| 1 |
IS 10702 (1992) |
Rubber hawal chappal - Specification (Second Revision) |
- |
-
|
8750 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.4(Stud bolt) |
- |
100 |
|
- |
| 5.4(Stud diameter) |
- |
250 |
|
- |
| 5.4(Tear strength ) |
- |
600 |
|
- |
| 5.4(Hardness (shore A)- after ageing) |
- |
500 |
|
- |
| 5.4(Breaking strength ) |
- |
700 |
|
- |
| 5.4(Elongation at break ) |
- |
400 |
|
- |
| 5.4(Tensile Strength ) |
- |
700 |
|
- |
| 5.4(Relative density ) |
- |
400 |
|
- |
| 5.4(Shrinkage test (at 100 C temp)) |
- |
800 |
|
- |
| 5.4(Shrinkage test (at room temp)) |
- |
800 |
|
- |
| 5.4(Split tear strength ) |
- |
600 |
|
- |
| 5.4(Compression set) |
- |
1200 |
|
- |
| 5.4(Hardness (Shore A)) |
- |
400 |
|
- |
| 5.4(Relative density) |
- |
400 |
|
- |
| 5.3(Thickness ) |
- |
250 |
|
- |
| 5.1(Shape & Design) |
- |
250 |
|
- |
| 5.4(Hardness (Shore A)) |
- |
400 |
|
- |
|
Complete
|
|
- |
- - |
| 2 |
IS 3735 (1996) |
Canvas Shoes, Rubber Sole |
- |
-
|
19300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Conductor : Material ) |
- |
200 |
|
- |
| 5(SEPARATOR) |
- |
200 |
|
- |
| 6(COVERING) |
- |
200 |
|
- |
| 7(CONDUCTOR : CONSTRUCTION ) |
- |
400 |
|
- |
| 8(S E P A R A T O R) |
- |
400 |
|
- |
| 9.1(C O V E R I N G : Application ) |
- |
200 |
|
- |
| 9.2(T h i c k n e s s o f C o v e r i n g) |
- |
200 |
|
- |
| 9.3(T o l e r a n c e on Thickness o f C o v e r i n g) |
- |
200 |
|
- |
| 9.4(A p p l i c a t i o n of C o v e r i n g) |
- |
200 |
|
- |
| 9.5(Colour of C o v e r i n g) |
- |
200 |
|
- |
| 10.1 a) 1)(Annealing test - IS 10810: Part 1) |
- |
300 |
|
- |
| 10.1 a) 2)(Conductor resistance tes - IS 10810 : Part 5) |
- |
200 |
|
- |
| 10.1 c) 1)(Physical tests for
covering : Tensile strength ) |
- |
200 |
|
- |
| 10.1 c) 1)(Physical tests for
covering : Elongation at break ) |
- |
200 |
|
- |
| 10.1 c) 2)(Physical tests for
covering - Ageing in Air oven : Tensile strength variation) |
- |
200 |
|
- |
| 10.1 c) 2)(Physical tests for
covering - Ageing in Air oven : Tensile strength ) |
- |
200 |
|
- |
| 10.1 c) 2)(Physical tests for
covering -Ageing in Air oven : Elongation variation at break ) |
- |
200 |
|
- |
| 10.1 c) 3)(Physical tests for
covering - Ageing in Air Bomb : Tensile strength variation ) |
- |
100 |
|
- |
| 10.1 c) 3)(Physical tests for
covering -Ageing in Air Bomb : Elongation variation at break ) |
- |
100 |
|
- |
| 10.1 c) 4)(Physical tests for
covering - Oil Resistance : Tensile strength variation ) |
- |
100 |
|
- |
| 10.1 c) 5)(Hot set test ) |
- |
200 |
|
- |
| 10.1 c) 5)(Permanent set ) |
- |
200 |
|
- |
| 11.1(High Voltage Test ( Water Immersion
Test )) |
- |
400 |
|
- |
| 11.2(Spark Test) |
- |
200 |
|
- |
| 11.3(Static Flexibility Test) |
- |
150 |
|
- |
| 11.4(Flammability Test) |
- |
150 |
|
- |
| 12.1(Manufacturer's Identification) |
- |
50 |
|
- |
| 12.2(Cable Identification) |
- |
50 |
|
- |
| 12.3(Cable Code) |
- |
50 |
|
- |
| 13.1(Packing ) |
- |
50 |
|
- |
| 13.2(Marking) |
- |
50 |
|
- |
| 14(CABLE RATINGS) |
- |
50 |
|
- |
| 15(VOLTAGE DROP) |
- |
200 |
|
- |
| 4.1.1 Upper, Sl No. (i) of Table 1(The upper shall consist of over layer of cotton, manmade or blended
conforming' to the requirements given in Sl No. (i) of Table 1 as an overlayer and cotton drill conforming to the
requirements given in Sl No. (ii) of Table 1, as an inner layer or lining. The two fabrics shall be firmly adhered together with rubber compound. ) |
- |
800 |
|
- |
| Cl.4.1.1.1 Colour fastness(The dyed fabrics prescribed in 4.1.1 shall be fast todaylight and mechanical washing. Fastness to daylight
shall be of rating 4 or better, when tested in accordance with IS 686 : 1985 or IS 2454: 1985. However in case of dispute the method prescribed in IS 686 : 1985
shall be considered as referee method.) |
- |
1000 |
|
- |
| 4.1.1.2(Colorfastness to washing) |
- |
1000 |
|
- |
| Cl.4.1.2 Binding Material(IS 1954 : 1990)
(IS1969 : 1985)(Cotton tape NEWAR used as binding material shall conform to the requirements prescribed in col 3 of
Table 2, when tested in accordance with the methods referred to in col 4 of the table.) |
- |
1050 |
|
- |
| Cl.4.1.2.1
Anmex B.(Cotton, manmade or blended shall be used as binding material.'
'Coloured cotton tapes shall have fastness to day light of rating as and if agreed
to between the purchaser and the supplier when tested in accordance with IS 686 :
1985. The black tapes shall be free from sulphur dyes when tested in accordance
with Annex B.') |
- |
1000 |
|
- |
| 4.1.3(Single thread breaking load) |
- |
500 |
|
- |
| Cl.4.1.3.1( Sewing thread cotton, manmade or blended shall be used for stitching of
upper. For cotton variety thread shall conform to variety No. 28 of IS 1720.
Polyester variety thread shall conform to variety No. 9 of IS 9543. Any other suitable thread shall have breaking load not less than above referred
requirement of specification.
Sewing thread cotton, manmade or blended shall be used for binding of upper. For cotton variety thread shall conform to variety No. 32 of IS 1720. Polyester variety thread shall conform to variety No. 5 of IS 9543.
Any other suitable thread shall have breaking load not less than above referred
requirement of specification.') |
- |
500 |
|
- |
| Cl.4.1.3.2 (IS 2454 : 1985)
IS 765 : 1979
IS 971 : 1966( The colour of the threads shall be as agreedto between the purchaser and the supplier. The dyed threads shall conform to the following requirements or IS 686 : 1985'.) |
- |
2800 |
|
- |
| Cl.4.1.4(.Brass, steel or aluminium eyelets of 7.5 mm diameter and wall thickness 0.30 to
0.35 mm shall be used.') |
- |
1000 |
|
- |
| Cl.4.1.5 Laces(
The shoes shall be provided with fabric braided laces
either matching the shade of the upper or black or The length of the lace shall be 60 ± 3 cm ) |
- |
1500 |
|
- |
| Cl.4.1.6 Rubber Components(The rubber components shall conform to the requirements given in Table 4, when tested from finished boots.However in case it is not possible to cut the test pieces from the made up boots then 4.1.5.3 of IS
13695 : 1993 shall be followed.') |
- |
3300 |
|
- |
| Cl.4.1.6.2 Ageing
col 4 of Table 5.(The shoes shall be also aged at 70 ± 1°C for 168 h, on completion of which the test pieces taken from the shoes shall conform to the physical requirements
prescribed in col 4 of Table 5. ) |
- |
2500 |
|
- |
| Cl.4.1.6.3 Thickness of components
in Table 6.(Individual components of the shoes shall comply with
the thickness and material requirements prescribed
in Table 6.) |
- |
250 |
|
- |
| Cl.4.3 Construction
Cl 4.3.1( The upper shall be stitched on a lock stitch machine and the number of stitches shall be 30 to
40 per dm.) |
- |
0 |
|
- |
| Cl.4.3.8( A rubber foxing shall be fixed all round the sole and heel. The colour shall be as agreed to between the purchaser and the supplier. ) |
- |
250 |
|
- |
| Cl.4.4 Adhesion Test(From the upper-foxing portion where it is adhered to the canvas, parallel to the waist of sole, cut a strip of length 100 mm and width 8 mm. Separate out
the plies initially by breaking the bond to a length of about 75 mm. Carry out the test on two specimens in accordance with IS 3400 (Part 5) : 1986. There
shall be no further separation within 1 minute at a load of 1 kg for each of the two specimens.) |
- |
800 |
|
- |
| Cl.4.5 Consolidation Test
IS 3400 (Part 5) : 1986 (From the quarter, cut a strip of 25.0 ± 0.5 mm width along the leagth of the boot
and of sufficient length to permit separation over a length of 75 mm. Carry out the test on two test pieces (one from each odd) at the rate of traverse of 100± 10mm per minute in accordance with IS 3400 (Part 5): 1986 or Static Dead Load
Method as given in Annex C. The individual adhesion value for consolidation test shall not be less than 30N (3.0 kgf) for each of the teat piecea (see Note
under 4.4).') |
- |
800 |
|
- |
| CL.4.6 Mass(The mass of one pair of finished shoes of size 8 shall not exceed 750 g with an increase or decrease of 25 g for each bigger or smaller size respectively) |
- |
250 |
|
- |
|
Complete
|
|
- |
- - |
| 3 |
IS 3736 (1995) |
Canvas boots, rubber sole - Specification (Second Revision) |
- |
-
|
0 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Phase/Street Lighting conductor) |
- |
0 |
|
- |
| 4.2(Messenger (Neutral Conductor or Otherwise)) |
- |
0 |
|
- |
| 5.1(Insulation) |
- |
0 |
|
- |
| 6.1(Flexibility class) |
- |
0 |
|
- |
| 6.2(Compactness) |
- |
0 |
|
- |
| 6.2(No of strands) |
- |
0 |
|
- |
| 6.2(Surface) |
- |
0 |
|
- |
| 6.3(Protective barrier) |
- |
0 |
|
- |
| 6.4(size of street lighting conductor) |
- |
0 |
|
- |
| 6.5(Size of messenger conductor ) |
- |
0 |
|
- |
| 6.6(Joints in messenger conductor ) |
- |
0 |
|
- |
| 6.6(Direction of outer layer) |
- |
0 |
|
- |
| 7.1(Insulation) |
- |
0 |
|
- |
| 7.2( Thickness of insulation) |
- |
0 |
|
- |
| 7.3(Tolerance on thickness of insulation ) |
- |
0 |
|
- |
| 7.4(Aplication of the insulation ) |
- |
0 |
|
- |
| 7.5(Colour of the insulation ) |
- |
0 |
|
- |
| 8.1(Core identification) |
- |
0 |
|
- |
| 9.2(Assembly (Laying up)) |
- |
0 |
|
- |
| 10.1 a) i)(Tests on phase/street light conductor: tensile test - Test method IS10810:Part 2) |
- |
0 |
|
- |
| 10.1 a) ii)(Wrapping test - 10810: Part 3) |
- |
0 |
|
- |
| 10.1 a) iii)(Resistance test - IS10810: Part 5) |
- |
0 |
|
- |
| 10.1 b) i)(Test on messenger conductor: Breaking load - IS 10810: Part 2) |
- |
0 |
|
- |
| 10.1 b) ii)(Test on messenger conductor: Elongation test - Cl 11.3) |
- |
0 |
|
- |
| 10.1 b) iii)(Test on messenger conductor: Resistance test - IS 10810: Part 5) |
- |
0 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
Tensile strength - IS 10810: Part 7) |
- |
0 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
elongation at break - IS 10810: part 7) |
- |
0 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Tensile strength variation - IS 10810:Part 11) |
- |
0 |
|
- |
| 10.1 c) iii)(Hot set test: Elongation under load - IS 10810: Part 30) |
- |
0 |
|
- |
| 10.1 d) i)(Physical test for PE insulation:
Tensile strength - IS 10810: Part 7 ) |
- |
0 |
|
- |
| 10.1 d) ii)(Melt flow index- IS 10810: Part 23) |
- |
0 |
|
- |
| 10.1 d) iv)(Vicat softening point -IS 10810: Part 22) |
- |
0 |
|
- |
| 10.1 d) v)(Environmental stress cracking -IS 10810:Part29) |
- |
0 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test a) volume resistivity at 27°C - IS 10810: Part 43) |
- |
0 |
|
- |
| 10.1 g)(High voltage test - IS10810:Part 45) |
- |
0 |
|
- |
| 11.4(Bending Test on the Completed Cable ( Optional) ) |
- |
0 |
|
- |
| Cl.4.1.1 upper IS 1969(Breaking load in
N.Min (5 × 20 cm grip): a) Wrap) |
- |
1000 |
|
- |
| 4.1.1.1 Colour fastness(The dyed fabrics prescribed in 4.1.1 shall be fast to daylight and mechanical washing. Fastness to daylight
shall be of rating 4 or better, when tested in accordance with IS 686 : 1985 or IS 2454 : 1985.) |
- |
2000 |
|
- |
| Cl.4.1.1.2( Fastness to mechanical washing (mild) shall be of rating 4 or better, when tested in accordance with IS 764 : 1979) |
- |
2000 |
|
- |
| 4.1.2 Lining Material( 200 N Minin weft way (when tested in accordance with IS 1969 : 1985) ) |
- |
600 |
|
- |
| Cl.4.1.3 Binding Material
IS 1954:1990(Cotton tape NEWAR used as binding material shall conform to the requirements as mentioned in
Table 2, when tested in accordance with the methods referred to in col 4 of Table 2.
1)Width, mm. Min
) |
- |
250 |
|
- |
| Cl.4.1.3 Binding Material
IS 1954:1990(Cotton tape NEWAR used as binding material shall conform to the requirements as mentioned in
Table 2, when tested in accordance with the methods referred to in col 4 of Table 2.
1)Width, mm. Min
) |
- |
800 |
|
- |
| Cl.4.1.3 Binding Material
IS 1954:1990(Cotton tape NEWAR used as binding material shall conform to the requirements as mentioned in
Table 2, when tested in accordance with the methods referred to in col 4 of Table 2.
1)Width, mm. Min
) |
- |
0 |
|
- |
| Cl.4.1.3.3( Black tapes shall be free from sulphur dyes when tested in accordance with Annex B.) |
- |
850 |
|
- |
| Cl.4.1.4 Reinforcement Material(The back seam, joining two quarters at the back of the heel shall be reinforced with a not less than 25 mm wide tape made out of material conforming
to Sl No. (i) of Table 1) |
- |
850 |
|
- |
| Cl.4.1.5 Thread for Upper Closing
Cl.4.1.5.1 (IS 1670:1991)(Sewing thread cotton, man made or blended shall be used for stitching
of upper. For cotton variety thread shall conform to variety No. 28 of IS 1720.
Polyester variety thread shall conform to variety No. 9 of IS 9543.
Any other blend of thread would have breaking load not less than above referred
requirements.
Sewing thread cotton, manmade or blended shall be used for binding of upper.
For cotton variety thread shall conform to variety No. 32 of IS 1720. Polyester
variety thread shall conform to variety No. 5 of IS 9543.
Any other blend of thread would have breaking load not less than above referred
requirement of specification.') |
- |
500 |
|
- |
| Cl.4.1.5.2( The colour of the threads shall be asagreed to between the purchaser and the supplier. The dyed threads shall conform to the following requirements) |
- |
2000 |
|
- |
| Cl.4.1.5.2( The colour of the threads shall be asagreed to between the purchaser and the supplier. The dyed threads shall conform to the following requirements) |
- |
800 |
|
- |
| 4.1.6 Fabric Laces
Cl.4.1.6.1( The boots shall be provided with braided of cotton or man made or blended fabric laces 115 ± 5 cm in length, matching the colour of the upper. ) |
- |
1000 |
|
- |
| 4.1.6 Fabric Laces
Cl.4.1.6.1( The boots shall be provided with braided of cotton or man made or blended fabric laces 115 ± 5 cm in length, matching the colour of the upper. ) |
- |
1000 |
|
- |
| 4.1.6 Fabric Laces
Cl.4.1.6.1(The two ends of the lace shall
be provided with suitable metal or plastic tips. Black laces shall be free from sulphur dyes when tested in accordance with Annex B.) |
- |
900 |
|
- |
| Cl.4.1.7 Rubber Components
Cl.4.1.7.1( the soles and heels shall conform to Type 2 of IS 5676:1995.) |
- |
250 |
|
- |
| Cl.4.1.7.2
IS 3400 (Part 9) : 1978( The rubber components shall conform to Table 4 when tested.'
( Page 3, Table 4, Note 1) —
'However in case it is not possible then 4.2.5.3 of IS 13695:1993 shall be followed.
1)Relative density, Max) |
- |
250 |
|
- |
| Cl.4.1.7.3
IS 3400 (Part 10) : 1977(Compression set, in percent. Max) |
- |
600 |
|
- |
| Cl.4.1.7.3
IS 3400 (Part 10) : 1977(Compression set, in percent. Max) |
- |
2000 |
|
- |
| Cl.4.1.7.4 Ageing(The boots shall be also aged at 70 ± 1°C for 168 h, on completion of which the test pieces taken from the soles and heels of the boots shall conform to the physical requirements prescribed in Table 5.
i) Tensile Length) |
- |
1000 |
|
- |
| Cl.4.1.7.5 Thickness of components(Individual components of the boots shall comply with the thickness and material requirements prescribed
in Table 6.) |
- |
250 |
|
- |
| Cl.4.3 Leg Height(The leg height of the boots for size 8 shall be 160 ± 2 mm with an increase or decrease of 4 mm of the nominal height for each bigger or smaller sizes respectively when measured at the inside from the back of the boot from insole to the top.) |
- |
250 |
|
- |
| Cl.4.4.10( A 25 mm Min wide and 2 mm Min thick
rubber golosh in serrated, diamond or any otherdesign, as agreed to between the purchaser and thesupplier, shall be fitted all round the sole edge of
the boot. The golosh shall not extend below the edge of the sole.) |
- |
250 |
|
- |
| Cl.4.5.1(Cl.4.1.6.)( Each pair of boot shall be provided with a pair of braided fabric laces of the quality as prescribed
in 4.1.6.) |
- |
250 |
|
- |
| Cl.4.6 Mass(The mass of finished boots, rubber sole, of size 8 shall not exceed 1130 g per pair, and the mass shall increase or decrease by 75 g per pair for each bigger or smaller size respectively.) |
- |
250 |
|
- |
| Cl.4.7 Consolidation Test(From the quarter, cut a strip of 25.0 ± 0. 5 mm width along the length of the boot
and of sufficient length to permit separation over a length of 75 mm. Carry out the test on two test pieces (one from each odd) at the rate of traverse of 100 ± 10mm per minute in accordance with IS 3400 (Part 5): 1986 or Static Dead Load
Method as given in Annex C. The individual adhesion value for consolidation
test shall not be less than 30 N (3.0 kgf) for each of the test pieces) |
- |
500 |
|
- |
| Cl.4.8 Adhesion Test(From the upper foxing portion where it is adhered to the canvas cut a strip of
8.0 ± 0.5 mm width along with the length of the sole at the waist portion and of
sufficient lengh to permit separation over a length of at least 75 mm. Carry out
the test on two test pieces (one from each odd) at the rate of traverse of 100 ± 10
mm per minute in accordance with IS 3400 (Part 5):1986 or the Static Dead
Load Method as given in Annex C.
The individual adhesion value noted/recorded shall not be less than 8 N (0.8 kgf)
for each of the test pieces ( see Note under 4.7 ).') |
- |
500 |
|
- |
|
Complete
|
|
- |
- - |
| 4 |
IS 5557 (2004) |
Industrial and protective rubber knee and ankle boots - Specification (Fourth Revision) |
- |
-
|
19400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(MATERIALS : CONDUCTOR) |
- |
0 |
|
- |
| 4.1.1(INSULATION : General Purjose Insulaiion) |
- |
0 |
|
- |
| 4.1.2(INSULATION : Heat Resisting Insulation) |
- |
0 |
|
- |
| 5.1(MATERIALS : FILLER AND INNER SHEATH) |
- |
0 |
|
- |
| 5.2(MATERIALS : FILLER AND INNER SHEATH) |
- |
0 |
|
- |
| 6.1(MATERIALS : ARMGURING) |
- |
0 |
|
- |
| 6.2(MATERIALS : ARMGURING) |
- |
0 |
|
- |
| 8.1(CONSTRUCTION : CONDUCTOR) |
- |
0 |
|
- |
| 9.1(INSULATION ) |
- |
0 |
|
- |
| 10.1(CORE IDENTIFICATION) |
- |
0 |
|
- |
| 11.1(LAYING UP OF CORES) |
- |
0 |
|
- |
| 12.1(INNER SHEATH) |
- |
200 |
|
- |
| 12.3(INNER SHEATH :Thickness of Inner Sheath) |
- |
0 |
|
- |
| 13.1.1(ARMOURING : Application) |
- |
0 |
|
- |
| 13.2(ARMOURING : Type of Armour) |
- |
0 |
|
- |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
0 |
|
- |
| 13.4(ARMOURING : Joints) |
- |
0 |
|
- |
| 13.5.1(ARMOURING : Resistance) |
- |
0 |
|
- |
| 14.1(OUTER SHEATH) |
- |
0 |
|
- |
| 14.2(OUTER SHEATH) |
- |
0 |
|
- |
| 14.3(OUTER SHEATH : Colour ) |
- |
0 |
|
- |
| 14.4.1(Thickness of Outer Sheath : Unarmowed Cables) |
- |
0 |
|
- |
| 15.1 a) 1)(Tests on conductor : Annealing test ( for copper )) |
- |
0 |
|
- |
| 15.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
0 |
|
- |
| 15.1 a) 3)(Tests on conductor : Wrapping test ( for aluminium )) |
- |
0 |
|
- |
| 15.1 a) 4)(Tests on conductor : Conductor resistance test) |
- |
0 |
|
- |
| 16.2(DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
0 |
|
- |
| 16.3.1(High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
0 |
|
- |
| 16.3.2(High Voltage Test ( Water Immersion Test ) : d.c. Test) |
- |
0 |
|
- |
| 16.4(Flammability Test) |
- |
0 |
|
- |
| 5/5.1.1-Fig. 1, Fig. 2 and Fig. 3(REQUIREMENTS-Design) |
- |
250 |
|
- |
| 5/5.1.2 -IS 1638(REQUIREMENTS-Size) |
- |
150 |
|
- |
| 5/5.1.3-Table1(REQUIREMENTS-Thickness) |
- |
250 |
|
- |
| 5/5.1.4/5.1.4.1-Table2(REQUIREMENTS-Materials-Rubber components) |
- |
4000 |
|
- |
| 5/5.1.4/5.1.4.2(REQUIREMENTS-Materials-Fabric-
accordance with IS 1969) |
- |
1800 |
|
- |
| 5/5.1.4/5.1.4.3(REQUIREMENTS-Materials-Protective Steel Toe Cap-
an per IS 5852) |
- |
1500 |
|
- |
| 5/5.1.6/5.1.6.1-Fig. 1,
Fig. 2, Fig. 3, .Fig. 4, Fig. 5 and Table 3.(REQUIREMENTS- Construction) |
- |
0 |
|
- |
| 5/5.1.7/5.1.7.1(REQUIREMENTS- Physical Requirements-Heat treatment-
as per IS 3400 (Part 4)) |
- |
800 |
|
- |
| 5/5.1.7/5.1.7.2(REQUIREMENTS- Physical Requirements-Composite strength) |
- |
1400 |
|
- |
| 5/5.1.7/5.1.7.3-Table 4(REQUIREMENTS- Physical Requirements-Flexing endurance-
as per Annex B.) |
- |
4800 |
|
- |
| 5/5.1.7/5.1.7.4(REQUIREMENTS- Physical Requirements- Leakage resistance test) |
- |
1000 |
|
- |
| 5/5.1.7/5.1.7.5(REQUIREMENTS- Physical Requirements- Consolidation test-
as per IS IS 3400 (Part 5)) |
- |
1000 |
|
- |
| 5/5.1.7/5.1.7.6(REQUIREMENTS- Physical Requirements- Performance test-
as per Annex C) |
- |
1000 |
|
- |
| 5/5.1.7/5.1.7.7(REQUIREMENTS- Physical Requirements-Height of the boots) |
- |
250 |
|
- |
| 5/5.1.7/5.1.7.8(REQUIREMENTS- Physical Requirements-Resistance to oil) |
- |
1200 |
|
- |
|
Complete
|
|
- |
- - |
| 5 |
IS 5676 (1995) |
Moulded solid rubber soles and heels - SpecificatlOn (Second Revision) |
- |
-
|
2200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Freedom from Defects) |
- |
200 |
|
- |
| 7.1 Table-1(Dimensional measurement of wires) |
- |
200 |
|
- |
| 7.2.2 Table-2, Table-4(Calculated resistance of Stranded Conductor ) |
- |
200 |
|
- |
| 8.1(Joints in wires-Conductors Containing Seven Wires) |
- |
300 |
|
- |
| 9.1(Stranding) |
- |
300 |
|
- |
| 9.2 Table 3(Lay Ratio of stranded conductors) |
- |
100 |
|
- |
| 9.3(Direction of Lay) |
- |
100 |
|
- |
| 9.4(Multiple layers of wires) |
- |
100 |
|
- |
| 11(Packing and Marking) |
- |
100 |
|
- |
| 12.2 Table 1(Breaking Load Test- Before Stranding) |
- |
100 |
|
- |
| 12.3 Table 1(Elongation Test- Before Stranding) |
- |
100 |
|
- |
| 12.2 Table 1(Breaking Load Test- After Stranding) |
- |
100 |
|
- |
| 12.3 Table 1(Elongation Test- After Stranding) |
- |
100 |
|
- |
| 12.4 Table 1(Resistance of Aluminium wire) |
- |
200 |
|
- |
|
Complete
|
|
- |
- - |
| 6 |
IS 6664 (1992) |
Rubber microcellular sheets for soles and heels - Specification (First Revision) |
- |
-
|
4000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires Before Stranding) |
- |
200 |
|
- |
| 8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires Before Stranding) |
- |
100 |
|
- |
| 8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires After Stranding) |
- |
200 |
|
- |
| 8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires After Stranding) |
- |
200 |
|
- |
| 10 (elec)(Stranding) |
- |
350 |
|
- |
| 13.3 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
300 |
|
- |
| 13.3 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
300 |
|
- |
| 13.3 Table 1 (mech)(Breaking Load of Aluminium Wires After Stranding) |
- |
300 |
|
- |
| 13.3 Table 2 (mech)(Breaking Load of Steel Wires After Stranding) |
- |
200 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
200 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
200 |
|
- |
| 13.4.2 (elec)(Ductility by Elongation Test before stranding) |
- |
200 |
|
- |
| 13.4.2 (elec)(Ductility by Elongation Test after stranding) |
- |
200 |
|
- |
| 13.5.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
150 |
|
- |
| 13.5.1 (mech)(Wrapping Test Aluminium Wires After Stranding) |
- |
100 |
|
- |
| 13.5.2 (mech)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
100 |
|
- |
| 13.5.2 (mech)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
100 |
|
- |
| 13.6 (elec)(Resistance test-Aluminium wire before Stranding) |
- |
100 |
|
- |
| 13.6 (elec)(Resistance test-Aluminium wire after stranding) |
- |
100 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
100 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
100 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
100 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
100 |
|
- |
|
Complete
|
|
- |
- - |
| 7 |
IS 6719 (1972) |
Solid Pvc Soles And Heels |
- |
-
|
2000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 12.2, Table-1(Measurement of diameter of individual aluminium wire) |
- |
200 |
|
- |
| 12.3, Table-1(Breaking load before stranding) |
- |
200 |
|
- |
| 12.3, Table-1(Breaking load after stranding) |
- |
200 |
|
- |
| 12.4(Wrapping test) |
- |
200 |
|
- |
| 12.5, Table 1(Resistance test) |
- |
300 |
|
- |
| 12.6, Table 3(Measurement of lay ratio) |
- |
300 |
|
- |
| 9.3(Stranding) |
- |
300 |
|
- |
| 6(Freedom from defects) |
- |
300 |
|
- |
|
Complete
|
|
- |
- - |
| 8 |
IS 6721 (1972) |
Specification for PVC sandal |
- |
-
|
3050 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.3.1 (Conductor) |
- |
400 |
|
- |
| Cl.4(Material) |
- |
400 |
|
- |
| Cl.5.1.1 (Dimensions) |
- |
400 |
|
- |
| Cl. 6(Annealing Test) |
- |
600 |
|
- |
| Cl 6(Resistance Test) |
- |
600 |
|
- |
| Cl 4.1.2 (Visual examination) |
- |
500 |
|
- |
| Cl.3.2(Dielectric Material ) |
- |
400 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
600 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Tensile strength ) |
- |
500 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Elongation) |
- |
500 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Shrinkage test ) |
- |
500 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Water absorption (Gravimetric) ) |
- |
400 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Hot deformation Test ) |
- |
600 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Heat shock Test ) |
- |
600 |
|
- |
| 4.0(Density ) |
- |
400 |
|
- |
| 4.0(Hardness (IRHD)) |
- |
400 |
|
- |
| 4.0(Tensile Strength ) |
- |
500 |
|
- |
| 4.0(Elongation at break ) |
- |
0 |
|
- |
| 4.0(Tear strength ) |
- |
500 |
|
- |
| 4.0(Volatility % by mass) |
- |
500 |
|
- |
| 4.0(Lead Content ) |
- |
500 |
|
- |
| 4.4(Dimension) |
- |
250 |
|
- |
|
Complete
|
|
- |
- - |
| 9 |
IS 12254 (1993) |
Polyvinyl chloride (PVC) Industrial boots - Specification (First Revision) |
- |
-
|
9650 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(CONDUCTOR: MATERIALS) |
- |
0 |
|
- |
| 4(INSULATION : MATERIALS) |
- |
0 |
|
- |
| 5.1(FILLER AND INNER SHEATH) |
- |
0 |
|
- |
| 5.2(FILLER AND INNER SHEATH) |
- |
0 |
|
- |
| 6(ARMOURING) |
- |
0 |
|
- |
| 7(OUTER SHEATH) |
- |
0 |
|
- |
| 8.1(CONDUCTOR: CONSTRUCTION) |
- |
0 |
|
- |
| 8.2(PROTECTIVE BARRIER) |
- |
0 |
|
- |
| 9.1(Insulation Applied by extrusicn) |
- |
0 |
|
- |
| 9.2(Thickness of Insulation - Average) |
- |
0 |
|
- |
| 9.3(Thickness of Insulation - Minimum) |
- |
0 |
|
- |
| 9.4(Application of Insulation) |
- |
0 |
|
- |
| 10.1(Core Identification) |
- |
0 |
|
- |
| 10.2(Core Identification- Neutral) |
- |
0 |
|
- |
| 10.3(Core Identification by number ) |
- |
0 |
|
- |
| 10.4(Core Identification by number - Neutral ) |
- |
0 |
|
- |
| 11(LAVING UP OF CORES) |
- |
0 |
|
- |
| 12.1 & 12.2(Inner sheath : Application) |
- |
0 |
|
- |
| 12.3(Thickness of Inner Sheath) |
- |
0 |
|
- |
| 13.1(Armouring: Application) |
- |
0 |
|
- |
| 13.2(Type of armour ) |
- |
0 |
|
- |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
0 |
|
- |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
0 |
|
- |
| 13.4(Armour: Joint) |
- |
0 |
|
- |
| 13.5(Armouring : Resistance Test) |
- |
0 |
|
- |
| 14.1(Outer Sheath : Application) |
- |
0 |
|
- |
| 14.2(Colour of outer sheath) |
- |
0 |
|
- |
| 14.3(Thickness of outer sheath - AVERAGE) |
- |
0 |
|
- |
| 15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
0 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
0 |
|
- |
| 15.1 a) iii)(Wrapping test (for aluminium)) |
- |
0 |
|
- |
| 15.1 a) iv)(Resistance test - Main conductor) |
- |
0 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
0 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
0 |
|
- |
| 15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
0 |
|
- |
| 15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
0 |
|
- |
| 15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
0 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
0 |
|
- |
| 15.1 e) v) (Sheath : Hot deformation) |
- |
0 |
|
- |
| 15.1 e) vi) (Sheath : Heat shock test) |
- |
0 |
|
- |
| 15.1 e) vii) (Sheath : Thermalstability) |
- |
0 |
|
- |
| 15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
0 |
|
- |
| 16.2(HIGH VOLTAGE TEST ) |
- |
0 |
|
- |
| 16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
0 |
|
- |
| 17.1(Manufacturer'. ldeadentificatioa) |
- |
0 |
|
- |
| 5.1(Shape & Design) |
- |
250 |
|
- |
| 5.2(Soling pattern ) |
- |
250 |
|
- |
| 5.3(Thickness ) |
- |
250 |
|
- |
| 5.4 Table 2(Hardness, IS 12240 (Part 2)) |
- |
800 |
|
- |
| 5.5(Relative Density) |
- |
800 |
|
- |
| 5.6(Volatility
) |
- |
1000 |
|
- |
| 5.7(Lead contect ) |
- |
1000 |
|
- |
| 5.8(Tensile Strength ) |
- |
800 |
|
- |
| 5.9(Resistance to Cut Growth (Flexing test) for Sole, IS 12240 (Part 7)) |
- |
800 |
|
- |
| 5.10(resistance to flexing for upper ) |
- |
800 |
|
- |
| 5.11(Leg Height, IS 12240 (part 9)) |
- |
250 |
|
- |
| 5.12(Leakage resistance) |
- |
800 |
|
- |
| 5.13(Cold Flex Temperature) |
- |
800 |
|
- |
| 5.14(Finish) |
- |
250 |
|
- |
| 5.15(Performance) |
- |
800 |
|
- |
|
Complete
|
|
- |
- - |
| 10 |
IS 16333 : Part 3 (2017) |
Mobile phone handsets: Part 3 indian language support for mobile phone handsets - Specific requirements (First Revision) |
- |
-
|
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Inputting of text) |
- |
7500 |
|
- |
| 5.2(Message Readability) |
- |
7500 |
|
- |
|
Complete
|
|
- |
- - |
| 11 |
IS 15644 (2006) |
Safety of electric toys |
- |
-
|
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.0(Marking and instructions) |
- |
1000 |
|
- |
| 8.0(Power Input) |
- |
2500 |
|
- |
| 9.0(Heating and abnormal operation) |
- |
1500 |
|
- |
| 10.0(Electrical strength at operating temperature) |
- |
1500 |
|
- |
| 11.1(Moisture resistance) |
- |
1000 |
|
- |
| 11.2(Resistant to humidity) |
- |
1000 |
|
- |
| 12.0(Electric strength at room temperature) |
- |
1500 |
|
- |
| 13.0(Mechanical strength) |
- |
1500 |
|
- |
| 14.1(Construction) |
- |
1500 |
|
- |
| 15.1(Protection of cords and wires) |
- |
1500 |
|
- |
| 16.0(Components) |
- |
0 |
|
- |
| 17 Table-1(Screws and connections) |
- |
1000 |
|
- |
| 18.0(Clearance and creepage distance) |
- |
2000 |
|
- |
| 19.1(Ball pressure test IEC 60695-10-2) |
- |
1000 |
|
- |
| 19.2.1(Glow wire test IEC 60695-2-11) |
- |
500 |
|
- |
| 19.2.2(Needle flame test) |
- |
1000 |
|
- |
| 20.0(Radiation, toxicity and similar hazards) |
- |
0 |
|
- |
|
Complete
|
|
- |
- - |
| 12 |
IS 10322 : Part 5 : Sec 9 (2017) |
Luminaires: Part 5 particular requirements: Sec 9 rope lights |
- |
-
|
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 21.4(General Test Requireements) |
- |
0 |
|
- |
| 21.5(Classification of Luminaires') |
- |
1500 |
|
- |
| 21.6(Marking) |
- |
500 |
|
- |
| 21.7(Construction) |
- |
15000 |
|
- |
| 21.8(Creepage Distance and Clearances) |
- |
1000 |
|
- |
| 21.9(Provision for earthing) |
- |
2000 |
|
- |
| 21.10(Terminals) |
- |
1000 |
|
- |
| 21.11(External & Internal Wiring) |
- |
1000 |
|
- |
| 21.12(Protection against electric shock) |
- |
1000 |
|
- |
| 21.13(Endurance Tests and Thermal Tests) |
- |
1000 |
|
- |
| 21.14(Resistance to Dust & Moisture) |
- |
1000 |
|
- |
| 21.15(Insulation Resistance and Electric Strength) |
- |
1500 |
|
- |
| 21.16(Resistance to Heat , fire and tracking) |
- |
3000 |
|
- |
|
Complete
|
|
- |
- - |
| 13 |
IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
- |
-
|
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
0 |
|
- |
| 7.0(Marking and instructions) |
- |
1000 |
|
- |
| 8.0(Protection against access to live part test) |
- |
3000 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
2000 |
|
- |
| 10.0(Power Input and current test) |
- |
1500 |
|
- |
| 11.0(Heating test) |
- |
1500 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
1000 |
|
- |
| 14.0(Transient voltages) |
- |
1000 |
|
- |
| 15.0(Moisture Resistance) |
- |
1500 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
1500 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
1000 |
|
- |
| 18.0(Endurance test) |
- |
1000 |
|
- |
| 19.0(Abnormal Operations) |
- |
1000 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
2500 |
|
- |
| 21.0(Mechanical Strength) |
- |
3000 |
|
- |
| 22.0(Construction verification related tests) |
- |
4500 |
|
- |
| 23.0(Internal wiring) |
- |
2500 |
|
- |
| 24.0(Components) |
- |
0 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
2000 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
2500 |
|
- |
| 27.0(Provision for Earthing) |
- |
2500 |
|
- |
| 28.0(Screws and connections) |
- |
2500 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
2000 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
2000 |
|
- |
| 31.0(Resistance to rusting) |
- |
2000 |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
0 |
|
- |
|
Complete
|
|
- |
- - |
| 14 |
IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
-
|
16257 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
257 |
|
- |
| 8(Protection against live parts) |
- |
1000 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
500 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
1000 |
|
- |
| 11(HEATING) |
- |
1000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1000 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
500 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
500 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1000 |
|
- |
| 18(ENDURANCE) |
- |
1000 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
500 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
500 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
500 |
|
- |
| 22(CONSTRUCTION) |
- |
500 |
|
- |
| 23(INTERNAL WIRING) |
- |
700 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
500 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
500 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
500 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
500 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
500 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
0 |
|
- |
|
Complete
|
|
- |
- - |
| 15 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
-
|
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.5(Components) |
- |
0 |
|
- |
| 1.6(Power interface .) |
- |
2500 |
|
- |
| 1.7(Markings and instructions) |
- |
500 |
|
- |
| 2.1(Protection from electric shock and energy hazards) |
- |
2500 |
|
- |
| 2.2(SELV circuits) |
- |
1500 |
|
- |
| 2.3(TNV circuits) |
- |
1000 |
|
- |
| 2.4(Limited current circuits) |
- |
1500 |
|
- |
| 2.5(Limited power sources .) |
- |
1900 |
|
- |
| 2.6(Provisions for earthing and bonding) |
- |
1000 |
|
- |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
1000 |
|
- |
| 2.8(Safety interlocks) |
- |
500 |
|
- |
| 2.9(Electrical insulation) |
- |
1000 |
|
- |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
1000 |
|
- |
| 3.1(General) |
- |
1000 |
|
- |
| 3.2(Connection to a mains supply) |
- |
500 |
|
- |
| 3.3(Wiring terminals for connection of external conductors) |
- |
500 |
|
- |
| 3.4(Disconnection from the mains supply) |
- |
500 |
|
- |
| 4.1(Stability) |
- |
500 |
|
- |
| 4.2(Mechanical strength) |
- |
1000 |
|
- |
| 4.3(Design and construction) |
- |
500 |
|
- |
| 4.4(Protection against hazardous moving parts) |
- |
1000 |
|
- |
| 4.5(Thermal requirements) |
- |
500 |
|
- |
| 4.6(Openings in enclosures) |
- |
1000 |
|
- |
| 4.7(Resistance to fire) |
- |
3000 |
|
- |
| 5.1(Touch current and protective conductor curren) |
- |
100 |
|
- |
| 5.2(Electric strength) |
- |
3000 |
|
- |
| 5.3(Abnormal operating and fault conditions) |
- |
3000 |
|
- |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
3000 |
|
- |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
3000 |
|
- |
| 7.1(General) |
- |
0 |
|
- |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
3000 |
|
- |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
2000 |
|
- |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
2000 |
|
- |
|
Complete
|
|
- |
- - |
| 16 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
-
|
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
1500 |
|
- |
| 8(Protection against accidental contact with live parts) |
- |
1500 |
|
- |
| 9(Terminals) |
- |
3500 |
|
- |
| 10(PROVISION FOR EARTHING) |
- |
3500 |
|
- |
| 11(MOISTURE RESISTANCE) |
- |
4000 |
|
- |
| 12(Electric Strength) |
- |
3000 |
|
- |
| 13(Thermal endurance test for winding of ballasts) |
- |
3500 |
|
- |
| 14(Fault conditions) |
- |
3000 |
|
- |
| 15(Transformer heating) |
- |
5000 |
|
- |
| 16(Construction) |
- |
3000 |
|
- |
| 17(Creepage distance and clearances) |
- |
3500 |
|
- |
| 18(Screws, current carrying parts and connections) |
- |
4000 |
|
- |
| 19(Resistance to heat, fire and tracking) |
- |
3000 |
|
- |
| 20(Resistance to corrosion) |
- |
3000 |
|
- |
|
Complete
|
|
- |
- - |
| 17 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
-
|
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
500 |
|
- |
| 6(Interchangeability) |
- |
10000 |
|
- |
| 7(Protection against accidental contact with live parts) |
- |
4500 |
|
- |
| 9(MECHANICAL STRENGTH) |
- |
10000 |
|
- |
| 10(cap temperature) |
- |
5000 |
|
- |
| 11(Resistance to Heat) |
- |
5000 |
|
- |
| 12(Resistance to Flame and Ignition) |
- |
5000 |
|
- |
| 13(Fault conditions) |
- |
5000 |
|
- |
| 14(Creepage distance and clearances) |
- |
5000 |
|
- |
|
Complete
|
|
- |
- - |
| 18 |
IS 302 : Part 2 : Sec 25 (2014) |
Safety of household and similar electrical appliances: Part 2 Particular requirements: Section 25 Microwave ovens |
- |
-
|
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
600 |
|
- |
| 8(Protection against live parts) |
- |
700 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
1000 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
1000 |
|
- |
| 11(HEATING) |
- |
2000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1000 |
|
- |
| 14(IMPULSE VOLTAGE TEST) |
- |
2000 |
|
- |
| 15(HUMIDITY TREATMENT TEST) |
- |
3000 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1000 |
|
- |
| 18(ENDURANCE) |
- |
5000 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
3500 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
700 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
| 22(CONSTRUCTION) |
- |
750 |
|
- |
| 23(INTERNAL WIRING) |
- |
750 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1500 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1500 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
1500 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
1500 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
2500 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
1500 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
1500 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
3000 |
|
- |
|
Complete
|
|
- |
- - |
| 19 |
IS 302 : Part 2 : Sec 26 (2014) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 26 clocks (First Revision) |
- |
-
|
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
| 8(Protection against live parts) |
- |
750 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
2000 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
1500 |
|
- |
| 11(HEATING) |
- |
2000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1500 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
3000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
3500 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1000 |
|
- |
| 18(ENDURANCE) |
- |
1000 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
1500 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
750 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
| 22(CONSTRUCTION) |
- |
750 |
|
- |
| 23(INTERNAL WIRING) |
- |
750 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
750 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
750 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
1500 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
1500 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- - |
| 20 |
IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- |
-
|
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking and instructions) |
- |
1000 |
|
- |
| 6(Hazardous radiations) |
- |
3000 |
|
- |
| 7(Heating under normal operating conditions) |
- |
3000 |
|
- |
| 8(Constructional requirements with regard to the protection against electric shock) |
- |
3000 |
|
- |
| 9(Electric shock hazard under normal operating conditions) |
- |
3000 |
|
- |
| 10(Insulation requirements) |
- |
2000 |
|
- |
| 11(Fault conditions) |
- |
3000 |
|
- |
| 12(Mechanical strength) |
- |
5000 |
|
- |
| 13(CLEARANCES and CREEPAGE DISTANCES) |
- |
5000 |
|
- |
| 15(TERMINALS) |
- |
2000 |
|
- |
| 16(External flexible cords) |
- |
2000 |
|
- |
| 17(Electrical connections and mechanical fixings) |
- |
2000 |
|
- |
| 18(Mechanical strength of picture tubes and protection against the effects of implosion) |
- |
500 |
|
- |
| 19(Stability and mechanical hazards) |
- |
2500 |
|
- |
| 20(Resistance to fire) |
- |
3000 |
|
- |
|
Complete
|
|
- |
- - |
| 21 |
IS 3976 (2018) |
Safety Rubber Canvas Boots for Miners †Specification ( Sixth Revision ) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
- |
- - |
| 22 |
IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
- |
-
|
80000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
10000 |
|
- |
| 5(General Safety Considerations) |
- |
0 |
|
- |
| 5.1(General) |
- |
0 |
|
- |
| 5.2(Insulation and Wiring) |
- |
5000 |
|
- |
| 5.3(Venting) |
- |
3000 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
2000 |
|
- |
| 5.5(Terminal Contacts) |
- |
0 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
0 |
|
- |
| 5.7(Quality Plan) |
- |
0 |
|
- |
| 6(Tyoe Test amd Sample Size) |
- |
0 |
|
- |
| 7(Specific requirements and tests) |
- |
0 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
0 |
|
- |
| 7.2(Intended Use) |
- |
27000 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
30000 |
|
- |
| 8(Information for safety) |
- |
0 |
|
- |
| 8.1(General) |
- |
0 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
0 |
|
- |
| 9(Marking) |
- |
0 |
|
- |
| 9.1(Cell Marking) |
- |
1500 |
|
- |
| 9.2(Battery Marking) |
- |
1500 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
0 |
|
- |
| 9.4(Other information) |
- |
0 |
|
- |
| 10(Packaging) |
- |
0 |
|
- |
|
Complete
|
|
- |
- - |
| 23 |
IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
- |
-
|
80000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
10000 |
|
- |
| 5(General Safety Considerations) |
- |
0 |
|
- |
| 5.1(General) |
- |
0 |
|
- |
| 5.2(Insulation and Wiring) |
- |
10000 |
|
- |
| 5.3(Venting) |
- |
5000 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
10000 |
|
- |
| 5.5(Terminal Contacts) |
- |
5000 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
5000 |
|
- |
| 5.7(Quality Plan) |
- |
0 |
|
- |
| 5.8(Battery Safety Components) |
- |
0 |
|
- |
| 6(Tyoe Test amd Sample Size) |
- |
10000 |
|
- |
| 7(Specific requirements and tests) |
- |
6500 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
0 |
|
- |
| 7.2(Intended Use) |
- |
10000 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
0 |
|
- |
| 8(Information for safety) |
- |
0 |
|
- |
| 8.1(General) |
- |
0 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
0 |
|
- |
| 9(Marking) |
- |
2000 |
|
- |
| 9.1(Cell Marking) |
- |
2000 |
|
- |
| 9.2(Battery Marking) |
- |
2000 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
0 |
|
- |
| 9.4(Other information) |
- |
0 |
|
- |
| 10(Packaging) |
- |
2500 |
|
- |
|
Complete
|
|
- |
- - |
| 24 |
IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
- |
-
|
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 20.4(General Test Requireements) |
- |
0 |
|
10% Discount for BIS |
| 20.5(Classification of Luminaires') |
- |
0 |
|
- |
| 20.6(Marking) |
- |
500 |
|
- |
| 20.7(Construction) |
- |
8000 |
|
- |
| 20.8(Creepage Distance and Clearances) |
- |
2500 |
|
- |
| 20.9(Provision for earthing) |
- |
1000 |
|
- |
| 20.10(Terminals) |
- |
2500 |
|
- |
| 20.11(External & Internal Wiring) |
- |
10000 |
|
- |
| 20.12(Protection against electric shock) |
- |
1000 |
|
- |
| 20.13(Endurance Tests and Thermal Tests) |
- |
2500 |
|
- |
| 20.14(Resistance to Dust & Moisture) |
- |
7500 |
|
- |
| 20.15(Insulation Resistance and Electric Strength) |
- |
1000 |
|
- |
| 20.16(Resistance to Heat , fire and tracking) |
- |
2500 |
|
- |
|
Complete
|
|
- |
- - |
| 25 |
IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
- |
-
|
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
0 |
|
10% Discount for BIS |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
| 6.0(Marking) |
- |
1500 |
|
- |
| 7.0(Construction) |
- |
8000 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
4500 |
|
- |
| 9.0(Provision for earthing) |
- |
4000 |
|
- |
| 10.0(Terminals) |
- |
2500 |
|
- |
| 11.0(External & Internal Wiring) |
- |
3000 |
|
- |
| 12.0(Protection against electric shock) |
- |
4000 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
2500 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
7500 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
8000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
4500 |
|
- |
| 17.0(Photometric Test) |
- |
0 |
|
- |
|
Complete
|
|
- |
- - |
| 26 |
IS 3521 (1999) |
Industrial safety belts and harnesses - Specification (Third Revision) |
- |
-
|
17700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4(Classification) |
- |
100 |
|
- |
| Cl 5(Design and Construction) |
- |
100 |
|
- |
| Cl 5.1(Width and Strength of the Straps) |
- |
1000 |
|
- |
| Cl 5.2.1(Webbing) |
- |
8500 |
|
- |
| Cl 5.2.2(Threads for Sewing) |
- |
200 |
|
- |
| Cl 5.2.3(Rivets and Washers) |
- |
200 |
|
- |
| Cl 5.2.4(Life Line/ Safety Line) |
- |
200 |
|
- |
| Cl 5.2.4.1(Working At Height) |
- |
200 |
|
- |
| Cl 5.2.5(Metal Components) |
- |
200 |
|
- |
| Cl 5.3.1( Strength) |
- |
1500 |
|
- |
| Cl 5.3.2(Attachment Means) |
- |
1500 |
|
- |
| Cl 5.3.3(Static Load) |
- |
1500 |
|
- |
| Cl 5.3.4(Dynamic Load) |
- |
2500 |
|
- |
|
Complete
|
|
- |
- - |
| 27 |
IS 15298 : part 4 (2017) |
Personal protective equipment: Part 4 occupational footwear (Second Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
- |
- - |
| 28 |
IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
- |
-
|
1730 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Marking) |
- |
180 |
|
- |
| 6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
- |
| 6.3(Standard Mark on Conduit) |
- |
0 |
|
- |
| 7.1.1(Maximum and minimum outside diameter of socket) |
- |
50 |
|
- |
| 7.1.1 Table-2(Length of Socket end) |
- |
0 |
|
- |
| 7.1.2(Maximum and minimum outside diameter of conduit) |
- |
0 |
|
- |
| 7.2(Minimum inside diameter of conduit) |
- |
0 |
|
- |
| 7.3(Length of conduit) |
- |
0 |
|
- |
| 7.4(Unifomity of The wall Thickness) |
- |
0 |
|
- |
| 8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
150 |
|
- |
| 9.2(Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
300 |
|
- |
| 9.3(Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
- |
| 9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
- |
| 9.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
- |
| 10(Resistance to Heat -Ball presure test) |
- |
300 |
|
- |
| 11(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
- |
| 12(Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
- |
| 12(Electrical Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
- |
| 13(Tests for external influence as per clause 13 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
- |
| 13(Tests for external influence as per clause 13 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
- |
| 12(3 Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
- |
| 12(3 Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
- |
| 11.0(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
- |
| 10.0(Resistance to Heat -Ball presure test) |
- |
0 |
|
- |
| 9.5 Fig.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
- |
| 9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
- |
| 9.3(Compression Test (after removal of force) as per caluse 9.3.3 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
- |
| 9.3(Compression Test at Full force applied (On load)) |
- |
0 |
|
- |
| 9.2(Bending Test At Low Temp (-5 ±2°C)) |
- |
0 |
|
- |
| 9.2(Bending Test At Room Temp ) |
- |
0 |
|
- |
| 8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
150 |
|
- |
| 7.4(Unifomity of The wall Thickness ) |
- |
0 |
|
- |
| 7.3(Length of conduit) |
- |
0 |
|
- |
| 7.2 Fig.3(Minimum inside diameter of conduit) |
- |
0 |
|
- |
| 7.1.2 Fig.2(Minimum outside diameter of conduit) |
- |
0 |
|
- |
| 7.1.2 Fig.1(Maximum outside diameter of conduit) |
- |
0 |
|
- |
| 7.1.1 Table-2(Length of Socket end) |
- |
0 |
|
- |
| 7.1.1 Fig.8(Maximum inside diameter of socket) |
- |
0 |
|
- |
| 7.1.1 Fig.7(Maximum outside diameter of socket) |
- |
0 |
|
- |
| 6.3(Standard Mark on Conduit) |
- |
0 |
|
- |
| 6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
- |
| 6.1 - d(Marking) |
- |
0 |
|
- |
| 6.1 - c(Marking) |
- |
0 |
|
- |
| 6.1 - b(Marking) |
- |
0 |
|
- |
| 6.1 - a(Marking) |
- |
0 |
|
- |
|
Complete
|
|
- |
- - |
| 29 |
IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
- |
-
|
12500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 13(Cable code) |
- |
200 |
|
- |
| 11.2(Legibility) |
- |
100 |
|
- |
| 11.1(Durability) |
- |
200 |
|
- |
| 11(Identification) |
- |
300 |
|
- |
| 10.9(Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
500 |
|
- |
| 10.4(Flammability test- Unaffected portion) |
- |
400 |
|
- |
| 10.4(Flammability test-Burning after flame removal) |
- |
400 |
|
- |
| table 1 e) 3) (IR constant- max. Temp) |
- |
200 |
|
- |
| table 1 e) 3) (IR constant- Room temp ) |
- |
200 |
|
- |
| table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
200 |
|
- |
| table 1 e) 3) (Volume Resistivity - Room temp ) |
- |
0 |
|
- |
| 10.2(HV (room temperature)) |
- |
250 |
|
- |
| 10.1(HV (water immersion)) |
- |
250 |
|
- |
| 10.8(Smoke density rating) |
- |
250 |
|
- |
| 10.6(Halogen evolution) |
- |
300 |
|
- |
| 10.7(Temperature index) |
- |
300 |
|
- |
| 10.5(Oxygen index) |
- |
300 |
|
- |
| Table 1 iii) d) 9)(Cold impact for sheath) |
- |
300 |
|
- |
| Table 1 iii) d) 8)(Cold bend for sheath) |
- |
200 |
|
- |
| Table 1 iii) c) 9)(Cold impact for insulation) |
- |
300 |
|
- |
| Table 1(Category Code) |
- |
0 |
|
- |
| Table 1 iii) d) 7)(Thermal stability- Sheath ) |
- |
300 |
|
- |
| Table 1 iii) c) 7)(Thermal stability- Insulation ) |
- |
300 |
|
- |
| Table 1 iii) d) 6)(Hot deformation -Indentation depth - Sheath ) |
- |
250 |
|
- |
| Table 1 iii) c) 6)(Hot deformation - Indentation depth- Insulation) |
- |
200 |
|
- |
| Table 1 iii) d) 5)(Heat shock-Sheath ) |
- |
200 |
|
- |
| Table 1 iii) c) 5)(Heat shock-Insulation ) |
- |
200 |
|
- |
| Table 1 iii) d) 4)(Cracks Observed) |
- |
0 |
|
- |
| Table 1 iii) d) 4)(Shrinkage- Sheath ) |
- |
200 |
|
- |
| Table 1 iii) c) 4)(Shrinkage-Insulation) |
- |
200 |
|
- |
| Table 1 iii) d) 2)(Loss of mass- Sheath ) |
- |
200 |
|
- |
| Table 1 iii) c) 2)(Loss of mass- Insulation ) |
- |
200 |
|
- |
| Table 1 iii) d) 3)(Sheath- Elongation variation) |
- |
200 |
|
- |
| Table 1 iii) d) 3)(Sheath- TS variation) |
- |
200 |
|
- |
| Table 1 iii) c) 3)(Elongation (After ageing)) |
- |
200 |
|
- |
| Table 1 iii) c) 3)(Tensile strength (After ageing)) |
- |
200 |
|
- |
| Table 1 iii) c) 1)(Elongation (Without ageing)) |
- |
0 |
|
- |
| Table 1 iii) c) 1)(Tensile strength (Without ageing)) |
- |
0 |
|
- |
| (Cl. 18.1.4)
(Cl. 19.1.5)
(Cl. 20.1.4)
(Cl. 22.1.4)(Colour of Sheath) |
- |
0 |
|
- |
| 8.3(Thickness of Sheath) |
- |
200 |
|
- |
| 5.2(Application ) |
- |
0 |
|
- |
| 5.3(Thickness of Insulation) |
- |
200 |
|
- |
| 9.1(Ovality) |
- |
100 |
|
- |
| 9(Overall dimensions) |
- |
100 |
|
- |
| 10.11(Per sulphate test (for tinned Cu cable only)) |
- |
300 |
|
- |
| 4.2(Conductor resistance test) |
- |
300 |
|
- |
| 4.1(Wrapping test (for Al)) |
- |
200 |
|
- |
| 4.1(Tensile test (for Al)- After Stranding) |
- |
100 |
|
- |
| 4.1(Tensile test (for Al)-Before Stranding) |
- |
200 |
|
- |
| 4.1(Annealing test (for copper)) |
- |
200 |
|
- |
| (Cl.6.1.3 of IS 8130:2013)(Flexible Conductors (Classes 5)) |
- |
100 |
|
- |
| (Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors(Class-2)) |
- |
100 |
|
- |
| (Cl.6.1.3 of IS 8130:2013)(Stranded compacted circular conductors and shaped conductors (Class 2)) |
- |
100 |
|
- |
| (Cl.6.1.3 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
100 |
|
- |
| (Cl.16.1)
(Cl.19.1)(Conductor- Diameter ) |
- |
100 |
|
- |
| (Cl.16.1)
(Cl.19.1)(Conductor) |
- |
100 |
|
- |
| 4.1(Conductor - Material) |
- |
100 |
|
- |
| 12.0(Core identification) |
- |
100 |
|
- |
| 7(Binder Tape) |
- |
400 |
|
- |
| 6.2(Filler) |
- |
300 |
|
- |
| 5.1(Insulation) |
- |
100 |
|
- |
| 4.4(Joints in Conductor) |
- |
100 |
|
- |
| 4, IS 8130(Construction of conductor) |
- |
100 |
|
- |
| Table 2, IS 8130(No fo wire in a conductor) |
- |
100 |
|
- |
| 8.3(Minimum thickness of Sheath) |
- |
100 |
|
- |
| 8.3(Avarage thickness of Sheath) |
- |
100 |
|
- |
| 5.3(Minimum thickness of insulation) |
- |
100 |
|
- |
| 5.3(Avarage thickness of insulation) |
- |
100 |
|
- |
|
Complete
|
|
- |
- - |
| 30 |
IS 3854 (1997) |
Switches for domestic and similar purposes - Specification (Second Revision) |
- |
-
|
9000 View breakup
Rs.7000 Up to 16 A;
Rs.7500/- for 20 A;
Rs.9000/- for 32 A.
[10% discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8(Marking) |
- |
200 |
|
10% Discount for BIS |
| 8.9(Marking) |
- |
200 |
|
10% Discount for BIS |
| 6(Rating) |
- |
200 |
|
10% Discount for BIS |
| 7(Classification) |
- |
200 |
|
10% Discount for BIS |
| 10(Protection against Electric Shock) |
- |
400 |
|
10% Discount for BIS |
| 11.1(Provision for earthing) |
- |
400 |
|
10% Discount for BIS |
| 12(Terminals) |
- |
200 |
|
10% Discount for BIS |
| 13.1(a) Insulating lining, barriers and the like [Cl 13.1]) |
- |
100 |
|
10% Discount for BIS |
| 13.2(b) Construction of switch [Cl 13.2]) |
- |
100 |
|
10% Discount for BIS |
| 13.2(i) Installation Test) |
- |
100 |
|
10% Discount for BIS |
| 13.3(c) Covers,cover plates and actuating members [Cl 13.3]) |
- |
100 |
|
10% Discount for BIS |
| 13.4(d) Ordinary switches [Cl 13.4]) |
- |
100 |
|
10% Discount for BIS |
| 13.5(e) Rotary switches [Cl 13.5]) |
- |
100 |
|
10% Discount for BIS |
| 13.6(f) Screws and other means [Cl 13.6]) |
- |
100 |
|
10% Discount for BIS |
| 13.7(g) Combination of switches or switches and socket outlets [Cl 13.7]) |
- |
100 |
|
10% Discount for BIS |
| 13.8(h) Assessories combined with switches [Cl. 13.8]) |
- |
100 |
|
10% Discount for BIS |
| 13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
100 |
|
10% Discount for BIS |
| 13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
100 |
|
10% Discount for BIS |
| 13.1(k) Switches to be installed in a box [Cl. 13.10]) |
- |
100 |
|
10% Discount for BIS |
| 13.11(l) Surface type switches other than ordinary switch [Cl. 13.11]) |
- |
100 |
|
10% Discount for BIS |
| 13.12, 13.13, 13.14(m) Inlet opening [Cl. 13.12.13.13 & 13.14]) |
- |
100 |
|
10% Discount for BIS |
| 13.15(q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
100 |
|
10% Discount for BIS |
| 14(Mechanism [Cl. 14]) |
- |
200 |
|
10% Discount for BIS |
| 15.1(Resistance to Ageing, to Harmful Ingress of water and to Humidity [Cl. 15]: Resistance to Ageing, [Cl. 15.1]) |
- |
200 |
|
10% Discount for BIS |
| 15.2(b)Resistance to Harmful ingress of water [Cl. 15.2]) |
- |
200 |
|
10% Discount for BIS |
| 15.3(c) Resistance to Humidity [Cl. 15.3]) |
- |
200 |
|
10% Discount for BIS |
| 16.1(Insulation resistance [Cl. 16.1]) |
- |
200 |
|
10% Discount for BIS |
| 16.2( Electric Strength [Cl. 16.2]) |
- |
200 |
|
10% Discount for BIS |
| 17(Temperature- rise [Cl. 17]) |
- |
500 |
|
10% Discount for BIS |
| 18(Marking and breaking Capacity[Cl. 18]) |
- |
400 |
|
10% Discount for BIS |
| 19(Normal Operation [Cl. 19] a) General & Operation) |
- |
100 |
|
10% Discount for BIS |
| 19(b) Electric Strength) |
- |
100 |
|
10% Discount for BIS |
| 19(c)Temperature-rise ) |
- |
100 |
|
10% Discount for BIS |
| 19.2(Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
100 |
|
10% Discount for BIS |
| 20(Mechanical Strength Test [Cl. 20]) |
- |
400 |
|
10% Discount for BIS |
| 21(Resistance to Heat [Cl.21]) |
- |
500 |
|
10% Discount for BIS |
| 22(Screw, Current Carrying Part And Connection [Cl.22]) |
- |
500 |
|
10% Discount for BIS |
| 23.2(Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
500 |
|
10% Discount for BIS |
| 24.1.1(Resistance to Abnormal Heat & Fire [Cl.24.1] [Glow Wire Test] [Cl.24.1.1]) |
- |
600 |
|
10% Discount for BIS |
| 24.2(Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
600 |
|
10% Discount for BIS |
|
Complete
|
|
- |
- 0.0 |