| 31 |
IS 7224 (2006) |
Iodized salt, vacuum evaporated iodized salt and refined iodized salt - Specification (Second Revision) |
- |
-
|
- View breakup
Rs.7500/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
18 Dec, 2021 |
- - |
| 32 |
IS 15647 (2006) |
Hot rolled steel narrow width strip for welded tubes and pipes |
All |
-
|
11000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8(UTM) |
- |
3000 |
|
Tensile |
| Cl 9(Press) |
- |
1000 |
|
Bend |
| Cl 11(Workmanship) |
- |
500 |
|
Freedom From Defects |
| Cl 12(Length, Width & Thickness) |
- |
500 |
|
Dimesions |
| Cl 13(Workmanship) |
- |
500 |
|
Freedom from Defects |
| Cl. 12(Weight) |
- |
500 |
|
Weight |
| Cl. 12(Edge Camber) |
- |
500 |
|
Dimension |
| Cl. 12(Thickness) |
- |
500 |
|
Dimension |
| Cl. 8.2 Table 3(Elongation) |
- |
3000 |
|
Elonagtion |
| Cl. 8.2 Table 3(Yield Stress) |
- |
3000 |
|
Yield |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 33 |
IS 15658 (2006) |
Precast concrete blocks for paving - Specification |
All |
-
|
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.2.1 & 7.1(VISUAL INSPECTION) |
- |
500 |
|
Visual |
| B-1.3.1(MEAN INDIVIDUAL WIDTH (of all eight test specimens), W) |
- |
3000 |
|
All Dimensions |
| B-5(AVERAGE WIDTH (Average for eight test specimens), W) |
- |
3000 |
|
All Dimensions |
| B-1.3.1(MEAN INDIVIDUAL LENGTH (of all eight test specimens), L) |
- |
3000 |
|
All Dimensions |
| B-5(AVERAGE LENGTH (Average for eight test specimens), L) |
- |
3000 |
|
All Dimensions |
| Table 1(MINIMUM PAVER BLOCK THICKNESS) |
- |
3000 |
|
All Dimensions |
| B-1.3.2(MEAN INDIVIDUAL THICKNESS (of all eight test specimens), T) |
- |
3000 |
|
All Dimensions |
| B-5(AVERAGE THICKNESS (Average for eight test specimens), T) |
- |
3000 |
|
All Dimensions |
| B-1.3.3(INDIVIDUAL ASPECT RATIO (L/T) (of all eight test specimens)) |
- |
3000 |
|
All Dimensions |
| B-5(AVERAGE ASPECT RATIO (L/T) (for eight test specimens)) |
- |
3000 |
|
All Dimensions |
| B-2.3(INDIVIDUAL ARRIS/CHAMFER (of all eight test specimens)) |
- |
3000 |
|
All Dimensions |
| B-5(AVERAGE ARRIS/CHAMFER (for eight test specimens)) |
- |
3000 |
|
All Dimensions |
| B-5(INDIVIDUAL PLAN AREA, ASP (of all eight test specimens) ) |
- |
3000 |
|
All Dimensions |
| B-5(AVERAGE PLAN AREA, ASP (for eight test specimens)) |
- |
3000 |
|
All Dimensions |
| B-5(INDIVIDUAL WEARING FACE AREA, Asw (of all eight test specimens)) |
- |
3000 |
|
All Dimensions |
| B-5(AVERAGE WEARING FACE AREA, Asw (for eight test specimens)) |
- |
3000 |
|
All Dimensions |
| B- 4.3(MEAN INDIVIDUAL SQUARENESS (of all eight test specimens) ) |
- |
3000 |
|
All Dimensions |
| B-5(AVERAGE SQUARENESS (for eight test specimens)) |
- |
3000 |
|
All Dimensions |
| 6.2.3(THICKNESS OF WEARING LAYER, if the sample is Double Layered (for eight test specimens)) |
- |
3000 |
|
All Dimensions |
| 6.2.4(WATER ABSORPTION TEST (Average for three test specimens)) |
- |
3000 |
|
Water Absorption |
| 6.2.5(AVERAGE COMPRESSIVE STRENGTH (Average for eight test specimens) ) |
- |
5000 |
|
Compressive Strength |
| 6.2.5.1(INDIVIDUAL COMPRESSIVE STRENGTH (Individual strength of eight test specimen)) |
- |
5000 |
|
Compressive Strength |
| 6.2.6(ABRASION RESISTANCE, Dry Condition (For all eight test specimens)) |
- |
5000 |
|
Abrasion Resistance |
| 6.2.6(ABRASION RESISTANCE, Wet Condition (For all eight test specimens)) |
- |
5000 |
|
Abrasion Resistance |
| 6.2.7(INDIVIDUAL TENSILE SPLITTING STRENGTH (Individual strength of eight test specimen )) |
- |
5000 |
|
Tensile Splitting |
| 6.2.7(AVERAGE TENSILE SPLITTING STRENGTH (for eight test specimen )) |
- |
5000 |
|
Tensile Splitting |
| Annex-G-7(INDIVIDUAL BREAKING LOAD (Individual Load of eight test specimen )) |
- |
5000 |
|
Flexural |
| 6.2.8(INDIVIDUAL FLEXURAL STRENGTH (Individual strength of eight test specimen )) |
- |
5000 |
|
Flexural |
| 6.2.8(AVERAGE FLEXURAL STRENGTH (Average strength of eight test specimen )) |
- |
5000 |
|
Flexural |
| Annex-G-7(AVERAGE BREAKING LOAD) |
- |
5000 |
|
Flexural |
| Annex G-7(INDIVIDUAL FAILURE LOAD/UNIT LENGTH (Individual Failure Load of eight test specimen )) |
- |
5000 |
|
Tensile Splitting |
| 6.1.2(Physical requirement) |
- |
500 |
|
- |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 34 |
IS 4457 (2007) |
Ceramic unglazed vitreous acid resisting tiles - Specification (Second Revision) |
All |
-
|
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 5, Table 1 - iv -a (Resistance to Chemicals - Annex F) |
- |
10000 |
|
Resistance to Chemicals |
| Cl. 5, Table 1 - iv -b (Resistance to conc. HNO3 and conc. H2SO4 - Annex G) |
- |
10000 |
|
Resistance to conc. HNO3 and conc. H2SO4 |
| 4.1(DIMENSIONS AND TOLERANCES- Size) |
- |
10000 |
|
All Dimensions |
| 4.2(DIMENSIONS AND TOLERANCES- Thickness) |
- |
10000 |
|
All Dimensions |
| 5-Table 1(i)-a(REQUIREMENTS-Dimensions and Surface Quality-Length) |
- |
11000 |
|
All Dimensions and Surface Quality |
| 5-Table 1(i)-a(REQUIREMENTS-Dimensions and Surface Quality-Width) |
- |
11000 |
|
All Dimensions and Surface Quality |
| 5-Table 1(i)-b(REQUIREMENTS-Dimensions and Surface Quality-Thickness) |
- |
11000 |
|
All Dimensions and Surface Quality |
| 5-Table 1(i)-c(REQUIREMENTS-Dimensions and Surface Quality-Straightness of sided) |
- |
11000 |
|
All Dimensions |
| 5-Table 1(i)-d(REQUIREMENTS-Dimensions and Surface Quality-Rectangularity) |
- |
10000 |
|
All Dimensions |
| 5-Table 1(i)-e(REQUIREMENTS-Dimensions and Surface Quality-Surface flatness-Centre curvature) |
- |
11000 |
|
All Dimensions and Surface Quality |
| 5-Table 1(i)-e(REQUIREMENTS-Dimensions and Surface Quality-Surface flatness-Edge curvature) |
- |
11000 |
|
All Dimensions and Surface Quality |
| 5-Table 1(i)-e(REQUIREMENTS-Dimensions and Surface Quality-Surface flatness-Warpage) |
- |
11000 |
|
All Dimensions and Surface Quality |
| 5-Table 1(ii)(REQUIREMENTS-Surface Quality) |
- |
1000 |
|
Surface Quality |
| 5-Table 1(iii)(REQUIREMENTS-Physical Properties-Water absorption by weigh(Average)) |
- |
10000 |
|
Water Absorption |
| 5-Table 1(iii)-a(REQUIREMENTS-Physical Properties-Water absorption by weigh(Indivisual)) |
- |
10000 |
|
Water Absorption |
| 5-Table 1(iii)-b-1(REQUIREMENTS-Physical Properties-Breaking strengrh(Thickness>=7.5mm)) |
- |
15000 |
|
Modulus of Rupture and Breaking Strength |
| 5-Table 1(iii)b-2(REQUIREMENTS-Physical Properties-Breaking strengrh(Thickness <7.5mm)) |
- |
15000 |
|
Modulus of Rupture and Breaking Strength |
| 5-Table 1(iii)-c(REQUIREMENTS-Physical Properties-Modulus of rupture(Average)) |
- |
15000 |
|
Modulus of Rupture and Breaking Strength |
| 5-Table 1(iii)-c(REQUIREMENTS-Physical Properties-Modulus of rupture(Individual)) |
- |
15000 |
|
Modulus of Rupture and Breaking Strength |
| 5-Table 1(iii)-d(REQUIREMENTS-Physical Properties-Abrusion resistance) |
- |
5000 |
|
Abrasion |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 35 |
IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
-
|
52500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
3000 |
|
- |
| 10.1(Power input) |
- |
3000 |
|
- |
| 10.2(Current input) |
- |
3000 |
|
- |
| 11.1(General) |
- |
1000 |
|
- |
| 11.2(General) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
6000 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
5000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
6000 |
|
- |
| 14(Transient Over Voltages) |
- |
8000 |
|
- |
| 15.0(General) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
10000 |
|
- |
| 15.2(Spillage Test) |
- |
3000 |
|
- |
| 15.3(Humidity Test) |
- |
5000 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
5000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
6000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
6000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
8000 |
|
- |
| 20(Stability test) |
- |
2000 |
|
- |
| 21(Mechanical Strength Test) |
- |
5000 |
|
- |
| 22(Construction verification related test) |
- |
8000 |
|
- |
| 23(General) |
- |
2500 |
|
- |
| 24(Components) |
- |
2000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
7000 |
|
- |
| 26(Terminals for external conductors) |
- |
3000 |
|
- |
| 27(Provision for earthing) |
- |
3000 |
|
- |
| 28(Screw test and connections) |
- |
5000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
9000 |
|
- |
| 30.1(Ball pressure test) |
- |
3000 |
|
- |
| 30.2(Glow Wire Test) |
- |
3000 |
|
- |
| 30.2(Needle Flame Test) |
- |
3000 |
|
- |
| 31(Resistance to Rusting) |
- |
2000 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
2000 |
|
- |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 36 |
IS 6240 (2008) |
Hot rolled steel plate (Up To 6 Mm) sheet and strip for the manufacture of low pressure liquefiable gas cylinders (Fourth Revision) |
All |
-
|
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7(UTM) |
- |
3000 |
|
Tensile |
| Cl 8(Press) |
- |
1000 |
|
Bend |
| Cl 9(Strainage Embrittlement) |
- |
5000 |
|
Strainage Embrrittlement |
| Cl 10(Erichsen Cupping) |
- |
3000 |
|
Cupping |
| Cl 13(Length, Width & Thickness) |
- |
1000 |
|
Dimension |
| 6.1(Carbon %) |
- |
500 |
|
Carbon |
| 6.1(Manganese %) |
- |
500 |
|
Manganese |
| 6.1(Phosphorus %) |
- |
500 |
|
Phosphorous |
| 6.1(Sulphur %) |
- |
500 |
|
Sulphur |
| 6.1(Silicon %) |
- |
500 |
|
Silicon |
| 6.1( Aluminium %) |
- |
500 |
|
Aluminium |
| 6.1(Nitrogen%) |
- |
1500 |
|
Nitrogen |
| Cl. 13(Out of square) |
- |
1000 |
|
Dimension |
| Cl. 13(Flatness) |
- |
1000 |
|
Dimension |
| Cl. 13(Camber) |
- |
1000 |
|
Dimension |
| Cl. 13(Width) |
- |
1000 |
|
Dimension |
| Cl. 13(Thickness) |
- |
1000 |
|
Dimension |
| Cl. 12(Freedom from defects) |
- |
1000 |
|
Freedom from Defect |
| Cl. 7.2 Table 3(Elongation) |
- |
3000 |
|
Elongation |
| Cl. 7.2 Table 3(Yield Stress) |
- |
3000 |
|
Elongation |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 37 |
IS 13488 (2008) |
Irrigation equipment - Emitting pipe systems - Specification (First Revision) |
NA |
-
|
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.2 (Ref. Cl 4.1.b of IS 12786 : 1989)(Potyethylene - anti-oxidant) |
- |
1500 |
|
OK |
| 5.1.2 (Ref. Cl 4.1.c.i of IS 12786 : 1989)(Density) |
- |
1000 |
|
OK |
| 5.1.2 (Ref. Cl 4.1.c.ii of IS 12786 : 1989)(Toluene extract - Annex A of IS 12786:1989) |
- |
1500 |
|
OK |
| 5.1.2 (Ref. Cl 4.1.c.iii of IS 12786 : 1989)(Volatile matter - Annex B of IS 12786:1989) |
- |
1000 |
|
OK |
| 5.1.2 (Ref. Cl 4.1.c & 4.2.a of IS 12786 : 1989)(Carbon Black content - IS 2530 : 1963) |
- |
1500 |
|
OK |
| 8.1.2(Uniformity of Emission Rate for Unregulated Emitting Pipes) |
- |
5000 |
|
OK |
| 8.1.3(Uniformity of Emission Rate for Regulated Emitting Pipes) |
- |
5000 |
|
OK |
| 8.2(Emission Rate of Emitting Unit as a Function of Inlet Pressure) |
- |
5000 |
|
OK |
| 8.2.1(Unregu/Qt~d Emining Pipe) |
- |
5000 |
|
OK |
| 8.2.2(Regulated Emitting Pipes) |
- |
5000 |
|
OK |
| 8.3.1(Wall Thickness ofEmitting Pipe) |
- |
1000 |
|
OK |
| 8.3.2(Inside Diameter ofEmitting Pipe) |
- |
1000 |
|
OK |
| 8.3.3(Flow Paths in Emitting Unit) |
- |
1000 |
|
OK |
| 8.3.4(Spacing ofEmitter Units) |
- |
1000 |
|
OK |
| 8.4.1(Resistance to Hydrostatic Pressure at Ambient Temperature) |
- |
5000 |
|
OK |
| 8.4.2(Resistance to Hydrostatic Pressure at Elevated Temperature) |
- |
5000 |
|
OK |
| 8.5(Resistance to Tension at Elevated Temperature) |
- |
5000 |
|
OK |
| 8.5(Resistance to Tension at Elevated Temperature) |
- |
5000 |
|
OK |
| 8.5(Resistance to Tension at Elevated Temperature) |
- |
5000 |
|
OK |
| 8.6(Resistance to Pull Out of Joints Between Fitting and Emitting
IS 13479) |
- |
2000 |
|
OK |
| 8.7.1(Resistance of PE Emitting Pipe to
Environmental Stress Cracking -Acceptance Test
Annex D of IS 12786) |
- |
5000 |
|
OK |
| 8.7.2(Resistance of PE Emitting Pipe to
Environmental Stress Cracking - Type Test
Annex D of IS 12786) |
- |
5000 |
|
OK |
| 8.8(Determination of Emitting Unit Exponent) |
- |
3000 |
|
OK |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 38 |
IS 15801 (2008) |
Polypropylene - Random copolymer pipes for hot and cold water supplies - Specification |
NA |
-
|
150000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7(Dimensions Of Pipes) |
- |
3000 |
|
ok |
| Cl 8(Visual Appearance) |
- |
500 |
|
ok |
| Cl 9.1(Hydraulic Characteristics) |
- |
15000 |
|
ok |
| Cl 9.2(Fusion Compatibility) |
- |
2000 |
|
ok |
| Cl 9.3(Reversion Test ) |
- |
5000 |
|
ok |
| Cl 9.4 & Annex B(Impact Strength) |
- |
5000 |
|
ok |
| Cl 9.5(Density) |
- |
1000 |
|
ok |
| Cl 9.6(Melt Flow Rate) |
- |
2000 |
|
ok |
| Cl 9.7(Carbon Black Content & Dispersion) |
- |
2000 |
|
ok |
| Cl 9.8(Thermal Stability By Hydrostatic Pressure Testing) |
- |
125000 |
|
ok |
| Cl 9.9(Opacity) |
- |
2000 |
|
ok |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 39 |
IS 278 (2009) |
Galvanized steel barbed wire for fencing - Specification (Fourth Revision) |
All |
-
|
6500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 Table-1(Sizes Diameter of Line wire) |
- |
1000 |
|
Dimension |
| 5 Table-1(Sizes Diamater of Point wire) |
- |
1000 |
|
Dimension |
| 5 Table-1(Sizes Mass of Completed barbed wire) |
- |
1000 |
|
Mass |
| 5 Table-1(Sizes Distance between two barbs) |
- |
1000 |
|
Dimension |
| 5 Table-1(Sizes No. of Lays between the two consequtive barbs) |
- |
1000 |
|
Dimension |
| 9.1(Freedom from defects) |
- |
1000 |
|
Freedom from Defects |
| 12.1(Tensile Strength) |
- |
1500 |
|
Tensile Test |
| 12.1(Breaking load) |
- |
1500 |
|
Breaking Load |
| 12.3(Ductility) |
- |
1500 |
|
Wrapping |
| 12.2.1(Mass of zinc coating (line wire)) |
- |
1500 |
|
Mass of Zinc Coating |
| 12.2.2(Mass of zinc coating (point wire)) |
- |
1500 |
|
Uniformity of Zinc Coating |
| Cl. 7.1(General) |
- |
1000 |
|
General |
| Cl. 7.2(Finishing of Barbs) |
- |
1000 |
|
Finishing of Barbs |
| Cl. 7.2(Length of Barbs) |
- |
1000 |
|
Dimension |
| Cl. 7.2(Cut Angle) |
- |
1000 |
|
Dimension |
| 4(Type A/Type B) |
- |
1000 |
|
Type A/Type B |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 40 |
IS 3502 (2009) |
Steel chequered plates (Third Revision) |
All |
-
|
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5(Workmanship) |
- |
1000 |
|
Freedom from Defects |
| Cl 8(UTM) |
- |
7500 |
|
Tensile Test |
| Cl 9(Press) |
- |
1000 |
|
Bend Test |
| Cl 10(Length, Width, Thickness & Chequered Height) |
- |
1000 |
|
Dimenions |
| Cl. 11(Weight) |
- |
1000 |
|
Weight |
| Cl. 10(Thickness) |
- |
1000 |
|
Dimension |
| Cl. 10(Width) |
- |
1000 |
|
Dimension |
| Cl.8(Elongation) |
- |
7500 |
|
Elongation |
| Cl.8(Yield Stress) |
- |
7500 |
|
Yield Stress |
| Cl 10(Length, Width, Thickness & Chequered Height) |
- |
1000 |
|
Chequered Height |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 41 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
-
|
60000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.5(Components) |
- |
1000 |
|
- |
| 1.6(Power interface .) |
- |
1000 |
|
- |
| 1.7(Markings and instructions) |
- |
1000 |
|
- |
| 2.1(Protection from electric shock and energy hazards) |
- |
5000 |
|
- |
| 2.2(SELV circuits) |
- |
3000 |
|
- |
| 2.3(TNV circuits) |
- |
5000 |
|
- |
| 2.4(Limited current circuits) |
- |
5000 |
|
- |
| 2.5(Limited power sources .) |
- |
5000 |
|
- |
| 2.6(Provisions for earthing and bonding) |
- |
3000 |
|
- |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
2000 |
|
- |
| 2.8(Safety interlocks) |
- |
2000 |
|
- |
| 2.9(Electrical insulation) |
- |
5000 |
|
- |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
10000 |
|
- |
| 3.1(General) |
- |
2000 |
|
- |
| 3.2(Connection to a mains supply) |
- |
6000 |
|
- |
| 3.3(Wiring terminals for connection of external conductors) |
- |
3000 |
|
- |
| 3.4(Disconnection from the mains supply) |
- |
1000 |
|
- |
| 3.5(Interconnection of equipment) |
- |
1000 |
|
- |
| 4.1(Stability) |
- |
2000 |
|
- |
| 4.2(Mechanical strength) |
- |
5000 |
|
- |
| 4.3(Design and construction) |
- |
3000 |
|
- |
| 4.4(Protection against hazardous moving parts) |
- |
2000 |
|
- |
| 4.5(Thermal requirements) |
- |
4000 |
|
- |
| 4.6(Openings in enclosures) |
- |
3000 |
|
- |
| 4.7(Resistance to fire) |
- |
5000 |
|
- |
| 5.1(Touch current and protective conductor curren) |
- |
3000 |
|
- |
| 5.2(Electric strength) |
- |
5000 |
|
- |
| 5.3(Abnormal operating and fault conditions) |
- |
6000 |
|
- |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
2000 |
|
- |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
5000 |
|
- |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
5000 |
|
- |
| 7.1(General) |
- |
1000 |
|
- |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
1000 |
|
- |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
5000 |
|
- |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
7000 |
|
- |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 42 |
IS 1239 : Part 2 (2011) |
Steel tubes, tubulars and other steel fittings - Specification: Part 2 steel pipe fittings (Fifth Revision) |
Sockets |
-
|
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
18 Dec, 2021 |
- - |
| 43 |
IS 15914 (2011) |
High tensile strength flat rolled steel plate (Up To 6 Mm), sheet and strip for the manufacture of welded gas cylinder - Specification |
All |
-
|
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7(UTM) |
- |
10000 |
|
Tensile |
| Cl 9(Workmanship) |
- |
1000 |
|
Freedom from Defects |
| Cl 10(Length, Width & Thickness) |
- |
1000 |
|
Dimensions |
| 6.0(MICRO ALLOYING) |
- |
500 |
|
Micro Alloying |
| 6.0(ALUMINIUM) |
- |
100 |
|
Aluminium |
| 6.0(SILICON) |
- |
500 |
|
Silicon |
| 6.0(MANGANESE) |
- |
500 |
|
Manganese |
| 6.0(PHOSPHORUS) |
- |
500 |
|
Phosphorous |
| 6.0(SULPHUR) |
- |
500 |
|
Sulphur |
| 6.0(CARBON) |
- |
500 |
|
Carbon |
| 6.0(NITROGEN) |
- |
2000 |
|
Nitrogen |
| Cl. 10(Mass) |
- |
1000 |
|
Weight |
| Cl. 10(Out of square) |
- |
1000 |
|
Dimension |
| Cl. 10(Flatness) |
- |
1000 |
|
Dimension |
| Cl. 10(Camber) |
- |
1000 |
|
Dimension |
| Cl. 10(Width) |
- |
1000 |
|
Dimension |
| Cl. 10(Thickness) |
- |
1000 |
|
Dimension |
| Cl. 7 Table 3(Elongation) |
- |
10000 |
|
Elongation |
| Cl. 7 Table 3(Yield Stress) |
- |
10000 |
|
Yield |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 44 |
IS 299 (2012) |
Alumino - Ferric - Specification (Fifth Revision) |
- |
-
|
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1 (i) Table 1( Insouble matter, Grade 4, A-3) |
- |
1500 |
|
- |
| 1 (ii) Table 1(Soluble iron compound (as Fe2+ and Fe3+), Grade 4, A-4) |
- |
1500 |
|
- |
| 1 (iii) Table 1(Water soluble aluminium compounds (as Al2O3), Grade 4, A-5) |
- |
1500 |
|
- |
| 1 (iv) Table 1(pH (of 5 percent aqueous solution), Grade 4, A-6) |
- |
1000 |
|
- |
| 1 (v) Table 1(Free acidity (as H2SO4)/Basicity (as Al2O3), Grade 4, A-7) |
- |
1500 |
|
- |
| 1 (vi) Table 1( Lead (as Pb), Grade 4, A-8) |
- |
1500 |
|
- |
| 1 (vii) Table 1(Arsenic (as As2O3), Grade 4, A-9) |
- |
1500 |
|
- |
| 1 (viii) Table 1(Mercury (as Hg), Grade 4, A-10) |
- |
1500 |
|
- |
| 1 (ix) Table 1(Manganese (as Mn), Grade 4, A-11) |
- |
1500 |
|
- |
| 1 (x) Table 1(Chromium (as Cr), Grade 1, A-12) |
- |
1500 |
|
- |
| 1 (xi) Table 1(Cadmium (as Cd), Grade 4, A-13) |
- |
1500 |
|
- |
| 1 (xii) Table 1(Selenium (as Se), Grade 4, A-14) |
- |
1500 |
|
- |
| 1 (xiii) (a) Table 1(Organic impurities:Phenolic compounds (as C6H5OH), Garde 4, A-15) |
- |
1500 |
|
- |
| 1 (xiii) (b) Table 1(Anionic detergents (as MASS), Garde 1, A-16) |
- |
1500 |
|
- |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 45 |
IS 1237 (2012) |
Cement Concrete Flooring Tiles - Specification |
All |
-
|
10000 View breakup
For BIS Samples: 1.5 times of BIS Testing Charges. For Others: Rs.1500/- for Chemical Tests Rs.9000/- for Physical Tests Rs.10,000/- for Complete Tests
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7.1(Length, Breadth, Minimum thickness, Difference in length of side between the longest side and shorterst side, Half tiles, Difference in Thickness between the thickest and thinnest tile, Thickness of wearing layer) |
- |
750 |
|
All Dimension |
| Cl 12.2(Concavity & Convexity ) |
- |
750 |
|
All Dimension |
| Cl 12.3(The Maximum gap between the arms of the square and the edge of the title shall notexceed 2 percent of the length.) |
- |
750 |
|
All Dimension |
| Cl 12.4(Shall not exceed 1 percent of the length of the edge.) |
- |
750 |
|
All Dimension |
| Cl 12.5(Water absorption) |
- |
1000 |
|
Water absorption |
| Cl 12.6(Wet transverse strength ) |
- |
2000 |
|
Wet transverse strength |
| Cl 12.7(Resistance to wear) |
- |
5000 |
|
Resistance to wear |
| Cl 11(Suface Finish) |
- |
500 |
|
Surface Finish |
| Cl 7.1(Length, Breadth, Minimum thickness, Difference in length of side between the longest side and shorterst side, Half tiles, Difference in Thickness between the thickest and thinnest tile, Thickness of wearing layer) |
- |
750 |
|
All Dimension |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 46 |
IS 2830 (2012) |
Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling into steel for general structural purposes - Specification (Third Revision) |
All |
-
|
16000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 9(Workmanship) |
- |
500 |
|
Freedom from defects |
| Cl 10.1(Workmanship) |
- |
500 |
|
Macro Examination |
| Cl 10.2(Workmanship) |
- |
500 |
|
Bend |
| Cl 10.3(Workmanship) |
- |
500 |
|
Camber |
| Cl 11(Length, Width & Thickness) |
- |
500 |
|
Dimension |
| 6.1(Carbon %) |
- |
500 |
|
Carbon |
| 6.1(Manganese %) |
- |
500 |
|
Manganese |
| 6.1(Phosphorus %) |
- |
500 |
|
Phosphorous |
| 6.1(Sulphur %) |
- |
500 |
|
Sulphur |
| 6.1(Silicon %) |
- |
500 |
|
Silicon |
| 6.1( Nitrogen%) |
- |
500 |
|
Nitrogen |
| 6.1( Copper %) |
- |
100 |
|
Copper |
| 6.1( Aluminium %) |
- |
100 |
|
Aluminium |
| 6.1( Nb) |
- |
100 |
|
Niobium |
| 6.1(V) |
- |
100 |
|
Vanadium |
| 6.1( Ti) |
- |
100 |
|
Titanium |
| 6.1(Cr) |
- |
100 |
|
Chromium |
| 6.1(Mo) |
- |
100 |
|
Moybdenum |
| 6.1(Ni) |
- |
100 |
|
Nickle |
| 10.1 (a)(Macro-examination) |
- |
500 |
|
Macro Examination |
| Cl. 10.2(Bend) |
- |
500 |
|
Dimension |
| Cl. 10.3(Camber) |
- |
500 |
|
Dimension |
| 11(Width) |
- |
500 |
|
Dimension |
| 11(Thickness) |
- |
500 |
|
Dimension |
| Cl. 10.1 (b)(Sulphur Print) |
- |
8000 |
|
Sulphur Print |
| Cl. 11.2(Out of Squareness) |
- |
500 |
|
Dimension |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 47 |
IS 2831 (2012) |
Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling into structural steel (Ordinary Quality) - Specification (Fourth Revision) |
All |
-
|
16000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9( FREEDOM FROM DEFECTS) |
- |
500 |
|
Freedom from Defects |
| 10.1.a)( Macro examination IS 11371) |
- |
500 |
|
Macro Examination |
| 10.1.b)( Sulphur print tests IS 12037) |
- |
8000 |
|
Sulphur Print |
| 11 & 12(DIMENSIONS and Tolerances) |
- |
500 |
|
Dimension |
| Cl. 6.1, Table 1(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Carbon |
| Cl. 6.1, Table 1(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Manganese |
| Cl. 6.1, Table 1(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Sulphur |
| Cl. 6.1, Table 1(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Phosphorous |
| Cl. 6.1, Table 1(Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Silicon |
| Cl. 6.1, Table 1(Aluminium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
100 |
|
Aluminium |
| Cl. 6.1, Table 1(Nitrogen- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1500 |
|
Nitrogen |
| Cl. 6.1, Table 1(Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
100 |
|
Copper |
| Cl. 6.1, Table 1(Niobium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
100 |
|
Niobium |
| Cl. 6.1, Table 1(Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
100 |
|
Vanadium |
| Cl. 6.1, Table 1(Titanium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
100 |
|
Titanium |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 48 |
IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
- |
-
|
21800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
1000 |
|
- |
| 5(Classification of Luminaires') |
- |
1000 |
|
- |
| 6.0(Marking) |
- |
3000 |
|
- |
| 7.0(Construction) |
- |
10000 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
6000 |
|
- |
| 9.0(Provision for earthing) |
- |
5000 |
|
- |
| 10.0(Terminals) |
- |
9000 |
|
- |
| 11.0(External & Internal Wiring) |
- |
6000 |
|
- |
| 12.0(Protection against electric shock) |
- |
5000 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
14000 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
15000 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
10000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
12000 |
|
- |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 49 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
-
|
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
1000 |
|
- |
| 8(Protection against accidental contact with live parts) |
- |
5000 |
|
- |
| 9(Terminals) |
- |
8000 |
|
- |
| 10(PROVISION FOR EARTHING) |
- |
3000 |
|
- |
| 11(MOISTURE RESISTANCE) |
- |
9000 |
|
- |
| 12(Electric Strength) |
- |
5000 |
|
- |
| 13(Thermal endurance test for winding of ballasts) |
- |
1000 |
|
- |
| 14(Fault conditions) |
- |
8000 |
|
- |
| 15(Transformer heating) |
- |
9000 |
|
- |
| 16(Construction) |
- |
6000 |
|
- |
| 17(Creepage distance and clearances) |
- |
5000 |
|
- |
| 18(Screws, current carrying parts and connections) |
- |
5000 |
|
- |
| 19(Resistance to heat, fire and tracking) |
- |
10000 |
|
- |
| 20(Resistance to corrosion) |
- |
5000 |
|
- |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 50 |
IS 15961 (2012) |
Hot dip aluminium - Zinc alloy metallic coated steel strip and sheet (Plain) |
All |
-
|
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8(UTM) |
- |
5000 |
|
Tensile |
| Cl 9 & Table 2(Workmanship) |
- |
2000 |
|
Mass of Zinc Coating |
| Cl 10(Coating Adhesion ) |
- |
2000 |
|
Coating Adhesion |
| Cl 11(Workmanship) |
- |
500 |
|
Freedom From Defects |
| Cl 12(Weight) |
- |
500 |
|
Weight |
| Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
1000 |
|
Dimension |
| 4, 5(CARBON) |
- |
250 |
|
ok |
| 4, 5(SULPHUR) |
- |
250 |
|
ok |
| 4, 5(PHOSPHURS) |
- |
250 |
|
ok |
| 4.5(MANGANESE) |
- |
250 |
|
ok |
| 4, 5(NITROGEN) |
- |
500 |
|
ok |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 51 |
IS 15962 (2012) |
Structural steels for buildings and structures with improved seismic resistance |
All |
-
|
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 6(Freedom from Defects) |
- |
2000 |
|
Freedom from Defects |
| Cl 10(Tensile Test) |
- |
25000 |
|
Tensile Test |
| Cl 11(Impact Test) |
- |
7500 |
|
Impact Test |
| Cl 13(Dimensions) |
- |
2000 |
|
Dimensions |
| Cl 16(Mass) |
- |
500 |
|
Mass |
| Clauses 7, 8.1 & .2, Table- 1(E250S, C) |
- |
100 |
|
Carbon |
| Clauses 7, 8.1 & .2, Table- 1(E250S, Mn ) |
- |
100 |
|
Manganese |
| Clauses 7, 8.1 & .2, Table- 1(E250S, P) |
- |
100 |
|
Phosphorous |
| Clauses 7, 8.1 & .2, Table- 1(E250S, S) |
- |
100 |
|
Sulphur |
| Clauses 7, 8.1 & .2, Table- 1(E250S, Si) |
- |
100 |
|
Silicon |
| Clauses 7, 8.1 & .2, Table- 1(E250S, CE) |
- |
500 |
|
Carbon Equivalent |
| Clauses 7, 8.1 & .2, Table- 1(E300S, C) |
- |
100 |
|
Carbon |
| Clauses 7, 8.1 & .2, Table- 1(E300S, Mn) |
- |
100 |
|
Manganese |
| Clauses 7, 8.1 & .2, Table- 1(E300S, P) |
- |
100 |
|
Phosphorous |
| Clauses 7, 8.1 & .2, Table- 1(E300S, S) |
- |
100 |
|
Sulphur |
| Clauses 7, 8.1 & .2, Table- 1(E300S, Si) |
- |
100 |
|
Silicon |
| Clauses 7, 8.1 & .2, Table- 1(E300S, CE) |
- |
500 |
|
Carbon Equivalent |
| Clauses 7, 8.1 & .2, Table- 1(E350S, C) |
- |
100 |
|
Carbon |
| Clauses 7, 8.1 & .2, Table- 1(E350S, Mn) |
- |
100 |
|
Manganese |
| Clauses 7, 8.1 & .2, Table- 1(E350S, P) |
- |
100 |
|
Phosphorous |
| Clauses 7, 8.1 & .2, Table- 1(E350S, S) |
- |
100 |
|
Sulphur |
| Clauses 7, 8.1 & .2, Table- 1(E350S, Si) |
- |
100 |
|
Silicon |
| Clauses 7, 8.1 & .2, Table- 1(E450S, C) |
- |
100 |
|
Carbon |
| Clauses 7, 8.1 & .2, Table- 1(E450S, Mn) |
- |
100 |
|
Manganese |
| Clauses 7, 8.1 & .2, Table- 1(E450S, P) |
- |
100 |
|
Phosphorous |
| Clauses 7, 8.1 & .2, Table- 1(E450S, S) |
- |
100 |
|
Sulphur |
| Clauses 7, 8.1 & .2, Table- 1(E450S, Si) |
- |
100 |
|
Silicon |
| Clauses 7, 8.1 & .2, Table- 1(E450S, CE) |
- |
500 |
|
Carbon Equivalent |
| Clauses 7, 8.1 & .2, Table- 1(E350S, CE) |
- |
500 |
|
Carbon Equivalent |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 52 |
IS 15997 (2012) |
Low nickel austenitic stainless steel sheet and strip for utensils and kitchen appliances - Specification |
All |
-
|
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Carbon |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Silicon |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Manganese |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1500 |
|
Nickle |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
750 |
|
Chromium |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Suphur |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Phosphorous |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Copper -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
750 |
|
Copper |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1500 |
|
Nitrogen |
| 6(Freedom From Defects) |
- |
500 |
|
Freedom from Defects |
| 9.3(Tensile Test-1608:Part 1) |
- |
10000 |
|
Tensile Test |
| 9.3, Table 3 (Yield Strength, Mpa) |
- |
10000 |
|
Tensile |
| 9.3, Table 3 (Elongation, %) |
- |
10000 |
|
Tensile |
| 9.4(Erichsen Cupping Test,(Average depth of cupping) mm) |
- |
2000 |
|
Cupping |
| 12(Dimensions) |
- |
1000 |
|
Dimensions |
| 14.1(Thickness,mm) |
- |
1000 |
|
Dimensions |
| 14.2( Width, mm) |
- |
1000 |
|
Dimensions |
| 14.3(Length, mm) |
- |
1000 |
|
Dimensions |
| 14.4(Flatness, mm) |
- |
1000 |
|
Dimensions |
| 14.5(Camber, mm) |
- |
1000 |
|
Dimensions |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 53 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
-
|
48000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
1000 |
|
- |
| 6(Interchangeability) |
- |
5000 |
|
- |
| 7(Protection against accidental contact with live parts) |
- |
5000 |
|
- |
| 8(Insulation Resistance and Electric Strength) |
- |
10000 |
|
- |
| 9(MECHANICAL STRENGTH) |
- |
5000 |
|
- |
| 10(cap temperature) |
- |
5000 |
|
- |
| 11(Resistance to Heat) |
- |
5000 |
|
- |
| 12(Resistance to Flame and Ignition) |
- |
4000 |
|
- |
| 13(Fault conditions) |
- |
9000 |
|
- |
| 14(Creepage distance and clearances) |
- |
5000 |
|
- |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 54 |
IS 3812 (Part 1) (2013) |
Pulverized fuel ash - Specification: Part 1 For use as pozzolana in cement, cement mortar and concrete |
- |
-
|
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1-Table 2(i)(PHYSICAL REQUIREMENTS-Fineness) |
- |
2000 |
|
PHYSICAL REQUIREMENTS-Fineness |
| 7.1-Table 2(ii)(PHYSICAL REQUIREMENTS-Particles retained on 45 micron IS sieve) |
- |
2000 |
|
PHYSICAL REQUIREMENTS-Particles retained on 45 micron IS sieve |
| 7.1-Table 2(iii)(PHYSICAL REQUIREMENTS-Average compressive strength) |
- |
7500 |
|
PHYSICAL REQUIREMENTS-Average compressive strength |
| 7.1-Table 2(iv)(PHYSICAL REQUIREMENTS-Compressive strength at 28 days) |
- |
7500 |
|
PHYSICAL REQUIREMENTS- all Compressive strength at 28 days |
| 7.1-Table 2(v)(PHYSICAL REQUIREMENTS-Soundness by autoclave test ) |
- |
3000 |
|
PHYSICAL REQUIREMENTS-Soundness by autoclave test |
| Cl. 6.1, Table 1 - i(Silicon dioxide (SiO2) plus aluminium oxide (Al2O3) plus ironoxide (Fe2O3) - IS 1727) |
- |
5000 |
|
Silicon dioxide (SiO2) plus aluminium oxide (Al2O3) plus ironoxide (Fe2O3) - IS 1727 |
| Cl. 6.1, Table 1 - ii(Silicon dioxide (SiO2) - IS 1727) |
- |
1500 |
|
Silicon dioxide (SiO2) - IS 1727 |
| Cl. 6.1, Table 1 - iii(Reactive Silica - Annex B) |
- |
1500 |
|
Reactive Silica - Annex B |
| Cl. 6.1, Table 1 - iv(Magnesium oxide (MgO) - IS 1727) |
- |
1500 |
|
Magnesium oxide (MgO) - IS 1727 |
| Cl. 6.1, Table 1 - v( Total sulphur as sulphur trioxide (SO3) - IS 1727) |
- |
1500 |
|
Total sulphur as sulphur trioxide (SO3) - IS 1727 |
| Cl. 6.1, Table 1 - vi( Available alkalis as equivalent sodium oxide (Na2O) - Annex C) |
- |
5000 |
|
Available alkalis as equivalent sodium oxide (Na2O) - Annex C |
| Cl. 6.1, Table 1 - vii( Total Chlorides - IS 4032) |
- |
3000 |
|
Total Chlorides - IS 4032 |
| Cl. 6.1, Table 1 - viii( Loss on ignition - IS 1727) |
- |
3000 |
|
Loss on ignition |
| Cl. 6.2(Moisture content of the fly ash when supplied in dry condition - Annex D) |
- |
2000 |
|
Moisture content of the fly ash when supplied in dry condition |
| 5.1, 7.1, table-2, iii(Lime reacitivity) |
- |
10000 |
|
- |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 55 |
IS 3812 : Part 2 (2013) |
Pulverized Fuel Ash - Part 2 : For Use as Admixture in Cement Mortar and Concrete |
- |
-
|
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1, Table 1(Fineness — Specific surface in m2 /kg) |
- |
2000 |
|
Fineness — Specific surface |
| 7.1, Table 1(Particles retained on 45 micron IS sieve (wet sieving)) |
- |
2000 |
|
Particles retained on 45 micron IS sieve (wet sieving) |
| 7.1, Table 1(Soundnes) |
- |
2000 |
|
Soundness |
| 5.1, 6.1, Table 1(Silicon dioxide (SiO2 ) plus aluminium oxide (Al2O3 ) plus iron oxide (Fe2O3 )) |
- |
5000 |
|
Silicon dioxide (SiO2 ) plus aluminium oxide (Al2O3 ) plus iron oxide (Fe2O3 ) |
| 5.1, 6.1, Table 1(Silicon dioxide (SiO2 )) |
- |
1500 |
|
Silicon dioxide (SiO2 ) |
| 5.1, 6.1, Table 1(Magnesium oxide (MgO) |
- |
1500 |
|
Magnesium oxide |
| 5.1, 6.1, Table 1(Total sulphur as sulphur trioxide (SO3) |
- |
1500 |
|
Total sulphur as sulphur trioxide |
| 5.1, 6.1, Table 1(Available alkalies as equivalent sodium oxide (Na2O)) |
- |
1500 |
|
Available alkalies as equivalent sodium oxide |
| 5.1, 6.1, Table 1(Total chlorides) |
- |
5000 |
|
Total chlorides |
| 5.1, 6.1, Table 1(Loss on ignition) |
- |
3000 |
|
Loss on ignition |
| 6.2(moisture content) |
- |
2000 |
|
moisture content |
| Clauses 5.1 & 7.1 Table No. 2, SI No. (i)
(Fineness- Specific surface by blaine's method) |
- |
2000 |
|
- |
| Clauses 5.1 & 7.1 Table No. 2, SI No. (ii)
(Particles retained on 45 micron IS Sieve (we sieving)) |
- |
2000 |
|
- |
| Clauses 5.1 & 7.1 Table No. 2, SI No. (iii)
(Soundness by autoclave test - Expansion of specimen) |
- |
2000 |
|
- |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 56 |
IS 13592 (2013) |
Unplasticized Polyvinyl Chloride (PVC-U) Pipes for Soil and Waste Discharge System Inside and Outside Buiildings Including Ventilation and Rainwater System |
- |
-
|
13500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.5(Surface colour of the pipes shall be dark shade of grey) |
- |
500 |
|
ok |
| Cl6.3(The composition shall be based on PVC resin
having a K-value of 64 or greater when tested in
accordance with IS 4669) |
- |
2000 |
|
ok |
| Cl.7.1(Mean outside diameter, outside diameter at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
1000 |
|
ok |
| Cl.7.1( outside diameter at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
1000 |
|
ok |
| Cl.7.1( wall thickness at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
1000 |
|
ok |
| Cl.7.2(Pipes shall be supplied in nominal lengths of 2, 3, 4 or
6 metres either plain or with socket for solvent
cementing/grooved socket. Tolerances on specified
length shall be + 10 mm and – 0 mm.The nominal length of the pipe with socket for solvent
cementing/grooved socket shall be as given in Fig. 1.) |
- |
1000 |
|
ok |
| Cl.7.3.1(Minimum wall thickness of socket on pipes shall
be as given in Table 2 read with Fig. 2 and Fig. 3.) |
- |
1000 |
|
ok |
| Cl.7.3.2(Dimensions of sockets for solvent cementing and
grooved sockets of pipes shall be as given in Tables 3
and 4 respectively, read with Fig. 2 and 3.) |
- |
1000 |
|
ok |
| Cl.8.1(The internal and external surface of the pipes shall be
smooth and clean, and free from grooving and other
defects. The end shall be clearly cut and shall be square
with the axis of the pipe. The end may be chamfered
on the plain side.) |
- |
500 |
|
ok |
| Cl.8.2(When tested by the method described in IS 12235
(Part 5), a length of pipe sample of 200 ± 20 mm shall
not alter in length by more than 5 percent. In the case
of socket ended pipes, this test shall be carried out on
the plain portion of pipe taken at least 100 mm away
from the root of the socket.) |
- |
2000 |
|
ok |
| Cl8.3(This test shall be carried out for socket end pipes only.
When tested by the method described in IS 12235
(Part 6), the test specimens shall not show blisters,
excessive delamination or cracking or signs of weld
line splitting.) |
- |
5000 |
|
ok |
| Cl.8.4(When determined in accordance with IS 12235 (Part 2),
the vicat softening temperature of the specimen shall
not be less than 79°C.) |
- |
2000 |
|
ok |
| Cl.8.5(After the required
period of exposure, the tensile strengths of two samples when tested as per IS 12235 (Part 13) shall not show
difference of more than 20 percent of their initial tensile
strengths) |
- |
5000 |
|
ok |
| Cl. 9, IS 12235 Part 7(Resistance to Sulphuric Acid) |
- |
2000 |
|
ok |
| Cl.10.1(When tested by method prescribed in IS 12235 (Part 9),the pipe shall have a true impact rate of not more than
10 percent. Mass of striker and height of fall shall be
as per Annex A.) |
- |
1000 |
|
ok |
| Cl.10.2(When determined in accordance with the method
described in IS 12235 (Part 13), the tensile strength at
break shall not be less than 45 MPa.) |
- |
2000 |
|
ok |
| Cl.10.3(The axial shrinkage shall not exceed 2 percent when
determined in accordance with Annex B.) |
- |
5000 |
|
ok |
| Cl.11.(Jointing of solvent
cementing joints is to be carried out using solvent
conforming to IS 14182.
Apply a pressure of 0.05 MPa for a period of 15 min
and there should be no leakage at any joint.) |
- |
2000 |
|
ok |
| Cl. 12, IS 12235 Part 11(Resistance to Di-Chloro-Methane ) |
- |
5000 |
|
ok |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 57 |
IS 13801 (2013) |
Chequered Cement Concrete Tiles - |
All |
-
|
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| (Cl 7, 8 &9)(Length, Breadth, Thickness, Difference in length of side between the longest side and shorterst side in the sample shall not exceed 1 mm, Half tiles, Difference in Thickness between the thickest and thinnest tile in the sample shall not exceed 10 percent of minimum thickness, Depth of chequred groove, Thickness of wearing layer.) |
- |
1000 |
|
All Dimensions |
| Cl 12.1(Concavity & Convexity ) |
- |
500 |
|
Surface Flatness and Finish |
| Cl 12.2(Longest gap between the arms of the square and the edge of the title shall not exceed 2 percent of the length.) |
- |
1000 |
|
All Dimensions |
| Cl 12.3(Shall not exceed 1 percent of the length of the edge.) |
- |
1000 |
|
All Dimensions |
| Cl 12.4(Water absorption) |
- |
1000 |
|
Water absorption |
| Cl 12.5(Wet transverse strength) |
- |
5000 |
|
Wet transverse strength |
| Cl 12.6(Resistance to wear) |
- |
5000 |
|
Resistance to wear |
| Cl 11(Finish) |
- |
500 |
|
Surface Flatness and Finish |
| Cl 11(Finish) |
- |
500 |
|
Surface Flatness and Finish |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 58 |
IS 14246 (2013) |
Continuously pre-painted galvanized steel sheets and coils (First Revision) |
All |
-
|
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4.1(Workmanship) |
- |
2000 |
|
Chemical Composition |
| Cl 4.2(Workmanship) |
- |
1500 |
|
Mass of Zinc Coating |
| Cl 4.3(Workmanship) |
- |
3000 |
|
Organic Coating |
| Cl 6.2(Press) |
- |
2000 |
|
Bend |
| Cl 6.3(HWB) |
- |
1500 |
|
Pencil Hardness |
| Cl 6.4(Load Resistance) |
- |
5000 |
|
Impact |
| Cl 6.5(Cross Hatch) |
- |
1000 |
|
Cross Hatch |
| Cl 8(Salt Spray) |
- |
10000 |
|
Salt Spray |
| Cl 9(Length, Width, Thickness & Mass) |
- |
1000 |
|
Dimension |
| Cl 10(Camber, Deviation From Squareness (Out-of- Square) & Deviation From Flatness) |
- |
1000 |
|
Dimension |
| Cl. 10.1(Camber) |
- |
1000 |
|
Dimension |
| Cl 8(Salt Spray) |
- |
10000 |
|
Salt Spray |
| Cl. 10.3, Table 4(Flatness) |
- |
1000 |
|
Dimension |
| Cl. 10.2(Out of square) |
- |
1000 |
|
Dimension |
| Cl. 9.4.2(Width) |
- |
1000 |
|
Dimension |
| Cl. 9.4.4(Mass) |
- |
1000 |
|
Mass |
| Cl. 7.3.1(Gloss Top Coat) |
- |
2000 |
|
Gloss |
| Cl. 7.3.2 Table 3(Color Bottom Coat) |
- |
1500 |
|
Colour |
| Cl. 7.3.2 Table 3(Color Top Coat) |
- |
1500 |
|
Color |
| Cl. 7.3.1(Gloss Bottom Coat) |
- |
2000 |
|
Gloss |
|
Complete
|
|
18 Dec, 2021 |
- - |
| 59 |
IS 253 (2014) |
Specification for common salt (Fourth Revision) |
- |
-
|
- View breakup
Rs.7000/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
18 Dec, 2021 |
- - |
| 60 |
IS 302 : Part 2 : Sec 26 (2014) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 26 clocks (First Revision) |
- |
-
|
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
1000 |
|
- |
| 8(Protection against live parts) |
- |
3000 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
1000 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
7000 |
|
- |
| 11(HEATING) |
- |
8000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
8000 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
7000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
10000 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
8000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
7000 |
|
- |
| 18(ENDURANCE) |
- |
1000 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
9000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
2000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
8000 |
|
- |
| 22(CONSTRUCTION) |
- |
5000 |
|
- |
| 23(INTERNAL WIRING) |
- |
4000 |
|
- |
| 24(COMPONENTS) |
- |
2000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
7000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
5000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
3000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
6000 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
8000 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
12000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
2000 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
2000 |
|
- |
| 15.4 (b)(Cold impact) |
- |
7000 |
|
- |
|
Complete
|
|
18 Dec, 2021 |
- - |