| 1 |
IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- |
-
|
150000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking and instructions) |
- |
4500 |
|
Cl. 5 : Marking and instructions |
| 6(Hazardous radiations) |
- |
0 |
|
Qualitative Test |
| 7(Heating under normal operating conditions) |
- |
12000 |
|
Cl. 7 : Heating under normal operating condition |
| 8(Constructional requirements with regard to the protection against electric shock) |
- |
7500 |
|
Cl. 8 : Construction requirments with regard to the protection against electric shock |
| 9(Electric shock hazard under normal operating conditions) |
- |
15000 |
|
Cl. 9 : "Electric shock hazard under normal
operating conditions" |
| 10(Insulation requirements) |
- |
18000 |
|
Cl. 10 : Insulation requirments |
| 11(Fault conditions) |
- |
24000 |
|
Cl. 11 : Fault conditions |
| 12(Mechanical strength) |
- |
19500 |
|
Cl. 12 : Mechanical Strength |
| 13(CLEARANCES and CREEPAGE DISTANCES) |
- |
12000 |
|
Cl. 13 : clearance and creepage distances |
| 14(Components) |
- |
0 |
|
Qualitative Test |
| 15(TERMINALS) |
- |
3000 |
|
Cl. 15 : Terminals |
| 16(External flexible cords) |
- |
7500 |
|
Cl. 16 : External flexible cord |
| 17(Electrical connections and mechanical fixings) |
- |
3000 |
|
Cl. 17 : Electrical connection and mechanical fixings |
| 18(Mechanical strength of picture tubes and protection against the effects of implosion) |
- |
0 |
|
Qualitative Test |
| 19(Stability and mechanical hazards) |
- |
7500 |
|
Cl. 19 : Stability and mechanical hazards |
| 20(Resistance to fire) |
- |
15000 |
|
Cl. 20 : Resistance to fire |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 2 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
-
|
124000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.5(Components) |
- |
2000 |
|
- |
| 1.6(Power interface .) |
- |
1000 |
|
- |
| 1.7(Markings and instructions) |
- |
3200 |
|
- |
| 2.1(Protection from electric shock and energy hazards) |
- |
8500 |
|
- |
| 2.2(SELV circuits) |
- |
4000 |
|
- |
| 2.3(TNV circuits) |
- |
3500 |
|
- |
| 2.4(Limited current circuits) |
- |
3500 |
|
- |
| 2.5(Limited power sources .) |
- |
4500 |
|
- |
| 2.6(Provisions for earthing and bonding) |
- |
3600 |
|
- |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
2000 |
|
- |
| 2.8(Safety interlocks) |
- |
2000 |
|
- |
| 2.9(Electrical insulation) |
- |
3000 |
|
- |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
22000 |
|
- |
| 3.1(General) |
- |
1000 |
|
- |
| 3.2(Connection to a mains supply) |
- |
2200 |
|
- |
| 3.3(Wiring terminals for connection of external conductors) |
- |
1000 |
|
- |
| 3.4(Disconnection from the mains supply) |
- |
1000 |
|
- |
| 3.5(Interconnection of equipment) |
- |
1000 |
|
- |
| 4.1(Stability) |
- |
3000 |
|
- |
| 4.2(Mechanical strength) |
- |
3600 |
|
- |
| 4.3(Design and construction) |
- |
2000 |
|
- |
| 4.4(Protection against hazardous moving parts) |
- |
2000 |
|
- |
| 4.5(Thermal requirements) |
- |
4000 |
|
- |
| 4.6(Openings in enclosures) |
- |
2000 |
|
- |
| 4.7(Resistance to fire) |
- |
2000 |
|
- |
| 5.1(Touch current and protective conductor curren) |
- |
8000 |
|
- |
| 5.2(Electric strength) |
- |
12500 |
|
- |
| 5.3(Abnormal operating and fault conditions) |
- |
10500 |
|
- |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
2000 |
|
- |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
2200 |
|
- |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
2000 |
|
- |
| 7.1(General) |
- |
1500 |
|
- |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
1700 |
|
- |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
1500 |
|
- |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
1500 |
|
- |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 3 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
LED BULB |
-
|
75000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
1000 |
|
N/A |
| 6(Interchangeability) |
- |
4000 |
|
N/A |
| 7(Protection against accidental contact with live parts) |
- |
12000 |
|
N/A |
| 8(Insulation Resistance and Electric Strength) |
- |
20000 |
|
N/A |
| 9(MECHANICAL STRENGTH) |
- |
15000 |
|
N/A |
| 10(cap temperature) |
- |
10000 |
|
N/A |
| 11(Resistance to Heat) |
- |
10000 |
|
N/A |
| 12(Resistance to Flame and Ignition) |
- |
5000 |
|
N/A |
| 14(Creepage distance and clearances) |
- |
1000 |
|
N/A |
| 13(Fault conditions) |
- |
2000 |
|
N/A |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 4 |
IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
Secondary Batteries and Cells (Lithium Systems) |
-
|
181000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
0 |
|
N/A |
| 5(General Safety Considerations) |
- |
0 |
|
N/A |
| 5.1(General) |
- |
0 |
|
N/A |
| 5.2(Insulation and Wiring) |
- |
5000 |
|
N/A |
| 5.3(Venting) |
- |
0 |
|
N/A |
| 5.4(Temperature, Voltage and Current Management) |
- |
0 |
|
N/A |
| 5.5(Terminal Contacts) |
- |
0 |
|
N/A |
| 5.6(Assembly of Cells into batteries) |
- |
0 |
|
N/A |
| 5.7(Quality Plan) |
- |
0 |
|
N/A |
| 5.8(Battery Safety Components) |
- |
0 |
|
N/A |
| 6(Tyoe Test amd Sample Size) |
- |
0 |
|
N/A |
| 7(Specific requirements and tests) |
- |
0 |
|
N/A |
| 7.1(Charging procedure for test purposes) |
- |
32000 |
|
Cl. 7.1.1 (18000 INR);
Cl.7.1.2 (14000 INR) |
| 7.2(Intended Use) |
- |
32000 |
|
Cl. 7.2.1 (22000 INR);
Cl.7.2.2 (10000 INR) |
| 7.3(Reasonably foreseeable misuse) |
- |
112000 |
|
Cl. 7.3.1 (15000 INR);
Cl.7.3.2 (14000 INR);
Cl.7.3.3 (7000 INR);
Cl.7.3.4 (11000 INR);
Cl.7.3.5 (11000 INR);
Cl.7.3.6 (13000 INR);
Cl.7.3.7 (12000 INR);
Cl.7.3.8.1 (17000 INR);
Cl.7.3.8.2 (12000 INR) |
| 8(Information for safety) |
- |
0 |
|
N/A |
| 8.1(General) |
- |
0 |
|
N/A |
| 8.2(Small Cell and battery safety information) |
- |
0 |
|
N/A |
| 9(Marking) |
- |
0 |
|
N/A |
| 9.1(Cell Marking) |
- |
0 |
|
N/A |
| 9.2(Battery Marking) |
- |
0 |
|
N/A |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
0 |
|
N/A |
| 9.4(Other information) |
- |
0 |
|
N/A |
| 10(Packaging) |
- |
0 |
|
N/A |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 5 |
IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
Secondary Cells and Batteries (Nickel Systems) |
-
|
164000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
0 |
|
N/A |
| 5(General Safety Considerations) |
- |
0 |
|
N/A |
| 5.1(General) |
- |
0 |
|
N/A |
| 5.2(Insulation and Wiring) |
- |
5000 |
|
IR Test |
| 5.3(Venting) |
- |
0 |
|
N/A |
| 5.4(Temperature, Voltage and Current Management) |
- |
0 |
|
N/A |
| 5.5(Terminal Contacts) |
- |
0 |
|
N/A |
| 5.6(Assembly of Cells into batteries) |
- |
0 |
|
N/A |
| 5.7(Quality Plan) |
- |
0 |
|
N/A |
| 6(Tyoe Test amd Sample Size) |
- |
0 |
|
N/A |
| 7(Specific requirements and tests) |
- |
0 |
|
N/A |
| 7.1(Charging procedure for test purposes) |
- |
19000 |
|
Charging and Discharging |
| 7.2(Intended Use) |
- |
48000 |
|
7.2.1(INR18000)
7.2.2(INR13000)
7.2.4(INR17000) |
| 7.3(Reasonably foreseeable misuse) |
- |
92000 |
|
7.3.1(INR7000)
7.3.2(INR14000)
7.3.3(INR7000)
7.3.4(INR11000)
7.3.5(INR9000)
7.3.6(INR10000)
7.3.7(INR12000)
7.3.8(INR14000)
7.3.9(INR8000) |
| 8(Information for safety) |
- |
0 |
|
N/A |
| 8.1(General) |
- |
0 |
|
N/A |
| 8.2(Small Cell and battery safety information) |
- |
0 |
|
N/A |
| 9(Marking) |
- |
0 |
|
N/A |
| 9.1(Cell Marking) |
- |
0 |
|
N/A |
| 9.2(Battery Marking) |
- |
0 |
|
N/A |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
0 |
|
N/A |
| 9.4(Other information) |
- |
0 |
|
N/A |
| 10(Packaging) |
- |
0 |
|
N/A |
|
Complete
|
|
31 Dec, 2023 |
- - |
| 6 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
CONTROLGEAR |
-
|
75000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
2000 |
|
N/A |
| 8(Protection against accidental contact with live parts) |
- |
8000 |
|
N/A |
| 9(Terminals) |
- |
5000 |
|
N/A |
| 10(PROVISION FOR EARTHING) |
- |
5000 |
|
N/A |
| 11(MOISTURE RESISTANCE) |
- |
10000 |
|
N/A |
| 12(Electric Strength) |
- |
5000 |
|
N/A |
| 16(Construction) |
- |
1000 |
|
N/A |
| 17(Creepage distance and clearances) |
- |
5000 |
|
N/A |
| 18(Screws, current carrying parts and connections) |
- |
3000 |
|
N/A |
| 19(Resistance to heat, fire and tracking) |
- |
10000 |
|
N/A |
| 20(Resistance to corrosion) |
- |
2000 |
|
N/A |
| 14(Fault conditions) |
- |
10000 |
|
N/A |
| 15(Transformer heating) |
- |
10000 |
|
N/A |
|
Complete
|
|
31 Dec, 2023 |
- - |