| 31 |
IS 12785 (1994) |
Irrigation equipment - Strainer - Type filters - Specification (first revision) |
- |
-
|
8438 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1(General) |
- |
500 |
|
- |
| 4.1.1(General) |
- |
0 |
|
- |
| 4.1.1(Zinc Coating - IS 4736) |
- |
0 |
|
- |
| 4.1.1(General) |
- |
0 |
|
- |
| 4.1.1(General) |
- |
0 |
|
- |
| 4.1.2(General) |
- |
0 |
|
- |
| 4.1.3(General) |
- |
0 |
|
- |
| 4.1.4(General) |
- |
0 |
|
- |
| 4.2.1(Strainer Housing) |
- |
500 |
|
- |
| 4.2.2(Strainer Housing) |
- |
0 |
|
- |
| 4.2.3(Strainer Housing) |
- |
0 |
|
- |
| 4.3.1(Connections
IS 2643 : 1975.) |
- |
500 |
|
- |
| 4.3.2(Connections
IS 6418 : 1971) |
- |
0 |
|
- |
| 4.3.3(Connections) |
- |
0 |
|
- |
| 4.3.4(Connections) |
- |
0 |
|
- |
| 6.1(MECHANiCAL TESTS) |
- |
1500 |
|
- |
| 6.1(MECHANiCAL TESTS) |
- |
0 |
|
- |
| 6.2(MECHANiCAL TESTS ) |
- |
3750 |
|
- |
| 6.3(MECHANiCAL TESTS ) |
- |
1000 |
|
- |
| 6.4(MECHANiCAL TESTS ) |
- |
1000 |
|
- |
| 6.5(MECHANiCAL TESTS ) |
- |
2500 |
|
- |
|
Complete
|
|
31 Dec, 2021 |
- - |
| 32 |
IS 12701 (1996) |
Rotational moulded polyethylene water storage tanks - specification (First Revision) |
- |
-
|
13850 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
250 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
250 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
250 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
250 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
250 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
250 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
250 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
500 |
|
- |
| 5.3(Types and Features ) |
- |
300 |
|
- |
| 5.4(Wall Thickness above effective height) |
- |
250 |
|
- |
| 5.6(Types and Features ) |
- |
250 |
|
- |
| 6.1(Finish) |
- |
300 |
|
- |
| 7.1.1(Resistance to Deformation) |
- |
700 |
|
- |
| 7.2(Resistance to Impact) |
- |
1100 |
|
- |
| 7.4(Tensile Strength) |
- |
1350 |
|
1100+250 |
| 7.5(Flexural Modulus) |
- |
1850 |
|
1100+500 |
| 7.6(overall Migration) |
- |
2200 |
|
1700+500 |
| 9.1(Man-Hole and Hand-Hole Lids) |
- |
1050 |
|
- |
| 9.1(Lid Thickness) |
- |
250 |
|
- |
| 9.2(Man-Hole and Hand-Hole Lids) |
- |
300 |
|
- |
| 9.2.1(Man-Hole and Hand-Hole Lids) |
- |
200 |
|
- |
|
Complete
|
|
31 Dec, 2021 |
- - |
| 33 |
IS 14333 (1996) |
High Density Polyethylene Pipe For Sewerage - |
- |
-
|
8681 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Visual Appearance) |
- |
300 |
|
- |
|
Complete
|
|
31 Dec, 2021 |
- - |
| 34 |
IS 14606 (1998) |
Irrigation equipment - Media filters - Specification |
- |
-
|
10250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4.1(General ) |
- |
500 |
|
- |
| Cl. 4.2(Filter housing) |
- |
500 |
|
- |
| Cl. 4.3(Connections) |
- |
500 |
|
- |
| Cl. 5.1(Resistance of filter to internal hydrostatic pressure ) |
- |
1500 |
|
- |
| Cl. 5.2(Resistance of filter to internal hydrostatic pressure at high temperature) |
- |
3750 |
|
- |
| Cl. 5.3(Pressure drop vs flow testing ) |
- |
2500 |
|
- |
| Cl. 8(Backwash flow ) |
- |
500 |
|
- |
|
Complete
|
|
31 Dec, 2021 |
- - |
| 35 |
IS 14151 : Part 1 (1999) |
Irrigation equipment - Sprinkler pipes - Specification: Part 1 polyethylene pipes (First Revision) |
- |
-
|
14519 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(melt flow rating (MFR) shall not exceed 1.10 g/10 min.) |
- |
1100 |
|
- |
|
Complete
|
|
31 Dec, 2021 |
- - |
| 36 |
IS 14735 (1999) |
Unplasticized Polyvinyl Chloride (UPVC) Injection Moulded Fittings for Soil and Waste Discharge System for Inside and Outside Buildings Including Ventilation and Rain Water System - |
- |
-
|
8131 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Size Designation) |
- |
300 |
|
- |
| 5(Colour of fittings) |
- |
0 |
|
- |
| 7.1,Table 1(Wall thickness) |
- |
500 |
|
- |
| 7.2 ,Table 2&3(Socket Dimensions) |
- |
0 |
|
- |
| 8(Sealing Rings) |
- |
1425 |
|
1050+375 |
| 10(Workmanship) |
- |
300 |
|
- |
| 12.1(Visual appearance) |
- |
300 |
|
- |
| 12.2(Stress relief test) |
- |
700 |
|
- |
| 12.3(Vicat softening tempewrature) |
- |
1100 |
|
- |
| Cl.13, IS 12235 (P-7)-2004, (Resistance to Sulphuric Acid) |
- |
2000 |
|
2000+5000 |
| Cl.14, Annex A(Titanium Di-Oxide Content) |
- |
1200 |
|
- |
| Cl.15, Annex B(Sulphated Ash Content) |
- |
950 |
|
- |
| 16.1(Impact test) |
- |
1100 |
|
- |
| 17(Watet tightness of joint) |
- |
850 |
|
- |
|
Complete
|
|
31 Dec, 2021 |
- - |
| 37 |
IS 14743 (1999) |
Irrigation equipment - Hydrocyclone filters - Specification |
- |
-
|
7313 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1(TECHNICAL REQUIREMENTS - Material) |
- |
500 |
|
- |
| 4.1.1(TECHNICAL REQUIREMENTS - Material) |
- |
0 |
|
- |
| 4.1.1(TECHNICAL REQUIREMENTS - Material) |
- |
0 |
|
- |
| 4.1.2(TECHNICAL REQUIREMENTS - Material) |
- |
0 |
|
- |
| 4.1.2(TECHNICAL REQUIREMENTS - Material) |
- |
0 |
|
- |
| 4.2.1(Construction) |
- |
500 |
|
- |
| 4.2.2(Construction) |
- |
0 |
|
- |
| 4.3.1(Cyclonic Vessel) |
- |
500 |
|
- |
| 4.3.2(Cyclonic Vessel) |
- |
0 |
|
- |
| 4.3.3(Cyclonic Vessel) |
- |
0 |
|
- |
| 4.3.4(Cyclonic Vessel) |
- |
0 |
|
- |
| 4.3.5(Cyclonic Vessel) |
- |
0 |
|
- |
| 4.4.1(Connections
IS 554.) |
- |
500 |
|
- |
| 4.4.2(Connections
IS 6392.) |
- |
0 |
|
- |
| 4.4.3(Connections) |
- |
0 |
|
- |
| 5.1(Resistance to Internal Hydrostatk Pressure) |
- |
1500 |
|
- |
| 5.2(Resistance to Internal Hydrostatk Pressure at Elevated Temperatures) |
- |
3750 |
|
- |
| 5.3(Pressure Drop vs Flow) |
- |
2500 |
|
- |
|
Complete
|
|