| 1 |
IS Testing |
IS Testing |
- |
-
|
1000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Testing clause 2(Testing clause 2 parameter) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- - |
| 2 |
IS 16333 : Part 3 (2017) |
Mobile phone handsets: Part 3 indian language support for mobile phone handsets - Specific requirements (First Revision) |
Mobile phone handsets Part 3 Indian language support |
-
|
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Inputting of text) |
- |
15000 |
|
- |
| 5.2(Message Readability) |
- |
15000 |
|
- |
|
Complete
|
|
- |
- - |
| 3 |
IS 16270 (2014) |
Secondary cells and batteries for solar photovoltaic application - General requirements and methods of test |
Storage Batteries |
-
|
740000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Condition of use) |
- |
0 |
|
- |
| 5.1(Mechanical Endurance) |
- |
0 |
|
- |
| 5.2(Charge efficiency) |
- |
0 |
|
- |
| 5.3(Deep discharge protection) |
- |
0 |
|
- |
| 5.4(Marking) |
- |
0 |
|
- |
| 5.5(Dafety) |
- |
0 |
|
- |
| 5.6(Documentation) |
- |
0 |
|
- |
| 6(Finctional Characteristics) |
- |
0 |
|
- |
| 7(General test conditions) |
- |
0 |
|
- |
| 8.1(Capacity test) |
- |
40000 |
|
- |
| 8.2(Endurance test) |
- |
200000 |
|
- |
| 8.3(Charge retention test) |
- |
60000 |
|
- |
| 8.4(Cycle endurance in Photovoltaic application) |
- |
250000 |
|
- |
| 8.5(Sulphation Test) |
- |
100000 |
|
- |
| 8.6(Water loss test) |
- |
75000 |
|
- |
| 8.7(Non spillability) |
- |
15000 |
|
- |
|
Complete
|
|
- |
- - |
| 4 |
IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
Lithium System Cells and Batteries |
-
|
34000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
0 |
|
- |
| 5(General Safety Considerations) |
- |
0 |
|
- |
| 5.1(General) |
- |
0 |
|
- |
| 5.2(Insulation and Wiring) |
- |
2000 |
|
- |
| 5.3(Venting) |
- |
0 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
0 |
|
- |
| 5.5(Terminal Contacts) |
- |
0 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
0 |
|
- |
| 5.7(Quality Plan) |
- |
0 |
|
- |
| 5.8(Battery Safety Components) |
- |
0 |
|
- |
| 6(Tyoe Test amd Sample Size) |
- |
2000 |
|
- |
| 7(Specific requirements and tests) |
- |
0 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
9000 |
|
- |
| 7.2(Intended Use) |
- |
8000 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
33000 |
|
- |
| 8(Information for safety) |
- |
0 |
|
- |
| 8.1(General) |
- |
0 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
0 |
|
- |
| 9(Marking) |
- |
0 |
|
- |
| 9.1(Cell Marking) |
- |
0 |
|
- |
| 9.2(Battery Marking) |
- |
0 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
0 |
|
- |
| 9.4(Other information) |
- |
0 |
|
- |
| 10(Packaging) |
- |
0 |
|
- |
|
Complete
|
|
- |
- - |
| 5 |
IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
Nickel System Cells And Batteries |
-
|
62000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
0 |
|
- |
| 5(General Safety Considerations) |
- |
0 |
|
- |
| 5.1(General) |
- |
0 |
|
- |
| 5.2(Insulation and Wiring) |
- |
2000 |
|
- |
| 5.3(Venting) |
- |
0 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
0 |
|
- |
| 5.5(Terminal Contacts) |
- |
0 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
0 |
|
- |
| 5.7(Quality Plan) |
- |
0 |
|
- |
| 6(Tyoe Test amd Sample Size) |
- |
0 |
|
- |
| 7(Specific requirements and tests) |
- |
0 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
10000 |
|
- |
| 7.2(Intended Use) |
- |
31000 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
24000 |
|
- |
| 8(Information for safety) |
- |
0 |
|
- |
| 8.1(General) |
- |
0 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
0 |
|
- |
| 9(Marking) |
- |
0 |
|
- |
| 9.1(Cell Marking) |
- |
0 |
|
- |
| 9.2(Battery Marking) |
- |
0 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
0 |
|
- |
| 9.4(Other information) |
- |
0 |
|
- |
| 10(Packaging) |
- |
0 |
|
- |
|
Complete
|
|
- |
- - |
| 6 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
INFORMATION TECHNOLOGY EQUIPMENT — SAFETY PART 1 |
-
|
70000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.3(Abnormal operating and fault conditions) |
- |
5000 |
|
- |
| 4.5(Thermal requirements) |
- |
2000 |
|
- |
| 1.6(Power interface .) |
- |
3000 |
|
- |
| 2.2(SELV circuits) |
- |
2000 |
|
- |
| 1.7(Markings and instructions) |
- |
1000 |
|
- |
| 2.1(Protection from electric shock and energy hazards) |
- |
2000 |
|
- |
| 2.3(TNV circuits) |
- |
2000 |
|
- |
| 2.5(Limited power sources .) |
- |
2000 |
|
- |
| 2.6(Provisions for earthing and bonding) |
- |
2000 |
|
- |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
2000 |
|
- |
| 2.8(Safety interlocks) |
- |
2000 |
|
- |
| 2.9(Electrical insulation) |
- |
2000 |
|
- |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
4000 |
|
- |
| 3.1(General) |
- |
0 |
|
- |
| 3.2(Connection to a mains supply) |
- |
2000 |
|
- |
| 3.3(Wiring terminals for connection of external conductors) |
- |
2000 |
|
- |
| 3.4(Disconnection from the mains supply) |
- |
2000 |
|
- |
| 3.5(Interconnection of equipment) |
- |
2000 |
|
- |
| 4.1(Stability) |
- |
2000 |
|
- |
| 4.2(Mechanical strength) |
- |
2000 |
|
- |
| 4.3(Design and construction) |
- |
2000 |
|
- |
| 4.4(Protection against hazardous moving parts) |
- |
2000 |
|
- |
| 4.6(Openings in enclosures) |
- |
3000 |
|
- |
| 4.7(Resistance to fire) |
- |
2000 |
|
- |
| 5.1(Touch current and protective conductor curren) |
- |
2000 |
|
- |
| 5.2(Electric strength) |
- |
3000 |
|
- |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
1000 |
|
- |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
3000 |
|
- |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
1000 |
|
- |
| 7.1(General) |
- |
0 |
|
- |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
2000 |
|
- |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
2000 |
|
- |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
2000 |
|
- |
| 1.5(Components) |
- |
0 |
|
- |
| 2.4(Limited current circuits) |
- |
2000 |
|
- |
| 2.8.2/2.8.5(Interlock switches) |
- |
0 |
|
- |
| 2.8.7(Switches and Relay) |
- |
0 |
|
- |
| 2.10.4.2(Material Group and Comparative Tracking Index) |
- |
0 |
|
- |
| 2.10.5.3(Insulating Compound as Solid Insulation) |
- |
0 |
|
- |
| 2.10.5.4(Opto-coupler) |
- |
0 |
|
- |
| 2.10.5.6(Thin sheet materials) |
- |
0 |
|
- |
| 2.10.5.11(SMPS Transformer and Inductor) |
- |
0 |
|
- |
| 2.10.5.12(Wires in wound components) |
- |
0 |
|
- |
| 2.10.5.13(Winding wire) |
- |
0 |
|
- |
| 2.10.5.14(Additional insulation in wound components) |
- |
0 |
|
- |
| 2.10.6(PCB material) |
- |
0 |
|
- |
| 2.10.8.2(Thermal conditioning (thermal ageing)) |
- |
0 |
|
- |
| 2.10.8.4(Abrasion resistance test) |
- |
0 |
|
- |
| 2.10.9(Thermal Cycling) |
- |
0 |
|
- |
| 2.10.10(Test for Pollution Degree 1 environment and for insulating compound) |
- |
0 |
|
- |
| 2.10.11(Tests for semiconductor devices and for cemented joints) |
- |
0 |
|
- |
| 2.10.12(Enclosed and sealed parts) |
- |
0 |
|
- |
| 3.1.4(Internal wire) |
- |
0 |
|
- |
| 3.2.4(Appliance inlet /connector) |
- |
0 |
|
- |
| 3.2.5(Non re-wirable plug with PVC sheathed cable) |
- |
0 |
|
- |
| 4.2.8(Cathode Ray Tubes) |
- |
0 |
|
- |
| 4.3.8(Batteries) |
- |
0 |
|
- |
| 4.3.10(Dust, powders, liquids and gases) |
- |
0 |
|
- |
| 4.3.11(Containers for liquids or gases) |
- |
0 |
|
- |
| 4.3.12(Flammable liquids) |
- |
0 |
|
- |
| Annex A3(Hot flaming oil test) |
- |
0 |
|
- |
| Annex CC(Evaluation of integrated circuit (IC) current limiters) |
- |
0 |
|
- |
| Annex K(Thermal Control) |
- |
0 |
|
- |
| Annex Q(Voltage Dependent Resistors) |
- |
0 |
|
- |
| Annex B(Motor tests under abnormal conditions) |
- |
0 |
|
- |
| Annex C(Transformers) |
- |
0 |
|
- |
| Annex DD(Requirements for the mounting means of a rack mounted equipment) |
- |
0 |
|
- |
| Annex EE(Household and home/ office document/ media shredders) |
- |
0 |
|
- |
|
Complete
|
|
- |
- - |
| 7 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
SELF-BALLASTED LED LAMPS FOR GENERAL LIGHTING SERVICES |
-
|
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
0 |
|
- |
| 6(Interchangeability) |
- |
2500 |
|
- |
| 7(Protection against accidental contact with live parts) |
- |
4500 |
|
- |
| 8(Insulation Resistance and Electric Strength) |
- |
2500 |
|
- |
| 9(MECHANICAL STRENGTH) |
- |
3000 |
|
- |
| 10(cap temperature) |
- |
4000 |
|
- |
| 11(Resistance to Heat) |
- |
4000 |
|
- |
| 12(Resistance to Flame and Ignition) |
- |
4000 |
|
- |
| 13(Fault conditions) |
- |
4500 |
|
- |
| 14(Creepage distance and clearances) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- - |
| 8 |
IS/IEC 61730 : PART 2 (2004) |
Photovoltaic (PV) Module Safety Qualification Part 2 Requirements for Testing |
PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION |
-
|
1000000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1(Visual Inspection (MST 01)) |
- |
18518 |
|
- |
| 10.2(Accessibility test (MST 11)) |
- |
18518 |
|
- |
| 10.3(Cut susceptibility test (MST 12)) |
- |
18518 |
|
- |
| 10.4(Ground Continuity Test (MST 13)) |
- |
18518 |
|
- |
| 10.5(Impulse voltage test (MST 14)) |
- |
18518 |
|
- |
| 10.6(Dielectric withstand test (MST 16)) |
- |
18518 |
|
- |
| 10.7(Temperature test (MST 21)) |
- |
18518 |
|
- |
| 10.8(Fire test (MST 23)) |
- |
18518 |
|
- |
| 10.9(Reverse Current overload test (MST 26)) |
- |
18518 |
|
- |
| 10.10(Module breakage test (MST 32)) |
- |
18518 |
|
- |
| 11.1(Partial discharge-test (MST 15)) |
- |
18518 |
|
- |
| 11.2(Conduit Bending test (MST 33)) |
- |
18518 |
|
- |
| 11.3(Terminal box knockout tests (MST 44)) |
- |
18518 |
|
- |
| Cl.5, Table 7(Thermal cycling (T200) (MST 51)) |
- |
18518 |
|
- |
| Cl.5, Table 7(Thermal cycling (T50) (MST 51)) |
- |
18518 |
|
- |
| Cl.5, Table 7(Humidity freeze (10HF) (MST 52)) |
- |
18518 |
|
- |
| Cl.5, Table 7(Damp heat (DH1000) (MST 53)) |
- |
18518 |
|
- |
| Cl.5, Table 7(UV resistance (MST 54)) |
- |
18518 |
|
- |
| Cl.5, Table 7(Wet leakage current test (MST 17)) |
- |
18518 |
|
- |
| Cl.5, Table 7(Robustness of termination test (MST 42)) |
- |
18518 |
|
- |
| Cl.5, Table 7(Hot spot test (MST 22)) |
- |
18518 |
|
- |
| Cl.5, Table 7(Mechanical load test (MST 34)) |
- |
18518 |
|
- |
| 10.33 IS/IEC 61730-2(Dry heat conditioning MST 56) |
- |
18518 |
|
- |
| 10.32 IS/IEC 61730-2(Cold conditioning MST 55) |
- |
18518 |
|
- |
| 10.31 IS/IEC 61730-2(UV test MST 54) |
- |
18518 |
|
- |
| 10.30 IS/IEC 61730-2(Damp heat test MST 53) |
- |
18518 |
|
- |
| 10.29 IS/IEC 61730-2(Humidity-freeze test MST 52) |
- |
18518 |
|
- |
| 10.28 IS/IEC 61730-2(Thermal cycling test MST 51) |
- |
18518 |
|
- |
| 10.27 IS/IEC 61730-2(Robutness of terminations test MST 42) |
- |
18518 |
|
- |
| 10.26 IS/IEC 61730-2(Materials creep test MST 37) |
- |
18518 |
|
- |
| 10.25 IS/IEC 61730-2(Lap shear strength test MST 36) |
- |
18518 |
|
- |
| 10.24 IS/IEC 61730-2(Peel test MST 35) |
- |
18518 |
|
- |
| 10.23 IS/IEC 61730-2(Static Mechanical load test MST 34) |
- |
18518 |
|
- |
| 10.22 IS/IEC 61730-2(Screw connections test MST 33) |
- |
18518 |
|
- |
| 10.21 IS/IEC 61730-2(Module breakage test MST 32) |
- |
18518 |
|
- |
| 10.20 IS/IEC 61730-2(Reverse current overload test MST 25) |
- |
18518 |
|
- |
| 10.19 IS/IEC 61730-2(Bypass diode thermal test MST 25) |
- |
18518 |
|
- |
| 10.18 IS/IEC 61730-2(Ignitability test MST 24) |
- |
18518 |
|
- |
| 10.17 IS/IEC 61730-2(Fire test MST 23) |
- |
18518 |
|
- |
| 10.16 IS/IEC 61730-2(Hot-spot endurance test MST 22) |
- |
18518 |
|
- |
| 10.15 IS/IEC 61730-2(Temperature test MST 21) |
- |
18518 |
|
- |
| 10.14 IS/IEC 61730-2(Wet leakage current test MST 17) |
- |
18518 |
|
- |
| 10.13 IS/IEC 61730-2(Insulation test MST 16) |
- |
18518 |
|
- |
| 10.12 IS/IEC 61730-2(Impulse voltage test MST 14) |
- |
18518 |
|
- |
| 10.11 IS/IEC 61730-2(Continuity test of equipotential bonding MST 13) |
- |
18518 |
|
- |
| 10.10 IS/IEC 61730-2(Cut susceptibility test MST 12) |
- |
18518 |
|
- |
| 10.9 IS/IEC 61730-2(Accessibility test MST 11) |
- |
18518 |
|
- |
| 10.8 IS/IEC 61730-2(Bypass diode functionality test MST 07) |
- |
18518 |
|
- |
| 10.7 IS/IEC 61730-2(Sharp edge test MST 06) |
- |
18518 |
|
- |
| 10.6 IS/IEC 61730-2(Durability of marking MST 05) |
- |
18518 |
|
- |
| 10.5 IS/IEC 61730-2(Insulation thickness test MST 04) |
- |
18518 |
|
- |
| 10.4 IS/IEC 61730-2(Maximum power determination MST 03) |
- |
18518 |
|
- |
| 10.3 IS/IEC 61730-2(Performance at STC MST 02) |
- |
18518 |
|
- |
| 10.2 IS/IEC 61730-2(Visual inspection MST01) |
- |
18546 |
|
- |
|
Complete
|
|
- |
- - |
| 9 |
IS/IEC 61730 : PART 1 (2004) |
Photovoltaic (PV) Module Safety Qualification Part 1 Requirements for Construction |
PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION |
-
|
200000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Application classes) |
- |
20000 |
|
- |
| 4(Construction requirements) |
- |
20000 |
|
- |
| 5(Polymeric materials) |
- |
20000 |
|
- |
| 6(Internal wiring and current-carrying parts) |
- |
20000 |
|
- |
| 7(Connections) |
- |
20000 |
|
- |
| 8(Bonding and grounding) |
- |
20000 |
|
- |
| 9(Creepage and clearance distances) |
- |
20000 |
|
- |
| 10(Field wiring compartments with covers) |
- |
20000 |
|
- |
| 11(Marking) |
- |
20000 |
|
- |
| 12() |
- |
20000 |
|
- |
|
Complete
|
|
- |
- - |
| 10 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
SAFETY OF LAMP CONTROLGEAR |
-
|
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
1500.02 |
|
ok |
| 8(Protection against accidental contact with live parts) |
- |
2666.66 |
|
ok |
| 9(Terminals) |
- |
3166.66 |
|
ok |
| 10(PROVISION FOR EARTHING) |
- |
1500 |
|
ok |
| 11(MOISTURE RESISTANCE) |
- |
2500 |
|
ok |
| 12(Electric Strength) |
- |
2500 |
|
ok |
| 13(Thermal endurance test for winding of ballasts) |
- |
1000 |
|
ok |
| 14(Fault conditions) |
- |
1000 |
|
ok |
| 15(Transformer heating) |
- |
2500 |
|
ok |
| 16(Construction) |
- |
3166.66 |
|
ok |
| 17(Creepage distance and clearances) |
- |
1000 |
|
ok |
| 18(Screws, current carrying parts and connections) |
- |
1500 |
|
ok |
| 19(Resistance to heat, fire and tracking) |
- |
4000 |
|
ok |
| 20(Resistance to corrosion) |
- |
2000 |
|
ok |
|
Complete
|
|
- |
- - |
| 11 |
IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
Uninterruptible Power Systems (UPS) |
-
|
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
0 |
|
- |
| 4.6(Power interface) |
- |
3000 |
|
- |
| 4.7(Marking & instructions) |
- |
1000 |
|
- |
| 5.1(Protection against shock and energy hazards) |
- |
1500 |
|
- |
| 5.2(Requirement of auxiliary circuits) |
- |
1000 |
|
- |
| 5.3(Protective earthing and bonding) |
- |
1500 |
|
- |
| 5.4(AC and DC power isolation) |
- |
2000 |
|
- |
| 5.5(Over current and earth fault condition) |
- |
2000 |
|
- |
| 5.6(Safety interlocks) |
- |
5000 |
|
- |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
2000 |
|
- |
| 6.1(Wiring, connections and supply) |
- |
1000 |
|
- |
| 6.2(Connection to power) |
- |
2000 |
|
- |
| 6.3(Wiring terminals for external power conductors) |
- |
2000 |
|
- |
| 7.1(Enclosure) |
- |
2000 |
|
- |
| 7.2(STABILITY) |
- |
2500 |
|
- |
| 7.3(MECHANICAL STRENGTH) |
- |
2000 |
|
- |
| 7.4(Construction details) |
- |
2000 |
|
- |
| 7.5(Resistance to fire) |
- |
3000 |
|
- |
| 7.6(Battery location) |
- |
1500 |
|
- |
| 7.7(Temperature rise) |
- |
3000 |
|
- |
| 8.1(General procision for earth leakage) |
- |
2000 |
|
- |
| 8.2(Electric Strength) |
- |
2000 |
|
- |
| 8.3(Abnormal operating and fault conditions) |
- |
3000 |
|
- |
| 9.0(Connection to telecommunication networks) |
- |
3000 |
|
- |
|
Complete
|
|
- |
- - |
| 12 |
IS 14286 (2010) |
Crystalline silicon terrestrial photovoltaic (PV) modules - Design qualification and type approval (First Revision) |
- |
-
|
740000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Marking) |
- |
39333.33 |
|
- |
| 10.1(Visual inspection) |
- |
39333.33 |
|
- |
| 10.2(Maximum power determination) |
- |
39333.33 |
|
- |
| 10.3(Insulation test) |
- |
39333.33 |
|
- |
| 10.4(Measurement of temperature coefficients) |
- |
39333.33 |
|
- |
| 10.5(Measurement of NOCT) |
- |
39333.33 |
|
- |
| 10.6(Performance at STC and NOCT) |
- |
39333.33 |
|
- |
| 10.7(Performance at low irradiance) |
- |
39333.33 |
|
- |
| 10.8(Outdoor exposure test) |
- |
39333.33 |
|
- |
| 10.9(Hot-spot endurance test) |
- |
39333.33 |
|
- |
| 10.10(UV preconditioning) |
- |
39333.33 |
|
- |
| 10.11(Thermal cycling test) |
- |
36888.90 |
|
- |
| 10.12(Humidity freeze test) |
- |
36888.90 |
|
- |
| 10.13(Damp heat test) |
- |
36888.92 |
|
- |
| 10.14(Robustness of termination test) |
- |
39333.33 |
|
- |
| 10.15(Wet leakage current test) |
- |
39333.33 |
|
- |
| 10.16(Mechanical load test) |
- |
39333.33 |
|
- |
| 10.17(Hail test) |
- |
39333.33 |
|
- |
| 10.18(Bypass diode thermal' test) |
- |
39333.33 |
|
- |
|
Complete
|
|
- |
- - |
| 13 |
IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
Audio, Video and Similar Electronic Apparatus — Safety |
-
|
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking and instructions) |
- |
0 |
|
- |
| 6(Hazardous radiations) |
- |
0 |
|
- |
| 7(Heating under normal operating conditions) |
- |
7000 |
|
- |
| 8(Constructional requirements with regard to the protection against electric shock) |
- |
6000 |
|
- |
| 9(Electric shock hazard under normal operating conditions) |
- |
5000 |
|
- |
| 10(Insulation requirements) |
- |
11000 |
|
- |
| 11(Fault conditions) |
- |
0 |
|
- |
| 12(Mechanical strength) |
- |
8000 |
|
- |
| 13(CLEARANCES and CREEPAGE DISTANCES) |
- |
3000 |
|
- |
| 14(Components) |
- |
0 |
|
- |
| 15(TERMINALS) |
- |
0 |
|
- |
| 16(External flexible cords) |
- |
0 |
|
- |
| 17(Electrical connections and mechanical fixings) |
- |
0 |
|
- |
| 18(Mechanical strength of picture tubes and protection against the effects of implosion) |
- |
0 |
|
- |
| 19(Stability and mechanical hazards) |
- |
0 |
|
- |
| 20(Resistance to fire) |
- |
0 |
|
- |
|
Complete
|
|
- |
- - |