) |
- |
300 |
|
- |
| Cl 19.2(Pilot flames shall be stable, without lifting
or soot deposition, at gas inlet pressure from
2 452kN/m2to3432 kN/m2 (25 gf/cm2 to 35 gf7cm2).) |
- |
300 |
|
- |
| Cl 19.1.1(When the gas consumption of a burner is
reduced to simmer after operating for half an hour at
full ‘ON’, the flame shall not extinguish, blow off,
strike back or form soot when tested with commercial
LPG at 2942 kN/m2 (30 gf/cm2) gas inlet pressure.) |
- |
300 |
|
- |
| Cl 19.1(It shall be possible to operate the appliance with
taps fully open at gas inlet pressure from 2452 kN/m2
to 3432 kN/m2 (25 gflcmz to 35 gf/cm2) without the
flame extinguishing, blowing off or striking back and
without the formation of soot) |
- |
300 |
|
- |
| Cl18.4 (Cl14 of IS 5116)(Shall be protected against adjustment by
unauthorized persons.) |
- |
300 |
|
- |
| Cl18.4 (Cl14 of IS 5116)(Shall be free from any weakness in design
which will give rise to failure to danger; and) |
- |
300 |
|
- |
| Cl18.4 (Cl14 of IS 5116)(Shall open and close in times not
exceeding the following limits:Opening from cold
Closing from the
fully heated
condition
Time
Manually Non-manually
Operated, Operated,
seconds seconds
40 90
75 90) |
- |
300 |
|
- |
| Cl18.4 (Cl14 of IS 5116)(Shall be actuated only by a pilot flame, if
provided, to ignite the main burner
without failure or delay;) |
- |
300 |
|
- |
| Cl18.4 (Cl14 of IS 5116)(Shall, after flame failure, stop all gas flow
to the main burner;) |
- |
300 |
|
- |
| Cl18.4 (Cl14 of IS 5116)(Shall prevent gas from being supplied to
the main burner until the pilot flame, if
provided, is established;) |
- |
300 |
|
- |
| Cl18.3(When the burner is ignited from a pilot flame
and / or by an electric/electronic method, the ignition
and flame travel shall be smooth at pressure from
2452 kN/m2 to 3432 kN/m2 (25 gf/cm2 to 35 gf/cm2)
with the burner tap turned full ‘ON’ and ignition shall
be effected without undue delay after turning on taps) |
- |
300 |
|
- |
| cl 18.2(If a flame is applied to any of the outer row of the
burner ports when the gas is flowing, flame travel shall
be complete. This applies for the all pressures from
2452 to 3432 kN/m2 (25 to 35 gf/cm2), taps being
fully opened and without a pan over the burner.) |
- |
300 |
|
- |
| cl 18.1(the burner or burners are lighted by automatic ignition
(battery of flint-operated) or by a pilot flame, it shall
not be possible for gas to be admitted to the main
burner without being smoothly ignited by the pilot
flame. Each burner should be at room temperature at
the beginning of the test and should be tested in turn) |
- |
300 |
|
- |
| cl 18.1(There shall be easy and safe access for lighting
and relighting each burner by a match stick and it
shall be easy to see that the burner is lighted. Where) |
- |
300 |
|
- |
| Cl17.2.2(When the gas consumption of a burner is
reduced to simmer as described in 17.2, the flame shall
not extinguish, blow off, strike back or form soot when
tested with commercial LPG at 2942 kN/m2
(30 gf/cm2) gas inlet pressure.) |
- |
300 |
|
- |
| Cl17.2.1(b) For burners above 60 I/h gas rate, 22 I/h or 26
percent of the rated capacity whichever is
higher.) |
- |
300 |
|
- |
| Cl17.2.1(It shall be possible to reduce the consumption
rate of the burner to the following extent by providing
a fixed simmer orifice in the gas tap:
a) For burners up to 60 I/h gas rate, 35 percent
of the rated capacity; and) |
- |
300 |
|
- |
| Cl 17.1(Each burner assembly under separate ‘ON/OFF’
control shall give + 8 percent of the manufacturers’
specified gas consumption in I/h or heat input in
kcaVh at 2942 kN/m2 (30 gf/cmz)) |
- |
300 |
|
- |
| Cl.15(When tested as specified in Annex C, the vertical
resultant deflection of the top surface measured at the
centre of length of the body, shall not exceed 2 mm
and the distance between the opposite sides
(lengthwise and widthwise) shall not change by more
than 5 mm.) |
- |
300 |
|
- |
| Cl 14.2(The position of the gas inlet shall allow
connection to a gas supply on either side of the
appliance. Inlet connection at the rear is also
permitted. It shall be possible to change gas inlet from
one side to other side easily by standard tools.) |
- |
300 |
|
- |
| Cl 14.1(Cl 18.4 of IS 5116)(The
external surface of the gas rail shall be treated
to resist corrosion.) |
- |
300 |
|
- |
| Cl 14.1(Cl 18.4 of IS 5116)(The pipe/tube used for main gas rail shall
be of mild steel. The wall thickness of main gas
rail shall be 1.6 mm + no Iimit/–0.15 mm.) |
- |
300 |
|
- |
| Cl 14.1(Cl 18.3 of IS 5116)(Screwed gas inlet and outlet connections
shall have threads specified in 17.3.) |
- |
300 |
|
- |
| Cl 14.1(Cl 18.2 of IS 5116)(Where nozzles for flexible tubing are
fitted, they shall be so positioned as to facilitate
fitting of the tubing and also to prevent heating
of the tubing to more than 60°C. Shape of
nozzles is given in Fig. 7.) |
- |
1500 |
|
- |
| Cl 14.1(Cl 18 of IS 5116)(Nozzles shall be machined from free
cutting brass or mild steel.) |
- |
300 |
|
- |
| Cl 13.2 .1(The stove may be provided with a gas leak
indicator. If gas leak indicator is provided, it shall
conform to the requirements of IS 13432 (Part 1) or
IS 13432 (Part 2).) |
- |
300 |
|
- |
| Cl 13.1 (Cl 16 OF IS 5116)(All gas carrying parts of the appliance shall be
sound and these parts when connected, to form
a complete assembly shall also be soundagainst any gas leakage. The complete
assembly shall also be sound against any gas
leakage. The complete assembly shall be
checked at 14.71 kN/m2 (approx 150 gf/cm2).
The details of test are given in Annex J.) |
- |
300 |
|
- |
| Cl 12.1.1(Loose pan supports shall be so designed that
it is not possible to place them firmly in other than
proper position.) |
- |
300 |
|
- |
| Cl 12.1(The design of the pan supports shall be such that
it is practicable to support a pan of 100mm diameter,
over at least one top burner without the use of loose
rings, and such that 125 mm diameter vessel remains
stable over each burner. Prongs of the support shall
have suitable taper to accommodate round bottom
pans.) |
- |
300 |
|
- |
| Cl 11 .3(The stove comprising two or more burners shall include one burner having a rating of at least 1490 kcal/h, based on net calorific value of the gas ( when using commercial butane).) |
- |
300 |
|
- |
| Cl 11.2(For burners having centre flame,provision shall be made to protect the centre flame from pans resting directly on burner top and smothering the centre flame.) |
- |
300 |
|
- |
| Cl 11 (cl 10.5 of 1S 51 I6 )(If the burner is made and assembled in
two or more parts they shall be so designed to
provide proper self-locating arrangement so
that they are always re-assembled to its
original design preventing any maladjustment
in their assembly. This shall also be applicable
for primary air regulators.) |
- |
300 |
|
- |
| Cl 11 (cl 10.4 of 1S 51 I6 )(If primary air regulators are used, they
shall be so designed that they are not easily
maladjusted by the user and the construction
shall be such that primary air adjustment can
be made with the burner in place ( see Fig. 6 ).) |
- |
300 |
|
- |
| Cl 11 (cl 10.3 of 1S 51 I6 )(The lightness of the joints in the burner
assembly shall not depend upon adhesives or any kind ot packmg) |
- |
300 |
|
- |
| Cl 11 (cl 10.2 of 1S 51 I6 )(The burner supports shall be rigid and
shall be fixed in their place. Their construction
shall ensure the stability of the burners and
shall prevent their undue movement in a
horizontal plane.) |
- |
300 |
|
- |
| Cl 11 (cl 10.1 of 1S 51 I6 )(The construction of the burners and the
assembly shall allow their dismantling from
the supports easily with or without the use of
tools (see Fig. 5 for guidance).) |
- |
300 |
|
- |
| Cl 10 (cl 9.2 of 1S 51 I6 )(The size of the Jet in litres per hour of flow
of LPG at STP conditions shall be impressed
upon it.) |
- |
300 |
|
- |
| Cl 10 (cl 9.1.1 of 1S 51 I6 )(Injector Jet shall be made of metal, with or
without ceramic tip. The melting point of the
metal shall not be less than 650°C.) |
- |
300 |
|
- |
| Cl 10 (cl 9.1 of 1S 51 I6 )(Threads
6 mm, Min) |
- |
300 |
|
- |
| Cl 10 (cl 9.1 of 1S 51 I6 )(Projection from the face
of mounting) |
- |
300 |
|
- |
| Cl 10 (cl 9.1 of 1S 51 I6 )(The injector Jets shall be fixed calibrated
type and it shall not be possible to loosen them
without the use of tools. The dimensions of the
injector Jet shall conform to the following
requirements:
Across flats
6 mm. nominal
M 5 or 1BA) |
- |
300 |
|
- |
| Cl 9 (Cl 8.11.2 of IS 5116 )(The niting means adopted shall be
sufficiently robust to withstand normal use
without distortion or damage.) |
- |
300 |
|
- |
| Cl 9 (Cl 8.11.1 of IS 5116 )(Simmer flame shall be obtained by fixed
simmer orifice.) |
- |
300 |
|
- |
| Cl 9 (Cl 8.11 of IS 5116 )(Taps having an 'OFF' position shall have
positive stops at the 'OFF' and simmer position
except that special purpose taps (for appliance
incorporating auto or self ignition device), for
example, taps with simmering position in
between 'OFF' and 'ON' may have a movement
beyond the simmer position with a positive stop) |
- |
300 |
|
- |
| Cl 9 (Cl 8.10 of IS 5116 )(Screw-down valves shall be so designed
that it is impossible to withdraw completely the
valve stem in the normal operation of the tap.) |
- |
300 |
|
- |
| Cl 9 (Cl 8.9 of IS 5116 )(Screws, nuts, etc, which regulate the
tension of taps valve or springs, shall not loosen
in operation of the appliance. It shall not be
possible to cause a leak during normal manual
operation of tap.) |
- |
300 |
|
- |
| Cl 9 (Cl 8.8 of IS 5116 )(All controls or taps shall be easy to operate
at all temperatures normally attained in use.) |
- |
300 |
|
- |
| Cl 9 (Cl 8.7 of IS 5116 )(Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(C1 3.0 Min)) |
- |
300 |
|
- |
| Cl 9 (Cl 8.7 of IS 5116 )(Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(B1 0.4 Min)) |
- |
300 |
|
- |
| Cl 9 (Cl 8.7 of IS 5116 )(Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(A1 1.2 Min)) |
- |
300 |
|
- |
| Cl 9 (Cl 8.7 of IS 5116 )(Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(D 2.80 Min)) |
- |
300 |
|
- |
| Cl 9 (Cl 8.7 of IS 5116 )(Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(C 3.0 Min)) |
- |
300 |
|
- |
| Cl 9 (Cl 8.7 of IS 5116 )(Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(B 0.4 Min)) |
- |
300 |
|
- |
| Cl 9 (Cl 8.7 of IS 5116 )(Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(A 1.1 Min) |
- |
300 |
|
- |
| Cl 9 (Cl 8.6 of IS 5116 )(Each taper plug tap shall be spring-loaded
to maintain a gas-tight fit. Helical springs
fitted in taps and valves shall have flattened
ends, which shall be rounded before fitting.) |
- |
300 |
|
- |
| Cl 9 (Cl 8.5 of IS 5116 )(Taps shall be so made that in normal use
and with reasonable application of lubricant, the
gas passages do not become blocked (see Fig. 3).) |
- |
300 |
|
- |
| Cl 9 (Cl 8.4 of IS 5116 )(Preferably all taps (excluding pilot taps)
should lock in the 'OFF' position but in all cases
it shall be impossible for any handle or tap to
move accidentally, for example, by the weight
of plugs or handles or when caught by clothing.
If this requirement is satisfied by means of an
automatic locking device, the tap shall be easy
to operate with one hand.) |
- |
300 |
|
- |
| Cl 9 (Cl 8.3 of IS 5116 )(Where taps are fitted with adjustable stops,
there shall be means for locking the stops in
position. If screws are used for this purpose,
they shall not lead into gas passages) |
- |
300 |
|
- |
| Cl 9 (Cl 8.2 of IS 5116 )(The direction of rotation of a tap knob (handle) off-on-simmer shall be anticlockwise.) |
- |
300 |
|
- |
| Cl 9 (Cl 8.2 of IS 5116 )(Taps shall be designed so that when placed in any position on &viewed from a distance of 3 m, will definately indicate whether the valve is open or close or in intermediate position.) |
- |
300 |
|
- |
| Cl 9 (Cl 8.2 of IS 5116 )(All taps shall close in the same direction.) |
- |
300 |
|
- |
| Cl 9 (Cl 8.2 of IS 5116 )(The ON,OFF and any fixed position of tap handles shall be clearely & durably indicated or shall be obvious by design or position. Where it is not obvious which tap operates which burner , some indication shall be give) |
- |
300 |
|
- |
| Cl 9 (Cl 8.1 of IS 5116 )(The appliance shall have at least one tap for each burner.) |
- |
300 |
|
- |
| Cl 8.3(Except for burners, all other parts, namely, springs,
screws, bolts and nuts, pipes, pins, etc, which are
visible can be removed for maintenance shall be of
corrosion resistant material or treated to resist
corrosion appropriate to the conditions of use.) |
- |
300 |
|
- |
| Cl 8.2 of IS 4246(The external finished surfaces shall be easily cleanable.) |
- |
300 |
|
- |
| Cl 8.1 ,(Cl 7.5 of IS 5116)(Concealed tubular fittings liable to corrode shall be protected by bituminous paint or other equally protective materia) |
- |
300 |
|
- |
| Cl 8.1 ,(Cl 7.4.2 of IS 5116)(Resistance to Heating) |
- |
300 |
|
- |
| Cl 8.1 ,(Cl 7.4.1 of IS 5116)(Resistance to Abrasion) |
- |
300 |
|
- |
| Cl 8.1 ,(Cl 7.3.3 of IS 5116)(,Corrosion Resistance The plated article shall be subjected to the test
for 12 h as covered in IS 6910 : 1985. The rating
shall be assigned using the methods described
in IS 6009 : 1970.) |
- |
300 |
|
- |
| Cl 8.1 (Cl 7.3.2 of IS 5116)(Adhesion Test) |
- |
300 |
|
- |
| Cl 8.1(The top flat surface of the body of the appliance, if plated, shallhave a coating of minimum of 10 microns of nickel followed by0.2 microns minimum of chromium.) |
- |
300 |
|
- |
| Cl 8.1(In addition to the relevant requirements given
in 7 of IS 5116, the requirements given in 8.2 and 8.3
shall apply. given in Annex E.) |
- |
300 |
|
- |
| Cl 8.1(In addition to the relevant requirements given
in 7 of IS 5116, the requirements given in 8.2 and 8.3
shall apply.) |
- |
300 |
|
- |
| Cl 8.1(In addition to the relevant requirements given
in 7 of IS 5116, the requirements given in 8.2 and 8.3
shall apply.) |
- |
300 |
|
- |
| Cl 8.1(In addition to the relevant requirements given
in 7 of IS 5116, the requirements given in 8.2 and 8.3
shall apply.) |
- |
300 |
|
- |
| Cl 7(Cl 7) |
- |
300 |
|
- |
| Cl 6.6(Cl 6.6) |
- |
300 |
|
- |
| Cl 6.5(Cl 6.5) |
- |
300 |
|
- |
| Cl 6.4(Cl 6.4) |
- |
300 |
|
- |
| Cl 6.3(Cl 6.3) |
- |
300 |
|
- |
| Cl 6.2(The parts of burner shall not become disconnected during operation of appliance.the centers of adjoining burner shall not be less than 180 mm.) |
- |
300 |
|
- |
| Cl 6 , DESIGN FOR MAINTENANCE(Cl 6.1) |
- |
300 |
|
- |
| IS 5116 .(The number of glass fragments contained in a square of side 50mm located in the area of the largest pieces shall be at least 40 numbers. (Test Method as per Cl.15.2)) |
- |
300 |
|
- |
| IS 5116 .(Toughened glass shall fragment into small particles.) |
- |
300 |
|
- |
| IS 5116 .(When a pan support for an uncovered burner is in contact withthe glass ceramic surface of the gas stove, the surface area ofthe pan support in contact with the glass ceramic surface shallbe at least 25 mm2.) |
- |
300 |
|
- |
| Cl 5 and IS 5116 .Surface of Glass Or Glass Ceramic(IS 5116) |
- |
300 |
|
- |
| Cl 5 and 5 of IS 5116 .(All copper and copper alloy parts shall pass mercurous nitrate test .) |
- |
2500 |
|
- |
| 4.1 of IS 5116(General) |
- |
300 |
|
- |
| 4.2 of IS 5116(General) |
- |
300 |
|
- |
| 4.1.1(General) |
- |
300 |
|
- |
| 25.1 ( 23.1 of IS 5116 )(Fire Hazard and Limiting Temperatures) |
- |
1000 |
|
- |
| 25.1 ( 23.2 of IS 5116 )(Fire Hazard and Limiting Temperatures) |
- |
1000 |
|
- |
| 25.1 ( 23.2.1 of IS 5116 )(Fire Hazard and Limiting Temperatures) |
- |
1000 |
|
- |
| 25.1 ( 23.2.2 of IS 5116 )(Fire Hazard and Limiting Temperatures) |
- |
1000 |
|
- |
| 25.2(Fire Hazard and Limiting Temperatures) |
- |
1000 |
|
- |
| 26 (for burner 1)(Thermal Efficiency) |
- |
1000 |
|
- |
| 26 (for burner 2)(Thermal Efficiency) |
- |
2000 |
|
- |
| 26 (for burner 3)(Thermal Efficiency) |
- |
3000 |
|
- |
| 26 (for burner 4)(Thermal Efficiency) |
- |
4000 |
|
- |
| 26 (for burner 5)(Thermal Efficiency) |
- |
5000 |
|
- |
|
Complete
|
|
- |
- - |
| 54 |
IS 12592 (2002) |
Precast concrete manhole cover and frame - Specification (First Revision) |
- |
-
|
11957 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2(Dimensions of cover- Diameter) |
- |
5198 |
|
- |
| 3(Grade) |
- |
520 |
|
Marking |
| 3(Type/Shape of Cover) |
- |
520 |
|
Visual Examination, Shape and Finishing |
| 7.4.1(Edge Protection and Finishing - Frame) |
- |
1271 |
|
- |
| 7.4.2(Edge Protection and Finishing - Cover) |
- |
520 |
|
- |
| 8(LIFTING HOOKS) |
- |
520 |
|
- |
| 9.1(General) |
- |
520 |
|
- |
| 9.3 and Table and
Annex C(Load Test) |
- |
2888 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - A) |
- |
520 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - B) |
- |
520 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - C) |
- |
520 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - D) |
- |
520 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - E) |
- |
520 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - F) |
- |
520 |
|
- |
| 5.2(Clearance at top between the frame and the cover all round the periphery) |
- |
520 |
|
- |
| 5.2(Top surface ofthe frame and cover is in level) |
- |
520 |
|
- |
| 5.2(Suitable taper matching with taper given for the frame shall be provided to the periphery of the cover) |
- |
520 |
|
- |
| 5.2 and Fig 1(Clear cover to reinforcement) |
- |
520 |
|
- |
| Clause No. 7.4.4(Compatitbilty of Seating of cover and frame) |
- |
520 |
|
- |
|
Complete
|
|
- |
- - |
| 55 |
IS 4351 (2003) |
Steel Door Frames - |
- |
-
|
2100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Sizes) |
- |
300 |
|
- |
| 6.2(Tolerances) |
- |
300 |
|
- |
| 6.3(Designation) |
- |
300 |
|
- |
| 7, Table 2(Profile) |
- |
300 |
|
- |
| 7, Table 2(Size, X) |
- |
300 |
|
- |
| 7, Table 2(Size, Y) |
- |
300 |
|
- |
| 7, Table 2(Rebate) |
- |
300 |
|
- |
| 8.0(CONSTRUCTION) |
- |
300 |
|
- |
| 9.0(BASE TIES) |
- |
300 |
|
- |
|
Complete
|
|
- |
- - |
| 56 |
IS 1239 : Part 1 (2004) |
Steel Tubes, Tubulars and Other Wrought Steel Fittings : Part 1 Steel Tubes (BI-LINGUAL) |
- |
-
|
15602 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6.1.1, table1 of IS 1239(Part1)(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
4895 |
|
Chemical Composition |
| 12 AND AS PER IS 4736(MASS OF ZINC COATING) |
- |
1386 |
|
Uniformity and Mass of Zinc coating |
|
Complete
|
|
- |
- - |
| 57 |
IS 2888 (2004) |
Toilet soap - Specification (Third Revision) |
- |
-
|
6450 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.5, Table-1 (vii), Grade-3(Lather) |
- |
500 |
|
- |
| 5.5, Table-1 (vi), Grade-1, Grade-2 & Grade-3(Free carbonated alkali) |
- |
950 |
|
- |
| 5.5, Table-1 (v), Grade-1, Grade-2 & Grade-3(Chloride (as sodium chloride), IS 286) |
- |
950 |
|
- |
| 5.5, Table-1 (iv), Grade-2 & Grade-3(Matter insoluble in alcohol, IS 286) |
- |
950 |
|
- |
| 5.5, Table-1 (iii), Grade-1, Gr-2 & Gr-3(Free caustic alkali, as sodium hydroxide (NaOH), IS 286) |
- |
950 |
|
- |
| 5.5, Table-1 (ii), Grade-1, Gr-2 & Gr-3(Rosin acids, percent by mass of total fatty matter, IS 286 ) |
- |
1050 |
|
- |
| 5.5, Table-1 (i), Grade-3(Total fatty matter, IS 286) |
- |
1350 |
|
- |
| 5.3(Phenolic substances, IS 286) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- - |
| 58 |
IS 15558 (2005) |
Mini domestic water heater for use with LPG - Specification |
- |
-
|
15600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1(Construction) |
- |
300 |
|
- |
| 4.1.2(Construction) |
- |
300 |
|
- |
| 4.1.3(Construction) |
- |
300 |
|
- |
| 4.1.4(Construction) |
- |
300 |
|
- |
| 4.1.5(Construction) |
- |
300 |
|
- |
| 4.1.6(Construction) |
- |
300 |
|
- |
| 4.1.7(Construction) |
- |
300 |
|
- |
| 4.1.8(Construction) |
- |
300 |
|
- |
| 4.1.10(Construction) |
- |
300 |
|
- |
| 4.1.11(Construction) |
- |
300 |
|
- |
| 4.1.12(Construction) |
- |
300 |
|
- |
| 5.1(Materials) |
- |
300 |
|
- |
| 5.2(Materials) |
- |
2500 |
|
- |
| 5.3(Materials) |
- |
300 |
|
- |
| 5.4(Materials) |
- |
300 |
|
- |
| 6.1(Connections) |
- |
300 |
|
- |
| 6.2(Connections) |
- |
300 |
|
- |
| 6.3(Connections) |
- |
300 |
|
- |
| 6.4(Connections) |
- |
300 |
|
- |
| 6.5(Connections) |
- |
300 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
300 |
|
- |
| 7(Flame Visibility) |
- |
300 |
|
- |
| 8(Gas Taps) |
- |
2400 |
|
- |
| 9(Flame Failure Device) |
- |
300 |
|
- |
| 10(Ignition Device) |
- |
300 |
|
- |
| 11(Protection Against Accidental Overheating) |
- |
1000 |
|
- |
| 12(Water Rate Adjuster) |
- |
300 |
|
- |
| 14(Gas Soundness) |
- |
300 |
|
- |
| 15(Water Soundness) |
- |
300 |
|
- |
| 16(Thermal Efficiency) |
- |
1000 |
|
- |
| 17(Combustion) |
- |
300 |
|
- |
| 18(Gas Consumption) |
- |
300 |
|
- |
| 19.2(Ignition and flame travel) |
- |
300 |
|
- |
| 20(Flame Stability) |
- |
300 |
|
- |
| 21(Noise Control) |
- |
300 |
|
- |
| 22(Flash Back) |
- |
300 |
|
- |
| 23(Resistance to Draught) |
- |
300 |
|
- |
| 24(Fire Hazard And Limiting Temperature ) |
- |
1000 |
|
- |
| 24(Fire Hazard And Limiting Temperature) |
- |
1000 |
|
- |
| 24(Fire Hazard And Limiting Temperature) |
- |
1000 |
|
- |
| 24(Fire Hazard And Limiting Temperature) |
- |
1000 |
|
- |
| 25(Time For Temperature Rise) |
- |
1000 |
|
- |
| 26(Hot Water Output Test) |
- |
1000 |
|
- |
| 27(Marking) |
- |
300 |
|
- |
| 16(Thermal Efficiency) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- - |
| 59 |
IS 280 (2006) |
Mild steel wire for general engineering purposes (Fourth Revision) |
Upto 4mm |
-
|
12780 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7 & Table 1(Diameter & Difference Between Two Reading On Any Two Diameters) |
- |
520 |
|
Dimension |
| Cl 9(Tensile Test On UTM) |
- |
1444 |
|
- |
| Cl 13(Workmanship) |
- |
520 |
|
Freedom from defects |
| 6 AND AS PER IS 7887(MICRO ALLOY) |
- |
4895 |
|
Chemical Composition |
| Cl 11(Workmanship) |
- |
2772 |
|
Coating Test |
| 9.2(Wrapping Test) |
- |
1271 |
|
- |
| Cl 9(Tensile Test On UTM) |
- |
1358 |
|
Bend Test |
|
Complete
|
|
- |
- - |
| 60 |
IS 3601 (2006) |
Steel tubes for mechanical and general engineering purposes - Specification (Second Revision) |
- |
-
|
16495 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Sulphur-Percentage by mass) |
- |
3795 |
|
Chemical Composition Test |
| 8.0(Straightness) |
- |
1352 |
|
- |
| 19.1.1, 24.1.1, 28.1.1, 33.1.1(Dimensions- Outside Dia) |
- |
2234 |
|
- |
| 11.2(Surface Protection) |
- |
1386 |
|
- |
| 13.1.3(Tensile Strength) |
- |
1790 |
|
Tensile, Yield Strength and Elongation |
| 13.2(Flattening Test) |
- |
1525 |
|
- |
| 13.3(Bend Test (Strip)) |
- |
1444 |
|
- |
| 13.4(Bend Test (Whole Tube)) |
- |
1444 |
|
- |
| 13.5(Drift Expansion Test) |
- |
1525 |
|
- |
|
Complete
|
|
- |
- - |