| 211 |
IS 1660 (2009) |
Wrought aluminium utensils - Specification (First Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1 (Classification Heavy/Medium/L:ight) |
- |
|
|
|
| 5.1 (The utensil shall be pressed or spun from one piece) |
- |
|
|
|
| 5.2 ( Body Thickness of the thinnest part of the finished utensil, mm Not declared ) |
- |
|
|
|
| 6.1 & Table 1 ( i) Name of Utensil ) |
- |
|
|
|
| 6.1 & Table 1 (ii) Shape of Utensil) |
- |
|
|
|
| 6.1 & Table 1 (Inside dia, Φ D mm Not declared ) |
- |
|
|
|
| 6.1 & Table 1 (Height NA) |
- |
|
|
|
| 6.1 & Table 1 (Capacity, l NA) |
- |
|
|
|
| 6.1 ( Minimum sheet thickness for nominal size ) |
- |
|
|
|
| 7.1 (HANDLES ,When fitted shall be of aluminium, stainless steel or of other suitable fire resistance material These shall be fastened to the utensils by tightly drawn aluminium or stainless steel rivets, by welding, by screwing to cast bosses or by riveting between flange at the end of the handles. Handles shall be so shaped and positioned to facilitate the carrying and handling of the utensils in normal use ) |
- |
|
|
|
| 7.2 (Handles shall be sufficiently strong to support a mass in the utensils equivalent to three times the mass of the water capacity of the utensils in the position of normal use without visible permanent deformation of the handle or utensil) |
- |
|
|
|
| 8.1 (The utensils shall be clean reasonably free from distortion, dents, wrinkles, wavy surface, burrs, scratches, pitting and deep tool marks and other surface defects) |
- |
|
|
|
| 8.2 (The design of the utensils shall be such that it is easy to clean and prevent accumulation of dirt) |
- |
|
|
|
| 8.4.1.2 ( Finish of the coating: The coating shall be smooth continuous and uniform in appearance, and shall be adherent. It shall be free from powdery areas, loose films and discontinuities, such as breaks and scratches. The size and number of contact marks shall be minimum consistent with good practice.) |
- |
|
|
|
| 8.4.2 (A coating of thickness 25 to 100 microns is generally required) |
- |
|
|
|
| 8.4.3 (Abrasion Resistance When the coating surface is rubbed two or three times with emery paper with emery conforming to grit number 180 using medium finger pressure, it shall not abrade the surface but shall skid over the surface showing not more than a trace of whitening of the surface) |
- |
|
|
|
| 8.4.4 (The colour of the hard anodic coating varies depending upon the alloy, thickness of the coating and electrolye. Normally the colour may vary from dark grey (almost black) to light grey. ) |
- |
|
|
|
| 8.4.5 (When the coated surface is rubbed two or three times with fine emery paper grit number 180 using medium finger pressure, cloth or paper shall not abrade the surface. A faint trace of whitening on the cloth or paper is permissible) |
- |
|
|
|
| 9 (The manufacturer shall provide full instructions for use and cleaning for coated or hard anodized utensils) |
- |
|
|
|
| 10 (Each vessel shall be legibly and indelibly stamped on the outside surface or handle with the manufacturer’s name or registered trade-mark, size and thickness or class. ) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 212 |
IS 6452 (1989) |
High alumina cement for structural use - specification (First Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2 (Fineness
IS 4031(Part 2)) |
- |
|
|
|
| 4.3 (Soundness, Le-Chate1ier expansion
IS 4031(Part 3) ) |
- |
|
|
|
| 4.4 (Setting Time ( by Vicat Apparatus ),Initial
IS 4031(Part 5)) |
- |
|
|
|
| 4.4 (Setting Time ( by Vicat Apparatus ), Final
IS 4031(Part 5)) |
- |
|
|
|
| 4.5 (Compretsive Strenqth .24 hrs ± 30min
IS 4031(Part 6)) |
- |
|
|
|
| 4.5 (Compretsive Strenqth .72 ± 1 hr
IS 4031(Part 6)) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 213 |
IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1 (MATERIALS : CONDUCTOR) |
- |
|
|
|
| 4.1.1 (INSULATION : General Purjose Insulaiion) |
- |
|
|
|
| 4.1.2 (INSULATION : Heat Resisting Insulation) |
- |
|
|
|
| 5.1 (MATERIALS : FILLER AND INNER SHEATH) |
- |
|
|
|
| 5.2 (MATERIALS : FILLER AND INNER SHEATH) |
- |
|
|
|
| 6.1 (MATERIALS : ARMGURING) |
- |
|
|
|
| 6.2 (MATERIALS : ARMGURING) |
- |
|
|
|
| 7.1.1 (OUTER SHEATH : For Cables with General Purpose InsuIafion) |
- |
|
|
|
| 7.1.2 (OUTER SHEATH : For Cables with Heat Resisting InsuIalion) |
- |
|
|
|
| 8.1 (CONSTRUCTION : CONDUCTOR) |
- |
|
|
|
| 8.2 (CONSTRUCTION : CONDUCTOR) |
- |
|
|
|
| 9.1 (INSULATION ) |
- |
|
|
|
| 9.2 (INSULATION : Thickness of Insulation) |
- |
|
|
|
| 9.3 (INSULATION :Tolerance on Thickness of Insulation) |
- |
|
|
|
| 9.4 (INSULATION : Application of Insulation) |
- |
|
|
|
| 10.1 (CORE IDENTIFICATION) |
- |
|
|
|
| 10.2 (CORE IDENTIFICATION) |
- |
|
|
|
| 10.3 (CORE IDENTIFICATION) |
- |
|
|
|
| 10.3.1 (Arrangement of Marking) |
- |
|
|
|
| 11.1 (LAYING UP OF CORES) |
- |
|
|
|
| 11.2 (LAYING UP OF CORES) |
- |
|
|
|
| 12.1 (INNER SHEATH) |
- |
|
|
|
| 12.2 (INNER SHEATH) |
- |
|
|
|
| 12.3 (INNER SHEATH :Thickness of Inner Sheath) |
- |
|
|
|
| 12.3.1 (INNER SHEATH :Thickness of Inner Sheath) |
- |
|
|
|
| 13.1.1 (ARMOURING : Application) |
- |
|
|
|
| 13.1.2 (Armouring: Coverage ) |
- |
|
|
|
| 13.1.3 (ARMOURING : Direction of lay ) |
- |
|
|
|
| 13.1.4 (ARMOURING : Application) |
- |
|
|
|
| 13.2 (ARMOURING : Type of Armour) |
- |
|
|
|
| 13.2.1 (ARMOURING : Type of Armour) |
- |
|
|
|
| 13.3 (Armouring : Dimensions -Wire Diameter) |
- |
|
|
|
| 13.3 (Armouring : Dimensions -Formed wire ) |
- |
|
|
|
| 13.4 (ARMOURING : Joints) |
- |
|
|
|
| 13.5.1 (ARMOURING : Resistance) |
- |
|
|
|
| 13.5.2 (ARMOURING : Resistance) |
- |
|
|
|
| 13.6 a) (ARMOURING: Tensile Strength) |
- |
|
|
|
| 13.6 b) (ARMOURING: Elongation ) |
- |
|
|
|
| 13.6 c) (ARMOURING: Torsion Test (For round wire ) ) |
- |
|
|
|
| 13.6 d) (ARMOURING: Winding Test(For formed wire)) |
- |
|
|
|
| 13.6 e) (ARMOURING: Uniformity of zinc coating) |
- |
|
|
|
| 13.6 f) (ARMOURING: Mass of zinc coating ) |
- |
|
|
|
| 13.6 g) (ARMOURING: Resistivity) |
- |
|
|
|
| 14.1 (OUTER SHEATH) |
- |
|
|
|
| 14.2 (OUTER SHEATH) |
- |
|
|
|
| 14.3 (OUTER SHEATH : Colour ) |
- |
|
|
|
| 14.4.1 (Thickness of Outer Sheath : Unarmowed Cables) |
- |
|
|
|
| 14.4.2 (Thickness of Outer Sheath : Armoured Cables) |
- |
|
|
|
| 15.1 a) 1) (Tests on conductor : Annealing test ( for copper )) |
- |
|
|
|
| 15.1 a) 2) (Tensile test (for aluminium) - Before stranding ) |
- |
|
|
|
| 15.1 a) 2) (Tensile test (for aluminium) - After stranding ) |
- |
|
|
|
| 15.1 a) 3) (Tests on conductor : Wrapping test ( for aluminium )) |
- |
|
|
|
| 15.1 a) 4) (Tests on conductor : Conductor resistance test) |
- |
|
|
|
| 15.1 a) 4) (Resistance test - Neutral conductor ) |
- |
|
|
|
| 15.1 d)1) (Phyaical tests for insulation : Tensile Test) |
- |
|
|
|
| 15.1 d)1) (Phyaical tests for insulation : Elongation ) |
- |
|
|
|
| 15.1 d)1) (Physical tests for sheath : Tensile stregth ) |
- |
|
|
|
| 15.1 d)1) (Physical tests for sheath : Elongation ) |
- |
|
|
|
| 15.1 d)2) (Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
|
|
|
| 15.1 d)2) (Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
|
|
|
| 15.1 d)2) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
|
|
|
| 15.1 d)2) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
|
|
|
| 15.1 d)2) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
|
|
|
| 15.1 d)2) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
|
|
|
| 15.1 d)2) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
|
|
|
| 15.1 d)2) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
|
|
|
| 15.1 d)3) (Phyaical tests for insulation : Shrinkage ) |
- |
|
|
|
| 15.1 d)3) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
|
|
|
| 15.1 d)3) (Phyaical tests for Sheath : Shrinkage ) |
- |
|
|
|
| 15.1 d)3) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
|
|
|
| 15.1 d)4) (Hot deformation : Insulation ) |
- |
|
|
|
| 15.1 d)4) (Hot deformation : Sheath ) |
- |
|
|
|
| 15.1 d)5) ( Loss of mass in air oven- Insulation ) |
- |
|
|
|
| 15.1 d)5) ( Loss of mass in air oven- sheath ) |
- |
|
|
|
| 15.1 d)6) (Heat shock test- Insulation ) |
- |
|
|
|
| 15.1 d)6) (Heat shock test- sheath ) |
- |
|
|
|
| 15.1 d)7) (Thermal stability- insulation ) |
- |
|
|
|
| 15.1 d)7) (Thermal stability- Sheath ) |
- |
|
|
|
| 15.1 e) (Insulation resistance test : Volume Resistivity ) |
- |
|
|
|
| 15.1 e) (Insulation resistance test : IR Constant ) |
- |
|
|
|
| 15.1 f) (High voltage test ( water immersion test )) |
- |
|
|
|
| 15.1 g) (High voltage test at room temperature) |
- |
|
|
|
| 16.1 (DETAILS OF TESTS : General) |
- |
|
|
|
| 16.2 (DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
|
|
|
| 16.3.1 (High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
|
|
|
| 16.3.2 (High Voltage Test ( Water Immersion Test ) : d.c. Test) |
- |
|
|
|
| 16.4 (Flammability Test) |
- |
|
|
|
| 17.1 (IDENTIFICATION : Manufacturer’s Identification) |
- |
|
|
|
| 17.2 (IDENTIFICATION : Cable Identification) |
- |
|
|
|
| 17.2.1 (IDENTIFICATION : Cable Identification) |
- |
|
|
|
| 17.3 (IDENTIFICATION : Cable Code) |
- |
|
|
|
| 16.4 (Flammability Test) |
- |
|
|
|
| 13.6 f) (ARMOURING: Mass of zinc coating ) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 214 |
IS 11536 (2007) |
Processed - Cereal based complementary foods - Specification (Second Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 (Description) |
- |
|
|
|
| 5.7 (Flavour and odour) |
- |
|
|
|
| 5.9 Table 1 i (Moisture) |
- |
|
|
|
| 5.9 Table 1 ii (Total protein) |
- |
|
|
|
| 5.9 Table 1 iii (Total Carbohydrates) |
- |
|
|
|
| 5.9 Table 1 iv (Total Ash) |
- |
|
|
|
| 5.9 Table 1 v (Ash Insoluble in dilute Hydrochloric Acid) |
- |
|
|
|
| 5.9 (Ash Insoluble in dilute HCl Acid) |
- |
|
|
|
| 5.9 Table 1 vi (Iron) |
- |
|
|
|
| 5.9 (Zinc ) |
- |
|
|
|
| 5.9 (Lead) |
- |
|
|
|
| 5.9 (Copper) |
- |
|
|
|
| 5.9 (Arsenic) |
- |
|
|
|
| 5.9 (Tin) |
- |
|
|
|
| 5.9 (Cadmium) |
- |
|
|
|
| 5.8.1 ( Bacterial Count) |
- |
|
|
|
| 5.8.2 (Coliform Count) |
- |
|
|
|
| 5.8.3 (Yeast and Mould count) |
- |
|
|
|
| 5.8.4 (Salmonella) |
- |
|
|
|
| 5.8.4 (Shigella) |
- |
|
|
|
| 5.8.5 (Eseherichia coii) |
- |
|
|
|
| 5.8.6 (Staphylococcus aureus) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 215 |
IS 10325 (2000) |
Square tins - 15 kg/litre for ghee, vanaspati, edible oils and bakery shortenings - Specification (Second Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Dimensions and Tolerances) |
- |
|
|
|
| 4.2.2 (Handle) |
- |
|
|
|
| 5.1 (Air-Pressure Test) |
- |
|
|
|
| 5.3 (Hydraulic Pressure Test) |
- |
|
|
|
| 5.2 (Handle Pull Test) |
- |
|
|
|
| 4.1 (Dimensions and Tolerances) |
- |
|
|
|
| 4.3.1 (Manufacture) |
- |
|
|
|
| 4.3.2 (Manufacture) |
- |
|
|
|
| 4.3.4 (Manufacture) |
- |
|
|
|
| 4.3.5 (Handle) |
- |
|
|
|
| 4.3.5 (Handle) |
- |
|
|
|
| 4.3.5 (Handle) |
- |
|
|
|
| 4.3.5 (Handle) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 216 |
IS 1061 (2017) |
Disinfectant fluids, phenolic type - Specification (Fifth Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1 (Composition and Description) |
- |
|
|
|
| 4.4 (Mercury Compounds) |
- |
|
|
|
| 4.2 (Stability after Dilution) |
- |
|
|
|
| 4.3/3.2 (Germicidal Value) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 217 |
IS 15962 (2012) |
Structural steels for buildings and structures with improved seismic resistance |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 6 (Freedom from Defects) |
- |
|
|
|
| Cl 10 (Tensile Test) |
- |
|
|
|
| Cl 11 (Impact Test) |
- |
|
|
|
| Cl 13 (Dimensions) |
- |
|
|
|
| Cl 13 (Dimensions) |
- |
|
|
|
| Cl 13 (Dimensions) |
- |
|
|
|
| Cl 13 (Dimensions) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 218 |
IS 1029 (1970) |
Specification for hot-rolled steel strip (Baling) (First Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1 (Freedom from defects) |
- |
|
|
|
| 8.2 (Width) |
- |
|
|
|
| 8.2 (Thickness) |
- |
|
|
|
| 9.1 (Finishing & Packing) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 219 |
IS 1079 (2017) |
Hot rolled carbon steel sheet, plate and strip - Specification (Seventh Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8 (UTM) |
- |
|
|
|
| Cl 12 (Workmanship) |
- |
|
|
|
| Cl 13 (Length, Width & Thickness) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 220 |
IS 1011 (2002) |
Biscuits - Specification (Fourth Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 (General Requirement) |
- |
|
|
|
| 6.3 Table 2 i (Moisture) |
- |
|
|
|
| 6.3 Table 2 ii (Acid insoluble ash (on dry basis)) |
- |
|
|
|
| 6.3 Table 2 i (Moisture) |
- |
|
|
|
| 6.3 Table 2 ii (Acid insoluble ash (on dry basis)) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 221 |
IS 1417 (2016) |
Gold and gold alloys, jewellery/ artefacts - Fineness and marking - Specification (Fourth Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Fineness/ Gold Content in parts per thousand, percent) |
- |
|
|
|
| 4.1.1 (a) (Presence of Iridium) |
- |
|
|
|
| 4.1.1 (a) (Presence of Ruthenium) |
- |
|
|
|
| 4.1.1 (a) (Presence of Cadmium) |
- |
|
|
|
| 4.1.1 (a) (Presence of Osmium) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 222 |
IS 17423 (2020) |
Medical textiles – Coveralls for COVID 19 – Specification |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Manufacture - IS 17423) |
- |
|
|
|
| 4.1.1 (Manufacture - IS 17423) |
- |
|
|
|
| 4.1.1 (Manufacture - IS 17423) |
- |
|
|
|
| 4.2 (Manufacture - IS 17423) |
- |
|
|
|
| 4.2 (Manufacture - IS 17423) |
- |
|
|
|
| 4.3 (Manufacture - IS 17423) |
- |
|
|
|
| 4.3 (Manufacture - IS 17423) |
- |
|
|
|
| 4.4 (Manufacture - IS 17423) |
- |
|
|
|
| 4.4 (Manufacture - IS 17423) |
- |
|
|
|
| 4.5 (Manufacture - IS 17423) |
- |
|
|
|
| 4.6 (Manufacture - IS 17423) |
- |
|
|
|
| 5.1 (Workmanship and Finish - IS 17423) |
- |
|
|
|
| 5.1 (Workmanship and Finish - IS 17423) |
- |
|
|
|
| Table 1 & Cl.4.4, 5.2 and 5.3) (Blood Resistance Characteristics (Proceduce-C, table 1 IS 16546:2016) Coverall Fabric from body Specimen 1) |
- |
|
|
|
| Table 1 & Cl.4.4, 5.2 and 5.3) (Blood Resistance Characteristics (Proceduce-C, table 1 IS 16546:2016) Coverall Fabric from body Specimen 2) |
- |
|
|
|
| Table 1 & Cl.4.4, 5.2 and 5.3) (Blood Resistance Characteristics (Proceduce-C, table 1 IS 16546:2016) Coverall Fabric from body Specimen 3) |
- |
|
|
|
| Table 1 & Cl.4.4, 5.2 and 5.3) (Blood Resistance Characteristics (Proceduce-C, table 1 IS 16546:2016) Coverall Fabric at Seam Specimen 1) |
- |
|
|
|
| Table 1 & Cl.4.4, 5.2 and 5.3) (Blood Resistance Characteristics (Proceduce-C, table 1 IS 16546:2016) Coverall Fabric at Seam Specimen 2) |
- |
|
|
|
| Table 1 & Cl.4.4, 5.2 and 5.3) (Blood Resistance Characteristics (Proceduce-C, table 1 IS 16546:2016) Coverall Fabric at Seam Specimen 3) |
- |
|
|
|
| Table 1 & Cl.4.4, 5.2 and 5.3) (Blood Resistance Characteristics (Proceduce-C, table 1 IS 16546:2016) Shoe Cover Fabric from body Specimen 1) |
- |
|
|
|
| Table 1 & Cl.4.4, 5.2 and 5.3) (Blood Resistance Characteristics (Proceduce-C, table 1 IS 16546:2016) Shoe Cover Fabric from body Specimen 2) |
- |
|
|
|
| Table 1 & Cl.4.4, 5.2 and 5.3) (Blood Resistance Characteristics (Proceduce-C, table 1 IS 16546:2016) Shoe Cover Fabric from body Specimen 3) |
- |
|
|
|
| Table 1 & Cl.4.4, 5.2 and 5.3) (Blood Resistance Characteristics (Proceduce-C, table 1 IS 16546:2016) Shoe Cover of Seam Specimen 1) |
- |
|
|
|
| Table 1 & Cl.4.4, 5.2 and 5.3) (Blood Resistance Characteristics (Proceduce-C, table 1 IS 16546:2016) Shoe Cover of Seam Specimen 2) |
- |
|
|
|
| Table 1 & Cl.4.4, 5.2 and 5.3) (Blood Resistance Characteristics (Proceduce-C, table 1 IS 16546:2016) Shoe Cover of Seam Specimen 3) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 223 |
IS 15354 : Part 1 (2018) |
Single - Use medical examination gloves: Part 1 specification for gloves made from rubber latex or rubber solution (First Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 & Table 2 (Size code) |
- |
|
|
|
| 6.1 & Table 2 (Width corresponding to size code (dimension w,Figure 1)) |
- |
|
|
|
| 6.1 & Table 2 (Descriptive size) |
- |
|
|
|
| 6.1 & Table 2 (Width corresponding to Descriptive size (dimension w,Figure 1)) |
- |
|
|
|
| 6.1 & Table 2 (Minimum length (dimension l,
Figure 1)) |
- |
|
|
|
| 6.1 & Table 2 (Minimum thickness (at locations
shown in Figure 2)) |
- |
|
|
|
| 6.1 & Table 2 (Maximum thickness
(at approximate
centre of palm)) |
- |
|
|
|
| 6.3.2 & Table 3 (Minimum force at break before accelerated ageing) |
- |
|
|
|
| 6.3.2 & Table 3 (Minimum Elongation at break before accelerated ageing) |
- |
|
|
|
| 6.3.3 & Table 3 (Minimum force at break after accelerated ageing) |
- |
|
|
|
| 6.3.3 & Table 3 (Minimum Elongation at break after accelerated ageing) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 224 |
IS 10748 (2004) |
Hot - Rolled steel strip for welded tubes and pipes - Specification (Second Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8 & Table 3 (UTM) |
- |
|
|
|
| Cl 11 (Workmanship) |
- |
|
|
|
| Cl 12 & 13 (Length, Width & Thickness) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 225 |
IS 3074 (2013) |
Steel tubes for automotive purposes - Specification (Third Revision) |
- |
-
|
- View breakup
Rs.3750/- for CDS-1, CDS-2, CDS-3, CDS-4, CDS-5, Rs.4720/- for CDS-6, Rs.6750/- for CDS-7 & CDS-8, Rs.6750/- for CDS-9. Rs.3750/- for ERW/HFIW (ERW-1, ERW-2, ERW-3). Rs.4200/- for Mechanical testing charges.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 (Workmanship) |
- |
|
|
|
| 8.2,15,17,22, Table 3,5 &7 (Tensile Tests,IS 1608 Part 1) |
- |
|
|
|
| 8.3,18, (Flattening Test) |
- |
|
|
|
| 8.4 (Crushing Test) |
- |
|
|
|
| 8.5 (Drift Test) |
- |
|
|
|
| 6 (STRAIGHTNESS) |
- |
|
|
|
| 8.2,15,17,22, Table 3,5 &7 (Tensile Tests,IS 1608 Part 1) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 226 |
IS 963 (1958) |
Specification for chrome molybdenum steel bars and rods for aircraft purposes |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 (Freedom from defects) |
- |
|
|
|
| 7.5 (Hardness) |
- |
|
|
|
| 7.6.2 (i) Yield stess/.2% Proof stress, Mpa) |
- |
|
|
|
| 7.6.2 (ii)Ultimate Tensile Strength, Mpa) |
- |
|
|
|
| 7.6.2 (iii)Elongation, %) |
- |
|
|
|
| 7.6.2 (ii)Ultimate Tensile Strength, Mpa) |
- |
|
|
|
| 9 (Rolling Tolerances) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 227 |
IS 13428 (2005) |
Packaged natural mineral water specification (Second Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1.1 (Escherichia coli(or thermotolerant bacteria)) |
- |
|
|
|
| 6.1.2 (Coliform , bacteria) |
- |
|
|
|
| 6.1.3 (Faecal Streptococci ) |
- |
|
|
|
| 6.1.3 (Staphylococcus Aureus) |
- |
|
|
|
| 6.1.4 (Sulphite Reducing Anaerobes ) |
- |
|
|
|
| 6.1.5 (Pseudomonas Aeruginosa ) |
- |
|
|
|
| 6.1.6 (Yeast and Mould ) |
- |
|
|
|
| 6.1.7 (Salmonella ) |
- |
|
|
|
| 6.1.7 (Shigella) |
- |
|
|
|
| 6.1.8 (Vibrio cholera ) |
- |
|
|
|
| 6.1.8 (Vibrio parahemolyticus) |
- |
|
|
|
| 6.2 Table-1 i (Colour) |
- |
|
|
|
| 6.2 Table-1 ii (Odour) |
- |
|
|
|
| 6.2 Table-1 iii (Taste) |
- |
|
|
|
| 6.2 Table-1 iv (Turbidity) |
- |
|
|
|
| 6.2 Table-1 v (Total dissolved solids) |
- |
|
|
|
| 6.2 Table-1 vi (pH) |
- |
|
|
|
| 6.2 Table-2 i (Nitrate (as NO3)) |
- |
|
|
|
| 6.2 Table-2 ii (Nitrite (as NO2)) |
- |
|
|
|
| 6.2 Table-2 iii (Sulphide (as H2S)) |
- |
|
|
|
| 6.2 Table-2 iv (Manganese (as Mn)) |
- |
|
|
|
| 6.2 Table-2 v (Copper (as Cu)) |
- |
|
|
|
| 6.2 Table-2 vi (Zinc (as Zn)) |
- |
|
|
|
| 6.2 Table-2 vii (Flouride (as F)) |
- |
|
|
|
| 6.2 Table-2 viii (Barium (as Ba)) |
- |
|
|
|
| 6.2 Table-2 ix (Antimony (as Sb)) |
- |
|
|
|
| 6.2 Table-2 xi (Silver (as Ag)) |
- |
|
|
|
| 6.2 Table-2 xii (Chloride (as Cl)) |
- |
|
|
|
| 6.2 Table-2 xiii (Sulphate (as SO4),) |
- |
|
|
|
| 6.2 Table-2 xiv (Magnesium (as Mg)) |
- |
|
|
|
| 6.2 Table-2 xv (Calcium (as Ca)) |
- |
|
|
|
| 6.2 Table-2 xvi (Sodium (as Na)) |
- |
|
|
|
| 6.2 Table-2 xvii (Alkalinity (as HCO3)) |
- |
|
|
|
| 6.2 Table-2 xviii (Selenium (as Se)) |
- |
|
|
|
| 6.2 Table-2 xix (Mineral Oil) |
- |
|
|
|
| 6.2 Table-2 xx (Phenolic compounds (as C6H5OH)) |
- |
|
|
|
| 6.2 Table-3 i (Arsenic (as As)) |
- |
|
|
|
| 6.2 Table-3 ii (Cadmium (as Cd)) |
- |
|
|
|
| 6.2 Table-3 iv (Chromium (as Cr)) |
- |
|
|
|
| 6.2 Table-3 v (Mercury (as Hg)) |
- |
|
|
|
| 6.2 Table-3 vi (Lead (as Pb) |
- |
|
|
|
| 6.2 Table-3 vii (Nickel (as Ni)) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 228 |
IS 459 (1992) |
Corrugated and semi - Corrugated asbestos cement sheets - Specification (Third Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5, Table 1 (Dimensions & Tolerances - Type of Sheet - cl. 5) |
- |
|
|
|
| 5, Table 1, Figure 1,2 (Dimensions & Tolerances - Depth of Corrugation, D - Cl. 5) |
- |
|
|
|
| 5, Table 1, Figure 1,2 (Dimensions & Tolerances - Pitch of Corrugation, P - Cl. 5) |
- |
|
|
|
| 5, Table 1, Figure 1,2 (Dimensions & Tolerances - Overall width, B - Cl. 5) |
- |
|
|
|
| 5, Table 1, Figure 1,2 (Dimensions & Tolerances - Effective Width, C - Cl. 5) |
- |
|
|
|
| 5, Table 1, Figure 1,2 (Dimensions & Tolerances - Nominal Thickness, T - Cl. 5) |
- |
|
|
|
| 5, Table 1, Figure 1,2 (Dimensions & Tolerances - Length of Sheet, A - Cl. 5) |
- |
|
|
|
| 6.1 (Load Bearing Capacity Test - Cl. 6.1, IS 5913) |
- |
|
|
|
| 7 (General Appearance and Finish - Cl. 7.1) |
- |
|
|
|
| 7 (General Appearance and Finish - Cl. 7.2) |
- |
|
|
|
| 12 (Marking - Indication of source of manufacture - Cl. 12) |
- |
|
|
|
| 12 (Marking - Year & Date of manufacture - Cl. 12) |
- |
|
|
|
| 12 (Marking - Pictorial warning signs as given in IS 12081 (Part 2) : 1987 - Cl. 12) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 229 |
IS 13422 (1992) |
Disposable surgical rubber gloves specification |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.4 (Sterility) |
- |
|
|
|
| 4 (TYPES) |
- |
|
|
|
| 5.2.1 (General Characteristics and Dimensions) |
- |
|
|
|
| 5.2.2 and Table 1
Fig. 1 (Dimensions - Length) |
- |
|
|
|
| 5.2.2 and Table 1
Fig. 1 (Dimensions - Width) |
- |
|
|
|
| 5.2.2 and Table 1
Fig. 1 (Dimensions - Thickness of Finger) |
- |
|
|
|
| 5.2.2 and Table 1
Fig. 1 (Dimensions - Thickness of Palm) |
- |
|
|
|
| 5.2.2 and Table 1
Fig. 1 (Dimensions - Thickness of Cuff) |
- |
|
|
|
| 5.3 and Table 2 ( Tensile Strength Before Ageing) |
- |
|
|
|
| 5.3 and Table 2 ( Elongation at Break Before Ageing) |
- |
|
|
|
| 5.3 and Table 2 (Stress at 500% Elongation at Break Before Ageing) |
- |
|
|
|
| 5.3 and Table 2 ( Tensile StrengthAfter Accelerated Ageing) |
- |
|
|
|
| 5.3 and Table 2 ( Elongation at Break After Accelerated Ageing) |
- |
|
|
|
| 5.5 (Airtight Test) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 230 |
IS 13334 : Part 2 (2014) |
Skimmed milk powder - Specification: Part 2 extra grade (First Revision) |
EXTRA GRADE |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1 (ix) (Bacterial count (IS 5402)) |
- |
|
|
|
| Table 1 (x) (Coliform count (IS 5401 - Part 1)) |
- |
|
|
|
| Table 1 (xi) (Escherichia coli (IS 5887 - Part 1)) |
- |
|
|
|
| Table 1 (xii) (Coagulase positive Staphylococcus aureus (IS 5887 - Part 2)) |
- |
|
|
|
| Table 1 (xiii) (Salmonella (IS 5887 - Part 3)) |
- |
|
|
|
| Table 1 (xiv)(a) (Spore Count: a)Aerobic (Bacillus cereus) Type m (IS 5887 - Part 6)) |
- |
|
|
|
| Table 1 (xiv)(b) (Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type m (ISO 15213 : 2003)) |
- |
|
|
|
| Table 1 (xiv)(b) (Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type M (ISO 15213 : 2003)) |
- |
|
|
|
| Table 1 (xv) (Listeria monocytogenes (IS 14988 - Part 2 : 2001)) |
- |
|
|
|
| Table 1 (i) (Moisture (IS 116231or 16072)) |
- |
|
|
|
| Table 1 (ii) (Milk protein in milk solids not fat (IS 72192)) |
- |
|
|
|
| Table 1 (iii) (Milk fat (IS 117213) or Annex B) |
- |
|
|
|
| Table 1 (iv) (Insolubility index (IS 12759)) |
- |
|
|
|
| Table 1 (v) (Total ash (on dry basis), Annex B of IS 14433) |
- |
|
|
|
| Table 1 (vi) (Titratable acidity (IS 11766)) |
- |
|
|
|
| Table 1 (viii) (Scorched particles (equivalent to Disc B) (IS 13500)) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 231 |
IS 12818 (2010) |
Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.6 (Vicat Softening Temperature
IS 12235 (Part 2).) |
- |
|
|
|
| 9.3 (Density
IS 12235 (Part 14)) |
- |
|
|
|
| 9.1 ( Visual Appearance) |
- |
|
|
|
| 7.2 and Table 5, 6 & 7
Fig 1B (Wall thickness, Min) |
- |
|
|
|
| 7.2 and Table 5, 6 & 7
Fig 1B (Mean Outer Diameter over Connection) |
- |
|
|
|
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B (Outer Diameter at any point ) |
- |
|
|
|
| 7.2 and Table 5, 6 & 7
Fig 1B (Mean Outer Diameter of Pipe, Min) |
- |
|
|
|
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B (Mean Outer Diameter of Pipe) |
- |
|
|
|
| 7.2 and Table 5, 6 & 7
Fig 1B (Mean Outer Diameter of Pipe , Max) |
- |
|
|
|
| 7.2 and Table 5, 6 & 7
Fig 1B (Outer Diameter at any point , Min) |
- |
|
|
|
| 8.4 (Sealing rings - Hardness) |
- |
|
|
|
| 9.1 ( Visual Appearance) |
- |
|
|
|
| 5 (COLOUR) |
- |
|
|
|
| 8.4.1 and Table 13
Fig 3B & 4B (Dimensions of sealing elements) |
- |
|
|
|
| 7.4 Table 8 & 9
Fig 1 (Effective length, l2) |
- |
|
|
|
| 7.4 Table 8 & 9
Fig 1 (Segmental length, l3) |
- |
|
|
|
| 7.4 Table 8 & 9
Fig 1 (Segmental length, l4) |
- |
|
|
|
| 7.4 Table 8 & 9
Fig 1 (Segmental length, l5) |
- |
|
|
|
| 7.3.1 (No.of Ribs) |
- |
|
|
|
| 7.3.2 (Rib height) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 232 |
IS 8249 (2019) |
Zinc sulphate heptahydrate, agricultural grade - Specification (First Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| (Clauses 3.2 and 6.2) Table 1 (Matter insoluble in water) |
- |
|
|
|
| (Clauses 3.2 and 6.2) Table 1 (Zinc (as Zn)) |
- |
|
|
|
| (Clauses 3.2 and 6.2) Table 1 (Lead (as Pb)) |
- |
|
|
|
| (Clauses 3.2 and 6.2) Table 1 (Copper (as Cu)) |
- |
|
|
|
| (Clauses 3.2 and 6.2) Table 1 (Magnesium (as Mg)) |
- |
|
|
|
| (Clauses 3.2 and 6.2) Table 1 (pH) |
- |
|
|
|
| (Clauses 3.2 and 6.2) Table 1 (Cadmium (as Cd)) |
- |
|
|
|
| (Clauses 3.2 and 6.2) Table 1 (Arsenic (as As)) |
- |
|
|
|
| (Clauses 3.2 and 6.2) Table 1 (Sulphur (as S)) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 233 |
IS 455 (2015) |
Portland slag cement - Specification |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 - Table - 1 i (Insoluble residue - Cl 6.9 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 ii (Magnesia - Cl 6.8 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 iii (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 6.11 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 v (Loss on ignition - Cl 6.2 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 vi (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
| 7 Table 1 iv c (Compretsive Strenqth 672 ± 4 hr
IS 4031(Part 6)) |
- |
|
|
|
| 7 Table 1 iv b (Compretsive Strenqth 168 ± 2 hr
IS 4031(Part 6)) |
- |
|
|
|
| 7 Table 1 iv a (Compretsive Strenqth .72 ± 1 hr
IS 4031(Part 6)) |
- |
|
|
|
| 7 Table 1 iii b (Setting Time ( by Vicat Apparatus ), Final
IS 4031(Part 5)) |
- |
|
|
|
| 7 Table 1 iii a (Setting Time ( by Vicat Apparatus ),Initial
IS 4031(Part 5)) |
- |
|
|
|
| 7 Table 1 ii b (Soundness, Autoclave expansion
IS 4031(Part 3) ) |
- |
|
|
|
| 7 Table 1 ii a (Soundness, Le-Chate1ier expansion
IS 4031(Part 3) ) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 234 |
IS 8042 (2015) |
White portland cement - Specification (Third Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 - Table - 1 i (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
| 5 - Table - 1 ii (Iron oxide - Cl 4.5 of IS 4032:1985) |
- |
|
|
|
| 5 - Table - 1 iii (Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
|
|
|
| 5 - Table - 1 iv (Magnesia - Cl 4.8 of IS 4032:1985) |
- |
|
|
|
| 5 - Table - 1 v (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
|
|
|
| 5 - Table - 1 vi (Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
|
|
|
| 5 - Table - 1 vii (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
| 6 -Table 2- i (Fineness 4031 Part 2) |
- |
|
|
|
| 6 -Table 2- ii- a (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
| 6 -Table 2- ii- b (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
| 6 -Table 2- iii- a (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
| 6 -Table 2-iii- b (Setting Time Final- 4031 Part 5) |
- |
|
|
|
| 6 -Table 2- iv- a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 6 -Table 2- iv- b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 6 -Table 2- iv- c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 235 |
IS 651 (2007) |
Glazed stoneware pipes and fittings - Specification (Sixth Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 7.4 (Acid Resistance Test) |
- |
|
|
|
| Clause 7.5 (Alkali Resistance Test) |
- |
|
|
|
| 7.2 (Hydraulic Test) |
- |
|
|
|
| 7.3 (Absorption Test) |
- |
|
|
|
| 10.1-Table 1 (INTERNAL DIAMETER) |
- |
|
|
|
| 11.1-Table 1 (
Mean Thickness of Barrel and of Socket) |
- |
|
|
|
| 14-Table 1 (Internal Depth of Socket) |
- |
|
|
|
| 14-Table 3 (Length of Grooving of Spigot) |
- |
|
|
|
| 14 (The interior of the sockets shall be conical, having a minimum taper) |
- |
|
|
|
| 5.1 (GENERAL QUALITY) |
- |
|
|
|
| 5.1 (GENERAL QUALITY) |
- |
|
|
|
| 5.2(a) (GENERAL QUALITY) |
- |
|
|
|
| 5.2(b) (GENERAL QUALITY) |
- |
|
|
|
| 5.2(c) (GENERAL QUALITY) |
- |
|
|
|
| 6 ( GLAZING) |
- |
|
|
|
| 7.3 (Absorption Test) |
- |
|
|
|
| 14-Table 2 (Excess Shoulder Measurment) |
- |
|
|
|
| 14-Table 3 (Length of Grooving of Spigot) |
- |
|
|
|
| 12.2 (STRAIGHTNESS OF BARRELS OR STRAIGHT AND TAPER PIPES-Length of Junction) |
- |
|
|
|
| 13.1-Table 2 (Dimensions of One-Quarter Bends-Internal Diameter) |
- |
|
|
|
| 13.1-Table 2 (Dimensions of One-Quarter Bends-r) |
- |
|
|
|
| 13.1-Table 2 (Dimensions of One-Quarter Bends-a) |
- |
|
|
|
| 13.1-Table 2 (Dimensions of One-Quarter Bends-angle) |
- |
|
|
|
| 13.1-Table 3 (Dimensions of One-Eighth Bends--Internal Diameter) |
- |
|
|
|
| 13.1-Table 3 (Dimensions of One-Eighth Bends-r) |
- |
|
|
|
| 13.1-Table 3 (Dimensions of One-Eighth Bends-angle) |
- |
|
|
|
| 13.1-Table 4 (Dimension of One-Sixteenth Bends-Internal Diameter) |
- |
|
|
|
| 13.1-Table 5 (Dimension of One-Quarter Taper Bends-d) |
- |
|
|
|
| 13.1-Table 5 (Dimension of One-Quarter Taper Bends-D) |
- |
|
|
|
| 13.1-Table 5 (Dimension of One-Quarter Taper Bends-r) |
- |
|
|
|
| 13.1-Table 5 (Dimension of One-Quarter Taper Bends-a) |
- |
|
|
|
| 13.1-Table 5 (Dimension of One-Quarter Taper Bends-Angle) |
- |
|
|
|
| 13.1-Table 6 (Dimensions of One-Eighth Taper Bends-d) |
- |
|
|
|
| 13.1-Table 6 (Dimensions of One-Eighth Taper Bends-D) |
- |
|
|
|
| 13.2 (The angle at junction) |
- |
|
|
|
| 14 (The interior of the sockets shall be conical, having a minimum taper) |
- |
|
|
|
| 15 (GROOVING Length) |
- |
|
|
|
| 15 (GROOVING Depth) |
- |
|
|
|
| 17-Table 7 (Dimensions of Half-Section One-Quarter Channel Bends-Internal Diameter) |
- |
|
|
|
| 17-Table 7 (Dimensions of Half-Section One-Quarter Channel Bends-r) |
- |
|
|
|
| 17-Table 7 (Dimensions of Half-Section One-Quarter Channel Bends-a) |
- |
|
|
|
| 17-Table 7 (Dimensions of Half-Section One-Quarter Channel Bends-Angle) |
- |
|
|
|
| 17-Table 8 (Dimensions of Half-Section One-Eighth Channel Bends-Internal Diameter) |
- |
|
|
|
| 17-Table 8 (Dimensions of Half-Section One-Eighth Channel Bends-Angle) |
- |
|
|
|
| 17-Table 9 (Dimensions of Half-Section One-Sixteenth Channel Bends-Internal Diameter) |
- |
|
|
|
| 17-Table 10 (Dimensions of Channel Interceptors-Internal Diameter) |
- |
|
|
|
| 17-Table 10 (Dimensions of Channel Interceptors-A) |
- |
|
|
|
| 17-Table 10 (Dimensions of Channel Interceptors-B) |
- |
|
|
|
| 17-Table 10 (Dimensions of Channel Interceptors-C) |
- |
|
|
|
| 17-Table 10 (Dimensions of Channel Interceptors-D) |
- |
|
|
|
| 17-Table 10 (Dimensions of Channel Interceptors-E) |
- |
|
|
|
| 17-Table 10 (Dimensions of Channel Interceptors-F) |
- |
|
|
|
| 17-Table 10 (Dimensions of Channel Interceptors-G) |
- |
|
|
|
| 17-Table 11 (Dimensions of Round Mouth Gully traps-Type) |
- |
|
|
|
| 17-Table 11 (Dimensions of Round Mouth Gully traps-Size) |
- |
|
|
|
| 17-Table 11 (Dimensions of Round Mouth Gully traps-A) |
- |
|
|
|
| 17-Table 11 (Dimensions of Round Mouth Gully traps-C) |
- |
|
|
|
| 17-Table 11 (Dimensions of Round Mouth Gully traps-d) |
- |
|
|
|
| 17-Table 11 (Dimensions of Round Mouth Gully traps-D) |
- |
|
|
|
| 17-Table 11 (Dimensions of Round Mouth Gully traps-D') |
- |
|
|
|
| 17-Table 11 (Dimensions of Round Mouth Gully traps-E) |
- |
|
|
|
| 17-Table 11 (Dimensions of Round Mouth Gully traps-F) |
- |
|
|
|
| 17-Table 11 (Dimensions of Round Mouth Gully traps-F') |
- |
|
|
|
| 17-Table 11 (Dimensions of Round Mouth Gully traps-G) |
- |
|
|
|
| 17-Table 12 (Dimensions of Square Mouth Gully Traps-Type) |
- |
|
|
|
| 17-Table 12 (Dimensions of Square Mouth Gully Traps-Size) |
- |
|
|
|
| 17-Table 12 (Dimensions of Square Mouth Gully Traps-A) |
- |
|
|
|
| 17-Table 12 (Dimensions of Square Mouth Gully Traps-C) |
- |
|
|
|
| 17-Table 12 (Dimensions of Square Mouth Gully Traps-d) |
- |
|
|
|
| 17-Table 12 (Dimensions of Square Mouth Gully Traps-D) |
- |
|
|
|
| 17-Table 12 (Dimensions of Square Mouth Gully Traps-D') |
- |
|
|
|
| 17-Table 12 (Dimensions of Square Mouth Gully Traps-E) |
- |
|
|
|
| 17-Table 12 (Dimensions of Square Mouth Gully Traps-F) |
- |
|
|
|
| 17-Table 12 (Dimensions of Square Mouth Gully Traps-F') |
- |
|
|
|
| 17-Table 12 (Dimensions of Square Mouth Gully Traps-G) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 236 |
IS 4246 (2002) |
Domestic gas stoves for use with liquefied petroleum gases - Specification (Fifth Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5 and 5 of IS 5116 . (All copper and copper alloy parts shall pass mercurous nitrate test .) |
- |
|
|
|
| Cl 10 (cl 9.1.1 of 1S 51 I6 ) (Injector Jet shall be made of metal, with or
without ceramic tip. The melting point of the
metal shall not be less than 650°C.) |
- |
|
|
|
| Cl.24(Annexure E) (on no account the carbon monoxidel
carbon dioxide ratio of the exhaust gases of any burner.
operating at any consumption at which the burner is
stable at gas inlet pressure from 2452 kN/m2 to
3432 kN/m2 (25 gf/cm2 to 35 gf/cm2), exceed 0.02.) |
- |
|
|
|
| Cl.23 (There shall be no extinction of the flames on any
of the burners operating at maximum consumption
when the appliance is placed in a general (not
localized) current of air with a velocity of 2 m/s, as
measured with a rotating vane anemometer. The
location of the appliance relative to neighboring walls
and the direction of the draught shall be varied to
correspond to likely conditions of appliance installation.
This applies for all pressures from 2452 kN/m2 to
3432 kN/m2 (25 gf/cm2 to 35 gf/cm2).) |
- |
|
|
|
| Cl 22 (A vessel, 150 mm diameter, full of water, shall
be placed on the burner and the burner lighted at ‘ON’
position of the tap for one hour. After the test, no soot
(unburned carbon) shall be deposited on the burner
and on the bottom of the vessel. This applies for all
pressures from 2452 kN/m2 to 3432 kNlm2
(25 gf/cm2 to 35 gf/cm2)) |
- |
|
|
|
| Cl 21 (When operated at pressures 25-35 gmf/cm² there shall be no extinction of flame on any of the burner operating at the maximum of the burner when the appliance is placed in thenormal current of air with the velocity of 2 m/s as measured with a rotating vane anemometer.) |
- |
|
|
|
| Cl.20 (The ignition of the burner flames, their operation and
turning ‘OFF’ shall not give rise to undue or excessive
noise during all the operations.) |
- |
|
|
|
| Cl19.3 (The fixed minimum pilot rate shall be sufficient
to relight the main burnerat2452 kN/m2 (25 gf/cm2)
gas inlet pressure.) |
- |
|
|
|
| Cl.23 (There shall be no extinction of the flames on any
of the burners operating at maximum consumption
when the appliance is placed in a general (not
localized) current of air with a velocity of 2 m/s, as
measured with a rotating vane anemometer. The
location of the appliance relative to neighboring walls
and the direction of the draught shall be varied to
correspond to likely conditions of appliance installation.
This applies for all pressures from 2452 kN/m2 to
3432 kN/m2 (25 gf/cm2 to 35 gf/cm2).) |
- |
|
|
|
| Cl 22 (A vessel, 150 mm diameter, full of water, shall
be placed on the burner and the burner lighted at ‘ON’
position of the tap for one hour. After the test, no soot
(unburned carbon) shall be deposited on the burner
and on the bottom of the vessel. This applies for all
pressures from 2452 kN/m2 to 3432 kNlm2
(25 gf/cm2 to 35 gf/cm2)) |
- |
|
|
|
| Cl 21 (When operated at pressures 25-35 gmf/cm² there shall be no extinction of flame on any of the burner operating at the maximum of the burner when the appliance is placed in thenormal current of air with the velocity of 2 m/s as measured with a rotating vane anemometer.) |
- |
|
|
|
| Cl.20 (The ignition of the burner flames, their operation and
turning ‘OFF’ shall not give rise to undue or excessive
noise during all the operations.) |
- |
|
|
|
| Cl 19.2 (Pilot flames shall be stable, without lifting
or soot deposition, at gas inlet pressure from
2 452kN/m2to3432 kN/m2 (25 gf/cm2 to 35 gf7cm2).) |
- |
|
|
|
| Cl 19.1.1 (When the gas consumption of a burner is
reduced to simmer after operating for half an hour at
full ‘ON’, the flame shall not extinguish, blow off,
strike back or form soot when tested with commercial
LPG at 2942 kN/m2 (30 gf/cm2) gas inlet pressure.) |
- |
|
|
|
| Cl 19.1 (It shall be possible to operate the appliance with
taps fully open at gas inlet pressure from 2452 kN/m2
to 3432 kN/m2 (25 gflcmz to 35 gf/cm2) without the
flame extinguishing, blowing off or striking back and
without the formation of soot) |
- |
|
|
|
| Cl18.4 (Cl14 of IS 5116) (Shall be protected against adjustment by
unauthorized persons.) |
- |
|
|
|
| Cl18.4 (Cl14 of IS 5116) (Shall be free from any weakness in design
which will give rise to failure to danger; and) |
- |
|
|
|
| Cl18.4 (Cl14 of IS 5116) (Shall open and close in times not
exceeding the following limits:Opening from cold
Closing from the
fully heated
condition
Time
Manually Non-manually
Operated, Operated,
seconds seconds
40 90
75 90) |
- |
|
|
|
| Cl18.4 (Cl14 of IS 5116) (Shall be actuated only by a pilot flame, if
provided, to ignite the main burner
without failure or delay;) |
- |
|
|
|
| Cl18.4 (Cl14 of IS 5116) (Shall, after flame failure, stop all gas flow
to the main burner;) |
- |
|
|
|
| Cl18.4 (Cl14 of IS 5116) (Shall prevent gas from being supplied to
the main burner until the pilot flame, if
provided, is established;) |
- |
|
|
|
| Cl18.3 (When the burner is ignited from a pilot flame
and / or by an electric/electronic method, the ignition
and flame travel shall be smooth at pressure from
2452 kN/m2 to 3432 kN/m2 (25 gf/cm2 to 35 gf/cm2)
with the burner tap turned full ‘ON’ and ignition shall
be effected without undue delay after turning on taps) |
- |
|
|
|
| cl 18.2 (If a flame is applied to any of the outer row of the
burner ports when the gas is flowing, flame travel shall
be complete. This applies for the all pressures from
2452 to 3432 kN/m2 (25 to 35 gf/cm2), taps being
fully opened and without a pan over the burner.) |
- |
|
|
|
| cl 18.1 (the burner or burners are lighted by automatic ignition
(battery of flint-operated) or by a pilot flame, it shall
not be possible for gas to be admitted to the main
burner without being smoothly ignited by the pilot
flame. Each burner should be at room temperature at
the beginning of the test and should be tested in turn) |
- |
|
|
|
| cl 18.1 (There shall be easy and safe access for lighting
and relighting each burner by a match stick and it
shall be easy to see that the burner is lighted. Where) |
- |
|
|
|
| Cl17.2.2 (When the gas consumption of a burner is
reduced to simmer as described in 17.2, the flame shall
not extinguish, blow off, strike back or form soot when
tested with commercial LPG at 2942 kN/m2
(30 gf/cm2) gas inlet pressure.) |
- |
|
|
|
| Cl17.2.1 (b) For burners above 60 I/h gas rate, 22 I/h or 26
percent of the rated capacity whichever is
higher.) |
- |
|
|
|
| Cl17.2.1 (It shall be possible to reduce the consumption
rate of the burner to the following extent by providing
a fixed simmer orifice in the gas tap:
a) For burners up to 60 I/h gas rate, 35 percent
of the rated capacity; and) |
- |
|
|
|
| Cl 17.1 (Each burner assembly under separate ‘ON/OFF’
control shall give + 8 percent of the manufacturers’
specified gas consumption in I/h or heat input in
kcaVh at 2942 kN/m2 (30 gf/cmz)) |
- |
|
|
|
| Cl.15 (When tested as specified in Annex C, the vertical
resultant deflection of the top surface measured at the
centre of length of the body, shall not exceed 2 mm
and the distance between the opposite sides
(lengthwise and widthwise) shall not change by more
than 5 mm.) |
- |
|
|
|
| Cl 14.2 (The position of the gas inlet shall allow
connection to a gas supply on either side of the
appliance. Inlet connection at the rear is also
permitted. It shall be possible to change gas inlet from
one side to other side easily by standard tools.) |
- |
|
|
|
| Cl 14.1(Cl 18.4 of IS 5116) (The
external surface of the gas rail shall be treated
to resist corrosion.) |
- |
|
|
|
| Cl 14.1(Cl 18.4 of IS 5116) (The pipe/tube used for main gas rail shall
be of mild steel. The wall thickness of main gas
rail shall be 1.6 mm + no Iimit/–0.15 mm.) |
- |
|
|
|
| Cl 14.1(Cl 18.2 of IS 5116) (Where nozzles for flexible tubing are
fitted, they shall be so positioned as to facilitate
fitting of the tubing and also to prevent heating
of the tubing to more than 60°C. Shape of
nozzles is given in Fig. 7.) |
- |
|
|
|
| Cl 12.1.1 (Loose pan supports shall be so designed that
it is not possible to place them firmly in other than
proper position.) |
- |
|
|
|
| Cl 12.1 (The design of the pan supports shall be such that
it is practicable to support a pan of 100mm diameter,
over at least one top burner without the use of loose
rings, and such that 125 mm diameter vessel remains
stable over each burner. Prongs of the support shall
have suitable taper to accommodate round bottom
pans.) |
- |
|
|
|
| Cl 11.2 (For burners having centre flame,provision shall be made to protect the centre flame from pans resting directly on burner top and smothering the centre flame.) |
- |
|
|
|
| Cl 11 (cl 10.5 of 1S 51 I6 ) (If the burner is made and assembled in
two or more parts they shall be so designed to
provide proper self-locating arrangement so
that they are always re-assembled to its
original design preventing any maladjustment
in their assembly. This shall also be applicable
for primary air regulators.) |
- |
|
|
|
| Cl 11 (cl 10.4 of 1S 51 I6 ) (If primary air regulators are used, they
shall be so designed that they are not easily
maladjusted by the user and the construction
shall be such that primary air adjustment can
be made with the burner in place ( see Fig. 6 ).) |
- |
|
|
|
| Cl 11 (cl 10.3 of 1S 51 I6 ) (The lightness of the joints in the burner
assembly shall not depend upon adhesives or any kind ot packmg) |
- |
|
|
|
| Cl 11 (cl 10.2 of 1S 51 I6 ) (The burner supports shall be rigid and
shall be fixed in their place. Their construction
shall ensure the stability of the burners and
shall prevent their undue movement in a
horizontal plane.) |
- |
|
|
|
| Cl 11 (cl 10.1 of 1S 51 I6 ) (The construction of the burners and the
assembly shall allow their dismantling from
the supports easily with or without the use of
tools (see Fig. 5 for guidance).) |
- |
|
|
|
| Cl 10 (cl 9.1 of 1S 51 I6 ) (The injector Jets shall be fixed calibrated
type and it shall not be possible to loosen them
without the use of tools. The dimensions of the
injector Jet shall conform to the following
requirements:
Across flats
6 mm. nominal
M 5 or 1BA) |
- |
|
|
|
| Cl 10 (cl 9.1 of 1S 51 I6 ) (Threads
6 mm, Min) |
- |
|
|
|
| Cl 10 (cl 9.1 of 1S 51 I6 ) (Projection from the face
of mounting) |
- |
|
|
|
| Cl 10 (cl 9.1 of 1S 51 I6 ) (The injector Jets shall be fixed calibrated
type and it shall not be possible to loosen them
without the use of tools. The dimensions of the
injector Jet shall conform to the following
requirements:
Across flats
6 mm. nominal
M 5 or 1BA) |
- |
|
|
|
| Cl 9 (Cl 8.11.2 of IS 5116 ) (The niting means adopted shall be
sufficiently robust to withstand normal use
without distortion or damage.) |
- |
|
|
|
| Cl 9 (Cl 8.11.1 of IS 5116 ) (Simmer flame shall be obtained by fixed
simmer orifice.) |
- |
|
|
|
| Cl 9 (Cl 8.11 of IS 5116 ) (Taps having an 'OFF' position shall have
positive stops at the 'OFF' and simmer position
except that special purpose taps (for appliance
incorporating auto or self ignition device), for
example, taps with simmering position in
between 'OFF' and 'ON' may have a movement
beyond the simmer position with a positive stop) |
- |
|
|
|
| Cl 9 (Cl 8.10 of IS 5116 ) (Screw-down valves shall be so designed
that it is impossible to withdraw completely the
valve stem in the normal operation of the tap.) |
- |
|
|
|
| Cl 9 (Cl 8.9 of IS 5116 ) (Screws, nuts, etc, which regulate the
tension of taps valve or springs, shall not loosen
in operation of the appliance. It shall not be
possible to cause a leak during normal manual
operation of tap.) |
- |
|
|
|
| Cl 9 (Cl 8.8 of IS 5116 ) (All controls or taps shall be easy to operate
at all temperatures normally attained in use.) |
- |
|
|
|
| Cl 9 (Cl 8.7 of IS 5116 ) (Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(C1 3.0 Min)) |
- |
|
|
|
| Cl 9 (Cl 8.7 of IS 5116 ) (Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(B1 0.4 Min)) |
- |
|
|
|
| Cl 9 (Cl 8.7 of IS 5116 ) (Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(A1 1.2 Min)) |
- |
|
|
|
| Cl 9 (Cl 8.7 of IS 5116 ) (Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(D 2.80 Min)) |
- |
|
|
|
| Cl 9 (Cl 8.7 of IS 5116 ) (Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(C 3.0 Min)) |
- |
|
|
|
| Cl 9 (Cl 8.7 of IS 5116 ) (Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(B 0.4 Min)) |
- |
|
|
|
| Cl 9 (Cl 8.7 of IS 5116 ) (Taper plug taps shall have dimensional
allowances when in 'OFF' position given in
Fig. 4.(A 1.1 Min) |
- |
|
|
|
| Cl 9 (Cl 8.6 of IS 5116 ) (Each taper plug tap shall be spring-loaded
to maintain a gas-tight fit. Helical springs
fitted in taps and valves shall have flattened
ends, which shall be rounded before fitting.) |
- |
|
|
|
| Cl 9 (Cl 8.5 of IS 5116 ) (Taps shall be so made that in normal use
and with reasonable application of lubricant, the
gas passages do not become blocked (see Fig. 3).) |
- |
|
|
|
| Cl 9 (Cl 8.4 of IS 5116 ) (Preferably all taps (excluding pilot taps)
should lock in the 'OFF' position but in all cases
it shall be impossible for any handle or tap to
move accidentally, for example, by the weight
of plugs or handles or when caught by clothing.
If this requirement is satisfied by means of an
automatic locking device, the tap shall be easy
to operate with one hand.) |
- |
|
|
|
| Cl 9 (Cl 8.3 of IS 5116 ) (Where taps are fitted with adjustable stops,
there shall be means for locking the stops in
position. If screws are used for this purpose,
they shall not lead into gas passages) |
- |
|
|
|
| Cl 9 (Cl 8.2 of IS 5116 ) (The direction of rotation of a tap knob (handle) off-on-simmer shall be anticlockwise.) |
- |
|
|
|
| Cl 9 (Cl 8.2 of IS 5116 ) (Taps shall be designed so that when placed in any position on &viewed from a distance of 3 m, will definately indicate whether the valve is open or close or in intermediate position.) |
- |
|
|
|
| Cl 9 (Cl 8.2 of IS 5116 ) (All taps shall close in the same direction.) |
- |
|
|
|
| Cl 9 (Cl 8.2 of IS 5116 ) (The ON,OFF and any fixed position of tap handles shall be clearely & durably indicated or shall be obvious by design or position. Where it is not obvious which tap operates which burner , some indication shall be give) |
- |
|
|
|
| Cl 9 (Cl 8.1 of IS 5116 ) (The appliance shall have at least one tap for each burner.) |
- |
|
|
|
| Cl 8.3 (Except for burners, all other parts, namely, springs,
screws, bolts and nuts, pipes, pins, etc, which are
visible can be removed for maintenance shall be of
corrosion resistant material or treated to resist
corrosion appropriate to the conditions of use.) |
- |
|
|
|
| Cl 8.2 of IS 4246 (The external finished surfaces shall be easily cleanable.) |
- |
|
|
|
| Cl 8.1 ,(Cl 7.5 of IS 5116) (Concealed tubular fittings liable to corrode shall be protected by bituminous paint or other equally protective materia) |
- |
|
|
|
| Cl 8.1 ,(Cl 7.4.2 of IS 5116) (Resistance to Heating) |
- |
|
|
|
| Cl 8.1 ,(Cl 7.4.1 of IS 5116) (Resistance to Abrasion) |
- |
|
|
|
| Cl 8.1 (Cl 7.3.2 of IS 5116) (Adhesion Test) |
- |
|
|
|
| Cl 8.1 (The top flat surface of the body of the appliance, if plated, shallhave a coating of minimum of 10 microns of nickel followed by0.2 microns minimum of chromium.) |
- |
|
|
|
| Cl 8.1 (In addition to the relevant requirements given
in 7 of IS 5116, the requirements given in 8.2 and 8.3
shall apply. given in Annex E.) |
- |
|
|
|
| Cl 8.1 (In addition to the relevant requirements given
in 7 of IS 5116, the requirements given in 8.2 and 8.3
shall apply.) |
- |
|
|
|
| Cl 8.1 (In addition to the relevant requirements given
in 7 of IS 5116, the requirements given in 8.2 and 8.3
shall apply.) |
- |
|
|
|
| Cl 7 (Cl 7) |
- |
|
|
|
| Cl 6.6 (Cl 6.6) |
- |
|
|
|
| Cl 6.5 (Cl 6.5) |
- |
|
|
|
| Cl 6.4 (Cl 6.4) |
- |
|
|
|
| Cl 6.3 (Cl 6.3) |
- |
|
|
|
| Cl 6.2 (The parts of burner shall not become disconnected during operation of appliance.the centers of adjoining burner shall not be less than 180 mm.) |
- |
|
|
|
| Cl 6 , DESIGN FOR MAINTENANCE (Cl 6.1) |
- |
|
|
|
| IS 5116 . (The number of glass fragments contained in a square of side 50mm located in the area of the largest pieces shall be at least 40 numbers. (Test Method as per Cl.15.2)) |
- |
|
|
|
| IS 5116 . (Toughened glass shall fragment into small particles.) |
- |
|
|
|
| IS 5116 . (When a pan support for an uncovered burner is in contact withthe glass ceramic surface of the gas stove, the surface area ofthe pan support in contact with the glass ceramic surface shallbe at least 25 mm2.) |
- |
|
|
|
| Cl 5 and 5 of IS 5116 . (IS 5116) |
- |
|
|
|
| Cl 5 and 5 of IS 5116 . (IS 5116) |
- |
|
|
|
| Cl 5 and 5 of IS 5116 . (IS 5116) |
- |
|
|
|
| Cl 17.1 (Each burner assembly under separate ‘ON/OFF’
control shall give + 8 percent of the manufacturers’
specified gas consumption in I/h or heat input in
kcaVh at 2942 kN/m2 (30 gf/cmz)) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 237 |
IS 13334 : Part 1 (2014) |
Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.4 (The flavour of the product or of the reconstituted
milk shall be pleasant and clean (see IS 10030).) |
- |
|
|
|
| 4 (Description) |
- |
|
|
|
| 5.6 (Moisture) |
- |
|
|
|
| 5.6 (Milk protein in milk solids not fat) |
- |
|
|
|
| 5.6 (Milk fat) |
- |
|
|
|
| 5.6 (Insolubility index) |
- |
|
|
|
| 5.6 (Milk fat) |
- |
|
|
|
| 5.6 (Total ash (on dry basis)) |
- |
|
|
|
| 5.6 (Titratable acidity (lactic acid)) |
- |
|
|
|
| 5.6 (Scorched particles) |
- |
|
|
|
| 5.6 (Bacterial count) |
- |
|
|
|
| 5.6 (Coliform count ) |
- |
|
|
|
| 5.6 (Escherichia coli) |
- |
|
|
|
| 5.6 (Coagulase positive Staphylococcus aureus) |
- |
|
|
|
| 5.6 (Salmonella) |
- |
|
|
|
| 5.6 (Spore count, Aerobic (Bacillus cereus)) |
- |
|
|
|
| 5.6 (Spore count, Anaerobic (Sulfite reducing Clostridia)) |
- |
|
|
|
| 5.6 (Listeria monocytogenes) |
- |
|
|
|
|
Complete
|
|
- |
- - |
| 238 |
IS 12786 (1989) |
Irrigation equipment - Polyethylene pipes for irrigation laterals - Specification |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 and Table 1 (DIMENSIONS OF PIPES - outside diameters) |
- |
|
|
|
| 5 and Table 1 (DIMENSIONS OF PIPES - wall thickness shall) |
- |
|
|
|
| 7.2 (Reversion Test) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 239 |
IS 7224 (2006) |
Iodized salt, vacuum evaporated iodized salt and refined iodized salt - Specification (Second Revision) |
Iodized salt, vacuum evaporated iodized salt & refined |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.2 (Particle Size) |
- |
|
|
|
| Clause 4.3 Table 1 (Moisture content) |
- |
|
|
|
| Clause 4.3 Table 1 (water insoluble matter) |
- |
|
|
|
| Clause 4.3 Table 1 (Chloride Content(as Nacl)) |
- |
|
|
|
| Clause 4.3 Table 1 (Matter soluble in water other than sodium chloride) |
- |
|
|
|
| Clause 4.3 Table 1 (Calcium (as Ca)) |
- |
|
|
|
| Clause 4.3 Table 1 (Magnesium (as mg)) |
- |
|
|
|
| Clause 4.3 Table 1 (Sulphate (as SO4 ),) |
- |
|
|
|
| Clause 4.3 Table 1 (Iodine content, a) Manufacturers Level ) |
- |
|
|
|
| Clause 4.3 Table 1 (b) Distribution channel including retailer) |
- |
|
|
|
| Clause 4.3 Table 1 (Alkalinity (as Na2CO3),) |
- |
|
|
|
| Clause 4.3 Table 1 (Lead as (Pb)) |
- |
|
|
|
| Clause 4.3 Table 1 (Arsenic(as As)) |
- |
|
|
|
| Clause 4.3 Table 1 (Iron(as Fe)) |
- |
|
|
|
| Clause 4.3 Table 1 (Lead as (Pb)) |
- |
|
|
|
| Clause 4.3 Table 1 (Arsenic(as As)) |
- |
|
|
|
| Clause 4.3 Table 1 (Iron(as Fe)) |
- |
|
|
|
| Clause 4.2 (Particle Size) |
- |
|
|
|
| 4.4 (Anticaking agents (Potassium Ferrocyanide)) |
- |
|
|
|
| Clause no4.1 (Description) |
- |
|
|
|
|
Partial
|
|
- |
- - |
| 240 |
IS 2062 (2011) |
Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) |
- |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 18 (Weight) |
- |
|
|
|
| Cl 15 (Length, Width & Thickness) |
- |
|
|
|
| Cl 12 (Sudden Load Applied) |
- |
|
|
|
| Cl 10.3 (UTM) |
- |
|
|
|
|
Partial
|
|
- |
- - |